Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Design predictions for noise control in the cryogenic National Transonic Facility

Noise control in the National Transonic Facility - a cryogenic wind tunnel - has been examined in terms of acoustical design criteria, drive-fan noise and exhaust system noise. A duct lining with two layers of perforated sheeting and a gas-filled honeycomb core was selected for attenuating drive-fan noise. With the exception of attenuation peaks, attenuation of the lining was found to experimentally agree with predicted values at 20 C air temperatures. Exhaust system noise will be attenuated with a large muffler used in conjunction with a 6.1-m high acoustical enclosure. Fan noise from the fan-ejector system will be attenuated by fan silencers and the acoustic enclosure.

Lassiter, W. S.↗

Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in terms of the noise power at the peak height and +/−1.2% in terms of the spatial frequency at the peak height. The magnitudes of the noise measured for 12 different combinations the phantom size, tube current, and reconstruction kernel for the simulated and real low-dose images were very similar, with differences of 0.1 to 4.7%. Thep value for a statistical testing of the difference in the noise magnitude ranged from 0.99 to 0.11, showing that there was no difference statistically between the noise magnitudes of the real and simulated low-dose images using our method. The strength and pattern of the streak noise in an anthropomorphic phantom was also consistent with expectations. Conclusions: A novel reduced-dose CT simulation technique was developed which uses only CT images while not requiring raw sinogram data. Our method can provide realistic simulation results under reduced-dose conditions both in terms of the noise magnitude and the textual appearance. This technique has the potential to promote clinical research for patient dose reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Active noise canceling system for mechanically cooled germanium radiation detectors

A microphonics noise cancellation system and method for improving the energy resolution for mechanically cooled high-purity Germanium (HPGe) detector systems. A classical adaptive noise canceling digital processing system using an adaptive predictor is used in an MCA to attenuate the microphonics noise source making the system more deployable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(55)Fe X-ray Response of HgCdTe NIR Detector Arrays

Conversion gain is a fundamental parameter in detector characteristics that is used to measure many identifying detector properties, including read noise, dark current, and quantum efficiency (QE). Charge coupling effects, such as inter-pixel capacitance, attenuate photon shot noise and result in an overestimation of of conversion gain when implementing the photon transfer technique. The (55)Fe X-ray technique is a direct and simple method by which to measure the conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by a single X-ray photon. Here we present the calibrated pair production energy for 1.7 micron HgCdTe infrared detectors.

Fox, Ori↗

Signal-to-noise enhancement in ground-based intensity observations of solar p modes

Intensity observations of solar p modes are needed to form a complete picture of wave propagation in the photosphere. Ground-based intensity observations are severely hampered by terrestrial atmospheric noise. Partial cancellation of the noise power can be achieved if two spectra having disparate signal-to- noise ratios, and based on time series acquired simultaneously at the same site, are combined. A method of combining the spectra is suggested in which one amplitude is scaled and subtracted from the other. The result is squared yielding a positive-definite power density. To test the method, the intensity of light scattered by the Earth's atmnosphere was recorded at fifteen- second intervals in two narrow bands centered on 0.5 microns and 1.6 microns. When the two resulting spectra were combined, the noise power was attenuated by a factor of 2.7. The scale factor was varied about its optimum value, revealing that noise peaks have a different siganture than signal peaks, and opening up the possibility of a new tool in discrimination against noise peaks. Maxima at symmetry-allowed frequencies and minima at symmetry- forbidden frequencies indicate that the possibility that these results are obtained by chance is only 6.1 x 10(exp -4). The positions of these maxima and minima also support the solar-cycle dependent frequency shifts found by Palle, Regulo, and Roca Cortes.

Germain, Marvin E.↗

Assessment of Bulk Absorber Properties for Multi-Layer Perforates in Porous Honeycomb Liners

CONTINUING progress in materials technology provides potential for improved acoustic liners for attenuating broadband fan noise emissions from aircraft engine nacelles. Conventional liners (local-reacting perforate-over-honeycomb structures) provide significant narrow-band attenuation, but limited attenuation over wide bandwidths. Two approaches for increasing attenuation bandwidth are to (1) replace the honeycomb structure with bulk material, or (2) cascade multiple layers of perforate/honeycomb structures. Usage of the first approach is limited because of mechanical and maintenance reasons, while multi-layer liners are limited to about three layers because of their additional mechanical complexity, depth and weight. The current research concerns a novel approach reported by the University of Cincinnati, in which a single-layer conventional liner is converted into an extended-reaction, broadband absorber by making the honeycomb core structure porous. This modified single-layer liner requires no increase in depth and weight, and minimal increase in mechanical complexity. Langley has initiated research to identify potential benefits of liner structures with porous cell walls. This research has two complementary goals: (1) develop and validate experimental techniques for treating multi-layer perforates (representative of the internal cells of a liner with porous cell walls) as 1-D bulk materials, and (2) develop analytical approaches to validate this bulk material assumption. If successful, the resultant model can then be used to design optimized porous honeycomb liners. The feasibility of treating an N-layer perforate system (N porous plates separated by uniform air gaps) as a one-dimensional bulk absorber is assessed using the Two-Thickness Method (TTM), which is commonly used to educe bulk material intrinsic acoustic parameters. Tests are conducted with discrete tone and random noise sources, over an SPL range sufficient to determine the nonlinearity of the test specimens, for test specimens consisting of 5, 10 and 15% porous plates. Measured impedances for two liner thicknesses (e.g., 12 and 24 layers) are used as input to the TTM to determine the characteristic impedance and propagation constant that characterize these liners as bulk absorbers. These parameters are then used to calculate the predicted impedance of liners with different thicknesses (e.g., 36 layers), and a comparison of predicted and measured impedances for these other thicknesses is used to determine the efficacy of this approach. Finally, an independent method is used to educe the propagation constant for a single representative sample, and excellent comparison between the results for this method and those for the TTM provides increased confidence in the results achieved with the TTM. In general, the results demonstrate these multi-layer perforates can be acceptably treated as bulk absorbers.

Jones, Michael G.↗

Polarization radar measurements in rain at 5 and 9 GHz

Potential techniques for measuring rainfall rate R and rainwater content W at 9 and 5 GHz are explored. An investigation is made of a previous technique to use the polarization propagation differential phase shift with increasing distance from the radar Phi(H-V) to estimate and remove the effects of specific and polarization differential attenuation from Z(H) and Z(DR), respectively. It is shown that in rain this technique is sensitive to variations in the drop-size distribution. It is confirmed that Phi(H-V) can be used to extend the distance over which useful measurements of Z(H) and Z(DR) can be obtained. While residual errors introduced by attenuation and the 'noise' from the correction scheme itself eclipse the potential of many possible techniques for quantitative rainfall measurements at these frequencies, the attenuation recovery scheme is argued to be adequate for obtaining useful polarization microphysical measurements, particularly above the melting level, even after encounters with rain.

Jameson, A. R.↗

Attenuation of upstream-generated low frequency noise by gas turbines

The acoustic transfer functions of low frequency (below 3500 Hz) noise through aircraft turbines were investigated. Model test results were compared with theoretical predictions in order to assess the validity of the theory. Component tests were conducted on both high pressure and low pressure model turbines. The influence of inlet temperature and turbine speed attenuation was evaluated, while the effects of turbine pressure ratio, blade-row choking, and additional downstream stages were determined. Preliminary identification of pertinent aeroacoustic correlating parameters was made.

Doyle, V. L.↗

Aircraft interior noise reduction by alternate resonance tuning

The focus is on a noise control method which considers aircraft fuselages lined with panels alternately tuned to frequencies above and below the frequency that must be attenuated. An interior noise reduction called alternate resonance tuning (ART) is described both theoretically and experimentally. Problems dealing with tuning single paneled wall structures for optimum noise reduction using the ART methodology are presented, and three theoretical problems are analyzed. The first analysis is a three dimensional, full acoustic solution for tuning a panel wall composed of repeating sections with four different panel tunings within that section, where the panels are modeled as idealized spring-mass-damper systems. The second analysis is a two dimensional, full acoustic solution for a panel geometry influenced by the effect of a propagating external pressure field such as that which might be associated with propeller passage by a fuselage. To reduce the analysis complexity, idealized spring-mass-damper panels are again employed. The final theoretical analysis presents the general four panel problem with real panel sections, where the effect of higher structural modes is discussed. Results from an experimental program highlight real applications of the ART concept and show the effectiveness of the tuning on real structures.

Gottwald, James A.↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

Validation of a Digital Noise Power Integration Technique for Radiometric Clear Sky Attenuation Estimation at Q-band

This paper presents the validation of a digital signal processing technique that can be used to estimate radiometric sky noise, and hence, atmospheric absorption, within existing digital receivers at little/no additional cost. To demonstrate this, a receiver was constructed that simultaneously records the beacon signal power from the ALPHASAT Aldo Paraboni technology demonstration payload, as well as the integrated noise power in the adjacent band. Calibration from the digital radiometer is performed using tip-curve calibration procedures. Atmospheric fading is then obtained by observing the beacon as well as the radiometric signals. This enables the comparison of fading obtained by the two techniques and provides a means to calibrate the received beacon power level to obtain total atmospheric attenuation. It is shown that for low levels of fading, up to a few dB, the two techniques provide good agreement. This approach can therefore provide a low-cost option for geostationary mmwave satellite channel measurements in the low fading regime, which can be useful in the design and operation of the feeder links in emerging satcom systems.

radiometer↗

Effect of treated length on performance of full scale turbofan inlet noise suppressors

Two inlet noise suppressors containing wall treatment plus three treated rings were tested on a fan in an outdoor noise facility. Sound power attenuations were measured for three treated lengths of each suppressor. The noise reduction from the segment of liner closest to the fan, which contained a segment of wall treatment downstream of the splitter rings, was greater than the reduction from either of the other segments. The decibel attenuations of the ringed liner segments were linear with liner length as predicted by theory. The acoustic attenuation of the wall treatment was considerably greater than expected for available theory. This inordinate effectiveness of the wall treatment strongly suggests the possibility of using no-ring inlet suppressors when the required noise reduction is moderate. The decibel attenuations were higher than predicted above 2000 hertz, and the two suppressors behaved similarly despite the prediction of different behavior.

Dittmar, J. H.↗

The (55)Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

The accurate determination of a detector's fundamental parameters, including read noise, dark current, and QE, relies on a proper measurement of a detector's conversion gain (e- ADU(exp -1)). Charge coupling effects, such as interpixel capacitance, attenuate photon shot noise and result in an overestimation of conversion gain when implementing the photon transfer technique. An approach involving (55)Fe X-rays provides a potentially straightforward measurement of conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by the X-ray. This technique is already preferred within the CCD community, as the pair production energy for silicon is well established. In contrast, to date the pair production energy is unknown for HgCdTe, a material commonly used for near-infrared detectors. In this paper, we derive a preliminary calibration of the (55)Fe X-ray energy response of HgCdTe using 8 HST WFC3 1.7 micrometers flight grade detectors. Our conversion of the X-ray intensities from counts into electrons implements a technique that restores the 'true' gain via classical propagation of errors. For these detectors, our analysis yields preliminary results of good statistical precision: each Ka event generates 1849 +/- 46 electrons, which corresponds to a pair production energy of 3.21+/-f 0.08 eV. We are continuing to assess potential systematic effects to further refine the accuracy of this result.

Fox, Ori↗

Perceived magnitude of two-tone-noise complexes - Loudness, annoyance, and noisiness

An investigation of the perceived effects of tonal components was undertaken to establish a broader data base for quantification and prediction of annoyance of sounds containing added tones. The current study was concerned with two-tone-noise complexes. The stimuli were tone pairs added to a low-pass noise that was attenuated by 5 dB/oct above 600 Hz. Overall perceived magnitude is shown to be a function of the frequency separation (Delta F) between the tonal components, tone-to-noise ratio, and the overall SPL of the noise-tone complex. Results obtained with two tones are compared to those obtained in an earlier study by Hellman (1984) with single tones. The observed effects appear relevant to the rules governing loudness summation across frequency, to measurements of psychoacoustic consonance and roughness, and to the issue of mutual masking among the component stimuli. The implications of the findings in relation to proposed tone-correction procedures are also discussed.

Hellman, R. P.↗

Depth profile characterization with noncollinear beam mixing

Noncollinear beam mixing is an ultrasonic approach to quantify elastic nonlinearity within a subsurface volume of material. The technique requires interaction between two beams of specific frequency, angle, and vibration mode to generate a third beam propagating from the intersection volume. The subsurface depth to interaction zone is controlled by changing the separation distance between the two input transducers, and the amplitude of the third generated beam is proportional to the elastic nonlinearity within the interaction zone. Therefore, depth profiling is possible if a suitable parameter is established to normalize the detected signal independent of propagation distances and input amplitudes. This foundational effort has been conducted toward developing such a parameter for depth profile measurements in homogeneous aluminum that includes corrective terms for attenuation, beam overlap noise, beam spread, and input amplitudes. Experimental and analytical results are provided, and suggested applications and improvements are discussed toward characterizing subsurface material property profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of thickness on airfoil surface noise

Noise emission from very small chord and very large chord airfoils was measured with eleven 0.63 cm microphones placed along a horizontal semicircle (4.57 m radius) that was centered at the leading edge of the test airfoil. The noise signals were analyzed by an automated spectrum analyzer which yielded 1/3-octave band sound pressure level spectra for each microphone, and the data were corrected to remove the effects of atmospheric attenuation and jet noise. It is found that the effect of thickness is large and must be accounted for in any fundamental airfoil noise theory that attempts to describe the noise emitted from real airfoils. Incident mean velocity gradients and compressibility must also be taken into account. The effect of thickness increases with frequency, with thick airfoils being quieter than thin ones.

Olsen, W.↗

DUKE PRO STI TEST at 9965 - RANGE 1 (IMPACT NOISE). Survey Profile Report

Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection. Based on the area impact noise sample results, the attenuation provided by the MFCP was protective for mitigating noise to levels below the ACGIH TLV of 140 dBC. The results also validated the scaled distance equation in an open-air environment as the results at K635 (864 feet) were below 140 dBC.

54 ENVIRONMENTAL SCIENCES↗