Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NASA Center ARC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Growth hormone, IGF-I, and exercise effects on non-weight-bearing fast muscles of hypophysectomized rats

The effects of growth hormone (GH) or insulin-like growth factor I (IGF-I) with or without exercise (ladder climbing) in countering the effects of unweighting on fast muscles of hypophysectomized rats during 10 days of hindlimb suspension were determined. Compared with untreated suspended rats, muscle weights were 16-29% larger in GH-treated and 5-15% larger in IGF-I-treated suspended rats. Exercise alone had no effect on muscle weights. Compared with ambulatory control, the medial gastrocnemius weight in suspended, exercised rats was larger after GH treatment and maintained with IGF-I treatment. The combination of GH or IGF-I plus exercise in suspended rats resulted in an increase in size of each predominant fiber type, i.e., types I, I + IIa and IIa + IIx, in the medial gastrocnemius compared with untreated suspended rats. Normal ambulation or exercise during suspension increased the proportion of fibers expressing embryonic myosin heavy chain in hypophysectomized rats. The phenotype of the medial gastrocnemius was minimally affected by GH, IGF-I, and/or exercise. These results show that there is an IGF-I, as well as a GH, and exercise interactive effect in maintaining medial gastrocnemius fiber size in suspended hypophysectomized rats.

NASA Center ARC↗

Interactions between integrin receptors and fibronectin are required for calvarial osteoblast differentiation in vitro

We previously showed that anti-fibronectin antibodies or soluble fibronectin fragments containing the central cell-binding domain inhibit formation of mineralized nodules by fetal calvarial osteoblasts in vitro. These findings suggest a critical role for fibronectin in osteoblast differentiation and morphogenesis. In this study we tested the hypothesis that fibronectin's effects on osteogenesis are mediated via direct interactions with integrin receptors for fibronectin on osteoblasts. Immunocytochemical analysis identified the integrin fibronectin receptor alpha5ss1 in fetal rat calvarial tissue and in cultured osteoblasts at all stages of differentiation. Three other integrins, alpha3ss1, alpha8ss1 and alphavss3, which can bind fibronectin, as well as other matrix components, were also identified in tissue and at all stages of cell culture. Immunoprecipitation data showed that alpha5ss1 levels are constant throughout osteoblast differentiation whereas levels of alpha3ss1 and alpha8ss1 decline in mature mineralized cultures. To determine whether integrin fibronectin receptors are required for osteoblast formation of mineralized nodules, we examined the extent of nodule formation in the presence and absence of function-perturbing anti-integrin antibodies. The antibodies were present continuously in cultures beginning at confluence (day 3), and nodule formation was measured at days 10 and 20. An anti-alpha5 integrin subunit antibody reduced nodule formation to less than 5% of control values at both time points. Inhibition of nodule formation was reversible and did not affect cell attachment and viability. Function-perturbing antibodies against alpha3ss1 and alpha8ss1 also reduced nodule formation, to less than 20% of control values. In contrast, function-perturbing antibodies to alphavss3 and alphavss5 did not affect nodule formation, indicating that the inhibitions noted were indeed specific. To determine the effect of antibody treatment on gene expression, steady-state mRNA expression was examined and found to be suppressed for osteoblast markers alkaline phosphatase and osteocalcin. Together, these results indicate that direct osteoblast interactions with the extracellular matrix are mediated by a select group of integrin receptors that includes alpha5ss1, alpha3ss1 and alpha8ss1. We further conclude that the specific alpha5ss1 fibronectin receptor mediates critical interactions between osteoblasts and fibronectin required for both bone morphogenesis and osteoblast differentiation.

NASA Center ARC↗

Forearm muscle oxygenation decreases with low levels of voluntary contraction

The purpose of our investigation was to determine if the near infrared spectroscopy technique was sensitive to changes in tissue oxygenation at low levels of isometric contraction in the extensor carpi radialis brevis muscle. Nine subjects were seated with the right arm abducted to 45 degrees, elbow flexed to 85 degrees, forearm pronated 45 degrees, and wrist and forearm supported on an armrest throughout the protocol. Altered tissue oxygenation was measured noninvasively with near infrared spectroscopy. The near infrared spectroscopy probe was placed over the extensor carpi radialis brevis of the subject's right forearm and secured with an elastic wrap. After 1 minute of baseline measurements taken with the muscle relaxed, four different loads were applied just proximal to the metacarpophalangeal joint such that the subjects isometrically contracted the extensor carpi radialis brevis at 5, 10, 15, and 50% of the maximum voluntary contraction for 1 minute each. A 3-minute recovery period followed each level of contraction. At the end of the protocol, with the probe still in place, a value for ischemic tissue oxygenation was obtained for each subject. This value was considered the physiological zero and hence 0% tissue oxygenation. Mean tissue oxygenation (+/-SE) decreased from resting baseline (100% tissue oxygenation) to 89 +/- 4, 81 +/- 8, 78 +/- 8, and 47 +/- 8% at 5, 10, 15, and 50% of the maximum voluntary contraction, respectively. Tissue oxygenation levels at 10, 15, and 50% of the maximum voluntary contraction were significantly lower (p < 0.05) than the baseline value. Our results indicate that tissue oxygenation significantly decreases during brief, low levels of static muscle contraction and that near infrared spectroscopy is a sensitive technique for detecting deoxygenation noninvasively at low levels of forearm muscle contraction. Our findings have important implications in occupational medicine because oxygen depletion induced by low levels of muscle contraction may be directly linked to muscle fatigue.

NASA Center ARC↗

Image discrimination models predict detection in fixed but not random noise

By means of a two-interval forced-choice procedure, contrast detection thresholds for an aircraft positioned on a simulated airport runway scene were measured with fixed and random white-noise masks. The term fixed noise refers to a constant, or unchanging, noise pattern for each stimulus presentation. The random noise was either the same or different in the two intervals. Contrary to simple image discrimination model predictions, the same random noise condition produced greater masking than the fixed noise. This suggests that observers seem unable to hold a new noisy image for comparison. Also, performance appeared limited by internal process variability rather than by external noise variability, since similar masking was obtained for both random noise types.

NASA Center ARC↗

Misperceptions of angular velocities influence the perception of rigidity in the kinetic depth effect

Accuracy in discriminating rigid from nonrigid motion was investigated for orthographic projections of three-dimension rotating objects. In 3 experiments the hypothesis that magnitudes of angular velocity are misperceived in the kinetic depth effect was tested, and in 4 other experiments the hypothesis that misperceiving angular velocities leads to misperceiving rigidity was tested. The principal findings were (a) the magnitude of perceived angular velocity is derived heuristically as a function of a property of the first-order optic flow called deformation and (b) perceptual performance in discriminating rigid from nonrigid motion is accurate in cases when the variability of the deformations of the individual triplets of points of the stimulus displays favors this interpretation and not accurate in other cases.

NASA Center ARC↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Effects of static fingertip loading on carpal tunnel pressure

The purpose of this study was to explore the relationship between carpal tunnel pressure and fingertip force during a simple pressing task. Carpal tunnel pressure was measured in 15 healthy volunteers by means of a saline-filled catheter inserted percutaneously into the carpal tunnel of the nondominant hand. The subjects pressed on a load cell with the tip of the index finger and with 0, 6, 9, and 12 N of force. The task was repeated in 10 wrist postures: neutral; 10 and 20 degrees of ulnar deviation; 10 degrees of radial deviation; and 15, 30, and 45 degrees of both flexion and extension. Fingertip loading significantly increased carpal tunnel pressure for all wrist angles (p = 0.0001). Post hoc analyses identified significant increase (p < 0.05) in carpal tunnel pressure between unloaded (0 N) and all loaded conditions, as well as between the 6 and 12 N load conditions. This study demonstrates that the process whereby fingertip loading elevates carpal tunnel pressure is independent of wrist posture and that relatively small fingertip loads have a large effect on carpal tunnel pressure. It also reveals the response characteristics of carpal tunnel pressure to fingertip loading, which is one step in understanding the relationship between sustained grip and pinch activities and the aggravation or development of median neuropathy at the wrist.

NASA Center ARC↗

Contrast affects flicker and speed perception differently

We have previously shown that contrast affects speed perception, with lower-contrast, drifting gratings perceived as moving slower. In a recent study, we examined the implications of this result on models of speed perception that use the amplitude of the response of linear spatio-temporal filters to determine speed. In this study, we investigate whether the contrast dependence of speed can be understood within the context of models in which speed estimation is made using the temporal frequency of the response of linear spatio-temporal filters. We measured the effect of contrast on flicker perception and found that contrast manipulations produce opposite effects on perceived drift rate and perceived flicker rate, i.e., reducing contrast increases the apparent temporal frequency of counterphase modulated gratings. This finding argues that, if a temporal frequency-based algorithm underlies speed perception, either flicker and speed perception must not be based on the output of the same mechanism or contrast effects on perceived spatial frequency reconcile the disparate effects observed for perceived temporal frequency and speed.

NASA Center ARC↗

Prediction of human gait parameters from temporal measures of foot-ground contact

Investigation of the influence of human physical activity on bone functional adaptation requires long-term histories of gait-related ground reaction force (GRF). Towards a simpler portable GRF measurement, we hypothesized that: 1) the reciprocal of foot-ground contact time (1/tc); or 2) the reciprocal of stride-period-normalized contact time (T/tc) predict peak vertical and horizontal GRF, loading rates, and horizontal speed during gait. GRF data were collected from 24 subjects while they walked and ran at a variety of speeds. Linear regression and ANCOVA determined the dependence of gait parameters on 1/tc and T/tc, and prediction SE. All parameters were significantly correlated to 1/tc and T/tc. The closest pooled relationship existed between peak running vertical GRF and T/tc (r2 = 0.896; SE = 3.6%) and improved with subject-specific regression (r2 = 0.970; SE = 2.2%). We conclude that temporal measures can predict force parameters of gait and may represent an alternative to direct GRF measurements for determining daily histories of habitual lower limb loading quantities necessary to quantify a bone remodeling stimulus.

NASA Center ARC↗

Morphological evidence for local microcircuits in rat vestibular maculae

Previous studies suggested that intramacular, unmyelinated segments of vestibular afferent nerve fibers and their large afferent endings (calyces) on type I hair cells branch. Many of the branches (processes) contain vesicles and are presynaptic to type II hair cells, other processes, intramacular nerve fibers, and calyces. This study used serial section transmission electron microscopy and three-dimensional reconstruction methods to document the origins and distributions of presynaptic processes of afferents in the medial part of the adult rat utricular macula. The ultrastructural research focused on presynaptic processes whose origin and termination could be observed in a single micrograph. Results showed that calyces had 1) vesiculated, spine-like processes that invaginated type I cells and 2) other, elongate processes that ended on type II cells pre- as well as postsynaptically. Intramacular, unmyelinated segments of afferent nerve fibers gave origin to branches that were presynaptic to type II cells, calyces, calyceal processes, and other nerve fibers in the macula. Synapses with type II cells occurred opposite subsynaptic cisternae (C synapses); all other synapses were asymmetric. Vesicles were pleomorphic but were differentially distributed according to process origin. Small, clear-centered vesicles, approximately 40-60 nm in diameter, predominated in processes originating from afferent nerve fibers and basal parts of calyces. Larger vesicles approximately 70-120 nm in diameter having approximately 40-80 nm electron-opaque cores were dominant in processes originating from the necks of calyces. Results are interpreted to indicate the existence of a complex system of intrinsic feedforward (postsynaptic)-feedback (presynaptic) connections in a network of direct and local microcircuits. The morphological findings support the concept that maculae dynamically preprocess linear acceleratory information before its transmission to the central nervous system.

NASA Center ARC↗

Exercise thermoregulation with bed rest, confinement, and immersion deconditioning

Altered thermoregulation following exposure to prolonged (12-14 days) of bed rest and 6 hr of head-down thermoneutral water immersion in humans, and cage confinement (8 weeks) in male, mongrel dogs resulted in occasional increased core temperature (Tcore) at rest, but consistent "excessive" increase in Tcore during submaximal exercise. This excessive increase in Tcore in nonexercising and exercising subjects was independent of the mode (isometric or isotonic) of exercise training during bed rest, and was associated with the consistent hypovolemia in men but not in women taking estrogen supplementation (1.25 mg premarin/ day) which restored plasma volume during bed rest to ambulatory control levels. Post-bed rest exercise sweating (evaporative heat loss) was unchanged or higher than control levels; however, calculated tissue heat conductance was significantly lower in men, and forearm venoconstriction was greater (venous volume was reduced) in women during exercise after bed rest. Because sweating appeared proportional to the increased level of Tcore, these findings suggest that one major factor for the excessive hyperthermia is decreased core to periphery heat conduction. Exercising dogs respond like humans with excessive increase in both rectal (Tre) and exercising muscle temperatures (Tmu) after confinement and, after eight weeks of exercise training on a treadmill following confinement, they had an attenuated rate of increase of Tre even below ambulatory control levels. Intravenous infusion of glucose also attenuated not only the rise in Tre during exercise in normal dogs, but also the excessive rise in Tre and exercising Tmu after confinement. Oral glucose also appeared to reduce the rate of increase in excessive Tre in men after immersion deconditioning. There was a greater rate of rise in Tcore in two cosmonauts during supine submaximal exercise (65% VO2 max) on the fifth recovery day after the 115-day Mir 18 mission. Thus, the excessive rise in core temperature after deconditioning appears to be caused by decreased peripheral vasodilation in humans. Factors related to glucose metabolism may influence this mechanism.

NASA Program Space Physiology and Countermeasures↗

Human heading estimation during visually simulated curvilinear motion

Recent studies have suggested that humans cannot estimate their direction of forward translation (heading) from the resulting retinal motion (flow field) alone when rotation rates are higher than approximately 1 deg/sec. It has been argued that either oculomotor or static depth cues are necessary to disambiguate the rotational and translational components of the flow field and, thus, to support accurate heading estimation. We have re-examined this issue using visually simulated motion along a curved path towards a layout of random points as the stimulus. Our data show that, in this curvilinear motion paradigm, five of six observers could estimate their heading relatively accurately and precisely (error and uncertainty < approximately 4 deg), even for rotation rates as high as 16 deg/sec, without the benefit of either oculomotor or static depth cues signaling rotation rate. Such performance is inconsistent with models of human self-motion estimation that require rotation information from sources other than the flow field to cancel the rotational flow.

NASA Center ARC↗

Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

NASA Discipline Number 26-10↗

Hemodynamic and thermal responses to head and neck cooling in men and women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.

NASA Center ARC↗

The barberplaid illusion: plaid motion is biased by elongated apertures

The perceived direction of motion of plaids windowed by elongated spatial Gaussians is biased toward the window's long axis. The bias increases as the relative angle between the plaid motion and the long axis of the window increases, peaks at a relative angle of approximately 45 deg, and then decreases. The bias increases as the window is made narrower (at fixed height) and decreases as the component spatial frequency increases (at fixed aperture size). We examine several models of human motion processing (cross-correlation, motion-energy, intersection-of-constraints, and vector-sum), and show that none of these standard models can predict our data. We conclude that spatial integration of motion signals plays a crucial role in plaid motion perception and that current models must be explicitly expanded to include such spatial interactions.

NASA Center ARC↗

Musculoskeletal adaptations to weightlessness and development of effective countermeasures

A Research Roundtable, organized by the American College of Sports Medicine with sponsorship from the National Aeronautics and Space Administration, met in November 1995 to define research strategies for effective exercise countermeasures to weightlessness. Exercise was considered both independently of, and in conjunction with, other therapeutic modalities (e.g., pharmacological nutritional, hormonal, and growth-related factors) that could prevent or minimize the structural and functional deficits involving skeletal muscle and bone in response to chronic exposure to weightlessness, as well as return to Earth baseline function if a degree of loss is inevitable. Musculoskeletal deficits and countermeasures are described with respect to: 1) muscle and connective tissue atrophy and localized bone loss, 2) reductions in motor performance, 3) potential proneness to injury of hard and soft tissues, and 4) probable interaction between muscle atrophy and cardiovascular alterations that contribute to the postural hypotension observed immediately upon return from space flight. In spite of a variety of countermeasure protocols utilized previously involving largely endurance types of exercise, there is presently no activity-specific countermeasure(s) that adequately prevent or reduce musculoskeletal deficiencies. It seems apparent that countermeasure exercises that have a greater resistance element, as compared to endurance activities, may prove beneficial to the musculoskeletal system. Many questions remain for scientific investigation to identify efficacious countermeasure protocols, which will be imperative with the emerging era of long-term space flight.

Non-NASA Center↗

Physiological adaptations and countermeasures associated with long-duration spaceflights

Since 1961, there have been more than 165 flights involving several hundred individuals who have remained in a space environment from 15 min to more than a year. In addition, plans exist for humans to explore, colonize, and remain in microgravity for 1000 d or more. This symposium will address the current state of knowledge in select aspects associated with the cardiovascular, fluid and electrolytes, musculoskeletal, and the neuroendocrine and immune systems. The authors will focus on responses, mechanisms, and the appropriate countermeasures to minimize or prevent the physiological and biochemical consequences of a microgravity environment. Since exercise is frequently cited as a generic countermeasure, this topic will be covered in greater detail. Models for simulated microgravity conditions will be discussed in subsequent manuscripts, as will future directions for ground-based research.

NASA Center ARC↗