Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Controlled Self-Assembly of Gold Nanotetrahedra into Quasicrystals and Complex Periodic Supracrystals

The self-assembly of shape-anisotropic nanocrystals into large-scale structures is a versatile and scalable approach to creating multifunctional materials. The tetrahedral geometry is ubiquitous in natural and manmade materials, yet regular tetrahedra present a formidable challenge in understanding their self-assembly behavior as they do not tile space. Here, we report diverse supracrystals from gold nanotetrahedra including the quasicrystal (QC) and the dimer packing predicted more than a decade ago and hitherto unknown phases. We solve the complex three-dimensional (3D) structure of the QC by a combination of electron microscopy, tomography, and synchrotron X-ray scattering. Nanotetrahedron vertex sharpness, surface ligands, and assembly conditions work in concert to regulate supracrystal structure. We also discover that the surface curvature of supracrystals can induce structural changes of the QC tiling and eventually, for small supracrystals with high curvature, stabilize a hexagonal approximant. Finally, our findings bridge the gap between computational design and experimental realization of soft matter assemblies and demonstrate the importance of accurate control over nanocrystal attributes and the assembly conditions to realize increasingly complex nanopolyhedron supracrystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

Implementation and analysis of quantum computing application to Higgs boson reconstruction at the large Hadron Collider

With the advent of the High-Luminosity Large Hadron Collider (HL-LHC) era, high energy physics (HEP) event selection will require new approaches to rapidly and accurately analyze vast databases. The current study addresses the enormity of HEP databases in an unprecedented manner—a quantum search using Grover’s Algorithm (GA) on an unsorted database, ATLAS Open Data, from the ATLAS detector. A novel method to identify rare events at 13 TeV in CERN’s LHC using quantum computing (QC) is presented. As indicated by the Higgs boson decay channel H→ZZ*→4l , the detection of four leptons in one event may be used to reconstruct the Higgs boson and, more importantly, evince Higgs boson decay to some new phenomena, such as H→ZZ d →4l . Searching the dataset for collisions resulting in detection of four leptons using a Jupyter Notebook, a classical simulation of GA, and several quantum computers with multiple qubits, the current application was found to make the proper selection in the unsorted dataset. Quantum search efficacy was analyzed for the incoming HL-LHC by implementing the QC method on multiple classical simulators and IBM’s quantum computers with the IBM Qiskit Open Source Software. The current QC application provides a novel, high-efficiency alternative to classical database searches, demonstrating its potential utility as a rapid and increasingly accurate search method in HEP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of Infrared Free-Induction Decay and Optical Nutation Signals from Nitrous Oxide Using a Current Modulated Quantum Cascade Laser

Free induction decay (FID), optical nutation and rapid passage induced (RP) signals in nitrous oxide, under both optically thin and optically thick conditions, have been observed using a rapid current pulse modulation, or chirp, applied to the slow current ramp of a quantum cascade (QC) laser. The variation in optical depth was achieved by increasing the pressure of nitrous oxide in a long pathlength multipass absorption cell. This allows the variation of optical depth to be achieved over a range of low gas pressures. Since, even at the highest gas pressure used in the cell, the chirp rate of the QC laser is faster than the collisional reorientation time of the molecules, there is minimal collisional damping, allowing a large macroscopic polarization of the molecular dipoles to develop. This is referred to as rapid passage induced gain. The resultant FID signals are enhanced due to the constructive interference between the field within the gas generated by the slow ramp of the laser (pump), and the fast chirp of the laser (probe) signal generated by pulse modulation of the continuously operating QC laser. The FID signals obtained at large 2 optical depth have not been observed previously in the mid-infrared regions, and unusual oscillatory signals have been observed at the highest gas pressures used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical investigation of edge plasma phenomena in an enhanced D-alpha discharge at Alcator C-Mod: Parallel heat flux and quasi-coherent edge oscillations

Reduced-model scrape-off layer turbulence (SOLT) simulations of an enhanced D-alpha (EDA) H-mode shot observed in the Alcator C-Mod tokamak were conducted to compare with observed variations in the scrape-off-layer (SOL) width of the parallel heat flux profile. In particular, the role of the competition between sheath- and conduction-limited parallel heat fluxes in determining that width was studied for the turbulent SOL plasma that emerged from the simulations. The SOL width decreases with increasing input power and with increasing separatrix temperature in both the experiment and the simulation, consistent with the strong temperature dependence of the parallel heat flux in balance with the perpendicular transport by turbulence and blobs. The particularly strong temperature dependence observed in the case analyzed is attributed to the fact that these simulations produce SOL plasmas which are in the conduction-limited regime for the parallel heat flux. A persistent quasi-coherent (QC) mode dominates the SOLT simulations and bears considerable resemblance to the QC mode observed in C-Mod EDA operation. The SOLT QC mode consists of nonlinearly saturated wave-fronts located just inside the separatrix that are convected poloidally by the mean flow, continuously transporting particles and energy and intermittently emitting blobs into the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-infrared light emission from a Fe{sup 2+}:ZnSe polycrystal using quantum cascade laser pumping

We report the realization of light emission from a Fe{sup 2+} doped ZnSe polycrystal with efficient pumping from a quantum cascade (QC) laser. The QC laser photon energy is near the absorption edge of the Fe{sup 2+}:ZnSe with less than ∼60 meV Stokes' shift. The Fe{sup 2+}:ZnSe polycrystal shows an absorption band of ∼2.2 – 5 μm in the mid-infrared (mid-IR) at room temperature, which narrows down to ∼2.4–4.2 μm at 80 K. Clear photoluminescence (PL) from 4.5 μm to 6 μm are observed throughout the temperature range of 300 K to 80 K. At room temperature, the luminescence lifetime is about 0.38 ± 0.1 μs which increases up to 101 ± 2 μs at 118 K. This system transfers energy stored in the upper state of a QC laser with ∼ps lifetime to the Fe{sup 2+}:ZnSe with 10{sup 5} to 10{sup 8} times longer lifetime, at the cost of minute photon energy losses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum cascade emission in the III-nitride material system designed with effective interface grading

We report the realization of quantum cascade (QC) light emission in the III-nitride material system, designed with effective interface grading (EIG). EIG induces a continuous transition between wells and barriers in the quantum confinement, which alters the eigenstate system and even delocalizes the states with higher energy. Fully transverse-magnetic spontaneous emission is observed from the fabricated III-nitride QC structure, with a center wavelength of ∼4.9 μm and a full width at half maximum of ∼110 meV, both in excellent agreement with theoretical predictions. A multi-peak photo-response spectrum is also measured from the QC structure, which again agrees well with theoretical calculations and verifies the effects of EIG.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Terahertz quantum-cascade patch-antenna VECSEL with low power dissipation

We report a terahertz quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL) based upon a metasurface consisting of an array of gain-loaded resonant patch antennas. Compared with the typical ridge-based metasurfaces previously used for QC-VECSELs, the patch antenna surface can be designed with a much sparser fill factor of gain material, which allows for reduced heat dissipation and improved thermal performance. Here, it also exhibits larger amplification thanks to enhanced interaction between the incident radiation and the QC-gain material. We demonstrate devices that produce several milliwatts of continuous-wave power in a single mode at ~4.6 THz and dissipate less than 1 W of pump power. Use of different output couplers demonstrates the ability to optimize device performance for either high power or high operating temperature. Maximum demonstrated power is 6.7 mW at 4 K (0.67% wall-plug efficiency, WPE) and 0.8 mW at 77 K (0.06% WPE). Directive output beams are measured throughout with divergence angles of ~5°.

47 OTHER INSTRUMENTATION↗

Statistical analysis of the Nb 3 Sn strand production for the ITER toroidal field coils

The ITER toroidal field (TF) strand procurement initiated the largest Nb 3 Sn superconducting strand production hitherto. The industrial-scale production started in Japan in 2008 and finished in summer 2015. Six ITER partners (so-called Domestic Agencies, or DAs) are in charge of the procurement and involved eight different strand suppliers all over the world, of which four are using the bronze route (BR) process and four the internal-tin (IT) process. In total more than 500 tons have been produced including excess material covering losses during the conductor manufacturing process, in particular the cabling. The procurement is based on a functional specification where the main strand requirements like critical current, hysteresis losses, Cu ratio and residual resistance ratio are specified but not the strand production process or layout. We introduce the analysis on the data acquired during the quality control (QC) process that was carried out to ensure the same conductor performance requirements are met by the different strand suppliers regardless of strand design. The strand QC is based on 100% billet testing and on applying statistical process control (SPC) limits. Throughout the production, samples adjacent to the strand pieces tested by the suppliers are cross-checked ('verified') by their respective DAs reference labs. The level of verification was lowered from 100% at the beginning of the procurement progressively to approximately 25% during the final phase of production. Based on the complete dataset of the TF strand production, an analysis of the SPC limits of the critical strand parameters is made and the related process capability indices are calculated. In view of the large-scale production and costs, key manufacturing parameters such as billet yield, number of breakages and piece-length distribution are also discussed. Furthermore, the results are compared among all the strand suppliers, focusing on the difference between BR and IT processes. Following the completion of the largest Nb 3 Sn strand production, our experience gained from monitoring the execution of the QC activities and from auditing the results from the measurements is summarised for future superconducting strand material procurement activities.

Vostner, A.↗

Cold ion beam in a storage ring as a platform for large-scale quantum computers and simulators: Challenges and directions for research and development

The purpose of this paper is to evaluate the possibility of constructing a large-scale storage-ring-type ion-trap system capable of storing, cooling, and controlling a large number of ions as a platform for scalable quantum computing (QC) and quantum simulations. In such a trap, the ions form a crystalline beam moving along a circular path with a constant velocity determined by the frequency and intensity of the cooling lasers. In this paper, we consider a large leap forward in terms of the number of ions that serve as qubits in QC, from fewer than 100 available in state of the art linear ion-trap devices today to an order of 10 5 crystallized ions in the storage-ring setup. This new trap design unifies two different concepts: the storage rings of charged particles and the linear ion traps used for QC and mass spectrometry. In this paper, we use the language of particle accelerators to discuss the ion state and dynamics. We outline the differences between the above concepts, analyze challenges of the large ring with a revolving chain of ions, and propose goals for the research and development required to enable future quantum computers with 1000 times more qubits than available today. The challenge of creating such a large-scale quantum system while maintaining the necessary coherence of the qubits and the high fidelity of quantum logic operations is significant. Performing analog quantum simulations may be an achievable initial goal for such a device. Quantum calculations and simulations of complex quantum systems will move forward both the fundamental science and the applied research. Nuclear and particle physics, many-body quantum systems, lattice gauge theories, and nuclear structure calculations are just a few examples in which a large-scale quantum simulation system will become a very powerful tool to move forward our understanding of nature.

36 MATERIALS SCIENCE↗

Evaluating a quantum-classical quantum Monte Carlo algorithm with Matchgate shadows

Solving the electronic structure problem of molecules and solids to high accuracy is a major challenge in quantum chemistry and condensed matter physics. The rapid emergence and development of quantum computers offer a promising route to systematically tackle this problem. Recent work by [Huggins et al ., Nature (London) 603 , 416 (2022)] proposed a hybrid quantum-classical quantum Monte Carlo (QC-QMC) algorithm using Clifford shadows to determine the ground state of a Fermionic Hamiltonian. This approach displayed inherent noise resilience and the potential for improved accuracy compared to its purely classical counterpart. Nevertheless, the use of Clifford shadows introduces an exponentially scaling postprocessing cost. In this work, we investigate an improved QC-QMC scheme utilizing the recently developed Matchgate shadows technique [Commun. Math. Phys. 404 , 629 (2023)], which removes the aforementioned exponential bottleneck. We observe from experiments on quantum hardware that the use of Matchgate shadows in QC-QMC is inherently noise robust. We show that this noise resilience has a more subtle origin than in the case of Clifford shadows. Nevertheless, we find that classical postprocessing, while asymptotically efficient, requires hours of runtime on thousands of classical CPUs for even the smallest chemical systems, presenting a major challenge to the scalability of the algorithm.

Monte Carlo methods↗

Quantum Computing and Visualization Research Challenges and Opportunities

Here, quantum computing (QC) has experienced rapid growth in recent years with the advent of robust programming environments, readily accessible software simulators and cloud-based QC hardware platforms, and growing interest in learning how to design useful methods that leverage this emerging technology for practical applications. From the perspective of the field of visualization, this article examines research challenges and opportunities along the path from initial feasibility to practical use of QC platforms applied to meaningful problems.

Data visualization↗

Tolerance levels of EPID-based quality control for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) includes features such as a variable dose rate and gantry speed in addition to the beam modulation achieved with multileaf collimator (MLC) motion patterns employed in intensity modulated radiotherapy. Three tests have previously been proposed for the evaluation of the performance of VMAT delivery. In order to enable a convenient and accurate routine machine quality control (QC) program, the present study proposes tolerance levels for these tests based on a department-wide implementation of an electronic portal imaging device (EPID)-based QC. Methods: Three different VMAT tests--a picket fence (PF) test, a dose rate versus gantry speed (DRGS) test, and a dose rate versus MLC leaf speed (DRMLC) test--were performed on nine accelerators using two different EPIDs (aS1000 and aS500, Varian Medical Systems). All tests were repeated six times for each accelerator. The images were analyzed using an in-house-developed software. For the PF test, the positions and widths of individual MLC leaf gaps were compared to the mean value. In the DRGS and DRMLC tests, different combinations of dose rate, gantry speed, and MLC leaf speed were used to deliver identical doses to separate parts of the EPID. The tests were evaluated by looking for deviations in the constancy of the measured dose for the preset combinations of dose rate, gantry speed, and MLC leaf speed. Results: For the PF test, a 0.3 mm tolerance level was suggested for the positioning of the MLC leaves. The tolerance level for the gap width was 0.5 mm. For the DRGS and DRMLC tests, a 3% tolerance level was proposed. Conclusions: With the adapted levels of tolerance for an EPID-based approach, the PF, the DRGS, and the DRMLC tests offer a convenient and accurate machine QC program for linear accelerators used for VMAT.

07 ISOTOPE AND RADIATION SOURCES↗

Automated radiotherapy treatment plan integrity verification

Purpose: In our clinic, physicists spend from 15 to 60 min to verify the physical and dosimetric integrity of radiotherapy plans before presentation to radiation oncology physicians for approval. The purpose of this study was to design and implement a framework to automate as many elements of this quality control (QC) step as possible. Methods: A comprehensive computer application was developed to carry out a majority of these verification tasks in the Philips PINNACLE treatment planning system (TPS). This QC tool functions based on both PINNACLE scripting elements and PERL sub-routines. The core of this technique is the method of dynamic scripting, which involves a PERL programming module that is flexible and powerful for treatment plan data handling. Run-time plan data are collected, saved into temporary files, and analyzed against standard values and predefined logical rules. The results were summarized in a hypertext markup language (HTML) report that is displayed to the user. Results: This tool has been in clinical use for over a year. The occurrence frequency of technical problems, which would cause delays and suboptimal plans, has been reduced since clinical implementation. Conclusions: In addition to drastically reducing the set of human-driven logical comparisons, this QC tool also accomplished some tasks that are otherwise either quite laborious or impractical for humans to verify, e.g., identifying conflicts amongst IMRT optimization objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

TU-A-18C-01: ACR Accreditation Updates in CT, Ultrasound, Mammography and MRI

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, the ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, mammography, ultrasound, and computed tomography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program. To understand the new requirements of the ACR ultrasound accreditation program, and roles the physicist can play in annual equipment surveys and setting up and supervising the routine QC program. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process.

60 APPLIED LIFE SCIENCES↗