High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Reconstructing 3D asymmetries in laser-direct-drive implosions on OMEGA

Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal density distribution present in laser-direct-drive inertial con finement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. Here, the uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 0.7 to < 0.4 keV.

47 OTHER INSTRUMENTATION↗

Pentagonal prism spherical hohlraums for OMEGA

A new configuration is proposed for spherical hohlraums on OMEGA in which seven laser entrance holes (LEHs) are used—five around the equator and one at each pole [Farmer et al., Phys. Plasmas 26, 032701 (2019)]. This is known as the PEPR (pentagonal prism) hohlraum. A new view-factor code LORE is used to model the PEPR hohlraum and compare its performance with tetrahedral hohlraums shot on OMEGA. With optimization of beam pointings, the PEPR hohlraum produces a nonuniformity ranging from 1.1% (rms) at low albedos to 0.6% at high albedos. The tradeoffs between hohlraum-to-capsule ratio, uniformity, and background radiation temperature have been explored, and it has been shown that larger LEH radii on the poles can result in a modest improvement in uniformity. Here, the seven-hole PEPR hohlraum is well matched to the OMEGA symmetry and promises to provide insight into the performance of spherical hohlraums including octahedral (six-LEH) hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Causes of fuel–ablator mix inferred from modeling of monochromatic time-gated radiography of OMEGA cryogenic implosions

Here, we present evidence, in the context of OMEGA cryogenic target implosions, that laser imprint, known to be capable of degrading laser-direct-drive target performance, plays a major role in generating fuel–ablator mix. OMEGA cryogenic target implosions show a performance boundary correlated with acceleration-phase shell stability; for sufficiently low adiabats (where the adiabat is the ratio of the pressure to the Fermi pressure) and high in-flight aspect ratios (IFAR's), the neutron-weighted shell areal density and neutron yield relative to the clean simulated values sharply decline. Direct evidence of Rayleigh–Taylor fuel–ablator mixing was previously obtained using a Si Heα backlighter driven by an ~20-ps short pulse generated by OMEGA EP. The shadow cast by the shell shortly prior to stagnation, as diagnosed using backlit radiographs, shows a softening near the limb, which is evidence of an ablator–fuel mix region for a low-adiabat implosion (α ~ 1.9, IFAR = 14) but not for a moderate adiabat implosion (α ~ 2.5, IFAR = 10). We find good agreement between experimental and synthetic radiographs in simulations that model laser imprint and account for uncertainty in the initial ablator thickness. Furthermore, we further explore the role of other mechanisms such as classical instability growth at the fuel–ablator interface, species concentration diffusion, and long-wavelength drive and target asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

Identification of stimulated Raman side scattering in near-spherical coronal plasmas on OMEGA EP

Recent spherical-target laser–plasma interaction experiments, performed on the OMEGA EP laser, have been analyzed for stimulated Raman scattering (SRS). This has been motivated by results obtained on the National Ignition Facility (NIF) that have demonstrated the importance of SRS, and in particular SRS side scatter, for directly driven inertial confinement fusion (ICF) conditions [Rosenberg et al. Phys. Rev. Lett. 120, 055001 (2018); Michel et al. Phys. Rev. E 99, 033203 (2019)]. The analysis, based on a generalized ray tracing approach, is described and is shown to explain the observed scattered light spectra: it identifies SRS convective scattering, from portions of each incident beam where the scattered electromagnetic wave is generated in the direction parallel to contours of constant density, as the dominant contribution. This result is novel, as SRS is mostly associated with plasmas of higher electron temperature (T e ≳ 3–4 keV) and longer density scale length (≳600 μ m) than those considered here (T e ~ 1–3 keV, Ln~150 μm) for the relevant overlapped irradiation intensities l ≲ 10 15 W/cm 2 . Furthermore, a combination of the high single-beam intensity on OMEGA EP and the side-scattering geometry, that has been identified, is responsible for this result. It is further suggested that the OMEGA EP platform could provide a good surrogate in which to develop SRS mitigation strategies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of overlapping laser beams and density scale length in laser-plasma instability experiments on OMEGA EP

Experiments have been conducted on the OMEGA EP laser facility to study the effect of density scale length and overlapping beam geometry on laser-plasma instabilities near and below the quarter-critical density. Experiments were conducted in both planar geometry (density scale length L n ~ 190 to 300 μm) and spherical geometry (L n ~ 150 μm) with up to four overlapping beams and were designed to have overlapped intensities and density scale lengths comparable to OMEGA spherical experiments, but with many fewer beams. In comparison with previous experiments on OMEGA and National Ignition Facility, it is confirmed that shorter density scale lengths favor the two-plasmon decay (TPD) instability, while longer density scale lengths favor stimulated Raman scattering (SRS). In addition, for experiments at the same scale length and overlapped laser intensity, higher single-beam intensities favor SRS, while a larger number of overlapping beams favor TPD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-generated magnetic fields in the hot spot of direct-drive cryogenic implosions at Omega

This work reports that Biermann self-generated magnetic fields of ≈200 MG and Hall parameters of ≈1.5 are produced in the stagnation phase of direct-drive cryogenic implosions at Omega. The magnetic fields produce a drop of 2.4% in fusion yield and 1% in ion temperature. A quantitative estimate of the effect of self-generated magnetic fields on yield and ion temperature is essential, since direct measurements of these fields are not available. Reconstructed simulations of the 50 Gbar implosions, with all the stagnation measurements reproduced simultaneously by a combination of mid- and low-mode asymmetries as degradation mechanisms [Bose et al., Phys. Plasmas 25, 062701 (2018)], are used to obtain the estimates. The magnetic fields cause a decrease in yield due to the Righi–Leduc heat flow, which exceeds any benefits from heat flow suppression due to magnetization. It is important to note that both direct-drive Omega-scale implosions and indirect-drive National Ignition Facility (NIF)-scale implosions [Walsh et al., Phys. Rev. Lett. 118, 155001 (2017)] produce similar estimates for the magnetic field strength, and both show a decrease in fusion yield, with the Righi–Leduc transport as the loss mechanism. However, the yield degradation at Omega is small and lower by ≈5× compared to the indirect-drive ignition-scale NIF estimate.

Physics↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Progress toward hydro-equivalent ignition in OMEGA direct-drive DT-layered implosions

Considerable progress has been made in deuterium-tritium-layered implosion experiments on the OMEGA Laser System, bringing the prospects for thermonuclear ignition in direct-drive configurations with megajoule-class lasers closer to reality. Doing so has required navigating the balance between improved 1D performance and multidimensional stability. Using statistical modeling based on over 350 cryogenic implosions to identify various degradation mechanisms, and combined with multidimensional simulations and experimental techniques such as target offsets to combat residual flows, core conditions have repeatably been achieved that extrapolate to the burning-plasma state when scaled to 2.15 MJ of symmetric laser illumination. Using high implosion velocities (⁠> 450 km/s) and moderately high adiabats (⁠~5⁠), these experiments produced record-high scaled Lawson parameters in direct drive equal to 89 ± 2% of that required for ignition with expected yields of up to 1.5 ± 0.2 MJ. To improve these results still further, focused physics studies are performed to improve physics understanding and identify routes to even greater performance. Recent studies include investigations into the impact of mounting features, laser imprint, reduced fuel temperatures, and greater on-target intensities through subscale experiments. This manuscript gives a summary of the cryogenic direct-drive program on the OMEGA laser, including routes taken to achieve the current best performance, the status of recent focused physics investigations, and future designs—such as target solutions to laser imprint and reducing vapor density to increase convergence—that are expected lead to the demonstration of hydro-equivalent ignition on OMEGA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-mode nonuniformity in direct-drive ICF implosions due to laser smoothing techniques employed on OMEGA

For successful laser-direct-drive inertial confinement fusion implosions, the laser irradiation must be highly uniform over the target surface. On OMEGA, multiple laser beams are used to illuminate targets quasi-uniformly. High-mode-number nonuniformities due to laser speckle on each individual beam are reduced by splitting each beam into two orthogonal polarizations (i.e., polarization smoothing, or PS) and a range of wavelengths (i.e., smoothing by spectral dispersion) that are dispersed at the target plane. However, cross-beam energy transfer (CBET) is sensitive to both the polarizations and wavelengths of the interacting beams, so the interplay between CBET and the laser-smoothing schemes results in unique intensity variation across each beam profile, which is a systematic source of low-mode drive nonuniformity on OMEGA. Here, we model these effects and find that the predicted ℓ = 1 mode in the laser-absorption distribution is consistent with the systematic core-flow direction that has been determined from the OMEGA implosion database. We also observe good agreement with the measured core-flow directions for two specific sets of implosions (one with PS, the other without PS) when we also account for the measured beam mispointing and the beam power imbalance.

Crossed beam scattering↗

Nuclear activation analysis of zirconium-90 isomeric and ground-state reactions at the OMEGA Laser Facility

Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.

Activation analysis↗

Approximation of periodic functions in the classes H{sub q}{sup {Omega}} by linear methods

The following result is proved: if approximations in the norm of L{sub {infinity}} (of H{sub 1}) of functions in the classes H{sub {infinity}}{sup {Omega}} (in H{sub 1}{sup {Omega}}, respectively) by some linear operators have the same order of magnitude as the best approximations, then the set of norms of these operators is unbounded. Also Bernstein's and the Jackson-Nikol'skii inequalities are proved for trigonometric polynomials with spectra in the sets Q(N) (in {Gamma}(N,{Omega})). Bibliography: 15 titles.

97 MATHEMATICS AND COMPUTING↗

Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, and the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEW LIMITS ON AN INTERMEDIATE-MASS BLACK HOLE IN OMEGA CENTAURI. I. HUBBLE SPACE TELESCOPE PHOTOMETRY AND PROPER MOTIONS

We analyze data from the Hubble Space Telescope's (HST) Advanced Camera for Surveys of the globular cluster (GC) Omega Cen. We construct a photometric catalog of 1.2 x 10{sup 6} stars over a 10' x 10' central field down to below B{sub F435W} = 25 (M {approx} 0.35 M{sub sun}). The 2.5 to 4 year baseline between observations yields a catalog of some 10{sup 5} proper motions over a smaller area, with 53,382 'high-quality' measurements in a central R {approx}< 2' field. Artificial-star tests characterize the photometric incompleteness. We determine the cluster center to {approx}1'' accuracy from star counts using two different methods, one based on isodensity contours and the other on 'pie slices'. We independently confirm the result by determining also the kinematical center of the HST proper motions, as well as the center of unresolved light seen in Two Micron All Sky Survey data. All results agree to within their 1''-2'' levels of uncertainty. The proper-motion dispersion of the cluster increases gradually inward, but there is no variation in kinematics with position within the central {approx}15'': there is no dispersion cusp and no stars with unusually high velocities. We measure for the first time in any GC the variation in internal kinematics along the main sequence. The variation of proper-motion dispersion with mass shows that the cluster is not yet in equipartition. There are no differences in proper-motion kinematics between the different stellar populations of Omega Cen. Our results do not confirm the arguments put forward by Noyola, Gebhardt, and Bergmann to suspect an intermediate-mass black hole (IMBH) in Omega Cen. They determined line-of-sight velocity dispersions in two 5'' x 5'' fields, and reported higher motions in their central field. We find the proper-motion kinematics to be the same in both fields. Also, we find that they (as well as other previous studies) did not accurately identify the cluster center, so that both of their fields are in fact 12'' from the true center. We also do not confirm the central density cusp they reported (in part due to the different center, and in part due to biases induced by their use of unresolved light). The surface number-density distribution near the center does not differ strongly from a single-mass King model, although a shallow cusp may not be ruled out. In the companion paper, which is Paper II in this series, we present new dynamical models for the high-quality data presented here, with the aim of putting quantitative constraints on the mass of any possible IMBH.

79 ASTRONOMY AND ASTROPHYSICS↗