Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DEMAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multi-functional anodes boost the transient power and durability of proton exchange membrane fuel cells

Abstract Proton exchange membrane fuel cells have been regarded as the most promising candidate for fuel cell vehicles and tools. Their broader adaption, however, has been impeded by cost and lifetime. By integrating a thin layer of tungsten oxide within the anode, which serves as a rapid-response hydrogen reservoir, oxygen scavenger, sensor for power demand, and regulator for hydrogen-disassociation reaction, we herein report proton exchange membrane fuel cells with significantly enhanced power performance for transient operation and low humidified conditions, as well as improved durability against adverse operating conditions. Meanwhile, the enhanced power performance minimizes the use of auxiliary energy-storage systems and reduces costs. Scale fabrication of such devices can be readily achieved based on the current fabrication techniques with negligible extra expense. This work provides proton exchange membrane fuel cells with enhanced power performance, improved durability, prolonged lifetime, and reduced cost for automotive and other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Exploring the Frontiers of Energy Efficiency using Power Management at System Scale

In the face of surging power demands for exascale HPC systems, this work tackles the critical challenge of understanding the impact of software-driven power management techniques like Dynamic Voltage and Frequency Scaling (DVFS) and Power Capping. These techniques have been actively developed over the past few decades. By combining insights from GPU benchmarking to understand application power profiles, we present a telemetry data-driven approach for deriving energy savings projections. This approach has been demonstrably applied to the Frontier supercomputer at scale. Our findings based on three months of telemetry data indicate that, for certain resource-constrained jobs, significant energy savings (up to 8.5%) can be achieved without compromising performance. This translates to a substantial cost reduction, equivalent to 1438 MWh of energy saved. The key contribution of this work lies in the methodology for establishing an upper limit for these best-case scenarios and its successful application. This work enables HPC professionals to optimize the power-performance trade-off within constrained power budgets, not only for the exascale era but also beyond.

Karimi, Ahmad Maroof↗

Solar potential inventory and modeling

Image processing procedures for calculating the energy that roof-mounted solar collectors can potentially supply in a metropolitan area are presented. Satellite multispectral imagery from which land cover types can be determined digitally was sampled in order to estimate the percentage of land area occupied by flat or south-facing roof tops in residential and commercial/industrial areas. Procedures were applied to the various power subdistricts of the western San Fernando valley of California, and it was found that on the average 120% of the existing power demand could be met if only half the useable rooftop area were utilized, amounting to 385 MW of peak power and indicating the applicability of solar cells to power generation in urban areas.

Angelici, G. L.↗

Space and Terrestrial Power System Integration Optimization Code BRMAPS for Gas Turbine Space Power Plants With Nuclear Reactor Heat Sources

In view of the difficult times the US and global economies are experiencing today, funds for the development of advanced fission reactors nuclear power systems for space propulsion and planetary surface applications are currently not available. However, according to the Energy Policy Act of 2005 the U.S. needs to invest in developing fission reactor technology for ground based terrestrial power plants. Such plants would make a significant contribution toward drastic reduction of worldwide greenhouse gas emissions and associated global warming. To accomplish this goal the Next Generation Nuclear Plant Project (NGNP) has been established by DOE under the Generation IV Nuclear Systems Initiative. Idaho National Laboratory (INL) was designated as the lead in the development of VHTR (Very High Temperature Reactor) and HTGR (High Temperature Gas Reactor) technology to be integrated with MMW (multi-megawatt) helium gas turbine driven electric power AC generators. However, the advantages of transmitting power in high voltage DC form over large distances are also explored in the seminar lecture series. As an attractive alternate heat source the Liquid Fluoride Reactor (LFR), pioneered at ORNL (Oak Ridge National Laboratory) in the mid 1960's, would offer much higher energy yields than current nuclear plants by using an inherently safe energy conversion scheme based on the Thorium --> U233 fuel cycle and a fission process with a negative temperature coefficient of reactivity. The power plants are to be sized to meet electric power demand during peak periods and also for providing thermal energy for hydrogen (H2) production during "off peak" periods. This approach will both supply electric power by using environmentally clean nuclear heat which does not generate green house gases, and also provide a clean fuel H2 for the future, when, due to increased global demand and the decline in discovering new deposits, our supply of liquid fossil fuels will have been used up. This is expected within the next 30 to 50 years, as predicted by the Hubbert model and confirmed by other global energy consumption prognoses. Having invested national resources into the development of NGNP, the technology and experience accumulated during the project needs to be documented clearly and in sufficient detail for young engineers coming on-board at both DOE and NASA to acquire it. Hands on training on reactor operation, test rigs of turbomachinery, and heat exchanger components, as well as computational tools will be needed. Senior scientist/engineers involved with the development of NGNP should also be encouraged to participate as lecturers, instructors, or adjunct professors at local universities having engineering (mechanical, electrical, nuclear/chemical, and/or materials) as one of their fields of study.

Juhasz, Albert J.↗

Generalized Aggregation and Coordination of Residential Loads in a Smart Community

Flexibility from residential loads presents an enormous potential to provide various services to the smart grid. In this paper, we propose a unified hierarchical framework for aggregation and coordination of various residential loads in a smart community, such as Thermostatically Controlled Loads (TCLs), Distributed Energy Storages (DESs), residential Pool Pumps (PPs), and Electric Vehicles (EVs). A central idea of this framework is a virtual battery model, which provides a simple and intuitive tool to aggregate the flexibility of distributed loads. Moreover, a multi-stage Nash-bargainingbased coordination strategy is proposed to coordinate different aggregations of residential loads for demand response. Case studies are provided to demonstrate the efficacy of our proposed framework and coordination strategy in managing peak power demand in a smart residential community.

Hao, He↗

Multi-period Nash bargaining for Coordination of Distributed Energy Resources

Flexibility from distributed energy resources presents an enormous potential to provide various services to the smart grid. In this paper, we propose a unified hierarchical framework for aggregation and coordination of various flexible loads, such as commercial building Heating, Ventilation, and Air-Conditioning (HVAC) systems, Thermostatically Controlled Loads (TCLs), Distributed Energy Storages (DESs), residential Pool Pumps (PPs), and Electric Vehicles (EVs). Moreover, a multistage Nash-bargaining-based control strategy is proposed to coordinate different aggregations of flexible loads for demand response. Case studies are provided to demonstrate the efficacy of our proposed framework and coordination strategy in managing peak power demand in a community.

Hao, He↗

Technoeconomic Modeling of Battery Energy Storage in SAM

Detailed comprehensive lead-acid and lithium-ion battery models have been integrated with photovoltaic models in an effort to allow System Advisor Model (SAM) to offer the ability to predict the performance and economic benefit of behind the meter storage. In a system with storage, excess PV energy can be saved until later in the day when PV production has fallen, or until times of peak demand when it is more valuable. Complex dispatch strategies can be developed to leverage storage to reduce energy consumption or power demand based on the utility rate structure. This document describes the details of the battery performance and economic models in SAM.

14 SOLAR ENERGY↗

High Temperature Polymers for use in Fuel Cells

NASA Glenn Research Center (GRC) is currently working on polymers for fuel cell and lithium battery applications. The desire for more efficient, higher power density, and a lower environmental impact power sources has led to interest in proton exchanges membrane fuels cells (PEMFC) and lithium batteries. A PEMFC has many advantages as a power source. The fuel cell uses oxygen and hydrogen as reactants. The resulting products are electricity, heat, and water. The PEMFC consists of electrodes with a catalyst, and an electrolyte. The electrolyte is an ion-conducting polymer that transports protons from the anode to the cathode. Typically, a PEMFC is operated at a temperature of about 80 C. There is intense interest in developing a fuel cell membrane that can operate at higher temperatures in the range of 80 C- 120 C. Operating the he1 cell at higher temperatures increases the kinetics of the fuel cell reaction as well as decreasing the susceptibility of the catalyst to be poisoned by impurities. Currently, Nafion made by Dupont is the most widely used polymer membrane in PEMFC. Nafion does not function well above 80 C due to a significant decrease in the conductivity of the membrane from a loss of hydration. In addition to the loss of conductivity at high temperatures, the long term stability and relatively high cost of Nafion have stimulated many researches to find a substitute for Nafion. Lithium ion batteries are popular for use in portable electronic devices, such as laptop computers and mobile phones. The high power density of lithium batteries makes them ideal for the high power demand of today s advanced electronics. NASA is developing a solid polymer electrolyte that can be used for lithium batteries. Solid polymer electrolytes have many advantages over the current gel or liquid based systems that are used currently. Among these advantages are the potential for increased power density and design flexibility. Automobiles, computers, and cell phones require highly efficient power density for lowering emissions and meeting increasing consumer demands. Many of the solutions can be provided by proton exchange membrane fuel cells and lithium batteries. NASA Glenn Research Center has recognized this need, and is presently engaged in a solution. The goals for the summer include mastering synthesis techniques, understanding the reactions occurring during the synthesis, and characterizing the resulting polymer membranes using NMR, DSC, and TGA for the PEMFC and lithium batteries.

Peplowski, Katherine M.↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Structural evaluation of concepts for a solar energy concentrator for Space Station advanced development program

Solar dynamic power systems have a higher thermodynamic efficiency than conventional photovoltaic systems; therefore they are attractive for long-term space missions with high electrical power demands. In an investigation conducted in support of a preliminary concept for Space Station Freedom, an approach for a solar dynamic power system was developed and a number of the components for the solar concentrator were fabricated for experimental evaluation. The concentrator consists of hexagonal panels comprised of triangular reflective facets which are supported by a truss. Structural analyses of the solar concentrator and the support truss were conducted using finite-element models. A number of potential component failure scenarios were postulated and the resulting structural performance was assessed. The solar concentrator and support truss were found to be adequate to meet a 1.0-Hz structural dynamics design requirement in pristine condition. However, for some of the simulated component failure conditions, the fundamental frequency dropped below the 1.0-Hz design requirement. As a result, two alternative concepts were developed and assessed. One concept incorporated a tetrahedral ring truss support for the hexagonal panels: the second incorporated a full tetrahedral truss support for the panels. The results indicate that significant improvements in stiffness can be obtained by attaching the panels to a tetrahedral truss, and that this concentrator and support truss will meet the 1.0-Hz design requirement with any of the simulated failure conditions.

Kenner, Winfred S.↗

Battery Reinitialization of the Photovoltaic Module of the International Space Station

The photovoltaic (PV) module on the International Space Station (ISS) has been operating since November 2000 and supporting electric power demands of the ISS and its crew of three. The PV module contains photovoltaic arrays that convert solar energy to electrical power and an integrated equipment assembly (IEA) that houses electrical hardware and batteries for electric power regulation and storage. Each PV module contains two independent power channels for fault tolerance. Each power channel contains three batteries in parallel to meet its performance requirements and for fault tolerance. Each battery consists of 76 Ni-Hydrogen (Ni-H2) cells in series. These 76 cells are contained in two orbital replaceable units (ORU) that are connected in series. On-orbit data are monitored and trended to ensure that all hardware is operating normally. Review of on-orbit data showed that while five batteries are operating very well, one is showing signs of mismatched ORUs. The cell pressure in the two ORUs differs by an amount that exceeds the recommended range. The reason for this abnormal behavior may be that the two ORUs have different use history. An assessment was performed and it was determined that capacity of this battery would be limited by the lower pressure ORU. Steps are being taken to reduce this pressure differential before battery capacity drops to the point of affecting its ability to meet performance requirements. As a first step, a battery reinitialization procedure was developed to reduce this pressure differential. The procedure was successfully carried out on-orbit and the pressure differential was reduced to the recommended range. This paper describes the battery performance and the consequences of mismatched ORUs that make a battery. The paper also describes the reinitialization procedure, how it was performed on orbit, and battery performance after the reinitialization. On-orbit data monitoring and trending is an ongoing activity and it will continue as ISS assembly progresses.

Hajela, Gyan↗

Small Microprocessor for ASIC or FPGA Implementation

A small microprocessor, suitable for use in applications in which high reliability is required, was designed to be implemented in either an application-specific integrated circuit (ASIC) or a field-programmable gate array (FPGA). The design is based on commercial microprocessor architecture, making it possible to use available software development tools and thereby to implement the microprocessor at relatively low cost. The design features enhancements, including trapping during execution of illegal instructions. The internal structure of the design yields relatively high performance, with a significant decrease, relative to other microprocessors that perform the same functions, in the number of microcycles needed to execute macroinstructions. The problem meant to be solved in designing this microprocessor was to provide a modest level of computational capability in a general-purpose processor while adding as little as possible to the power demand, size, and weight of a system into which the microprocessor would be incorporated. As designed, this microprocessor consumes very little power and occupies only a small portion of a typical modern ASIC or FPGA. The microprocessor operates at a rate of about 4 million instructions per second with clock frequency of 20 MHz.

Kleyner, Igor↗

Use of a Geothermal-Solar Hybrid Power Plant to Mitigate Declines in Geothermal Resource Productivity

Many, if not all, geothermal resources are subject to decreasing productivity manifested in the form of decreasing brine temperature, flow rate, or both during the life span of the associated power generation project. The impacts of resource productivity decline on power plant performance can be significant; a reduction in heat input to a power plant not only decreases the thermal energy available for conversion to electrical power, but also adversely impacts the power plant conversion efficiency. The reduction in power generation is directly correlated to a reduction in revenues from power sales. Further, projects with Power Purchase Agreement (PPA) contracts in place may be subject to significant economic penalties if power generation falls below the default level specified. A potential solution to restoring the performance of a power plant operating from a declining productivity geothermal resource involves the use of solar thermal energy to restore the thermal input to the geothermal power plant. There are numerous technical merits associated with a renewable geothermal-solar hybrid plant in which the two heat sources share a common power block. The geo-solar hybrid plant could provide a better match to typical electrical power demand profiles than a stand-alone geothermal plant. The hybrid plant could also eliminate the stand-alone concentrated solar power plant thermal storage requirement for operation during times of low or no solar insolation. This paper identifies hybrid plant configurations and economic conditions for which solar thermal retrofit of a geothermal power plant could improve project economics. The net present value of the concentrated solar thermal retrofit of an air-cooled binary geothermal plant is presented as functions of both solar collector array cost and electricity sales price.

14 SOLAR ENERGY↗

Structured Neural Network Modeling for Developing Digital Twins Models of Hydropower Generation Units

Dynamic modeling is a key part in the development of digital twin (DT) for dynamic systems. This is true for hydropower systems, where whole system modeling including penstock, turbine and generators, etc is important in realizing actuate modeling for the real systems. On the other hand, in response to the large variations of the power demand due to increased penetration of renewables such as wind and solar, hydropower systems are now required to operate in a large power generation range. This situation triggers the nonlinear characteristics of the generation unit with respect to its models. As such, it is imperative to use data driven modeling such as neural networks to learn the nonlinear dynamics of the hydropower generation unit. To achieve this objective, this study constructs a modeling and learning algorithm integrated with multiple structured neural network models for the modeling of turbine shaft speed, penstock pressure, and generator power output based on the generator power control setpoint, field current, and field voltage. In addition, the study uses the hydropower data from Tacoma Public Utilities to train and validate the proposed neural network algorithm. The results have shown that this structured neural network modeling approach can learn the system dynamics effectively by using the real-time data collected from the hydropower system with the desired modeling results.

Wang, Hong↗

The US space station and its electric power system

The United States has embarked on a major development program to have a space station operating in low earth orbit by the mid-1990s. This endeavor draws on the talents of NASA and most of the aerospace firms in the U.S. Plans are being pursued to include the participation of Canada, Japan, and the European Space Agency in the space station. From the start of the program these was a focus on the utilization of the space station for science, technology, and commercial endeavors. These requirements were utilized in the design of the station and manifest themselves in: pressurized volume; crew time; power availability and level of power; external payload accommodations; microgravity levels; servicing facilities; and the ability to grow and evolve the space station to meet future needs. President Reagan directed NASA to develop a permanently manned space station in his 1984 State of the Union message. Since then the definition phase was completed and the development phase initiated. A major subsystem of the space station is its 75 kW electric power system. The electric power system has characteristics similar to those of terrestrial power systems. Routine maintenance and replacement of failed equipment must be accomplished safely and easily and in a minimum time while providing reliable power to users. Because of the very high value placed on crew time it is essential that the power system operate in an autonomous mode to minimize crew time required. The power system design must also easily accommodate growth as the power demands by users are expected to grow. An overview of the U.S. space station is provided with special emphasis on its electrical power system.

Thomas, Ronald L.↗

Distinct Dynamics of Lithium Intercalation and Plating on Graphite Anode for Li‐Ion Batteries in eVTOL Applications

In the absence of viable high-energy-density battery alternatives, lithium-ion (Li-ion) batteries remain essential for enabling electric vertical take-off and landing (eVTOL) platforms in advanced air mobility. Unlike Li-ion batteries used in electric vehicles and portable electronics, eVTOL battery systems operate under distinct high-power demands, which necessitate an independent assessment of material degradation mechanisms. This study presents a case analysis of graphite anode evolution under high-power cycling conditions. The findings reveal lithium entrapment within graphite particles, potentially resulting from incomplete Li-ion de-intercalation during a high-rate discharge event that is characteristic of eVTOL take-off and landing. This phenomenon leads to a progressive reduction in graphite-specific capacity and, over time, promotes lithium metal plating on the anode. Notably, the Li-metal plating observed in this study differs from that associated with fast-charging conditions, as it is primarily governed by concentration polarization-induced overpotential in the latter case. In conclusion, these findings highlight the inherent challenges of utilizing graphite in high-power Li-ion battery applications and elucidate the unique degradation mechanisms that arise due to the sluggish reaction kinetics of Li-ion intercalation and de-intercalation within graphite.

Li plating↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗