At least 199 records · Page 11

Imaging gate-tunable Tomonaga–Luttinger liquids in 1H-MoSe 2 mirror twin boundaries

One-dimensional electron systems exhibit fundamentally different properties than higher-dimensional systems. For example, electron-electron interactions in one-dimensional electron systems have been predicted to induce Tomonaga-Luttinger liquid behaviour. Naturally occurring grain boundaries in single-layer transition metal dichalcogenides exhibit one-dimensional conducting channels that have been proposed to host Tomonaga-Luttinger liquids, but charge density wave physics has also been suggested to explain their behaviour. Clear identification of the electronic ground state of this system has been hampered by an inability to electrostatically gate such boundaries and tune their charge carrier concentration. Here we present a scanning tunnelling microscopy and spectroscopy study of gate-tunable mirror twin boundaries in single-layer 1H-MoSe 2 devices. Gating enables scanning tunnelling microscopy and spectroscopy for different mirror twin boundary electron densities, thus allowing precise characterization of electron-electron interaction effects. Visualization of the resulting mirror twin boundary electronic structure allows unambiguous identification of collective density wave excitations having two velocities, in quantitative agreement with the spin-charge separation predicted by finite-length Tomonaga-Luttinger liquid theory.

36 MATERIALS SCIENCE↗

Quantitative insights for diagnosing performance bottlenecks in lithium–sulfur batteries

Lithium–sulfur (Li–S) batteries hold significant promise for electric vehicles and aviation due to their high energy density and cost-effectiveness. However, understanding the root causes of performance degradation remains a formidable challenge, as the interplay of multiple factors obscures key failure mechanisms. A major limitation has been the inability to quantify soluble sulfur species within practical detection limits accurately and to correlate electrochemical processes with associated physical inventory changes. Here, we introduce the high-performance liquid chromatography-ultraviolet spectroscopy and gas chromatography sequential characterization (HUGS) toolkit, capable of precisely quantifying seven distinct sulfur and polysulfide species at concentrations as low as 40 ppb. HUGS has been successfully applied to practical coin and pouch cells without requiring cell modification. Furthermore, our self-developed software, Dr HUGS, enhanced the data analysis speed by over 30 times, enabling multi-source data integration and delivering comprehensive analysis results within minutes. Using HUGS, we identify significant capacity losses from inactive lithium and sulfur during initial cycles and sulfide-rich solid–electrolyte interphase (SEI) formation on the anode during later cycles. Notably, our findings reveal that soluble polysulfides have minimal contributions to capacity loss, challenging long-standing assumptions. Moreover, HUGS demonstrates that constant-pressure setups in Li–S pouch cells improve compositional uniformity compared to constant-gap configurations. For sulfurized polyacrylonitrile (SPAN) cathodes, unique issues such as non-sulfide SEI formation and lithium pulverization are observed, which can be mitigated through localized high-concentration electrolytes to enhance lithium inventory retention. By enabling precise quantification of critical inventory components, HUGS provides transformative insights into failure mechanisms across various electrolytes and cathode chemistries, guiding rational design strategies for next-generation energy storage systems.

25 ENERGY STORAGE↗

HD 191939: Three Sub-Neptunes Transiting a Sun-like Star Only 54 pc Away

We present the discovery of three sub-Neptune-sized planets transiting the nearby and bright Sun-like star HD 191939 (TIC 269701147, TOI 1339), a K {sub s} = 7.18 mag G8 V dwarf at a distance of only 54 pc. We validate the planetary nature of the transit signals by combining 5 months of data from the Transiting Exoplanet Survey Satellite with follow-up ground-based photometry, archival optical images, radial velocities, and high angular resolution observations. The three sub-Neptunes have similar radii (R{sub b}=3.42{sub −0.11}{sup +0.11}, R{sub c}=3.23{sub −0.11}{sup +0.11}, and R{sub d}=3.16{sub −0.11}{sup +0.11} R{sub ⊕}), and their orbits are consistent with a stable, circular, and coplanar architecture near mean-motion resonances of 1:3 and 3:4 (P {sub b} = 8.88, P {sub c} = 28.58, and P {sub d} = 38.35 days). The HD 191939 system is an excellent candidate for precise mass determinations of the planets with high-resolution spectroscopy due to the host star’s brightness and low chromospheric activity. Moreover, the system’s compact and near-resonant nature can provide an independent way to measure planetary masses via transit timing variations while also enabling dynamical and evolutionary studies. Finally, as a promising target for multiwavelength transmission spectroscopy of all three planets’ atmospheres, HD 191939 can offer valuable insight into multiple sub-Neptunes born from a protoplanetary disk that may have resembled that of the early Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

A Quantum Band Model of the nu3 Fundamental of Methanol (CH3OH) and Its Application to Fluorcescence Spectra of Comets

Methanol (CH3OH) radiates efficiently at infrared wavelengths, dominating the C-H stretching region in comets, yet inadequate quantum-mechanical models have imposed limits on the practical use of its emission spectra. Accordingly, we constructed a new line-by-line model for the 3 fundamental band of methanol at 2844 / cm (3.52 micron) and applied it to interpret cometary fluorescence spectra. The new model permits accurate synthesis of line-by-line spectra for a wide range of rotational temperatures, ranging from 10 K to more than 400 K.We validated the model by comparing simulations of CH3OH fluorescent emission with measured spectra of three comets (C/2001 A2 LINEAR, C/2004 Q2 Machholz and 8P/Tuttle) acquired with high-resolution infrared spectrometers at high-altitude sites. The new model accurately describes the complex emission spectrum of the nu3 band, providing distinct rotational temperatures and production rates at greatly improved confidence levels compared with results derived from earlier fluorescence models. The new model reconciles production rates measured at infrared and radio wavelengths in C/2001 A2 (LINEAR). Methanol can now be quantified with unprecedented precision and accuracy in astrophysical sources through high-dispersion spectroscopy at infrared wavelengths

Villanueva, Geronimo L.↗

HD 191939: Three Sub-Neptunes Transiting a Sun-like Star Only 54 pc Away

We present the discovery of three sub-Neptune-sized planets transiting the nearby and bright Sun-like star HD 191939 (TIC 269701147, TOI 1339), a Ks = 7.18 mag G8 V dwarf at a distance of only 54 pc. We validate the planetary nature of the transit signals by combining 5 months of data from the Transiting Exoplanet Survey Satellite with follow-up ground-based photometry, archival optical images, radial velocities, and high angular resolution observations. The three sub-Neptunes have similar radii (R(b)=3.42(+0.11,-0.11), R(c)=3.23(+0.11,-0.11), and R(d)=3.16(+0.11,-0.11 Rꚛ), and their orbits are consistent with a stable, circular, and coplanar architecture near mean-motion resonances of 1:3 and 3:4 (P(b) = 8.88, P(c) = 28.58, and P(d) = 38.35 days). The HD 191939 system is an excellent candidate for precise mass determinations of the planets with high-resolution spectroscopy due to the host star's brightness and low chromospheric activity. Moreover, the system's compact and near-resonant nature can provide an independent way to measure planetary masses via transit timing variations while also enabling dynamical and evolutionary studies. Finally, as a promising target for multiwavelength transmission spectroscopy of all three planets' atmospheres, HD 191939 can offer valuable insight into multiple sub-Neptunes born from a protoplanetary disk that may have resembled that of the early Sun.

Mariona Badenas-Agusti↗

Design Principles in Engineering of Multigrain Nanocatalysts via Multiscale Electronic Structure Characterization

Engineering grain boundary (GB) strain provides a promising pathway to tune the catalytic properties of nanocrystals. However, structural heterogeneity from random grain orientation and geometry has limited clear structure–property correlations. Here, we utilize a multigrain Co3O4/Mn3O4 core/shell nanocrystal platform as a model system to systematically investigate how geometric misfit strain at GBs serves as catalytically active sites for the oxygen reduction reaction. Through precise subnanometer-level control over grain morphology and by integrating multiscale electronic structure characterization, we identify the electronic structural signature of GB defects and establish a direct correlation between localized strain fields and modified electronic states. Strain modulation at GBs alters the eg orbital energy levels, with elongation along the z-axis combined with shear strain stabilizing the eg states, in contrast to the destabilization observed under pure shear strain. This stabilization mechanism enhances the electrocatalytic activity and selectivity of strained GBs compared with strain-relaxed grain surfaces. Furthermore, we reveal that GBs exhibit a radial strain gradient, producing a spatial energy shift that further modulates local electronic structures, as resolved through the classification of electron energy loss spectroscopy data. Together, these findings demonstrate that geometric misfit strain enables precise tuning of grain geometry and the resulting electronic structures, offering a robust strategy for engineering next-generation nanocatalysts.

Cho, Min Gee↗

Tracking oxygen vacancy migration in memristor devices using operando hard X-ray photoelectron spectroscopy

Fabrication of ultrathin (sub-2 nm) oxide semiconductor memristors poses the fundamental challenge of achieving oxide growth with atomic precision in terms of electronic structure and defect formation. Recently, ultrathin memristors consisting of bilayers of mixed Al 2 O 3 and MgO atomic layers were fabricated using an in vacuo atomic layer deposition process. This approach offers a unique platform for precise atomic control of oxygen vacancies in the device in which the vacancies are introduced by placing MgO atomic layers between pristine Al 2 O 3 layers. In this work, we present a systematic operando Hard X-ray PhotoElectron Spectroscopy (HAXPES) study of the switching of such memristors, combined with complementary current-voltage and capacitance-voltage (C-V) measurements. We used a memristor stack of Al 2 O 3 /MgO atomic layers, with the MgO-containing oxide deposited on the bottom Al metal electrode and a pure Al 2 O 3 layer below the top Pd electrode. HAXPES analysis shows a substantial change in the chemical shift of the Aluminum oxide when switching between the ”OFF” and ”ON” states indicative of a redistribution of oxygen vacancies in the device active layer. Interestingly, subsequent switching to the OFF state shows hysteretic behavior indicating the retention of some oxygen vacancies in the top Al 2 O 3 layer. This vacancy retention can be correlated with the stochastic behavior of the switching voltage observed in these devices. C–V measurements show a clear frequency-dependent response in the OFF state, consistent with enhanced polarization and vacancy trapping at low frequencies.

47 OTHER INSTRUMENTATION↗

Light Meson Spectroscopy with GlueX and Beyond

The GlueX experiment at Jefferson Lab was specifically designed for precision studies of the light-meson spectrum. For this purpose, a photon beam with energies up to 12 GeV is directed onto a liquid hydrogen target contained within a hermetic detector with near-complete neutral and charged particle coverage. Linear polarization of the photon beam with a maximum around 9 GeV provides additional information about the production process. In 2018, the experiment completed its first phase, recording data with a total integrated luminosity above 400 pb?1. We highlight a selection of results from this world-leading data set with emphasis on the search for light hybrid mesons. In the mean time, the detector underwent significant upgrades and is currently recording data with an even higher luminosity. The future plans of the GlueX experiment to explore the meson spectrum with unprecedented precision are summarized.

Austregesilo, Alexander↗

Laboratory spectroscopy in support of atmospheric measurements

Optical measurements of trace species in the atmosphere require precise, accurate spectroscopic data for the molecules under study. This laboratory exits to provide high quality spectroscopic data for the interpretation of data from existing satellite, balloon, ground, and aircraft instruments, as well as to provide sufficient data to assess the feasibility of new instruments.

Mcgee, Thomas J.↗

A Comprehensive Radial Velocity Error Budget for Next Generation Doppler Spectrometers

We describe a detailed radial velocity error budget for the NASA-NSF Extreme Precision Doppler Spectrometer instrument concept NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy). Such an instrument performance budget is a necessity for both identifying the variety of noise sources currently limiting Doppler measurements, and estimating the achievable performance of next generation exoplanet hunting Doppler spectrometers. For these instruments, no single source of instrumental error is expected to set the overall measurement floor. Rather, the overall instrumental measurement precision is set by the contribution of many individual error sources. We use a combination of numerical simulations, educated estimates based on published materials, extrapolations of physical models, results from laboratory measurements of spectroscopic subsystems, and informed upper limits for a variety of error sources to identify likely sources of systematic error and construct our global instrument performance error budget. While natively focused on the performance of the NEID instrument, this modular performance budget is immediately adaptable to a number of current and future instruments. Such an approach is an important step in charting a path towards improving Doppler measurement precisions to the levels necessary for discovering Earth-like planets.

NASA-NSF Extreme Precision Doppler Spectrometer in↗

Revisiting Discharge Mechanism of CF x as a High Energy Density Cathode Material for Lithium Primary Battery

Lithium/fluorinated graphite (Li/CFx) primary batteries show great promise for applications in a wide range of energy storage systems due to their high energy density (>2100 Wh kg –1 ) and low self-discharge rate (<0.5% per year at 25 °C). While the electrochemical performance of the CF x cathode is indeed promising, the discharge reaction mechanism is not thoroughly understood to date. In this article, a multiscale investigation of the CF x discharge mechanism is performed using a novel cathode structure to minimize the carbon and fluorine additives for precise cathode characterizations. Titration gas chromatography, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, cross-sectional focused ion beam, high-resolution transmission electron microscopy, and scanning transmission electron microscopy with electron energy loss spectroscopy are utilized to investigate this system. Results show no metallic lithium deposition or intercalation during the discharge reaction. Crystalline lithium fluoride particles uniformly distributed with <10 nm sizes into the CF x layers, and carbon with lower sp2 content similar to the hard-carbon structure are the products during discharge. This article deepens the understanding of CF x as a high energy density cathode material and highlights the need for future investigations on primary battery materials to advance performance.

25 ENERGY STORAGE↗

Exotic silicon phases synthesized through ultrashort laser-induced microexplosion: Characterization with Raman microspectroscopy

Exotic metastable phases of silicon formed under high pressure are expected to have attractive semiconducting properties including narrow band gaps that open up novel technological applications. Confined microexplosions induced by powerful ultrashort laser pulses have been demonstrated as an advanced tool for the creation of new high-pressure phases that cannot be synthesized by other means. Tightly focused laser pulses are used to generate localized modifications inside the material structure, providing the possibility for precise controlled band-gap engineering. In this study, noninvasive Raman spectroscopy was used for analysis of laser-modified zones in silicon and to determine the metastable high-pressure phases contained. Low laser energies induced the formation of amorphous-only silicon, while higher energies led to crystalline silicon polymorphs within the modifications, albeit under considerable residual stress up to 4.5 GPa. The presence of the structurally similar r8-Si, bc8-Si, and bt8-Si phases is revealed, as well as other yet to be identified phases, and the stacking-related 9R Si polytype is evidenced, presumably stress-induced by the highly compressed laser-modified zone. The ab initio random structure searching approach is used to calculate the Raman signatures and to help identify different Si polymorphs. The findings of this study by Raman spectroscopy from ultrashort laser-induced microexplosion sites may yield insights into the local structure and properties of new silicon metastable phases and the prospect of utilizing exotic phases for extending current applications.

36 MATERIALS SCIENCE↗

Laser Surface Preparation for Adhesive Bonding of Ti-6Al-4V

Adhesively bonded structures are potentially lighter in weight than mechanically fastened ones, but existing surface treatments are often considered unreliable. Two main problems in achieving reproducible and durable adhesive bonds are surface contamination and variability in standard surface preparation techniques. In this work three surface pretreatments were compared: laser etching with and without grit blasting and conventional Pasa-Jell treatment. Ti-6Al-4V surfaces were characterized by contact angle goniometry, optical microscopy, and X-ray photoelectron spectroscopy (XPS). Laser -etching was found to produce clean surfaces with precisely controlled surface topographies and PETI-5 lap shear strengths and durabilities were equivalent to those produced with Pasa-Jell.

Belcher, Marcus A.↗

The Origins Space Telescope Integration and Testing

This paper describes the plans, flows, key facilities, test beds, pathfinders, simulators and ground support equipment that could be used to fully integrate, functionally test and qualify the Origins Space Telescope (Origins). The Origins Observatory consists of the Spacecraft Bus Module (SBM) and the Cryogenic Payload Module (CPM), which comprises the telescope and three science instruments. The telescope is a Three Mirror Anastigmat (TMA) and is composed of four mirrors: three with optical power (the elliptical primary, hyperbolic secondary, and elliptical tertiary mirrors) and a flat field-steering mirror (FSM). The three science instruments spanning the wavelength range 2.8 to 588 μm provide the powerful new spectroscopic and imaging capabilities required to achieve the scientific objectives. The Origins Survey Spectrometer (OSS) uses six gratings in parallel to take multi-beam spectra simultaneously across the 25 to 588 μm window through long slits enabling deep 3D extra-galactic surveys. The Far-IR Imager/Polarimeter (FIP) provides imaging and polarimetric measurement capabilities at 50 and 250 μm. Its fast mapping enables rapid follow-up of transient or variable sources and efficient monitoring campaigns. The Mid-Infrared Spectrometer (MISC-T) provides spectroscopy simultaneously over 2.8 to 20 μm with exquisite stability and precision (<5 ppm between 2.8 to 10 μm, <20 ppm between 11 to 20 μm). All the instruments are delivered for Integration and Test fully qualified and calibrated. The Integration and Test program implemented at each level of assembly is discussed as well as the separation of thermal vacuum testing between the hot and cold zones of the Observatory. Portions of this manuscript appear in the Origins Study Final Report.

Origins↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution spectroscopy of barium monofluoride: Odd isotopologues, hyperfine structure, and isotope shifts

Barium monofluoride (BaF) is a promising molecular species for precision tests of fundamental symmetries and interactions. We present a combined theoretical and experimental study of BaF spectra and isotope shifts, focusing in particular on the poorly understood odd isotopologues 137 BaF and 135 BaF. By comparing state-of-the-art ab initio calculations with high-resolution fluorescence and absorption spectroscopy data, we provide a benchmark for electronic structure theory and disentangle the hyperfine and rovibrational spectra of the five most abundant isotopologues, from 138 BaF to 134 BaF. The comprehensive knowledge gained enables a King plot analysis of the isotope shifts that reveals the odd-even staggering of the barium nuclear charge radii. It also paths the way for improved laser cooling of rare BaF isotopologues and crucially supports future measurements of nuclear anapole and Schiff moments.

Kogel, Felix [Univ. of Stuttgart (Germany)] (ORCID↗