Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PNEUMATICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

Jones, Kelley, M.↗

Experimental Validation of Model-Based Prognostics for Pneumatic Valves

Because valves control many critical operations, they are prime candidates for deployment of prognostic algorithms. But, similar to the situation with most other components, examples of failures experienced in the field are hard to come by. This lack of data impacts the ability to test and validate prognostic algorithms. A solution sometimes employed to overcome this shortcoming is to perform run-to-failure experiments in a lab. However, the mean time to failure of valves is typically very high (possibly lasting decades), preventing evaluation within a reasonable time frame. Therefore, a mechanism to observe development of fault signatures considerably faster is sought. Described here is a testbed that addresses these issues by allowing the physical injection of leakage faults (which are the most common fault mode) into pneumatic valves. What makes this testbed stand out is the ability to modulate the magnitude of the fault almost arbitrarily fast. With that, the performance of end-of-life estimation algorithms can be tested. Further, the testbed is mobile and can be connected to valves in the field. This mobility helps to bring the overall process of prognostic algorithm development for this valve a step closer to validation. The paper illustrates the development of a model-based prognostic approach that uses data from the testbed for partial validation.

Chetan S Kulkarni↗

Validation of Model-Based Prognostics for Pneumatic Valves in a Cryogenic Fueling Demonstration Testbed

Because valves control many critical operations, they are prime candidates for deployment of prognostic algorithms. But, similar to the situation with most other components, examples of failures experienced in the field are hard to come by. This lack of data impacts the ability to test and validate prognostic algorithms. A solution sometimes employed to overcome this shortcoming is to perform run to failure experiments in a lab. However, the mean time to failure of valves is typically very high (possibly lasting decades), preventing evaluation within a reasonable time frame. Therefore, a mechanism to observe development of fault signatures considerably faster is sought. Described here is a testbed that addresses these issues by allowing the physical injection of leakage faults (which are the most common fault mode) into pneumatic valves. What makes this testbed stand out is the ability to modulate the magnitude of the fault almost arbitrarily fast. With that, the performance of end-of-life estimation algorithms can be tested. Further, the testbed is mobile and can be connected to valves in the field. This mobility helps to bring the overall process of prognostic algorithm development for this valve a step closer to validation. The paper illustrates the development of a model-based prognostic approach that uses data from the testbed for partial validation.

Kulkarni, Chetan S.↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (Figure 1). The spacecraft will perform close-up remote sensing and observations of both moons and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned samples of Phobos regolith [1-2]. To fulfill the mission goals, MMX employs a double sampling approach: Coring and Pneumatic Samplers (Figure 2).The Coring Sampler (C-Sampler), a core soil tube deployed by a robotic arm, providing access to the building blocks of Phobos beneath the surface (>2 cm), and also collect a mixture of near surface material. The P-Sampler, on the other hand, would selectively sample the surface veneer and provides reference of surface component with the C-Sampler. The double sampling system not only enhances the scientific merits of MMX but also reduces risks associated with the sampling of Phobos. Without enough knowledge of the physical and chemical properties, and the geotechnical conditions of the surface of Phobos (e.g., compositions, temperature gradient/variation, porosity, grain size distribution), having two sampling systems that utilize entirely different sampling approaches is prudent.

Dylan Van Dyne↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

A Pneumatic Sampler (P-SMP)is being provided by Honeybee Robotics with support from NASA Planetary Missions Program Office (PMPO)for JAXA’s Martian Moons eXploration (MMX) mission. The goal of this mission is to closely survey the Martian moons Deimos and Phobos, and then to collect regolith from Phobos and return it to Earth. The P-SMP will be mounted to a leg of the lander and will be responsible for collecting surface regolith alongside the JAXA provide Core Sampler (C-SMP). The Sampling Funnel of the P-SMP utilizes two sets of sampling nozzles: one set of nozzles pointed directly at the surface to kick-up and loft material into the sampling head, and a second set of nozzles to direct the oncoming material into the sample return canister further up the lander leg. A robotic arm mounted underneath the lander will then remove the sample canister and place it inside the sample return capsule for Earth return. Several iterations of the P-Sampler have been designed and tested inside a vacuum chamber with Phobos regolith simulant. In all tests, the P-Sampler successfully acquired the sample, even in an extreme scenario where the sampling head was mounted 10 cm above a surface covered with gravel.

Dylan Van Dyne↗

The Dual-Rasp Sampling System Design with Closed Pneumatic Sample Transfer

The novel Dual-Rasp sampling system has been developed for landed missions to low gravity planetary bodies and is particularly well suited for the unique environment of Saturn’s moon Enceladus. The Dual-Rasp sampling system has two counter-rotating rasp cutters that remove material from the surface and direct it into a guide. The cuttings follow the guide into a sample collection cup. When the sampling collection completes, the tool reconfigures by rotating the guide to create a closed circuit for pneumatic sample transfer from the collection cup to science instruments on the lander. A valve opens a gas tank and the gas flows from that tank into the sample collection cup and down rigid tubing to the science instruments chamber on the lander. A two degree of freedom arm with base actuators is used to deploy the sampler and control its sampling location.

Heness, Andrew B.↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The data generated by this test campaign is intended to inform the design of various volatiles-extracting regolith reactor systems by investigating the viability of sealing system inlets using the soil hopper and feed tube without the use of any mechanical valves. This ‘soil column seal’ concept could be applied regardless of reactor geometry or process. Initial data was collected in ambient lab conditions using both GRC-1 and OB-1a regolith simulants. This data is intended to serve as a baseline –no attempt has been made yet to begin optimizing column parameters to achieve highest possible ∆𝑃.

Jack Stewart↗

Development Unit for In-Space Pneumatic Helium Transfer Compressor

High-pressure gaseous helium (GHe) plays a critical role in spacecraft propulsion due to its near exclusive use for pressurization of propellant tanks. Several different designs for helium compressor technologies have been developed for use on Earth; however, significant design changes are required to meet the power, thermal/heat dissipation, vacuum, vibration/shock, size, mass, and efficiency requirements needed for space and launch environments. Currently, no capability exists for mass efficient on-orbit GHe (or xenon) transfer, nor has it ever been attempted. This effort proposed several challenging requirements for the vendor to develop a one-of-a-kind pneumatic compressor prototype. In order to develop a compressor prototype at a TRL 4, a partnership with Air Squared, Inc. was established. This CIF project concluded with the receipt of a prototype along with a proposed design for a flight unit; however, it will not be built due to funding limitations. The vendor had moderate success with initial testing of the prototype at lower pressures (with shimming configured for low pressure). There were delays with testing since the unit was built for higher pressures and the low pressure shimming was challenging to implement. It was found that operation of the compressor at lower pressures caused increased friction on the motor shaft which resulted in the unit drawing more power (current). This was initially thought to be a motor or controller defect. Subsequent high pressure testing at KSC showed that the friction was reduced for the optimal design point (with a high pressure shimming configuration) and the motor (and controller) performed nominally. Following the vendor testing, the unit was tuned/shimmed for a nominal inlet pressure and shipped to KSC for high pressure testing using the custom-designed setup in the Vehicle Assembly Building. The unit performed well, showing the capability to achieve over higher pressure of compression. The pressure differential could likely increase, however, the maximum output of the power supply used for testing was reached, limiting the compressor motor’s capability. Following the GN2 testing, the test setup was converted to GHe with at high pressure. It was shown that although the unit was unable to achieve similar high pressure differentials due to reverse leakage of the GHe through the scroll tip seals, it did achieve the desired GHe compression. This may still be useful for some applications, however, for the purpose of on-orbit GHe transfer, the single stage design would need to be changed to include multiple stages to achieve the compression goals initially proposed by the project.

Brian Nufer↗

PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

Environmental Molecular Sciences Laboratory↗

Pneumatic System for the Neutron Generator Facility at SRNL

A neutron generator system equipped with a pneumatic sample transfer system, enables scientists to perform neutron activation analysis with increased efficiency and accuracy. The samples are placed in sealed containers called 'rabbits' and are passed through the system. Once sealed in the rabbit, the samples are loaded into the tubes via a hopper mechanism. The sample is launched into the generator with compressed air and captures neutrons, causing the sample to become radioactive. Next, the sample is sent to a detector, where the samples are counted for a set length of time on a Ge detector. Once the detection is completed, the sample is then sent to the trash. The system utilizes an interface to select which generator valve and detector location to send the sample too. This project is supports the future development of the neutron generator in the F wing of 773-A. A program is used to automate the passing of the rabbit through the system. The user is able to select the generator valve and detector to be utilized in the testing of the sample. Using the 'Add Rabbit' button the user can add as many sample rabbits to rabbit editor tab. Characteristics are then entered into the fields for each rabbit. The Pre-Det Cooldown and Post-Det Cooldown are intervals used to space out the time before the rabbit is sent into and out of the detector. After all characteristics are entered, the 'Submit to Hopper' button is selected thus preparing the program to run the rabbits in the inserted order. Small setup of the system using the available parts. Simulates the movement of the rabbit from the generator to the detector. Small valves are located before each manifold. To transport the rabbit from one side to the other, the valve of the sending side must be open and the receiving side must be closed. The manifold and valve in direct line with the compressor would extend to the hopper. Once the hopper is loaded, the valve would be open to send the rabbit to generator. Additional manifolds and other mechanical parts are necessary to complete the system design. To complete the construction of the system additional parts, such as the mechanical parts for the switching mechanism and the solenoid valves, are necessary. Further, to complete the automatization of the system, an Arduino is required to communicate with the valves and adjust the linear servos appropriately so that the rabbits are sent to the selected generator location and detector. This work is aimed to be completed in the next fiscal year.

42 ENGINEERING↗

A mixture theory formulation for hydraulic or pneumatic transport of solid particles

In this paper, we discuss the importance of constitutive modeling of the stress tensors in certain engineering issues, related to the pressure drop and skin friction, encountered in solids transport. To study this problem, we first give a brief account of the formulation of a two-component mixture based on the theory proposed by Massoudi, Rajagopal and co-workers. The mixture consists of a linearly viscous fluid infused with solid particles. The solids particles are modeled as a granular media and it is assumed that the mixture is dense enough so that we can use the theory of interacting continua. The subsequent boundary value problem, flow between two flat plates, is then solved numerically and results for various dimensionless numbers are presented for velocities and volume fraction profiles. The engineering quantities of interests discussed are related to the pressure drop and skin friction at the walls.

97 MATHEMATICS AND COMPUTING↗

Change in Limiting Channel Dimensions during Pneumatic Shaping of Multilayer Structures

A mathematical model is developed for determining the inert-gas pressure within rectangular channels in multilayer structures. The model permits calculation of the pressure, stress, and damage in the shaping of materials with different properties. The influence of the relative channel height on the relative limiting rounding radius of a corner element and the membrane thickness and also on the failure time for titanium (VT6S) and aluminum (AMg6) alloys is investigated. The deformation processes are described by the energetic and kinetic theories of creep and damage for viscous flow.

42 ENGINEERING↗

Detailed Study of the Transient Rod Pneumatic System on the Annular Core Research Reactor

The Annular Core Research Reactor Facility (ACRRF) at Sandia National Laboratories (SNL) houses the Annular Core Research Reactor (ACRR), which is a TRIGA design with a few modifications by General Atomics and SNL. Being a TRIGA design, the reactor operates in either steady-state or pulse mode, the latter caused by rapid ejection of three transient rods (TRs) with attached poison rods from the reactor core. The primary mission of the ACRR is to provide a significant flux of high energy neutrons into a dry central cavity for experiments. This research was prompted by intermittent failures in the dashpot rod in TR A. Throughout the 40+ year history of operation, all TRs have failed but TR A has exhibited an increased rate of failure as compared to TR B and C. The research presented here is a foundation for understanding why TR A is failing more often. This paper focuses on the analysis of a pressure distribution and derives from it displacement and timing of the TRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental and analytical evaluation of a hydro-pneumatic compressed-air Ground-Level Integrated Diverse Energy Storage (GLIDES) system

In recent times, there has been a significant increase in intermittent renewable electricity capacity additions to the generation mix. This, coupled with an aging electrical grid that is poorly equipped to handle the ensuing mismatch between generation and use, has created a strong need for flexible, advanced bulk energy storage technologies. In this paper, one such technology recently invented and demonstrated at Oak Ridge National Laboratory is introduced and characterized. Similar to compressed-air energy storage, the Ground-Level Integrated Diverse Energy Storage (GLIDES) technology is based on gas compression/expansion, however, liquid-piston compression and expansion are utilized. In common with pumped-storage hydroelectricity, hydraulic turbomachines (pump/turbine) are utilized for energy storage and recovery, however, pressure vessels are utilized to create artificial elevation (head) difference, allowing pressure head of several thousands of feet to be reached. Furthermore, this paper reports on the experimental performance of the first GLIDES proof-of-concept prototype, and presents formulation and results from a validated physics-based simulation model.

25 ENERGY STORAGE↗

Benchmarking the repeatability of a pneumatic cyclic neutron activation analysis facility using 16 O(n,p) 16 N for nuclear forensics

A target was prepared for cyclic neutron activation analysis by heat sealing lithium-carbonate in polyethylene. The target was cyclically irradiated 50 times using a Thermo-Scientific accelerator based deuterium–tritium fusion neutron generator. During counting periods, gamma-rays emitted by 16 N were detected using three high-purity germanium detectors acquiring data in list-mode. Total counts acquired in each spectrum were compared between the three detectors to examine variability in geometric positioning of the target and variability of the generator intensity throughout the experiment. These two effects were determined to be the primary sources of variation in the measured counts. Variation in target positioning and generator intensity were found to increase the standard deviation by 34% and 33%, respectively. Transit times to the detector were found to be slower and more variable than transit to the generator but were well below the half second threshold needed to measure short-lived radionuclides with half-lives on the order of seconds. The standard deviation in irradiation time was found to be less than 1 milliseconds. The impact on statistical variability in the measured counts was negligible relative to the two primary sources of variation. Spectra acquired from each cycle were summed together. The sum of the peak areas from the 6.1 MeV gamma-ray and its corresponding single and double escape peaks were used to measure the half-life of 16N. The result of 7.108(15) seconds derived from data suggests that the currently published value of 7.13(2) seconds has minimal systematic bias induced by background.

43 PARTICLE ACCELERATORS↗