Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Utility Experience with Inverter-Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. This report identifies various protection challenges due to IBRs that industry is facing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY24 – FY25 Efforts to Revive the ANS-54.8 Liquid Metal Fire Protection in LMR Plants Standard

The current multi-year effort seeks to utilize national laboratory support from Argonne to expedite revival of the ANS-54.8 standard titled “Liquid Metal Fire Protection in LMR Plants.” To achieve that objective, the following tasks were identified: Task 1 involves working directly with ANS to revive the ANS-54.8 Working Group. This was to be accomplished by completing necessary paperwork, submitting that paperwork to ANS for approval, enlisting potential working group members from industry, the NRC, national laboratories, and universities, and organizing and leading Working Group activities. The overall purpose of the Working Group is to develop an updated draft of ANS-54.8 for review and approval by ANS consensus committees, the ANS Standards Board, and certification from ANSI. Task 2 focuses on leveraging historical information and expertise at Argonne related to sodium fire protection systems and strategies. For more than a decade, Argonne has worked on both international and domestic projects related to sodium fire protection system development and evaluation. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group on important considerations that may be addressed in an updated draft of ANS-54.8. Task 3 focuses on leveraging Argonne experience in the development of and use of analysis methods and tools for the simulation of sodium fire scenarios and evaluation of the effectiveness of sodium fire protection systems and strategies. For more than a decade, Argonne has recovered, modified, and utilized several historical sodium fire analysis software tools. The goal of this task is to utilize that experience to help inform the ANS-54.8 Working Group of best practices for sodium fire progression analysis that may be addressed in an updated draft of ANS-54.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanolipoprotein particle (NLP) vaccine confers protection against Yersinia pestis aerosol challenge in a BALB/c mouse model

Introduction: Yersinia pestis is the etiological agent of plague, a disease that remains a concern as demonstrated by recent outbreaks in Madagascar. Infection with Y. pestis results in a rapidly progressing illness that can only be successfully treated with antibiotics given shortly after symptom onset. Live attenuated or whole cell inactivated vaccines confer protection against bubonic plague, but pneumonic plague has been more difficult to prevent. Novel effective subunit vaccine formulations may circumvent some of these shortfalls. Here, we compare the immunogenicity generated by an advanced subunit vaccine (F1V fusion protein) and a nanolipoprotein particle (NLP)-based vaccine. Methods: The NLP, a high-density lipoprotein mimetic, provides a nanoscale delivery platform for recombinant Y. pestis antigens LcrV (V) and F1. BALB/c mice were immunized via subcutaneous injection twice, three or four weeks apart. Four weeks later, splenocytes and sera were collected for immune profiling, and mice were challenged with aerosolized Y. pestis CO92. Results: Both formulations induced a strong IgG response against the F1 and V proteins, along with a robust memory B cell response and a balanced cell-mediated immune response as evidenced by both Th1- and Th2-related cytokines. The NLP-based vaccine induced a stronger cytokine response against F1, V, and F1V proteins relative to the F1V vaccine. As with F1V, the inclusion of Alhydrogel (Alu) in NLP vaccine formulations was critical for enhanced immunogenicity and protective efficacy. Mice that received two doses of F1:V:NLP + Alu and CpG were completely protected from a challenge with approximately eight median lethal doses of aerosolized Y. pestis CO92 and this protection confirmed the well-documented synergy between the F1 and V antigens in context of pneumonic plague. The NLPs have defined regions of polarity that facilitates the incorporation of a wide range of adjuvants and antigens with distinct physicochemical properties and are an excellent candidate platform for the development of multi-antigen vaccines.

F1↗

An mRNA vaccine encoding the Ebola virus glycoprotein induces high neutralizing antibody titers and provides strong protection against lethal infections in mouse models

Ebola virus (EBOV) is the causative agent of Ebola disease (EBOD), a viral hemorrhagic fever with a notably high case fatality rate. Current treatments for EBOD are limited to monoclonal antibodies or two licensed viral vector vaccines, a recombinant vesicular stomatitis virus (rVSV)-vectored vaccine or an adenovirus and modified vaccinia Ankara regimen. However, comparisons of protection, efficacy, and durability with alternative nucleotide platforms remain understudied. Here, we evaluated the immunogenicity of an mRNA vaccine expressing the EBOV glycoprotein (GP) in parallel with rVSV- and DNA-based vaccine platforms. The mRNA EBOV-GP vaccine, formulated in lipid nanoparticles, elicited significantly higher levels of total IgG and neutralizing antibody titers compared to the rVSV-EBOV-GP vaccine. Linear antibody epitope analysis indicated a preference for targeting the mucin-like domain in EBOV-GP1 following rVSV-based vaccination, while the mRNA platform distinctly targeted the internal fusion loop of EBOV-GP2. After characterizing the immunogenicity of the mRNA vaccine, two models of EBOD were used to demonstrate its protective efficacy: a surrogate rVSV-based challenge model of EBOD using type-I interferon deficient C57BL/6 mice and infection of BALB/c mice with authentic mouse-adapted EBOV. In both studies, the EBOV mRNA vaccine fully protected the mouse cohorts against morbidity and mortality. Additionally, the EBOV mRNA vaccine produced greater neutralizing antibody titers compared to the DNA EBOV-GP vaccine. These results suggest that an mRNA vaccine expressing EBOV-GP can induce robust, functional humoral responses that are protective against EBOD, warranting further development as an alternative to, or as part of a vaccine strategy including, viral vectored vaccines.

DNA vaccines↗

African Swine Fever Vaccine Candidate ASFV-G-ΔI177L Produced in the Swine Macrophage-Derived Cell Line IPKM Remains Genetically Stable and Protective against Homologous Virulent Challenge

ASFV vaccine candidate ASFV-G-ΔI177L has been shown to be highly efficacious in inducing protection against challenges with the parental virus, the Georgia 2010 isolate, as well as against field strains isolated from Vietnam. ASFV-G-ΔI177L has been shown to produce protection even when used at low doses (10 2 HAD 50 ) and shows no residual virulence even when administered at high doses (10 6 HAD 50 ) or evaluated for a relatively long period of time (6 months). ASFV-G-ΔI177L stocks can only be massively produced in primary cell macrophages. Alternatively, its modified version (ASFV-G-ΔI177L/ΔLVR) grows in a swine-derived cell line (PIPEC), acquiring significant genomic modifications. We present here the development of ASFV-G-ΔI177L stocks in a swine macrophage cell line, IPKM, and its protective efficacy when evaluated in domestic pigs. Successive passing of ASFV-G-ΔI177L in IPKM cells produces minimal genomic changes. Interestingly, a stock of ASFV-G-ΔI177L obtained after 10 passages (ASFV-G-ΔI177Lp10) in IPKM cells showed very small genomic changes when compared with the original virus stock. ASFV-G-ΔI177Lp10 conserves similar growth kinetics in primary swine macrophage cultures than the original parental virus ASFV-G-ΔI177L. Pigs infected with 10 3 HAD 50 of ASFV-G-ΔI177Lp10 developed a strong virus-specific antibody response and were completely protected against the challenge with the parental virulent field isolate Georgia 2010. Therefore, IPKM cells could be an effective alternative for the production of ASFV vaccine stocks for those vaccine candidates exclusively growing in swine macrophages.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the Reversion to Virulence and Protective Efficacy in Pigs Receiving the Live Attenuated Classical Swine Fever Recombinant Vaccine Candidate FlagT4G

Background/Objectives: Control of classical swine fever virus (CSFV) in endemic countries relies on vaccination using live attenuated vaccines (LAVs). Most of these LAVs do not allow for the differentiation of vaccinated animals from infected animals (DIVA) based on their serological response. FlagT4G vaccine is a novel candidate that confers robust protective immunity early after vaccination and shows DIVA capabilities. Methods: This report presents the characterization of FlagT4G virus in terms of the stability of its genomic and attenuated phenotypes assessed by a reversion to virulence protocol, as well as its protective efficacy by determining the minimal protective dose. Results: Results presented here demonstrate that after five consecutive passages in groups of 5-week-old susceptible domestic pigs, FlagT4G virus remains genetically stable, and its attenuated phenotype remains unaltered. In terms of efficacy, FlagT4G virus induced solid protection against the intranasal challenge with 105 tissue culture infectious dose (TCID50) of virulent field isolate Brescia virus, even with a vaccine dose as low as 102 TCID50. Conclusions: Results presented here indicate that the FlagT4G vaccine may be a useful tool for CSFV control.

Immunology↗

Bit error protection in cache memories

A computing device having a cache memory that is configured in a write-back mode is described. A cache controller in the cache memory acquires, from a record of bit errors that are present in each of a plurality of portions of the cache memory, a number of bit errors in a portion of the cache memory. The cache controller detects a coherency state of data stored in the portion of the cache memory. Based on the coherency state and the number of bit errors, the cache controller selects an error protection from among a plurality of error protections. The cache controller uses the selected error protection to protect the data stored in the portion of the cache memory from errors.

Kalamatianos, John↗

Adaptive Protective Relay Settings – A Vision to the Future

Adaptive relaying utilizes the continuously changing status of the power system as the basis for online adjustment of the power system relay settings. Fundamentally they are protection schemes that adjust settings and/or logic of operations based on the prevailing conditions of the system. These adjustments can include, but are not limited to, the logging of data for post-mortem analysis, communication throughout the system, as well as changing relay parameters. Adaptive relaying considers the fact that the status of a power system can change. These include system configuration changes, load effect, cold load pickup, end-of-line protection, transformer protection, and automatic reclosing. In this research, the author focus on the need for a secure, selective, and reliable system for adaptive overcurrent protection in T&D and Distributed Energy Systems. Various types of adaptive methods are presented and explained along with some pros and cons of each.

Mukherjee, Srijib↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Statistical Spread of Transmission Outages on a Fast Protection Time Scale Based on Utility Data

When there is a fault, the protection system automatically removes one or more transmission lines on a fast time scale of less than one minute. The outaged lines form a pattern in the transmission network. We extract these patterns from utility outage data, determine some key statistics of these patterns, and then show how to generate new patterns consistent with these statistics. The generated patterns provide a new and easily feasible way to model the overall effect of the protection system at the scale of a large transmission system. This new data-driven generative modeling of protection is expected to contribute to simulations of disturbances in large grids so that they can better quantify the risk of blackouts. Analysis of the pattern sizes suggests an index that describes how much outages spread in the transmission network at the fast timescale.

Transmission↗

Full-Set Transformer Protection Barrier Manufacturing and Technology

This Technology Commercialization Fund (TCF) project provided the design, fabrication, and testing a full-scale prototype “Corner Unit” protective barrier to provide seamless 360° perimetrical protection for highly expensive power generation or transmission infrastructure. The Corner Unit will seamlessly match up to the existing A-Frame design to form the 360° protection desired from industry. This TCF project also demonstrated how commercial industry could fabricate and deliver the full-scale barriers to remote locations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

RCT: Module 2.07 Respiratory Protection [Slides]

Internal dosimetry controls require the use of engineering controls to prevent the internal deposition of radioactive and non-radiological contaminants. However, when engineering and administrative controls are not available or feasible, respiratory protection may be necessary. The RCT should know and apply the considerations used in determining the respiratory protection equipment that is most appropriate for the job. The inappropriate use of or the use of the wrong respiratory protection equipment may result in undesirable health effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Industry's Long-term, Yet Near-term, Issues: The Need for Radiation Protection Professionals - 20266

Since the discovery of X-rays and radioactivity, the civil use of nuclear technology has thrived for more than a half-century and has matured to be safer and more efficient. A balance between radiological and non-radiological knowledge and experience has been gained and retained through the years. Nevertheless, a slowly developing gap has emerged during the past few decades. National and international data show a declining trend in the existence of health physics programs and associated enrollment and training, which directly impact the pipeline of radiation professionals (i.e., educators, technicians, researchers, and regulators). This decline can be attributed to many factors including the lack of scientific inquisitiveness, declining funding, and the perception that existing protocols are sufficiently protective. Decommissioning and dismantling nuclear facilities is a complex and multi-phased process that generates large quantities of various levels of radioactive waste. With multiple facilities reaching their end of operational life, and others being shut down for economic reasons, the current pipeline for radiation protection experts cannot meet the future's need. Consequently, international organizations have proposed a variety of programs to transfer knowledge of radiation protection principles and practice. While many change-oriented efforts to counteract this trend aim to promote mobility, this is just a partial solution to the actual issue: long-term availability. This paper suggests multidisciplinary collaborations with modern technologies as a path forward to educate young professionals on the diversity of radiation-related applications to retain expert knowledge and foster innovation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of leading edge protection application on wind turbine performance through energy and power decomposition approaches

Abstract Wind power production is driven by, and varies with, the stochastic yet uncontrollable wind and environmental inputs. To compare a wind turbine's performance, a direct comparison on power outputs is always confounded by the stochastic effect of weather inputs. It is therefore crucial to control for the weather and environmental influence. Toward that objective, our study proposes an energy decomposition approach. We start with comparing the change in the total energy production and refer to the change in total energy as delta energy. On this delta energy, we apply our decomposition method, which is to separate the portion of energy change due to weather effects from that due to the turbine itself. We derive a set of mathematical relationships allowing us to perform this decomposition and examine the credibility and robustness of the proposed decomposition approach through extensive cross‐validation and case studies. We then apply the decomposition approach to Supervisory Control and Data Acquisition data associated with several wind turbines to which leading‐edge protection was carried out. Our study shows that the leading‐edge protection applied on blades may cause a small decline to the power production efficiency in the short term, although we expect the leading‐edge protection to benefit the blade's reliability in the long term.

17 WIND ENERGY↗

End-to-end microgrid protection using distributed data-driven methods

This paper introduces an end-to-end microgrid protection framework that offers real-time system monitoring, fault-related decision making, and circuit breaker control. This is achieved through the design of distributed data-driven techniques based on the support vector machine method, where each relay is responsible for distributed data collection, fault detection, fault localization, and fault isolation. Local communication is established among neighboring relays, fostering cooperative fault localization and isolation. This decentralized design not only reduces the computational and communication requirements but also enables the adaptability of each relay under varying operational dynamics. The proposed end-to-end protection framework was validated using MATLAB/Simulink simulations on a 100% renewable microgrid, achieving an accuracy of 93.1% with response time of 0.0523 s, in protecting against a range of fault scenarios that are characterized by various types, locations, impedances, load conditions, photovoltaic power levels, and microgrid operating modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the impact of GIC neutral blocking devices on distance protection relay operations for transmission lines

Geomagnetic Induced Current (GIC) blocking devices typically include a capacitor on the neutral grounding path of wye-configured transformers. This type of GIC blocking device was designed as an effective countermeasure to prevent possible damages caused on the power grid by geomagnetic storms, and by the slow-varying component of a high-altitude electromagnetic pulse (HEMP). The insertion of a capacitor in the transformer neutral impedes the establishment of GICs in lines terminated with wye-connected transformer windings. With the presence of a capacitively grounded neutral, however, it becomes important to evaluate that no adverse effects are introduced in the general grid operations. In this context, this study investigates the impact of GIC neutral blocking devices on the functionality of distance protection relays for different values of transformer neutral blocking capacitors, and at different transmission line voltages. This study was conducted with a real-time simulation platform, and the simulations were performed by introducing a phase-to-ground fault at different line locations, and by measuring the apparent impedance at the protection relay location. Finally, the results indicated that, for typical values of capacitance considered for GIC neutral blocking devices, the distance protection relay model operates properly, without requiring a modification of the relay settings.

42 ENGINEERING↗