Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUSH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Pushing the limits of spectroscopy with S 3

A new LINAG accelerator is developed for production of high intensity deuteron beam for the SPIRAL2 project. It will also deliver unprecedented high intensity stable beams that can be used for direct reactions on a target. The Super Separator Spectrometer (S{sup 3}) is designed to open with these beams new horizons for the physics of rare nuclei and low production cross-section nuclei at the extreme limits of the nuclear chart. The S{sup 3} focal-plane detection is one of the major equipments in this framework. A research and development program has been launched in order to get the best setup according to the three main physics cases: Synthesis of new Super Heavy Elements, Spectroscopy of Very and Super Heavy Elements and Spectroscopy of neutron-deficient nuclei around {sup 100}Sn. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pushing the Limits of Thermophotovoltaic Efficiency

We report power conversion efficiency of ~28% from a thermophotovoltaic device, employing the concept of photon regeneration. The regeneration is accomplished using photovoltaic band-edge as the spectral filter. This high efficiency is a direct consequence of enhanced sub-bandgap reflectivity of the device used. Our detail theoretical analysis shows that with further improvement in device geometry and material, it would be possible to achieve near 45% power conversion efficiency.

14 SOLAR ENERGY↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Pushing the limits of electron ptychography

Here, ptychographic imaging in transmission electron microscopy is based on the detection of a huge number of diffraction patterns generated as an electron-beam probe scans the sample. Unlike conventional diffraction experiments where information about the phase of the scattered beam is lost, by scanning the entire sample and recording the diffraction patterns, an inversion analysis can reconstruct the complex amplitude of the beam and ultimately the atomic positions. Probe beams continue to decrease in size and can be much smaller than the distance between scatterers. The diffraction spots also broaden and interfere with one another (see the figure). Analysis of this interference allows more information to be extracted, such as minute details of nuclei position and electronic structure that define physical properties and enable visualization of subtle details of electric fields, orbital orderings, ferroic behavior, and perhaps local spins. Ptychography and related techniques are poised to revolutionize the field of electron microscopy, in much the same way as they have in x-ray crystallography (1), and as aberration correction has achieved for imaging, provided that some key challenges can be met.

47 OTHER INSTRUMENTATION↗

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Pushing back the limit of ab-initio quantum transport simulations on hybrid supercomputers, In: SC '15 Proceedings of the International Conference for High Performance Computing, Networking, Storage and Analysis

The capabilities of CP2K, a density-functional theory package and OMEN, a nano-device simulator, are combined to study transport phenomena from first-principles in unprecedentedly large nanostructures. Based on the Hamiltonian and overlap matrices generated by CP2K for a given system, OMEN solves the Schrödinger equation with open boundary conditions (OBCs) for all possible electron momenta and energies. To accelerate this core operation a robust algorithm called SplitSolve has been developed. It allows to simultaneously treat the OBCs on CPUs and the Schrödinger equation on GPUs, taking advantage of hybrid nodes. Our key achievements on the Cray-XK7 Titan are (i) a reduction in time-to-solution by more than one order of magnitude as compared to standard methods, enabling the simulation of structures with more than 50000 atoms, (ii) a parallel efficiency of 97% when scaling from 756 up to 18564 nodes, and (iii) a sustained performance of 15 DP-PFlop/s.

Computer Science↗

Giallar: push-button verification for the qiskit Quantum compiler

This paper presents Giallar, a fully-automated verification toolkit for quantum compilers. Giallar requires no manual specifications, invariants, or proofs, and can automatically verify that a compiler pass preserves the semantics of quantum circuits. To deal with unbounded loops in quantum compilers, Giallar abstracts three loop templates, whose loop invariants can be automatically inferred. To efficiently check the equivalence of arbitrary input and output circuits that have complicated matrix semantics representation, Giallar introduces a symbolic representation for quantum circuits and a set of rewrite rules for showing the equivalence of symbolic quantum circuits. With Giallar, we implemented and verified 44 (out of 56) compiler passes in 13 versions of the Qiskit compiler, the open-source quantum compiler standard, during which three bugs were detected in and confirmed by Qiskit. Furthermore, our evaluation shows that most of Qiskit compiler passes can be automatically verified in seconds and verification imposes only a modest overhead to compilation performance.

automated verification↗

epics-alarm-push

Prototype IOC alarm pusher using Redis in a support module.

Bracey, Dave [Fermi National Accelerator Laborator↗

CO2 Push-Pull Single Fault Injection Simulations

ASCII text files containing grid-block name, X-Y-Z location, and multiple parameters from TOUGH2 simulation output of CO2 injection into an idealized single fault representing a dipping normal fault at the Desert Peak geothermal field (readable by GMS). The fault is composed of a damage zone, a fault gouge and a slip plane. The runs are described in detail in the following: Borgia A., Oldenburg C.M., Zhang R., Jung Y., Lee K.J., Doughty C., Daley T.M., Chugunov N., Altundas B, Ramakrishnan T.S., 2017. Carbon Dioxide Injection for Enhanced Characterization of Faults and Fractures in Geothermal Systems. Proceedings of the 42st Workshop on Geothermal Reservoir Engineering, Stanford University, Stanford, California, February 13-17.

15 GEOTHERMAL ENERGY↗

Pushing the limits of NAND technology scaling with ferroelectrics

Artificial intelligence (AI) continues to drive transformative advancements across various industries. The data-intensive nature of AI training (and inferencing) has resulted in the generation of unprecedented volumes of data with machine-generated content surpassing human-generated data by more than 100-fold in 2025. Efficiently managing this data influx necessitates advanced digital storage technologies. However, traditional NAND flash memory, which is critical for supporting data flows in AI systems—alongside high-bandwidth memory, for AI training—faces fundamental scaling limitations as it approaches the 1000-layer milestone, encompassing more than 40 trillion transistors. This article delves into the potential of hafnia-based ferroelectric materials as a breakthrough solution to these challenges. Recent advancements indicate that the intrinsic limitations of ferroelectric field-effect transistors (FEFETs) can be mitigated through material and device-level engineering. These advancements enable FEFETs to meet the stringent density, reliability, and scalability requirements of future three-dimensional NAND technology. The role of ferroelectrics in addressing NAND scaling challenges and expanding storage capabilities presents a promising avenue for meeting the storage demands of the AI-driven era.

3D NAND↗

Understanding and Pushing the Limits of Nitrogen Doping

This work will describe Fermilab experiments that focus on the optimization of doping parameters to achieve low sensitivity to trapped magnetic flux while maintaining very high Q characteristic of nitrogen doped cavities and same or higher quench fields. Working partially in the context of LCLS-2 higher energy upgrade, new doping recipes are pursued and have been found to vary the mean free path of the resonator which is related to the sensitivity to trapped magnetic flux. Moreover, a correlation has been found between lighter doping and higher quench fields while maintaining sufficiently low surface resistance.

43 PARTICLE ACCELERATORS↗