Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Sub-nanosecond ranging possibilities of optical radar at various signal levels and transmitted pulse widths

The behavior of the photomultiplier is considered, as well as the method of derivation of the photomultiplier output pulse and its relation to the reflected light pulse width and amplitude, and the calibration of range precision and accuracy. Pulsed laser radars with light pulse widths of 30, 3, and 0.1 nanosec a considered, with the 0.1 nanosec system capable of highest precision in several modes of operation, including a high repetition rate, single photoelectron reception mode. An alternate calibration scheme using a fast, triggerable light pulser is described in detail.

Poultney, S. K.↗

Turbulence measurements using the laser Doppler velocimeter.

The photomultiplier signal representing the axial velocity of water within a glass pipe is considered. It is shown that with proper analysis of the photomultiplier signal, the turbulent information that can be obtained in liquid flows is equivalent to results obtained in recent hot film studies. In shear flows the signal from the laser Doppler velocimeter contains additional information which may be related to the average shear.

Dunning, J. W., Jr.↗

Side-viewing detector for a vacuum ultraviolet reflectometer.

The problem of detector response, which arises in the application of the reflectance vs angle of incidence method to the determination of optical constants in the vacuum UV spectral region is discussed. The analysis is performed for the side-viewing 1P21 detector sensitized with sodium salycilate. To take advantage of the wide selection photomultipliers available in the end-on configuration, a scheme for converting the end-on types to a side viewing geometry with a response uniform over several degrees of detector rotation is developed. It consists of a 32-mm diam spherical collector, located at the end of a cylindrical photomultiplier holder, with 12-mm entrance and viewing ports and a position for the sensitized screen also 12-mm in diameter.-

Osantowski, J. F.↗

The Uhuru star aspect sensor.

Description of the star sensor used in the spin-stabilized Uhuru satellite for the purpose of detecting and locating stellar X-ray sources. The star sensor had the capability of detecting fourth-magnitude stars to within 1 arc minute of azimuth and 2 arc minutes of elevation. This was achieved with the aid of a slightly modified 76-mm, f/0.87 Super Farron lens, an 'n' shaped reticle located in the focal plane, and an RCA CF70114F photomultiplier serving as the detection element. The star sensor is composed of three major components - a high-voltage power supply, the photomultiplier, and an amplifier.

Jagoda, N.↗

High data rate optical transceiver terminal

The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.

Clarke, E. S.↗

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

A lidar system for remote probing of the lower atmosphere

The development and characteristics of a lidar system for atmospheric measurements are discussed. The lidar system employs a Q-switched ruby laser that radiates an intense pulse of light into the atmosphere to illuminate aerosol particles in the laser beam. Light backscattered from the particles is received by a Cassegrain telescope equipped with a sensitive photomultiplier tube. The output signal of the photomultiplier tube is displayed on an oscilloscope and recorded on polaroid film.

Craig, C. D.↗

Certain problems in the development and design of scintillation and Cerenkov counters

The feasibility is examined of increasing the effectiveness of the scintillation and Cerenkov counters through improving light collection of the recorded radiation on the photoelectric cathode of the photomultiplier. An example of how to select a detector of the directional plexiglas Cerenkov counter is given. Also presented are experimentally obtained amplitude distributions during the recording of cosmic ray muons. The necessity to obtain agreement between the characteristic spectrum of the photocathode of the photomultiplier and the spectrum of the recorded radiation is stressed.

Chukin, V. S.↗

The detection of high charge cosmic ray nuclei

A large-area, light-weight electronic particle telescope was flown on a high altitude balloon in the summer of 1974 to study the heavy nuclei in the cosmic radiation. This telescope consisted of a double Cerenkov-double scintillator array composed of four 1.22 m diameter disk radiators mounted in light diffusion boxes, each looked at by multiple photomultipliers. The impact point of each particle on the scintillation radiators was determined by studying the relative signals observed by three equally spaced peripheral photomultipliers and one mounted at the center of the diffusion boxes. This telescope was flown in a configuration having a geometric factor of 0.45 sq m sr and observed some 5 x 10 to the 4 nuclei with Z exceeding 14 in a 11 hr exposure. The response and sensitivity of this telescope are discussed in detail.

Scarlett, W. R.↗

The nuclear radiation monitor for the Spacelab/Shuttle

A 5 inch by 5 inch diameter sodium iodide scintillation crystal, viewed by a 5 inch photomultiplier was designed to be mounted near the center of the shuttle payload bay to quantitatively measure the neutron and gamma ray environment during the second Spacelab mission. The expected energy resolution is 8% FWHM at 662 keV. The detector will operate in an energy range from 0.1 to 20 MeV. A charged anticoincidence shield consisting of a 1 cm thick plastic scintillator viewed by three 2 inch photomultiplier tubes, covers the crystal detector which has nearly omnidirectional response.

Fishman, G. J.↗

A voltage to frequency converter for astronomical photometry

A voltage to frequency converter (VFC) for general use with photomultipliers is described. For high light levels, when the dead-time corrections for a photon counter would be excessive, the VFC maintains a linear response and allows the recording of data at high time resolution. Results of laboratory tests are given for the signal-to-noise characteristics, linearity, stability, and transient response of the VFC when used in conjunction with EMI 9658 and RCA C31034 photomultipliers.

Dunham, E.↗

The digital control of an experiment to size particles using a laser

Efforts to automate an experiment for sizing particles using a laser is described. The objective of the experiment was to rotate a photomultiplier detector at various angles and to record data associated with how light interacted with a particle. The light source was a laser which was fixed in space. The design consisted of a step motor with a fabricated electromechanical system to rotate the photomultiplier. The use of an 8080 microprocessor based microcomputer to control the step motor and to log data is described.

Cross, J. E.↗

Detectors for energies less than 10 MeV

In the energy domain 100 keV to 10 MeV, both crystal scintillations and semiconductors are widely used for gamma ray detectors in spectrometer systems. These detectors' operation depend on the fact that gamma rays lose energy by ionization in these materials and electrons and holes are produced. In the case of semiconductors, these electrons and holes are collected by an electric field, and they provide an electric signal that is a direct measure of the energy lost by the gamma ray in the material. Scintillation detectors depend on a further conversion of the energy lost in electron hole pair production to the production of photons. A photomultiplier tube measures the intensity of the photon flux, and an electrical pulse proportional to the photon intensity is produced at the photomultiplier output.

Source record↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗

Position measurements for heavy ion beams using a sodium iodide scintillator

A 50 cm diameter, 1.7 cm thick disc of NaI scintillator has been mounted to permit edge viewing by four photomultipliers. Energetic heavy ions passing through the scintillator at different positions cause a variation in the division of light among the photomultipliers. A performance close to the expected limit for 670 MeV/n neon has been achieved. Calculations of expected response using an optical model agree well with the measurements.

Buffington, A.↗

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.↗

Space radiation studies for the reporting period, June 1983 - July 1984

Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight in December 1983, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the VFI, it could be established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approximately 60% of the flight and it appears that this is the total available. The next phase of effort will involve close collaboration with Space Science Laboratory, MSFC, in the analysis of this data. The Nuclear Radiation Monitor (NRM) was under assembly and testing at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured.

Source record↗