Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

The design of a complete vector measurement system being tested over 560-635 GHz is presented. The topics include: 1) Current State-of-the-Art in Vector Measurements; 2) Submillimeter Active Imaging Requirements; 3) 600 GHz Vector Measurement System; 4) 450 MHz IF Signal; 5) 450 MHz IF signal @ 1 kHz Res. BW; 6) 450 MHz IF Signal Mixed with Shifted 450 MHz Reference Signal; 7) Reference Signal Offset Generator; 8) Cavity Bandpass Filter; 9) Miniature Multistage Helical Filter; 10) X36 450 MHz Multiplier; 11) 600 GHz Test Setup; 12) 600 GHz Transmit Module; 13) 600 GHz Receive Module; 14) Performance Tests: Amplitude Stability & Dynamic Range; 15) Performance Tests: Phase Stability; 16) Stability at Imaging Bandwidths; 17) Phase Measurement Verification; and 18) The Next Step: Imaging.

phase measurements↗

Constant frequency pulsed phase-locked loop measuring device

A measuring apparatus is presented that uses a fixed frequency oscillator to measure small changes in the phase velocity ultrasonic sound when a sample is exposed to environmental changes such as changes in pressure, temperature, etc. The invention automatically balances electrical phase shifts against the acoustical phase shifts in order to obtain an accurate measurement of electrical phase shifts.

Yost, William T.↗

Phase-Locked Loop For Measurement Of Small And Large Delays

Electronic signal-generating and processing subsystem of ultrasonic inspection or measurement system consists mainly of variable-and-fixed-frequency, pulsed phase-locked loop (VFFPPLL) measuring phase shifts from 0 degrees to more than 360 degrees with accurancy of 0.112 degrees. VFFPPLL measures phase shifts between transmitted ultrasonic toneburst and its echo, thereby measuring ultrasonic-propagation delay. Used to determine strain in bolt or to track irregular surface of specimen being inspected ultrasonically.

Froggatt, Mark↗

Orbit determination of highly elliptical Earth orbiters using improved Doppler data-processing modes

A navigation error covariance analysis of four highly elliptical Earth orbits is described, with apogee heights ranging from 20,000 to 76,800 km and perigee heights ranging from 1,000 to 5,000 km. This analysis differs from earlier studies in that improved navigation data-processing modes were used to reduce the radio metric data. For this study, X-band (8.4-GHz) Doppler data were assumed to be acquired from two Deep Space Network radio antennas and reconstructed orbit errors propagated over a single day. Doppler measurements were formulated as total-count phase measurements and compared to the traditional formulation of differenced-count frequency measurements. In addition, an enhanced data-filtering strategy was used, which treated the principal ground system calibration errors affecting the data as filter parameters. Results suggest that a 40- to 60-percent accuracy improvement may be achievable over traditional data-processing modes in reconstructed orbit errors, with a substantial reduction in reconstructed velocity errors at perigee. Historically, this has been a regime in which stringent navigation requirements have been difficult to meet by conventional methods.

Estefan, J. A.↗

Unequal-Arms Michelson Interferometers

Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

Tinto, Massimo↗

Unequal-Arms Michelson Interferometers

Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time-shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detectors of gravitational radiation is discussed.

Tinto, Massimo↗

Unequal-Arms Michelson Interferometers

Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms.

Gravitational↗

Recent Improvements in the Beam Capture at Fermilab Booster for High Intensity Operation

The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by using its paraphase system. At the end of the capture the feedback is turned on for beam acceleration. It is vital for present operations as well as during the PIP-II era that both the HLRF and LLRF systems provide the proper intended phase and RF voltage to preserve the longitudinal emittance from injection to extraction. In this paper, we describe the original architecture of the cavity phase distribution, our recent beam-based RF phase measurements, observed significant deviation in the relative phases between cavities and correction effort. Results from the improved capture for high intensity beam are also presented.

43 PARTICLE ACCELERATORS↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of G-phase volume fraction and number density in duplex stainless steels using transmission electron microscopy

Duplex stainless steels (DSS) have a high toughness and strength due the presence of both austenitic and ferritic phases. These alloys have had limited use in power production applications due to thermal embrittlement caused by spinodal decomposition and development of G-phase precipitates in the ferrite. Lean grade DSS alloys (e.g., 2101, 2003) may offer improved thermal stability due to the reduction of Cr- and Ni-equivalent elements when compared to standard grade compositions (e.g., 2205, 2209). The abundance of the G-phase was measured in five duplex stainless steels, three wrought alloys (2101, 2003, 2205) and their matching filler metals (2101-w, 2209-w), after aging at 427 °C for 1000 h and 10,000 h. The G-phase volume fraction, number density, size, and precipitate spacing were found using quantitative analysis of transmission electron microscopy dark field images and the composition of G-phase precipitates on other clusters were characterized with atom probe tomography (APT). In the welded alloys, the G-phase was found to develop rapidly, relative to the wrought material. A positive correlation was found between the nickel equivalent composition of the alloy and the G-phase volume fraction. The alloys 2205, 2209, and 2101-w, which are higher in Cr and Ni, all showed significant G-phase precipitation, further strengthening the hypothesis that lean grade DSS alloys are more thermally stable against precipitation in the ferrite. Electron diffraction showed a secondary phase present in the 2101 wrought alloy at 10,000 h, but it was not crystallographically consistent with the G-phase; APT showed the presence of nanoclusters rich in both nickel and copper for this alloy. In conclusion, no secondary phases or clusters were found in 2003 after 10,000 h of aging, so it may be a candidate alloy for applications that require long-life times at high operating temperatures.

36 MATERIALS SCIENCE↗

Equivalent GPS measurements for efficient estimation process

Dual-frequency pseudorange and carrier phase data streams can be analytically combined into a single equivalent data stream, reducing the data volume and computing time in the filtering process for parameter estimation by a factor of 2 to 4. The resulting single data stream is that of carrier phase measurements with both data noise and bias uncertainty strictly defined. Based on these analytical formulas the equivalent GPS measurements can be formed by simple and efficient numerical calculations without any degradation in data strength. Formulation for the equivalent GPS measurements and their covariances are given in closed form; and a numerical simulation is performed to demonstrate the validity and effectiveness of the equivalent measurements.

Wu, S. C.↗

Lunar phase function effects on spectral ratios used for resource assessment

Groundbased telescopic CCD images of 36 selected locations on the moon were obtained in five 'standard' bandpasses at 12 phase angles ranging from -78 deg to +75 deg to measure phase function effects on the ratio values used to quantify the abundance of TiO2 and qualitatively indicate soil maturity. Consistent with previous studies, we find that the moon is 'bluer' at small phase angles, but that the effect on the ratio values for TiO2 abundance for the phase angles of our data is on the order of the measurement uncertainties throughout the range of abundances found in the mare. The effect is more significant as seen from orbiting spacecraft over a range of selenographic latitude. Spectral ratio images (400/560 and 400/730 nm) were used to map the abundance of TiO2 using the empirical relation found by Charlette et al from analysis of returned lunar soils. Additionally, the 950/560 and 950/730 nm image ratios were used to define the regions of mature mare soil in which the relation is valid. Although the phase function dependence on wavelength was investigated and quantified for small areas and the integrated disc, the effect specifically on TiO2 mapping was not rigorously determined. For consistency and convenience in observing the whole lunar front side, our mapping utilized images taken -15 deg less than alpha less than 15 deg when the moon was fully illuminated from earth; however, this includes the strong opposition peak.

Larson, S. M.↗

Simulations of wavelength-multiplexed holography for single-shot spatiotemporal characterization of NIF’s advanced radiographic capability (ARC) laser

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility’s Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

47 OTHER INSTRUMENTATION↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

An electro-optic resonant modulator for coherent optical communication

A resonant cavity electro-optic phase modulator has been designed and implemented to operate at a data rate of 10 Mbps. The modulator consists of an electro-optic crystal located in a highly resonant cavity. The cavity is electro-optically switched on and off resonance, and the phase dispersion near the cavity resonance provides the output phase modulation. The performance of the modulator was measured by first heterodyne detecting the signal to an intermediate frequency, and measuring the spectral characteristics using an RF spectrum analyzer. The measured phase shift is shown to be in good agreement with the theoretical predictions. Further theoretical analysis shows that the design of the modulator can be scaled to operate at 100 Mbps.

Robinson, D. L.↗