Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Normal pressure tests on unstiffened flat plates

Flat sheet panels of aluminum alloy (all 17S-T except for two specimens of 24S-T) were tested under normal pressures with clamped edge supports in the structures laboratory of the Guggenheim Aeronautical Laboratory, California Institute of Technology. The thicknesses used ranged from 0.010 to 0.080 inch; the panel sizes ranged from 10 by 10 inches to 10 by 40 inches; and the pressure range was from 0 to 60-pounds-per-square-inch gage. Deflection patterns were measured and maximum tensile strains in the center of the panel were determined by electric strain gages. The experimental data are presented by pressure-strain, pressure-maximum-deflection, and pressure-deflection curves. The results of these tests have been compared with the corresponding strains and deflections as calculated by the simple membrane theory and by large deflection theories.

Head, Richard M↗

Error Analysis of the Shuttle Orbital Maneuvering System P-V-T Propellant Gaging Module. Mission Planning, Mission Analysis and Software Formulation

An investigation of the shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors, propellant loading uncertainties, and simplifying assumptions in the software are non-linear over the range of the usable propellant quantity gage (0-100%), with the largest error being at the zero point. When the OMS propellant tanks in the orbiter vehicle pods are filled to contain 100% of the maximum usable propellant, the gaging error at the zero point was determined to be 9.5% for the fuel and 9.5% for the oxidizer. When the OMS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error is still 9.5% for the fuel and 9.5% for the oxidizer.

Duhon, D. D.↗

Apollo 15 mission report. Supplement 2: Service propulsion system final flight evaluation

The command and service module 112 service propulsion system performance for the Apollo 15 mission was evaluated and found to be satisfactory. The following items were considered: (1) the steady-state performance as determined from analysis of the third and eight burns; (2) techniques, problems, and assumptions; (3) flight analysis results as compared to the preflight predicted performance; (4) the propellant utilization and gaging system operation; (5) the pressurization system performance; (6) transient data; and (7) revision of estimated propellant consumption.

Smith, R. J.↗

Gas-Density Gage

Lightweight density gage that operates over broad pressure range accurately measures gas pressures.

Bernsterin, W.↗

Use of hot-wire anemometry for turbulence measurements in shock induced flows

A research program is currently being conducted with the aim to investigate the operating environment of future gas turbines. The present paper provides a description of the experimental methods which have been employed in performing turbulence intensity measurements in shock-induced flows. In a discussion of the instrumentation, attention is given to the employed low pressure shock tube, the hot-wire probe, the anemometer, the test facility, the experimental setup, the Kistler pressure transducer, and silicon piezoresistive gages. Aspects of instrumentation calibration are considered along with data corrections, experimental data, and data processing.

Hartung, L. C.↗

Experimental short-duration techniques

Short-duration facilities used for gas turbine studies are described. Data recording techniques; and instruments (thin-film heat flux gages, high-frequency response pressure measurements, total temperature probes, measurement of rotor tip speed, active measurement of tip clearance) are presented.

Dunn, Michael G.↗

Thermal Vacuum Testing of ICPTA RCS at Plum Brook B-2

Vacuum and thermal vacuum testing of the Integrated Cryogenic Propulsion Test Article (ICPTA) was performed at the Plum Brook B-2 facility as a part of a system checkout and facility characterization effort. Multiple test objectives included: integrated Reaction Control System (RCS) characterization, cold helium pressurization system characterization, modal propellant gaging experiment (Orion), CFM propellant loading experiments, main engine characterization. The ICPTA is a test bed for LOX/LCH4 technologies built in 2016 using new components and hardware from the former Morpheus vehicle and other projects.

Atwell, M. J.↗

Phase and time-resolved measurements of unsteady heat transfer and pressure in a full-stage rotating turbine

This paper presents detailed phase-resolved heat-flux data obtained on rotor blades and a comparison of simultaneously obtained time-resolved heat-flux and static pressure data obtained on the stationary shroud of a Garrett TFE 731-2 HP full-stage rotating turbine. A shock tube is used to generate a short-duration source of heated and pressurized air and platinum thin-film gages are used to obtain heat-flux measurements. Blade results are presented at several selected blade locations. Shroud surface pressure and heat-flux time histories are presented for comparable locations relative to the blade position.

Dunn, M. G.↗

Vacuum Characterization and Improvement for the Jefferson Lab Polarized Electron Source

Operating the JLab polarized electron source with high reliability and long lifetime requires vacuum near the XHV level, defined as pressure below 7.5×10 -13 Torr. This paper describes ongoing vacuum research at Jefferson Lab including characterization of outgassing rates for surface coatings and heat treatments, ultimate pressure measurements, investigation of pumping including an XHV cryopump, and characterization of ionization gauges in this pressure regime.

43 PARTICLE ACCELERATORS↗

Incident shock-wave characteristics in air, argon, carbon dioxide, and helium in a shock tube with unheated helium driver

Incident shock-wave velocities were measured in the Langley 6-inch expansion tube, operated as a shock tube, with air, argon, carbon dioxide, and helium as test gases. Unheated helium was used as the driver gas and most data were obtained at pressures of approximately 34 and 54 MN/sq m. A range of pressure ratio across the diaphragm was obtained by varying the quiescent test-gas pressure, for a given driver pressure, from 0.0276 to 34.5 kN/sq m. Single- and double-diaphragm modes of operation were employed and diaphragms of various materials tested. Shock velocity was determined from microwave interferometer measurements, response of pressure transducers positioned along interferometer measurements, response of pressure transducers positioned along the driven section (time-of-arrival gages), and to a lesser extent, measured tube-wall pressure. Velocities obtained from these methods are compared and limitations of the methods discussed. The present results are compared with theory and the effects of diaphragm mode (single or double diaphragm), diaphragm material, heating of the driver gas upon pressurization of the driver section, diaphragm opening time, interface mixing, and two-dimensional (nonplanar) flow are discussed.

Miller, C. G., III↗

Unsteady pressure loads in a generic high speed engine model

Unsteady pressure loads were measured along the top interior wall of a generic high-speed engine (GHSE) model undergoing performance tests in the combustion-Heated Scramjet Test Facility at the Langley Research Center. Flow to the model inlet was simulated at 72000 ft and a flight Mach number of 4. The inlet Mach number was 3.5 with a total temperature and pressure of 1640 R and 92 psia. The unsteady pressure loads were measured with 5 piezoresistive gages, recessed into the wall 4 to 12 gage diameters to reduce incident heat flux to the diaphragms, and distributed from the inlet to the combustor. Contributors to the unsteady pressure loads included boundary layer turbulence, combustion noise, and transients generated by unstart loads. Typical turbulent boundary layer rms pressures in the inlet ranged from 133 dB in the inlet to 181 dB in the combustor over the frequency range from 0 to 5 kHz. Downstream of the inlet exist, combustion noise was shown to dominate boundary layer turbulence noise at increased heat release rates. Noise levels in the isolator section increased by 15 dB when the fuel-air ratio was increased from 0.37 to 0.57 of the stoichiometric ratio. Transient pressure disturbances associated with engine unstarts were measured in the inlet and have an upstream propagation speed of about 7 ft/sec and pressure jumps of at least 3 psia.

Parrott, Tony L.↗

Two-directional skin friction measurement utilizing a compact internally mounted thin-liquid-film skin friction meter

A new, compact oil film skin friction meter capable of measuring skin friction in two directions has been designed and constructed. The instrument allows the thin liquid film technique to now be applied in flight and in a wider variety of laboratory conditions. The instrument was tested by comparing measurements with those given by a floating element gage in laminar, transitional, and turbulent boundary layers with zero pressure gradient. Both instruments agreed satisfactorily with each other and with the expected curves for the laminar and turbulent boundary layers. Significant differences were at first seen between the oil film meter and two floating element gages in the case of a favorable pressure gradient, but when a correction is applied to account for the normal force acting on the pendulum-type gage, the three instruents are much closer. The directional sensitivity of the oil film gage is also demonstrated.

Seto, Jeffrey A.↗

Calibration and Data Analysis of the MC-130 Air Balance

Design, calibration, calibration analysis, and intended use of the MC-130 air balance are discussed. The MC-130 balance is an 8.0 inch diameter force balance that has two separate internal air flow systems and one external bellows system. The manual calibration of the balance consisted of a total of 1854 data points with both unpressurized and pressurized air flowing through the balance. A subset of 1160 data points was chosen for the calibration data analysis. The regression analysis of the subset was performed using two fundamentally different analysis approaches. First, the data analysis was performed using a recently developed extension of the Iterative Method. This approach fits gage outputs as a function of both applied balance loads and bellows pressures while still allowing the application of the iteration scheme that is used with the Iterative Method. Then, for comparison, the axial force was also analyzed using the Non-Iterative Method. This alternate approach directly fits loads as a function of measured gage outputs and bellows pressures and does not require a load iteration. The regression models used by both the extended Iterative and Non-Iterative Method were constructed such that they met a set of widely accepted statistical quality requirements. These requirements lead to reliable regression models and prevent overfitting of data because they ensure that no hidden near-linear dependencies between regression model terms exist and that only statistically significant terms are included. Finally, a comparison of the axial force residuals was performed. Overall, axial force estimates obtained from both methods show excellent agreement as the differences of the standard deviation of the axial force residuals are on the order of 0.001 % of the axial force capacity.

Booth, Dennis↗

Hydroelastic slamming response in the evolution of a flip-through event during shallow-liquid sloshing

The evolution of a flip-through event [6] upon a vertical, deformable wall during shallow-water sloshing in a 2D tank is analyzed, with specific focus on the role of hydroelasticity. An aluminium plate, whose dimensions are Froude-scaled in order to reproduce the first wet natural frequency associated with the typical structural panel of a Mark III containment system, is used. (Mark III Containment System is a membrane-type tank used in the Liquefied Natural Gas (LNG) carrier to contain the LNG. A typical structural panel is composed by two metallic membranes and two independent thermal insulation layers. The first membrane contains the LNG, the second one ensures redundancy in case of leakage.) Such a system is clamped to a fully rigid vertical wall of the tank at the vertical ends while being kept free on its lateral sides. Hence, in a 2D flow approximation the system can be suitably modelled, as a double-clamped Euler beam, with the Euler beam theory. The hydroelastic effects are assessed by cross-analyzing the experimental data based both on the images recorded by a fast camera, and on the strain measurements along the deformable panel and on the pressure measurements on the rigid wall below the elastic plate. The same experiments are also carried out by substituting the deformable plate with a fully stiff panel. The pressure transducers are mounted at the same positions of the strain gauges used for the deformable plate. The comparison between the results of rigid and elastic case allows to better define the role of hydroelasticity. The analysis has identified three different regimes characterizing the hydroelastic evolution: a quasi-static deformation of the beam (regime I) precedes a strongly hydroelastic behavior (regime II), for which the added mass effects are relevant; finally, the free-vibration phase (regime III) occurs. A hybrid method, combining numerical modelling and experimental data from the tests with fully rigid plate is proposed to examine the hydroelastic effects. Within this approach, the measurements provide the experimental loads acting on the rigid plate, while the numerical solution enables a more detailed analysis, by giving additional information not available from the experimental tests. More in detail, an Euler beam equation is used to model numerically the plate with the added-mass contribution estimated in time. In this way the resulting hybrid method accounts for the variation of the added mass associated with the instantaneous wetted length of the beam, estimated from the experimental images. Moreover, the forcing hydrodynamic load is prescribed by using the experimental pressure distribution measured in the rigid case. The experimental data for the elastic beam are compared with the numerical results of the hybrid model and with those of the standard methods used at the design stage. The comparison against the experimental data shows an overall satisfactory prediction of the hybrid model. The maximum peak pressure predicted by the standard methods agrees with the result of the hybrid model only when the added mass effect is considered. However, the standard methods are not able to properly estimate the temporal evolution of the plate deformation.

42 ENGINEERING↗

Precision gage measures ultrahigh vacuum levels

Ionization gage in which internally generated X rays are minimized is described. This gage permits the measurement of gas pressures in ultrahigh systems of micro-pico torr /10-18/.

Hudson, J. B.↗