Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

PV Performance Modeling - Data and Resources

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. This dataset includes seven MS-Excel sheets with instructions, notes and all necessary data (weather, irradiance, temperature, power) used for the data analysis of the blind modeling comparison. The hourly data represent six different systems from Albuquerque, NM and Roskilde, Denmark over a period of one year. These data are useful for PV performance model validation studies.

14 SOLAR ENERGY↗

An Optimized H5 Hysteresis Current Control with Clamped Diodes in Transformer-Less Grid-PV Inverter

With the rise of renewable energy penetration in the grid, photovoltaic (PV) panels are connected to the grid via inverters to supply solar energy. Transformer-less grid-tied PV inverters are gaining popularity because of their improved efficiency, reduced size, and lower costs. However, they can induce a path for leakage currents between the PV and the grid due to the absence of galvanic isolation. This leads to serious electromagnetic interference, loss in efficiency, and safety concerns. The leakage current is primarily influenced by the nature of the common mode voltage (CMV), which is determined by the switching techniques of the inverter. In this paper, a novel inverter topology of Hysteresis Controlled H5 with Two Clamping Diodes (HCH5-D2) is derived. The HCH5-D2 topology helps decouple the AC part (Grid) and DC part (PV) during the freewheeling period to make the CMV constant, thereby reducing the leakage current. Additionally, the extra diodes help reduce voltage spikes generated during the freewheeling period and maintain the CMV at a constant value. Finally, a 2.2 kW grid-connected single-phase HCH5-D2 PV inverter system’s MATLAB simulation is presented, showing better results compared to a traditional H4 inverter.

42 ENGINEERING↗

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez↗

Impacts of Voltage-Based Grid-Support Functions on Energy Production of PV Customers: Preprint

This paper presents the impact of grid-support utility-interactive inverter functions, such as volt/volt-ampere reactive and volt/watt controls, on quasi-steady-state feeder voltages and on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, Hawai'i. These autonomous inverter controls provide an effective means to modulate active and reactive power based on local voltage measurements and therefore serve as good candidates for non-wire alternatives to increase PV hosting capacity. However, because the activation of these functions can result in PV energy curtailment, this study addresses the concerns about the impact of these advanced inverter controls on curtailment through detailed quasi-static time series (QSTS) simulations. This study proposes four metrics-maximum and average grid-support function curtailments, average increased generation, and average net generation change-to assess the impact of a given control on PV systems located on customer sites. For representative scenarios modeled in detail, it was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 ranges. A reliable relationship between curtailment and peak customer voltage is demonstrated, allowing peak voltage to be used as an indicator of curtailment without the need to measure curtailment directly.

14 SOLAR ENERGY↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

PV Module and System Reliability Research

While photovoltaic (PV) technologies have experienced widespread success and adoption, continued growth of these technologies - especially new PV technologies - requires ongoing improvements to their reliability and the testing procedures, data, and standards that underpin them. To better understand and address failure mechanisms of PV modules and systems, NREL conducts testing, models failures, analyzes performance data, helps to develop standards, and convenes expert stakeholders. This work is focused both on improving the performance of industry-dominant PV technologies and rapidly de-risking new PV technologies so they can be proven reliable without decades of field testing.

14 SOLAR ENERGY↗

PV Validation Hub

The Validation Hub will be a clearinghouse for the transfer of novel algorithms and software from the PV research community to industry. Potential algorithms tested in the Hub could include the estimation of various PV loss factors and the detection of various operational issues. The primary function of the Hub will be for developers to submit executable code which will run on hosted data sets. Developers will receive private reports on the accuracy and performance (e.g., run-time) of the submitted algorithms, and public high level summaries will be hosted. These summaries will indicate the organization who submitted the algorithm (e.g., links to GitHub pages, documentation websites, etc.), high-level accuracy metrics, and standardized performance metrics. These results will be stored in a publicly available database, accessible through the Hub, with the ability for users to sort and filter the results. In short, the Hub will be presented to public users as a collection of interactive leaderboards, organized around specific analysis tasks pertinent to the PV data science community. These tasks include things such as the estimation of various PV loss factors and the detection of various operational issues. We will present progress on the development of this hub, including preliminary results of comparative validation of PV data science algorithms and progress towards building the platform itself.

algorithm↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

PV Reliability and Resilience in Challenging Climates

Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.

degradation↗

PV System Availability from Commercial and Utility-Scale Systems [Slides]

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with worse inverter availability results for larger PV systems. Potential causes of this effect are under investigation.

14 SOLAR ENERGY↗

PV Reference Cells for Outdoor Use: Stability Over Four Years of Deployment

Photovoltaic (PV) reference cells are frequently used to evaluate the performance of PV power plants. They provide a measure of irradiance that strongly correlates with the electrical output of PV modules, which makes them very useful for detecting short-term anomalies or long-term degradation in PV power plant output. One very important quality is long-term stability. This report presents observations about the stability of a set of 22 commercial reference cells that have been in continuous operation for a period of four years at the Solar Radiation Research Laboratory (SRRL) site at the National Renewable Energy Laboratory (NREL). The 22 reference cells at the SRRL represent 10 different models from 6 manufacturers.

14 SOLAR ENERGY↗

PV Lifetime Project - 2025 NLR Annual Report

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light and elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions. Overall annual degradation rates are as follows: our first modules to be deployed (Jinko, Trina, QCells) have annual median degradation rate between -0.4%/yr and -0.5%/yr mainly concentrated in the first year. Mission Solar, LG and Panasonic modules are all displaying modest degradation, better than -0.3% / year. Indeed, Mission Solar fielded modules degraded less than their control modules which remain indoors and un-exposed. This is also true for the LONGi monofacial modules, which had some field degradation, but not as much as the degradation of the indoor control modules. The LONGi bifacial modules on the other hand have degraded more in the field than their monofacial counterparts, although still a modest amount (-0.4 %/yr). Of the four newest module types in the study, only one has had better than average degradation. REC360NP2 (N-type TOPCon) had a slight performance increase over the first year and a half of field deployment. For the other three new module types (plus one older module type), degradation was more rapid. In our study of 16 module types, four have demonstrated degradation faster than -1%/yr: two N-type Heterojunction, one PERC bifacial and one PERC shingled module. The two heterojunction modules in our study are degrading the most rapidly. Sunpreme n-HIT bifacial modules are showing a loss rate around -1.5%/yr, for over -10% total to date. This is largely attributed to loss in front-side Isc. This is distinct from the REC 405AA-Pure modules which have degraded -6.8% in only a year and a half, for an annualized decline of -3.9 %/yr. For this module type, the decline is roughly half in Voc, with the remaining split between FF and Isc. Of the remaining two module types, Prism Solar PERC bifacial has declined -5% total since 2019, although this loss appears to have stabilized in the most recent measurement. The Solaria PowerX-400R Shingled module type has also lost around -3.2% in the first 1.5 years of field deployment. It remains to be seen if these losses will continue with time.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation & Parameterization

Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.

14 SOLAR ENERGY↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter

With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. Furthermore, the simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.

14 SOLAR ENERGY↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Numerical Oscillation Prevention for PV Inverter Controllers in Quasi-Steady-State Simulators

Droop-based PV inverter control methods are popular for preventing overvoltage in low voltage networks with high installations of PV solar. Quasi-steady-state simulators (QSTS) can be used to reduce the computational burden of conducting long-term techno-economic analyses of such PV inverter controllers. If dynamic models for droop-based controllers are directly implemented in QSTS, numerical oscillation occurs and the controllers fail to converge to their steady-state operation. In this paper, a power network sensitivity-based algorithm is proposed for preventing numerical oscillation while implementing active and reactive droop-based PV inverter controllers in quasisteady state simulation tool (e.g. in GridLAB-D). Convergence of the sensitivity-based algorithm is verified using a typical radial distribution feeder. It is found that all three controllers reached converged state in less than 15 iterations.

GridLAB-D, PV inverter control, quasi-steady-state↗

Evaluation of Curtailment Associated with PV System Design Considerations

Distributed photovoltaic (PV) systems equipped with advanced inverters can control real and reactive power output based on grid and atmospheric conditions. The Volt-Var control method allows inverters to regulate local grid voltages by producing or consuming reactive power. Based on their power ratings, the inverters may need to curtail real power to meet the reactive power requirements, which decreases their total energy production. To evaluate the expected curtailment associated with Volt-Var control, yearlong quasi-static time-series (QSTS) simulations were conducted on a realistic distribution feeder under a variety of PV system design considerations. Overall, this paper found that the amount of curtailed energy is low (<; 0.55%) compared to the total PV energy production in a year but is affected by several PV system design considerations.

41 EE - Solar Energy Technologies Office (EE-4S)↗