Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analysis of Near-Field Magnetic Responses on ZrTe 5 through Cryogenic Magneto-THz Nano-Imaging

One manifestation of light-Weyl fermion interaction is the emergence of chiral magnetic effects under magnetic fields. Probing real space magnetic responses at terahertz (THz) scales is challenging but highly desired, as the local responses are less affected by the topologically trivial inhomogeneity that is ubiquitous in spatially averaged measurements. Here, we implement a cryogenic THz microscopy instrument under a magnetic field environment—a task only recently achieved. We explore the technical approach of this system and characterize the magnetic field’s influence on our AFM operation by statistical noise analysis. We find evidence for local near-field spatial variations in the topological semimetal ZrTe 5 up to a 5-Tesla magnetic field and obtain near-field THz spectra to discuss their implications for future studies on the chiral magnetic effect.

36 MATERIALS SCIENCE↗

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring dark matter substructure with astrometric lensing beyond the power spectrum

Abstract Astrometry—the precise measurement of positions and motions of celestial objects—has emerged as a promising avenue for characterizing the dark matter population in our Galaxy. By leveraging recent advances in simulation-based inference and neural network architectures, we introduce a novel method to search for global dark matter-induced gravitational lensing signatures in astrometric datasets. Our method based on neural likelihood-ratio estimation shows significantly enhanced sensitivity to a cold dark matter population and more favorable scaling with measurement noise compared to existing approaches based on two-point correlation statistics. We demonstrate the real-world viability of our method by showing it to be robust to non-trivial modeled as well as unmodeled noise features expected in astrometric measurements. This establishes machine learning as a powerful tool for characterizing dark matter using astrometric data.

convolutional neural networks (1938)↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-area low-noise flexible organic photodiodes for detecting faint visible light

Silicon photodiodes are the foundation of light-detection technology; yet their rigid structure and limited area scaling at low cost hamper their use in several emerging applications. A detailed methodology for the characterization of organic photodiodes based on polymeric bulk heterojunctions reveals the influence that charge-collecting electrodes have on the electronic noise at low frequency. The performance of optimized organic photodiodes is found to rival that of low-noise silicon photodiodes in all metrics within the visible spectral range, except response time, which is still video-rate compatible. Solution-processed organic photodiodes offer several design opportunities exemplified in a biometric monitoring application that uses ring-shaped, large-area, flexible, organic photodiodes with silicon-level performance.

47 OTHER INSTRUMENTATION↗

Probing anisotropies of the Stochastic Gravitational Wave Background with LISA

Here, we investigate the sensitivity of the Laser Interferometer Space Antenna (LISA) to the anisotropies of the Stochastic Gravitational Wave Background (SGWB). We first discuss the main astrophysical and cosmological sources of SGWB which are characterized by anisotropies in the GW energy density, and we build a Signal-to-Noise estimator to quantify the sensitivity of LISA to different multipoles. We then perform a Fisher matrix analysis of the prospects of detectability of anisotropic features with LISA for individual multipoles, focusing on a SGWB with a power-law frequency profile. We compute the noise angular spectrum taking into account the specific scan strategy of the LISA detector. We analyze the case of the kinematic dipole and quadrupole generated by Doppler boosting an isotropic SGWB. We find that β Ω GW ~ 2 × 10 -11 is required to observe a dipolar signal with LISA. The detector response to the quadrupole has a factor ~ 10 3 β relative to that of the dipole. The characterization of the anisotropies, both from a theoretical perspective and from a map-making point of view, allows us to extract information that can be used to understand the origin of the SGWB, and to discriminate among distinct superimposed SGWB sources.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Density Polyethylene Custom Focusing Lenses for High-Resolution Transient Terahertz Biomedical Imaging Sensors

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.

47 OTHER INSTRUMENTATION↗

Characterization of contaminants in the Lyman-alpha forest auto-correlation with DESI

Baryon Acoustic Oscillations can be measured with sub-percent precision above redshift two with the Lyman-α (Lyα) forest auto-correlation and its cross-correlation with quasar positions. This is one of the key goals of the Dark Energy Spectroscopic Instrument (DESI) which started its main survey in May 2021. We present in this paper a study of the contaminants to the Lyα forest which are mainly caused by correlated signals introduced by the spectroscopic data processing pipeline as well as astrophysical contaminants due to foreground absorption in the intergalactic medium. Notably, an excess signal caused by the sky background subtraction noise is present in the Lyα auto-correlation in the first line-of-sight separation bin. We use synthetic data to isolate this contribution, we also characterize the effect of spectro-photometric calibration noise, and propose a simple model to account for both effects in the analysis of the Lyα forest. We then measure the auto-correlation of the quasar flux transmission fraction of low redshift quasars, where there is no Lyα forest absorption but only its contaminants. We demonstrate that we can interpret the data with a two-component model: data processing noise and triply ionized Silicon and Carbon auto-correlations. This result can be used to improve the modeling of the Lyα auto-correlation function measured with DESI.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Site Amplifications Using Ambient-Noise-Derived Shallow Velocity Structures Under a Dense Array in Oklahoma

The shear-wave velocity (V S ) structure plays an important role in characterizing site amplification. The Large-n Seismic Survey in Oklahoma (LASSO; 1820 stations) revealed large vertical ground-motion variability in a 25 km × 32 km area in northern Oklahoma. The LASSO array has a relatively simple and flat topography, typical in a sedimentary basin environment in the central United States. In this study, we use the dense array to investigate the velocity structure under the LASSO array and how vertical ground motions relate to the shallow-to-deep structures. We extract the fundamental-mode Rayleigh wave by cross-correlating one month of ambient noise (0.7–5 Hz). We use double-beamforming to measure the group and phase velocities and anisotropy. By jointly inverting the group and phase velocities, we obtain the V S structure. Here, we observe correlations between V S at depths of 0.1–1.5 km and vertical ground motions using sites on the stiffer Permian formations. The shallow Quaternary alluvium and terrace deposits can amplify vertical ground motions by a factor of 2–4.5 between 2 and 25 Hz and attenuate signals above 25 Hz. We use 1D V S profiles to simulate the SV-wave transfer functions. An average V S of 250 m/s in the upper 20–40 m may cause the observed amplification between 2 and 40 Hz. V S estimated by topographic slopes cannot predict the relative amplification. Our results highlight the large variability of site-dependent ground motion in a small local region and the importance of characterizing shallow structures to estimate seismic hazards. Small thickness variations of the shallow formation can significantly change the resonance amplitude and frequency, which likely reduces the coherency of the Rayleigh waves extracted from ambient noise.

Chang, Hilary [Massachusetts Inst. of Technology (↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors’ subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 11) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

47 OTHER INSTRUMENTATION↗

Revealing charge carrier dynamics and transport in Te-doped GaAsSb and GaAsSbN nanowires by correlating ultrafast terahertz spectroscopy and optoelectronic characterization

Recent advances in the growth of III-V semiconductor nanowires (NWs) hold great promise for nanoscale optoelectronic device applications. It is established that a small amount of nitrogen (N) incorporation in III-V semiconductor NWs can effectively red-shift their wavelength of operation and tailor their electronic properties for specific applications. Still, understanding the impact of N incorporation on non-equilibrium charge carrier dynamics and transport in semiconducting NWs is critical in achieving efficient semiconducting NW devices. In this work, ultrafast optical pump-terahertz probe spectroscopy has been used to study non-equilibrium carrier dynamics and transport in Te-doped GaAsSb and dilute nitride GaAsSbN NWs, with the goal of correlating these results with electrical characterization of their equilibrium photo-response under bias and low-frequency noise characteristics. Nitrogen incorporation in GaAsSb NWs led to a significant increase in the carrier scattering rate, resulting in a severe reduction in carrier mobility. Carrier recombination lifetimes of 33 ± 1 picoseconds (ps) and 147 ± 3 ps in GaAsSbN and GaAsSb NWs, respectively, were measured. The reduction in the carrier lifetime and photoinduced optical conductivities are due to the presence of N-induced defects, leading to deterioration in the electrical and optical characteristics of dilute nitride NWs relative to the non-nitride NWs. Finally, we observed a very fast rise time of ~2 ps for both NW materials, directly impacting their potential use as high-speed photodetectors.

36 MATERIALS SCIENCE↗

QUBIC II: Spectral polarimetry with bolometric interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q & U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. Finally, we conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct structural retrieval from gas-phase ultrafast diffraction data using a genetic algorithm

Ultrafast scattering techniques such as ultrafast electron diffraction and ultrafast x-ray diffraction have been utilized to elucidate the structural dynamics, reaction intermediates, and final products in molecular reactions following photoexcitation. The time-dependent structures are typically not directly retrieved from the experimental data, but they rely on comparison with calculations. The genetic algorithm (GA), a global optimization strategy, can be used to retrieve the molecular structures directly from diffraction patterns without any theoretical input. However, the robustness of the GA with respect to real experimental conditions such as a limited momentum transfer range, noise, and artifacts has not been studied in detail. In this work, we characterize the performance of the GA with simulated data that mimic realistic experimental conditions. We have developed and implemented a variant of the GA specific to diffraction measurements which performs better in the presence of imperfect data compared to the standard implementation of the GA. We demonstrate this method with both synthetic data and experimental ultrafast electron diffraction data on the UV-induced photodissociation of trifluoroiodomethane (C⁢F 3⁡ I) molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dispersive nonreciprocity between a qubit and a cavity

The dispersive interaction between a qubit and a cavity is ubiquitous in circuit and cavity quantum electrodynamics. It describes the frequency shift of one quantum mode in response to excitations in the other and, in closed systems, is necessarily bidirectional, i.e., reciprocal. Here, we present an experimental study of a nonreciprocal dispersive-type interaction between a transmon qubit and a superconducting cavity, arising from a common coupling to dissipative intermediary modes with broken time reversal symmetry. We characterize the qubit-cavity dynamics, including asymmetric frequency pulls and photon shot noise dephasing, under varying degrees of nonreciprocity by tuning the magnetic field bias of a ferrite component in situ. We introduce a general master equation model for nonreciprocal interactions in the dispersive regime, providing a compact description of the observed qubit-cavity dynamics agnostic to the intermediary system. Our result provides an example of quantum nonreciprocal phenomena beyond the typical paradigms of non-Hermitian Hamiltonians and cascaded systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhancing Coherence Limits in Superconducting Quantum Systems for Computing and Sensing

This talk will highlight recent efforts at the SQMS Center to develop qudit-based quantum computing architectures using superconducting three-dimensional (3D) cavities, as well as the use of these ultra-coherent cavities for quantum sensing. I will present systematic studies of materials and devices aimed at identifying and mitigating the dominant sources of decoherence—including two-level systems (TLS), quasiparticles, and other noise mechanisms—in both transmons and 3D cavities. These investigations include microwave loss characterization of niobium, tantalum, aluminum, their native oxides, and substrate materials such as silicon and sapphire. By combining measurements on qubits and cavities, we disentangle subsystem-specific loss mechanisms and establish a hierarchy of mitigation strategies, leading to transmon coherence times exceeding one millisecond. I will also discuss studies of quasiparticle dynamics, including quasiparticle bursts observed in qubits operated both above ground and at the Gran Sasso underground laboratory, and the observation that applied magnetic fields can suppress temporal T₁ fluctuations. Building on these advances, we demonstrate a record-coherence two-cell cavity-qudit system with coherence times exceeding 20 milliseconds. Leveraging tunable sideband interactions together with error-resilient protocols, including measurement-based error correction and post-selection, we achieve high-fidelity quantum state control, including the preparation of Fock states up to N=20 with fidelities above 95% and the generation of high-fidelity two-mode entangled states. Finally, I will discuss how these ultra-coherent quantum systems are enabling emerging quantum sensing applications, including searches for dark matter and gravitational waves.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

First Sagittarius A* Event Horizon Telescope Results. III. Imaging of the Galactic Center Supermassive Black Hole

We present the first event-horizon-scale images and spatiotemporal analysis of Sgr A* taken with the Event Horizon Telescope in 2017 April at a wavelength of 1.3 mm. Imaging of Sgr A* has been conducted through surveys over a wide range of imaging assumptions using the classical CLEAN algorithm, regularized maximum likelihood methods, and a Bayesian posterior sampling method. Different prescriptions have been used to account for scattering effects by the interstellar medium toward the Galactic center. Mitigation of the rapid intraday variability that characterizes Sgr A* has been carried out through the addition of a “variability noise budget” in the observed visibilities, facilitating the reconstruction of static full-track images. Our static reconstructions of Sgr A* can be clustered into four representative morphologies that correspond to ring images with three different azimuthal brightness distributions and a small cluster that contains diverse nonring morphologies. Based on our extensive analysis of the effects of sparse (u,v)-coverage, source variability, and interstellar scattering, as well as studies of simulated visibility data, we conclude that the Event Horizon Telescope Sgr A* data show compelling evidence for an image that is dominated by a bright ring of emission with a ring diameter of ∼50 μas, consistent with the expected “shadow” of a 4 × 10$^{6}$ M $_{⊙}$ black hole in the Galactic center located at a distance of 8 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗