Requirements for Quality Management System for PV Module Manufacturing
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Current transferred from the active cell circuit to ground in modules undergoing potential-induced degradation (PID) stress is analyzed with respect to meteorological data. Duration and coulombs transferred as a function of whether the module is wet (from dew or rain) or the extent of uncondensed surface humidity are quantified based on meteorological indicators. With this, functions predicting the mode and rate of coulomb transfer are developed for use in estimating the relative PID stress associated with temperature, moisture, and system voltage in any climate. Current transfer in a framed crystalline silicon module is relatively high when there is no condensed water on the module, whereas current transfer in a thin-film module held by edge clips is not, and displays a greater fraction of coulombs transferred when wet compared to the framed module in the natural environment.
We report the results of analytical transmission electron microscopy studies of defects associated with potentialinduced degradation (PID) of a laboratory stressed multicrystalline silicon mini-module. Shunt defects were first identified using dark lock in thermography (DLIT) and scanning electron microscopy (SEM) electron beam induced current (EBIC) imaging. Transmission electron microscopy (TEM) crosssection samples were then prepared of selected shunt defects using conventional focused ion beam (FIB) lift out techniques and examined by TEM and scanning transmission electron microscopy (STEM). The defects were identified as {111} planar defects and compositional mapping of the defects revealed elevated levels of both Na, expected from previous work, and also surprisingly O at some of the defect cores.
Abstract not provided.
Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.
Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.
Abstract not provided.
Capabilities fact sheet for the National Center for Photovoltaics: Photovoltaic Reliability and Engineering. One-sided sheet that includes Scope, Core Competencies and Capabilities, and Contact/Web information.
The goal this project was to accelerate the deployment of innovative solar cell and module technologies that reduce the cost of PERC-based modules to best-in-class. New module integration technology was to be used to reduce the cost and reliance on conventional silver bus bar pastes and enhance cell efficiency. On the cell manufacturing front, the cost of PERC solar cells was to be reduced by introducing advanced metallization approaches to increase cell efficiency. These advancements will be combined with process optimization to target cell efficiencies in the range of 21 to 21.5%. This project will also explore the viability of a bifacial PERC solar cell design to enable cost savings through the use of thin silicon wafers. This project was terminated on 4/30/17 after four months of activity due financial challenges facing the recipient.
This was a collaborative effort between LLNS, as manager and operator of Lawrence Livermore National Laboratory ("LLNL"), and DNV GL PVEL, LLC, through its wholly-owned subsidiary of KEMA, USA, Inc., operating as a wholly-owned subsidiary of KEMA N.V., Arnhem, Netherlands, a Dutch company, which is a wholly-owned subsidiary of DNV GL, HØvik, Norway, a Norwegian company ("Participant"), to test a water measurement instrumentation developed by LLNL in support of a DOE-funded award.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.