Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

X-ray fluorescence analysis for prediction of Space Shuttle solid rocket motor performance

Analysis of uncured solid propellant by X-ray fluorescence has been conducted on mixes prepared for four development motors produced for the Space Shuttle SRM Project. X-ray readings for chlorine (ammonium perchlorate) and iron (ferric oxide) were recorded for each mix during processing of the propellant. These values were used to predict burning rates for uncured acceptance, uncured acoustic emission and cured acoustic emission strands. Predicted burning rates all fell within control limits and when compared to actual burning rates, most were within experimental error. The X-ray analysis required one-third the time of current methods and met casting schedules.

Pulsipher, H. G.↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray/EUV optics for astronomy, microscopy, polarimetry, and projection lithography; Proceedings of the Meeting, San Diego, CA, July 9-13, 1990

Topics discussed in this issue include the fabrication of multilayer X-ray/EUV coatings; the design, characterization, and test of multilayer X-ray/EUV coatings; multilayer X-ray/EUV monochromators and imaging microscopes; X-ray/EUV telescopes; the test and calibration performance of X-ray/EUV instruments; XUV/soft X-ray projection lithography; X-ray/EUV space observatories and missions; X-ray/EUV telescopes for solar research; X-ray/EUV polarimetry; X-ray/EUV spectrographs; and X-ray/EUV filters and gratings. Papers are presented on the deposition-controlled uniformity of multilayer mirrors, interfaces in Mo/Si multilayers, the design and analysis of an aspherical multilayer imaging X-ray microscope, recent developments in the production of thin X-ray reflecting foils, and the ultraprecise scanning technology. Consideration is also given to an active sun telescope array, the fabrication and performance at 1.33 nm of a 0.24-micron-period multilayer grating, a cylindrical proportional counter for X-ray polarimetry, and the design and analysis of the reflection grating arrays for the X-Ray Multi-Mirror Mission.

Hoover, Richard B.↗

Project management techniques for highly integrated programs

The management and control of a representative, highly integrated high-technology project, in the X-29A aircraft flight test project is addressed. The X-29A research aircraft required the development and integration of eight distinct technologies in one aircraft. The project management system developed for the X-29A flight test program focuses on the dynamic interactions and the the intercommunication among components of the system. The insights gained from the new conceptual framework permitted subordination of departments to more functional units of decisionmaking, information processing, and communication networks. These processes were used to develop a project management system for the X-29A around the information flows that minimized the effects inherent in sampled-data systems and exploited the closed-loop multivariable nature of highly integrated projects.

Stewart, J. F.↗

Advancement of X-Ray Microscopy Technology and its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 micrometers can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Advancement of X-Ray Microscopy Technology and Its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 microns can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.↗

Thermal Environments and Margin Guidelines for NASA’s X-57 “Maxwell” Flight Demonstrator

NASA’s X-57 project includes development and flight demonstration of new electrified propulsion systems and equipment. The system components are designed to operate without active thermal management, which places increased emphasis on the ambient conditions as well as environmental stress screening for the newly designed equipment. Since the X-57 will not be operated outside of the Dryden Aeronautical Test Range at NASA’s Armstrong Flight Research Center, the X-57 team developed a series of reference atmospheres, described in this paper, based on the 2019 Edwards Range Reference Atmosphere to guide system development and testing. These four reference atmospheres include a standard day reference atmosphere that is identical to the 1976 U. S. Standard Atmosphere, a mean operational day atmosphere based on the mean 2019 Edwards Range Reference Atmosphere, and hot and cold day atmospheres based on the ±2σ yearly temperature variations in the Edwards Range Reference Atmosphere. As described herein, these reference atmospheres were then used to develop anticipated operational extremes for thermal cycle testing for the X-57 systems, which were developed from an amalgamation of two standards:SMC-S-016 and DO-160G. The project also adopted thermal margin guidance from SMC-S-016 to set requirements for the development of new electrified propulsion system components.

Thermal environments↗

The effects of a high luminosity radio galaxy on the ICM: ROSAT HRI observations of Cygnus A

The previously analyzed X-ray features of Cygnus A which coincide with the radio/optical core and radio hotspots are considered. Based on the Rosat high resolution imager (HRI) observations, the cavities in the projected X-ray surface brightness caused by the radio lobes and the excess emission from shocked inter-cluster medium (ICM) between the lobes and the bow shock are discussed. The data are compared to the predictions of an analytical model and of a 3D numerical simulation.

Harris, D. E.↗

Laser-wakefield accelerators for high-resolution X-ray imaging of complex microstructures

Laser-wakefeld accelerators (LWFAs) are high acceleration-gradient plasma-based particle accelerators capable of producing ultra-relativistic electron beams. Within the strong focusing felds of the wakefeld, accelerated electrons undergo betatron oscillations, emitting a bright pulse of X-rays with a micrometer-scale source size that may be used for imaging applications. Non-destructive X-ray phase contrast imaging and tomography of heterogeneous materials can provide insight into their processing, structure, and performance. To demonstrate the imaging capability of X-rays from an LWFA we have examined an irregular eutectic in the aluminum-silicon (Al-Si) system. The lamellar spacing of the Al-Si eutectic microstructure is on the order of a few micrometers, thus requiring high spatial resolution. We present comparisons between the sharpness and spatial resolution in phase contrast images of this eutectic alloy obtained via X-ray phase contrast imaging at the Swiss Light Source (SLS) synchrotron and X-ray projection microscopy via an LWFA source. An upper bound on the resolving power of 2.7±0.3μm of the LWFA source in this experiment was measured. These results indicate that betatron X-rays from laser wakefeld acceleration can provide an alternative to conventional synchrotron sources for high resolution imaging of eutectics and, more broadly, complex microstructures.

43 PARTICLE ACCELERATORS↗

X-57 Maxwell Aircraft

X-57 Project Need - Advance the Nation's ability to design, test, and determine airworthiness of distributed electric and aero-propulsive coupling technologies, which are a critical enabler of emerging, advanced air mobility markets. - The value of X-57 lies in advancing hte Nation's ability to design, test, and certify electric aircraft, which will enable entirely new markets - The Mod II flight test program is a pathfinder for the experimental propulsion system performance and reliability to reduce the risk in the X-57 configuration.

Heather Maliska↗

X-57 Maxwell Aircraft EMI/EMC Integration Lessons Learned

X-57 Project Need - Advance the Nation's ability to design, test, and determine airworthiness of distributed electric and aero-propulsive coupling technologies, which are a critical enabler of emerging, advanced air mobility markets. - The value of X-57 lies in advancing hte Nation's ability to design, test, and certify electric aircraft, which will enable entirely new markets - The Mod II flight test program is a pathfinder for the experimental propulsion system performance and reliability to reduce the risk in the X-57 configuration.

Heather Maliska↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

The pre-merger impact velocity of the binary cluster A1750 from X-ray, lensing, and hydrodynamical simulations

Since the discovery of the 'Bullet Cluster', several similar cases have been uncovered that suggest relative velocities well beyond the tail of high speed collisions predicted by the concordance ΛCDM model. However, quantifying such post-merger events with hydrodynamical models requires a wide coverage of possible initial conditions. Here, we show that it is simpler to interpret pre-merger cases, such as A1750, where the gas between the colliding clusters is modestly affected, so that the initial conditions are clear. We analyze publicly available Chandra data confirming a significant increase in the projected X-ray temperature between the two cluster centers in A1750 consistent with our expectations for a merging cluster. We model this system with a self-consistent hydrodynamical simulation of dark matter and gas using the FLASH code. Our simulations reproduce well the X-ray data and the measured redshift difference between the two clusters in the phase before the first core passage viewed at an intermediate projection angle. The deprojected initial relative velocity derived using our model is 1460 km s{sup –1}, which is considerably higher than the predicted mean impact velocity for simulated massive haloes derived by recent ΛCDM cosmological simulations, but is within the allowed range. Our simulations demonstrate that such systems can be identified using a multi-wavelength approach and numerical simulations, for which the statistical distribution of relative impact velocities may provide a definitive examination of a broad range of dark matter scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Science-based Acceleration of the Full Value Stream for Metal Additive Manufacturing (AM): Expedited Powder Development and Additive Manufacturing Deployment in the Area of Aluminum Alloys for AM Powder Production (Final Report)

The overall Science-based Acceleration of the Full Value Stream for Metal Additive Manufacturing (AM): Expedited Powder Development and Additive Manufacturing Deployment (“X-P4AM”) project objective is to drastically reduce the time-to-market barriers for new additive alloys of interest in automotive and aerospace applications, through computational alloy design with rapid screening and down- selection via synthesis of candidate alloys with rapid solidification. The project will also refine the technology in high pressure gas atomization to improve the production of commercial quantities of selected powders with high powder yields and enhanced powder quality. A new aluminum (Al) alloy based on an Al-Ce-X composition, enhanced powder production, and optimized AM build parameterization provided a critical step in widespread adoption of AM technology for automotive applications, in this case. The individual background and capabilities of the Party are ideally suited to the successful execution of this work. The included work enhanced the Contractors’ AM capabilities, a core competency of the Contractors, and developed a close working relationship with the Participant in the area of aluminum powder alloys and their end use.

36 MATERIALS SCIENCE↗

X-38 Application of Dynamic Inversion Flight Control

This paper summarizes the application of a nonlinear dynamic inversion (DI) flight control system (FCS) to an autonomous flight test vehicle in NASA's X-38 Project, a predecessor to the International Space Station (ISS) Crew Return Vehicle (CRV). Honeywell's Multi-Application Control-H (MACH) is a parameterized FCS design architecture including both model-based DI rate-compensation and classical P+I command-tracking. MACH was adopted by X-38 in order to shorten the design cycle time for different vehicle shapes and flight envelopes and evolving aerodynamic databases. Specific design issues and analysis results are presented for the application of MACH to the 3rd free flight (FF3) of X-38 Vehicle 132 (V132). This B-52 drop test, occurring on March 30, 2000, represents the first flight test of MACH and one of the first few known applications of DI in the primary FCS of an autonomous flight test vehicle.

Wacker, Roger↗

SU-E-QI-08: Fourier Properties of Cone Beam CT Projection

Purpose: To explore the Fourier properties of cone beam CT (CBCT) projections and apply the property to directly estimate noise level of CBCT projections without any prior information. Methods: By utilizing the property of Bessel function, we derivate the Fourier properties of the CBCT projections for an arbitrary point object. It is found that there exists a double-wedge shaped region in the Fourier space where the intensity is approximately zero. We further derivate the Fourier properties of independent noise added to CBCT projections. The expectation of the square of the module in any point of the Fourier space is constant and the value approximately equals to noise energy. We further validate the theory in numerical simulations for both a delta function object and a NCAT phantom with different levels of noise added. Results: Our simulation confirmed the existence of the double-wedge shaped region in Fourier domain for the x-ray projection image. The boundary locations of this region agree well with theoretical predictions. In the experiments of estimating noise level, the mean relative error between the theory estimation and the ground truth values is 2.697%. Conclusion: A novel theory on the Fourier properties of CBCT projections has been discovered. Accurate noise level estimation can be achieved by applying this theory directly to the measured CBCT projections. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011) and China Scholarship Council.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-303-03: A Scheme for Real-Time, Marker-Less and Low-Dose Tumor Tracking Using Scattering Imaging: Monte Carlo Simulation Study

Purpose: In-treatment tumor localization is critical for the management of tumor motion in lung cancer radiotherapy. Conventional tumor-tracking methods using a kV or MV x-ray projection has limited contrast. To facilitate real-time, marker-less and low-dose in-treatment image tumor tracking, we propose a novel scheme using Compton scatter imaging. This study reports Monte Carlo (MC) simulations on this scheme for the purpose of proof-of-principle. Methods: A slit x-ray beam along the patient superior-inferior (SI) direction is directed to the patient, intersecting the patient lung at a 2D plane containing majority part of the tumor motion trajectory. X-ray photons are scattered due to Compton effect from this plane, which are spatially collimated by, e.g., a pinhole, on one side of the plane and then captured by a detector behind it. The captured image, after correcting for x-ray attenuation and scatter angle variation, reflects the electron density, which allows visualization of the instantaneous anatomy on this plane. We performed MC studies on a phantom and a patient case for the initial test of this proposed method. Results: In the phantom case, the contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone-beam CT, and scattering image were 0.0625, 0.6993, and 0.5290, respectively. In the patient case, tumor motion can be clearly observed in the scatter images. Compared to fluoroscopy, scattering imaging also significantly reduced imaging dose because of its narrower beam design. Conclusion: MC simulation studies demonstrated the potential of the proposed scheme in terms of capturing the instantaneous anatomy of a patient on a 2D plane. Clear visualization of the tumor will probably facilitate ‘marker-less’ and ‘real-time’ tumor tracking with low imaging dose. NIH (1R01CA154747-01, 1R21CA178787-01A1 and 1R21EB017978-01A1)

60 APPLIED LIFE SCIENCES↗

X-57 Cruise Motor GVT Using Fixed-Base Correction Technique

The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) completed a modal survey of the X-57 Maxwell aircraft cruise motor system to help inform cruise motor redesign efforts. X-57 Maxwell was an electric propulsion demonstrator aircraft developed by NASA to inform airworthiness standards for electrified-aircraft. The cruise motor system modal survey was completed in spring of 2023 utilizing the fixed-base correction (FBC) ground vibration test (GVT) technique developed by ATA Engineering, to decouple the motor modes from the aircraft modes. Previously during the full aircraft GVT, a detailed modal assessment of the cruise motors was not performed. Owing to the X-57 project’s phase in the aircraft development cycle when the motor redesign effort occurred, the cruise motor GVT could only be performed with the cruise motor system installed on the aircraft, with most of its installation hardware (wiring, baffling, sensors, etc.) attached. An impact hammer was used to provide excitation input at various locations within the tight confines of the cruise motor installation. To better support motor redesign efforts, the FBC methodology was utilized to fix, separate and de-couple the cruise motor modes from aircraft modal response. During the GVT, this required additional impact tap tests on candidate fixed-boundary points for each degree of freedom (DOF) to be fixed. Additional triaxial accelerometers installed at the candidate points were used to compute frequency response functions (FRFs) in X, Y, and Z directions to enable those DOFs to be numerically fixed. Test data was acquired using Hottinger Brüel & Kjær’s LAN-XI data acquisition hardware and BK Connect software. FBC post-test processing was performed using the Structural Modification Using Frequency Response Functions (SMURF) technique with ATA Engineering’s Interface between MATLAB, Analysis, Test (IMAT) software. Utilizing the FBC technique relieved test engineers from having to instrument the entire aircraft to identify and separate aircraft response from cruise motor modes of interest. The FBC technique also permitted structural analysis engineers to omit secondary components from their finite element model (FEM) of the cruise motor system. This FBC modal survey was successful, and the first time NASA AFRC utilized the FBC method on an aircraft rather than a test fixture, and also using an impact hammer rather than multiple shakers allowing significant project schedule and cost savings

Modal Survey↗