Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Interpretation and implementation of an ion sensitive probe as a plasma potential diagnostic

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials ({Phi}{sub P}) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii ({rho}{sub i}/{rho}{sub e}{approx}60) to reduce the electron collection at a collector recessed behind a separately biased wall distance {approx}{rho}{sub i}. We develop a new ISP method to measure the plasma potential that is independent of the precise position and shape of the collector. {Phi}{sub P} is found as the wall potential when charged current to the probe collector vanishes during the voltage sweep. The plasma potentials obtained from the ISP match {Phi}{sub P} measured with an emissive probe over a wide range of plasma conditions in a small magnetized plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical emission diagnostics of plasmas in chemical vapor deposition of single-crystal diamond

A key aspect of single crystal diamond growth via microwave plasma chemical vapor deposition is in-process control of the local plasma–substrate environment, that is, plasma gas phase concentrations of activated species at the plasma boundary layer near the substrate surface. Emission spectra of the plasma relative to the diamond substrate inside the microwave plasma reactor chamber have been analyzed via optical emission spectroscopy. The spectra of radical species such as CH, C{sub 2}, and H (Balmer series) important for diamond growth were identified and analyzed. The emission intensities of these electronically excited species were found to be more dependent on operating pressure than on microwave power. Plasma gas temperatures were calculated from measurements of the C{sub 2} Swan band (d{sup 3}Π → a{sup 3}Π transition) system. The plasma gas temperature ranges from 2800 to 3400 K depending on the spatial location of the plasma ball, microwave power and operating pressure. Addition of Ar into CH{sub 4}+H{sub 2} plasma input gas mixture has little influence on the Hα, Hβ, and Hγ intensities and single-crystal diamond growth rates.

36 MATERIALS SCIENCE↗

Synthetic diagnostics platform for fusion plasmas (invited)

A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C{sup 1} are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP’s capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C{sup 1} output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Radiography for the Diagnostics of a Dense Plasma

The possibility of using high-energy proton radiography for dense plasma diagnostics is discussed. The designed telescopic ion optical system for a proton radiography installation with a 1 GeV beam is presented. The schematic diagram of the proton microscope is given. It is shown that the estimate of spatial resolution for the installation obtained with consideration of chromatic aberrations of magnetic quadrupole lenses is limited from below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Particles as Electrostatic Probes for Plasma Sheath Diagnostic

An interesting aspect in the research of complex (dusty) plasmas is the experimental study of the interaction of micro-particles of different sizes with the surrounding plasma for diagnostic purpose. In the plasma micro-disperse particles are negatively charged and confined in the sheath. The particles are trapped by an equilibrium of gravity, electric field force and ion drag force. From the behavior, local electric fields can be determined, e.g. particles are used as electrostatic probes. In combination with additional measurements of the plasma parameters with Langmuir probes and thermal probes as well as by comparison with an analytical sheath model, the structure of the sheath can be described. In the present work we focus on the behavior of micro-particles of different sizes and several plasma parameters e.g. the gas pressure and the rf-power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, portable, laser induced fluorescence diagnostic for laboratory plasma sources

As diagnostic groups are increasingly called upon to participate in experimental campaigns at remote facilities, there is a need to develop portable versions of plasma diagnostic systems. One such diagnostic is laser induced fluorescence (LIF). Here, we describe a portable LIF apparatus that eliminates the need for an optical table, beam splitters, and an optical chopper. All of the light exiting the laser system is coupled through optical fibers to the experiment and housekeeping diagnostics. Here, the collected light is coupled through an optical fiber as well. A key feature is modulation of the tapered amplifier current instead of physical modulation of the laser output. Using this portable LIF system, measurements of ion temperature, ion flow, and relative metastable ion density are reported for two different remote experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics of silane and germane radio frequency plasmas by coherent anti-Stokes Raman spectroscopy

In situ plasma diagnostics using coherent anti-Stokes Raman spectroscopy have shown different dissociation characteristics for GeH4 and SiH4 in radio frequency (rf) plasma-enhanced chemical vapor deposition of amorphous silicon germanium alloy (a-SiGe:H) thin films. The GeH4 dissociation rate in rf plasmas is a factor of about 3 larger than that of SiH4. Plasma diagnostics have revealed that the hydrogen dilution of the SiH4 and GeH4 mixed plasma plays a critical role in suppressing the gas phase polymerization and enhancing the GeH4 dissociation.

Perry, Joseph W.↗

Design and testing of miniaturized plasma sensor for measuring hypervelocity impact plasmas

An increasingly notable component of the space environment pertains to the impact of meteoroids and orbital debris on spacecraft and the resulting mechanical and electrical damages. Traveling at speeds of tens of km/s, when these particles, collectively referred to as hypervelocity particles, impact a satellite, they vaporize, ionize, and produce a radially expanding plasma that can generate electrically harmful radio frequency emission or serve as a trigger for electrostatic discharge. In order to measure the flux, composition, energy distribution, and temperature of ions and electrons in this plasma, a miniaturized plasma sensor has been developed for carrying out in-situ measurements in space. The sensor comprises an array of electrostatic analyzer wells split into 16 different channels, catering to different species and energy ranges in the plasma. We present results from numerical simulation based optimization of sensor geometry. A novel approach of fabricating the sensor using printed circuit boards is implemented. We also describe the test setup used for calibrating the sensor and show results demonstrating the energy band pass characteristics of the sensor. In addition to the hypervelocity impact plasmas, the plasma sensor developed can also be used to carry out measurements of ionospheric plasma, diagnostics of plasma propulsion systems, and in other space physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Omegatron mass spectrometer in a hydrogen/deuterium detached plasma

Diagnostics of the relative concentrations of the atomic and molecular ions were carried out in hydrogen/deuterium plasma with hydrogen/deuterium gas puff in the linear plasma device, TPD-SheetIV. An omegatron ion mass spectrometer is used for analyzing ion species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and X-ray Diagnostics for Plasma Position Measurements in the Ignition Experiment Ignitor

The ignition experiment Ignitor will produce high performance plasma regimes with neutron fluxes at the first wall comparable to those expected in power generating reactors (10{sup 15} n/ cm{sup 2}/ s at the first wall). An appreciable degradation of the inorganic insulators surrounding the conductors is expected and the measurement of basic plasma parameters, such as plasma current and position, by electromagnetic diagnostics can become problematic. Thus an R and D program, aimed at the development of effective and affordable devices for electromagnetic diagnostics with higher damage threshold, is being carried out. Prototype diagnostic coils of different shapes have been manufactured, in collaboration with SALENTEC and Universita di Lecce. At the same time, an alternative plasma position control method is being explored, based on the diffraction and detection of the soft X-ray radiation emitted, mostly by Molybdenum impurities, near the top or bottom of the plasma column, where the distance of the plasma last closed magnetic surface from the wall is only few millimeters. The underlying principles and general layout of the new system is essentially an adaptation of a 2-dimensional curved crystal spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved chopping of a lithium beam for plasma edge diagnostic at ASDEX Upgrade

The lithium beam diagnostic at ASDEX Upgrade routinely delivers electron density profiles in the plasma edge by lithium beam impact excitation spectroscopy. An accurate background subtraction requires a periodically chopped lithium beam. A new, improved chopping system was developed and installed. It involves a voltage modulation for the extractor electrode and the beam deflection plates. The modulation of the extractor electrode reduces the unused portion of lithium ions and improves the stability of the beam with respect to its position. Furthermore, the data indicate an extended emitter lifetime. The extractor chopping was also found to be insensitive to sparks. The deflection chopping experiments demonstrated beam chopping in the kilohertz range. The significantly higher modulation frequency of the deflection chopping improves background subtraction of fast transient events. It allows a more accurate density measurements in the scrape off layer during impurity injections and edge localized modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

L-shell spectroscopy of Au as a temperature diagnostic tool

In order to develop plasma diagnostic for reduced-size hot Hohlraums under laser irradiation, we have studied the L-shell emission from highly charged gold ions in the SuperEBIT electron beam ion trap. The resolving power necessary to identify emission features from individual charge states in a picket-fence pattern has been estimated, and the observed radiation features have been compared with atomic structure calculations. We find that the strong 3d{sub 5/2}{yields}2p{sub 3/2} emission features are particularly useful in determining the charge state distribution and average ion charge <Z>, which are strongly sensitive to the electron temperature.

07 ISOTOPE AND RADIATION SOURCES↗

Plasma Channel Diagnostic Based on Laser Centroid Oscillations

A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. The centroid position of low-intensity (<10{sup 14}Wcm{sup -2}) laser pulses focused at the input of a hydrogen-filled capillary discharge waveguide was scanned and the exit positions recorded to determine the channel shape and depth with an accuracy of a few %. In addition, accurate alignment of the laser beam through the plasma channel can be provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.

43 PARTICLE ACCELERATORS↗