Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

1024x1024 Pixel MWIR and LWIR QWIP Focal Plane Arrays and 320x256 MWIR:LWIR Pixel Colocated Simultaneous Dualband QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NE(Delta)T) of 17 mK at a 95K operating temperature with f/2.5 optics at 300K background and the LWIR detector array has demonstrated a NE(Delta)T of 13 mK at a 70K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90K and 70K operating-temperatures respectively, with similar optical and background conditions. In addition, we are in the process of developing MWIR and LWIR pixel collocated simultaneously readable dualband QWIP focal plane arrays.

quantum wells↗

A tweezer array with 6,100 highly coherent atomic qubits

Optical tweezer arrays have transformed atomic and molecular physics, now forming the backbone for a range of leading experiments in quantum computing, simulation and metrology. Typical experiments trap tens to hundreds of atomic qubits and, recently, systems with around 1,000 atoms were realized without defining qubits or demonstrating coherent control. However, scaling to thousands of atomic qubits with long coherence times and low-loss and high-fidelity imaging is an outstanding challenge and critical for progress in quantum science, particularly towards quantum error correction (QEC). Here we experimentally realize an array of optical tweezers trapping more than 6,100 neutral atoms in around 12,000 sites, simultaneously surpassing state-of-the-art performance for several metrics that underpin the success of the platform. Specifically, while scaling to such a large number of atoms, we demonstrate a coherence time of 12.6(1) s, a record for hyperfine qubits in an optical tweezer array. We show room-temperature trapping lifetimes of about 23 min, enabling record-high imaging survival of 99.98952(1)% with an imaging fidelity of more than 99.99%. We present a plan for zone-based quantum computing and demonstrate necessary coherence-preserving qubit transport and pick-up/drop-off operations on large spatial scales, characterized through interleaved randomized benchmarking. Our results, along with recent developments, indicate that universal quantum computing and QEC with thousands to tens of thousands of physical qubits could be a near-term prospect.

atomic and molecular physics↗

The DUV Stability of Superlattice-Doped CMOS Detector Arrays

JPL and Alacron have recently developed a high performance, DUV camera with a superlattice doped CMOS imaging detector. Supperlattice doped detectors achieve nearly 100% internal quantum efficiency in the deep and far ultraviolet, and a single layer, Al2O3 antireflection coating enables 64% external quantum efficiency at 263nm. In lifetime tests performed at Applied Materials using 263 nm pulsed, solid state and 193 nm pulsed excimer laser, the quantum efficiency and dark current of the JPL/Alacron camera remained stable to better than 1% precision during long-term exposure to several billion laser pulses, with no measurable degradation, no blooming and no image memory at 1000 fps.

silicon detectors↗

Delta-Doped Back-Illuminated CMOS Imaging Arrays: Progress and Prospects

In this paper, we report the latest results on our development of delta-doped, thinned, back-illuminated CMOS imaging arrays. As with charge-coupled devices, thinning and back-illumination are essential to the development of high performance CMOS imaging arrays. Problems with back surface passivation have emerged as critical to the prospects for incorporating CMOS imaging arrays into high performance scientific instruments, just as they did for CCDs over twenty years ago. In the early 1990's, JPL developed delta-doped CCDs, in which low temperature molecular beam epitaxy was used to form an ideal passivation layer on the silicon back surface. Comprising only a few nanometers of highly-doped epitaxial silicon, delta-doping achieves the stability and uniformity that are essential for high performance imaging and spectroscopy. Delta-doped CCDs were shown to have high, stable, and uniform quantum efficiency across the entire spectral range from the extreme ultraviolet through the near infrared. JPL has recently bump-bonded thinned, delta-doped CMOS imaging arrays to a CMOS readout, and demonstrated imaging. Delta-doped CMOS devices exhibit the high quantum efficiency that has become the standard for scientific-grade CCDs. Together with new circuit designs for low-noise readout currently under development, delta-doping expands the potential scientific applications of CMOS imaging arrays, and brings within reach important new capabilities, such as fast, high-sensitivity imaging with parallel readout and real-time signal processing. It remains to demonstrate manufacturability of delta-doped CMOS imaging arrays. To that end, JPL has acquired a new silicon MBE and ancillary equipment for delta-doping wafers up to 200mm in diameter, and is now developing processes for high-throughput, high yield delta-doping of fully-processed wafers with CCD and CMOS imaging devices.

imagers↗

Two-Photon Ghost Image and Interference-Diffraction

One of the most surprising consequences of quantum mechanics is entanglement of two or more distance particles. The two-particle entangled state was mathematically formulated by Schrodinger. Based on this unusual quantum behavior, EPR defined their 'physical reality' and then asked the question: 'Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?' One may not appreciate EPR's criterion of physical reality and insist that 'no elementary quantum phenomenon is a phenomenon until it is a recorded phenomenon'. Optical spontaneous parametric down conversion (SPDC) is the most effective mechanism to generate an EPR type entangled two-photon state. In SPDC, an optical beam, called the pump, is incident on a birefringent crystal. The pump is intense enough so that nonlinear effects lead to the conversion of pump photons into pairs of photons, historically called signal and idler. Technically, the SPDC is said to be type-1 or type-2, depending on whether the signal and idler beams have parallel or orthogonal polarization. The SPDC conversion efficiency is typically on the order of 10(exp -9) to 10(exp -11), depending on the SPDC nonlinear material. The signal and idler intensities are extremely low, only single photon detection devices can register them. The quantum entanglement nature of SPDC has been demonstrated in EPR-Bohm experiments and Bell's inequality measurements. The following two experiments were recently performed in our laboratory, which are more closely related to the original 1935 EPR gedankenezperiment. The first experiment is a two-photon optical imaging type experiment, which has been named 'ghost image' by the physics community. The signal and idler beams of SPDC are sent in different directions, so that the detection of the signal and idler photons can be performed by two distant photon counting detectors. An aperture object (mask) is placed in front of the signal photon detector and illuminated by the signal beam through a convex lens. Surprisingly, an image of this aperture is observed in the idler beam, by scanning the idler photon detector in the transverse plane of the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal, which can be easily performed by a coincidence measurement. This effect is even more striking when we found that the object-lens-image relationship satisfies the Gaussian thin lens equation. The second experiment demonstrates two-photon 'ghost' interference-diffraction. The experimental set up is similar to the image experiment, except that rather than a lens and an aperture it is a Young's double-slit (or a single-slit) inserted into the path of the signal beam. We could not find any interference (or diffraction) pattern behind the slit. Surprisingly, an interference (or diffraction) pattern is observed when scanning the detector in the idler beam, if we are sure that the idler photon detector 'catches' the 'twin brother' of the signal.

Shih, Y. H.↗

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

The AXAF CCD Imaging Spectrometer Experiment (ACIS)

The ACIS experiment consists of an array of charge coupled device (CCD) chips placed at the focus of the AXAF mirror assembly. The instrument offers a powerful combination of the best qualities of the entire generation of Einstein Observatory detectors. The pixel size is well matched to the resolution of the telescope, while the high quantum efficiency nondispersive spectroscopy capability means that every object imaged will produce a moderate resolution spectrum. In conjunction with the objective gratings the energy resolution increases to 1000 with a loss of efficiency of only 50 percent. While the great capability of ACIS will naturally make it attractive for a wide range of AXAF investigations, ACIS has a particular advantage in fields where it can simultaneously acquire imaged spectra of many objects. These include compact star clusters, star formation regions, the nuclear regions of nearby galaxies, entire galaxies in the Virgo Cluster and the entire Coma Cluster.

Nousek, J. A.↗

Stable vacuum UV CCD detectors designed for space flight experiments

Thinned, backside-illuminated, p-channel CCD images are under development which can exploit the surface potential in VUV applications, yielding enhanced quantum efficiency to wavelengths as short as 1100 A. The current goal is production of large-format, 5-micron pixel imagers for spectrographic and imaging VUV spaceflight experiments. Model predictions of the effect of device design on quantum efficiency, well capacity, and crosstalk are presented for such 5-micron-approaching pixel sizes.

Socker, Dennis G.↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Optimization of Noise Performance of Low-Back Ground Detector Arrays

The performance of the 2k x 2k Teledyne H2RG detectors is key to the success of the JWST mission. For broadband imaging, where background limited sensitivity is quickly reached, the key parameter is the quantum efficiency of the detectors, which is, in general, very good. For near infrared spectroscopy and narrow band imaging, we cannot generally reach the back-round limit, so instrument sensitivity is directly dependent on the read noise of the detector. We have initiated a program to analyze the noise characteristics of the H2RG detectors, studying the correlations among the detector outputs and with the reference output, as well as the temporal correlations in a given detector section. Lasing the measured characteristics of the noise correlations, we can determine the optimal coefficients for the removal of correlated noise as a function of frequency. By using available reference sources and adding more frequent references, we have been able to reduce the noise by a factor of two. We find that the detectors have significantly lower noise that observed in prior tests, and can offer significant improvements in the performance of the JWST instruments. We will present the analysis and mitigation techniques, discuss prospects for further improvements with existing detectors, and describe considerations for improvements in next-generation detectors.

Rauscher, Bernard J.↗

Tunable-Quantum-Well Infrared Detector

Proposed detector of infrared photons based on photon-assisted, resonant quantum-mechanical tunneling between adjacent energy wells in its semiconductor structure. Wavelength adjusted by changing applied voltage. Device contains alternating layers of different seminconductors which form double-quantum-well electron-energy structure. Tunable-quantum-well detectors made on single chip constitutes line imager. Many such devices stacked to form two-dimensional imaging device. Signal-processing circuitry integrated into chip at its lower end. Potential barriers and wells produced by alternating layers of different semiconductor materials. Steepness of slope proportional to applied electric field. Electric field and thicknesses and heights of barriers selected to favor photon-assisted, resonant quantum-mechanical tunneling at chosen photon frequency.

Maserjian, Joseph↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

Imaging shapes of atomic nuclei in high-energy nuclear collisions

Atomic nuclei are self-organized, many-body quantum systems bound by strong nuclear forces within femtometre-scale space. These complex systems manifest a variety of shapes, traditionally explored using non-invasive spectroscopic techniques at low energies. However, at these energies, their instantaneous shapes are obscured by long-timescale quantum fluctuations, making direct observation challenging. Here we introduce the collective-flow-assisted nuclear shape-imaging method, which images the nuclear global shape by colliding them at ultrarelativistic speeds and analysing the collective response of outgoing debris. This technique captures a collision-specific snapshot of the spatial matter distribution within the nuclei, which, through the hydrodynamic expansion, imprints patterns on the particle momentum distribution observed in detectors. We benchmark this method in collisions of ground-state uranium-238 nuclei, known for their elongated, axial-symmetric shape. Our findings show a large deformation with a slight deviation from axial symmetry in the nuclear ground state, aligning broadly with previous low-energy experiments. This approach offers a new method for imaging nuclear shapes, enhances our understanding of the initial conditions in high-energy collisions and addresses the important issue of nuclear structure evolution across energy scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Charge-Coupled Imager For X Rays

Device proposed to improve imaging of x rays. Features thin layer of oxide in virtual phase to increase quantum efficiency and depletion layer nearly as thick as epitaxial silicon layer to increase resolution. Applications include imaging spectrometers for x-ray astronomy, investigations of plasmas, and x-ray crystallography.

Wadsworth, Mark↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗

Far-Infrared Imaging Radiometer

Inexpensive far-infrared imaging radiometer contains 128 X 128-picture-element array of AlxGa1-xAs quantum-well detectors. Potentially useful in remote sensing from airborne platforms. Industrial applications include rapid thermal imaging of heat-sensitive components. Astronomical applications include imaging of planets and Sun.

Forrest, Kathrine↗