Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

Multiplex Navigation of Global Regulatory Networks (MINR) in yeast for Improved Ethanol Tolerance and Production

Multiplex navigation of global regulatory networks (MINR) is an approach for combinatorially reprogramming gene expression to manipulate complex phenotypes. We designed, constructed, and mapped MINR libraries containing 43,020 specific mutations in 25 regulatory genes expected to perturb the yeast regulatory network. We selected growth competition experiments for library mutants conferring increased ethanol and/or glucose tolerance. We identified specific mutants that not only possessed improved ethanol and/or glucose tolerance but also produced ethanol at concentrations up to 2-fold higher than those produced by the wild-type strain. We further determined that mutations increasing ethanol tolerance were transferable to a diploid industrial yeast strain. The facile construction and mapping of 43,020 designer regulatory mutations provide a roadmap for how to access and engineer complex phenotypes in future synthetic biology and broader efforts.

09 BIOMASS FUELS↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo

Arrays of electrodes for recording and stimulating the brain are used throughout clinical medicine and basic neuroscience research, yet are unable to sample large areas of the brain while maintaining high spatial resolution because of the need to individually wire each passive sensor at the electrode-tissue interface. To overcome this constraint, we developed new devices that integrate ultrathin and flexible silicon nanomembrane transistors into the electrode array, enabling new dense arrays of thousands of amplified and multiplexed sensors that are connected using fewer wires. We used this system to record spatial properties of cat brain activity in vivo, including sleep spindles, single-trial visual evoked responses and electrographic seizures. We found that seizures may manifest as recurrent spiral waves that propagate in the neocortex. As a result, the developments reported here herald a new generation of diagnostic and therapeutic brain-machine interface devices.

high spatial resolution↗

Multiplexed CRISPR-Cas9-Based Genome Editing of Rhodosporidium toruloides

Microbial production of biofuels and bioproducts offers a sustainable and economic alternative to petroleum-based fuels and chemicals. The basidiomycete yeast Rhodosporidium toruloides is a promising platform organism for generating bioproducts due to its ability to consume a broad spectrum of carbon sources (including those derived from lignocellulosic biomass) and to naturally accumulate high levels of lipids and carotenoids, two biosynthetic pathways that can be leveraged to produce a wide range of bioproducts. While R. toruloides has great potential, it has a more limited set of tools for genetic engineering relative to more advanced yeast platform organisms such as Yarrowia lipolytica and Saccharomyces cerevisiae. Significant advancements in the past few years have bolstered R. toruloides ’ engineering capacity. Here we expand this capacity by demonstrating the first use of CRISPR-Cas9-based gene disruption in R. toruloides . Transforming a Cas9 expression cassette harboring nourseothricin resistance and selecting transformants on this antibiotic resulted in strains of R. toruloides exhibiting successful targeted disruption of the native URA3 gene. While editing efficiencies were initially low (0.002%), optimization of the cassette increased efficiencies 364-fold (to 0.6%). Applying these optimized design conditions enabled disruption of another native gene involved in carotenoid biosynthesis, CAR2 , with much greater success; editing efficiencies of CAR2 deletion reached roughly 50%. Finally, we demonstrated efficient multiplexed genome editing by disrupting both CAR2 and URA3 in a single transformation. Altogether, our results provide a framework for applying CRISPR-Cas9 to R. toruloides that will facilitate rapid and high-throughput genome engineering in this industrially relevant organism.

59 BASIC BIOLOGICAL SCIENCES↗

Simulate_PCR for amplicon prediction and annotation from multiplex, degenerate primers and probes

Background: Pairing up primers to amplify desired targets and avoid undesired cross reactions can be a combinatorial challenge. Effective prediction of specificity and inclusivity from multiplexed primers and TaqMan®/ Luminex® probes is a critical step in PCR design. Results: Code is described to identify all primer and probe combinations from a list of unpaired, unordered candidates that should produce a product. It predicts and extracts all amplicon sequences in a large sequence database from a list of primers and probes, allowing degenerate bases and user-specified levels of primer-target mismatch tolerance. Amplicons hit by TaqMan®/Luminex® probes are indicated, and products may be annotated with gene information from NCBI. Fragment length distributions are calculated to predict electrophoretic gel banding patterns. Conclusions: Simulate_PCR is the only freely available software that can be run from the command line for high throughput applications which can calculate all products from large lists of primers and probes compared to a large sequence database such as nt. It requires no prior knowledge of how primers should be paired. Degenerate bases are allowed and entire amplicon sequences are extracted and annotated with gene information. Examples are provided for sets of TaqMan®/Luminex® PCR signatures predicted to amplify all HIV-1 genomes, all Coronaviridae genomes, and a group of antibiotic resistance genes. The software is a command line perl script freely available as open source.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

PARA: A New Platform for the Rapid Assembly of gRNA Arrays for Multiplexed CRISPR Technologies

Multiplexed CRISPR technologies have great potential for pathway engineering and genome editing. However, their applications are constrained by complex, laborious and time-consuming cloning steps. In this research, we developed a novel method, PARA, which allows for the one-step assembly of multiple guide RNAs (gRNAs) into a CRISPR vector with up to 18 gRNAs. Here, we demonstrate that PARA is capable of the efficient assembly of transfer RNA/Csy4/ribozyme-based gRNA arrays. To aid in this process and to streamline vector construction, we developed a user-friendly PARAweb tool for designing PCR primers and component DNA parts and simulating assembled gRNA arrays and vector sequences.

59 BASIC BIOLOGICAL SCIENCES↗

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗

Multiplex growth rate phenotyping of synthetic mutants in selection to engineer glucose and xylose co‐utilization in Escherichia coli

ABSTRACT Engineering the simultaneous consumption of glucose and xylose sugars is critical to enable the sustainable production of biofuels from lignocellulosic biomass. In most major industrial microorganisms glucose completely inhibits the uptake of xylose, limiting efficient sugar mixture conversion. In E . coli removal of the major glucose transporter PTS allows for glucose and xylose co‐consumption but only after prolonged adaptation, which is an effective process but hard to control and prone to co‐evolving undesired traits. Here we synthetically engineer mutants to target sugar co‐consumption properties; we subject a PTS − mutant to a short adaptive step and subsequently either delete or overexpress key genes previously suggested to affect sugar consumption. Screening the co‐consumption properties of these mutants individually is very laborious. We show we can evaluate sugar co‐consumption properties in parallel by culturing the mutants in selection and applying a novel approach that computes mutant growth rates in selection using chromosomal barcode counts obtained from Next‐Generation Sequencing. We validate this multiplex growth rate phenotyping approach with individual mutant pure cultures, identify new instances of mutants cross‐feeding on metabolic byproducts, and, importantly, find that the rates of glucose and xylose co‐consumption can be tuned by altering glucokinase expression in our PTS − background. Biotechnol. Bioeng. 2017;114: 885–893. © 2016 Wiley Periodicals, Inc.

Groot, Joost↗

Development of a Massive, Highly Multiplexible, Phonon-Mediated Particle Detector Using Kinetic Inductance Detectors

Here, we present a status update on the development of a phonon-mediated particle detector using kinetic inductance detector (KID). The design is intended for \(\mathscr {O}(1)\) kg substrate, using \(\mathscr {O}(10^{2})\) KIDs on a single readout line, to image the athermal phonon distribution at < 1 mm position resolution and \(\mathscr {O}(10)\) eV energy resolution. The design specification is set by the need to improve position reconstruction fidelity while maintaining low energy threshold for future rare-event searches such as for low-mass dark matter. Furthermore, we report on the design, which shows negligible crosstalk and > 95% inductor current uniformity, using the coplanar waveguide feedline, ground shield, and a new class of KIDs with symmetric coplanar stripline (sCPS) inductor. The multiplexing is designed upon the frequency-geometry relation we develop for the sCPS KIDs. We introduce the fabrications of the Nb RF assessment prototypes and the high phonon collection efficiency Al–Nb devices. We achieve \(\lesssim \) 0.07% frequency displacement on a 80-KID RF assessment prototype, and the result indicates that we may place more than 180 resonances in our 0.4 GHz readout band with minimal frequency misordering. The coupling quality factors are \(\sim \) 10 \(^{5}\) as designed. Finally, we update our work in progress in fabricating the \(\mathscr {O}(10^{2})\) KID, bi-material, \(\mathscr {O}(1)\) kg detectors, and the expected position and energy resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Suppression of four-wave mixing in a 22 × 10 Gbps dense wavelength division multiplexed system by linearly chirped fiber Bragg gratings

A scheme comprising two linearly chirped fiber Bragg gratings (LCFBGs) is proposed to suppress four-wave mixing (FWM) effects in a 22×10 Gbps dense wavelength division multiplexed (DWDM) system employing dispersion shifted fiber with 0.2 nm channel spacing. The FWM reduction in our proposed scheme has been studied by varying the input signal power per channel from − 2 to + 10 dBm. The parameters of LCFBGs are optimized to obtain a maximum quality factor for all 22 channels. The proposed method is effective even at high input power (10 dBm) and provides a simple, cost effective way to improve the transmission performance in DWDM system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimum shift keying based protection mode capable wavelength division multiplexed passive optical network optical overlay system

We explored the functioning of an optical overlay of multicast and unicast data streams on a survival wavelength division multiplexed passive optical network using intensity and minimum shift keying modulation for both single and multiuser. In optical line terminal, using a sinusoidal clock, optical subcarriers are generated not only to carry the multicast and unicast data streams simultaneously but also in case of fiber failure, protection mode is enabled to carry the data streams smoothly. Here, 10 Gbps downstream multicast in normal mode and unicast signals both in normal and protection mode are transmitted error-free through 30 km dispersion shifted fiber. In both the cases 10 Gbps upstream signal is modulated and sent back to the optical line terminal. For single user nearly similar power penalty is witnessed for downstream unicast as well as re-modulated upstream data in both the conditions and also when multicast data is disabled. The power penalties between single and multiuser for both the modes are found to be approximately 0.06, 0.42 and 0.7 dB for unicast MSK, multicast and upstream respectively.

36 MATERIALS SCIENCE↗

Trace double-component gas sensor in photoacoustic spectroscopy based on frequency division multiplexing

In this paper, we demonstrated a trace double-component gas detection system based on frequency division multiplexing using two-way distributed feedback laser diode (DFB-LD) as the excitation laser source. In the frequency response range of photoacoustic spectroscopy (PAS) cell, this detection system could detect the second harmonics of different frequencies f{sub 0} and f{sub 1}, which were excited by the gas absorption using the two wavelengths of DFB-LD at modulation frequencies f{sub 0}/2 and f{sub 1}/2. Unlike previous double-component gas sensor, these two DFB-LDs connected into the both ends of PAS cell without optical fiber coupler could effectively improve the excited light intensity and simplify the system structure. This feature allowed the trace detection of double-component gas of mixed-methane (CH{sub 4}) and water (H{sub 2}O) vapor with a low detection limits 11.055 ppm and 885 ppb, respectively. Additionally, the linear responses to the gas concentration were achieved 0.9986 and 0.9997, and it exhibited potentially as an effective detection system for complex gas component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing capacity of optical links using polarization multiplexing

5G mobile networks targets wireless connection capacity up to 10 Gb/s. For this purpose, we propose a method to considerably increase capacity. In this paper first, we show how to compensate the effects of polarization mode dispersion (PMD) in systems with double polarizations where PMD in such systems could cause fluctuations in optical transmission due to crosstalk and cross phase modulation. Second, we show how to enhance system capacity benefiting from polarization multiplexing (POL-MUX) technique which can provide double bandwidth efficiency. Based on the simulation results, we have achieved optimum system performance and we were able to reduce the PMD effect using pre- and post-compensation. We also have improved the POL-MUX technique using coherent detection in case of 16/64 QAM modulations. The results were achieved by implementing polarization controllers, polarization beam combiners and splitters, as well as polarization phase shifters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Profiling of bioactive lipids in different dendritic cell subsets using an improved multiplex quantitative LC-MS/MS method

Highlights: • We improved a LC-MS/MS method to measure many mediators simultaneously. • Conventional DCs produce inflammatory lipids (leukotrienes) preferentially. • RA-DCs produce PGI{sub 2}, PGE{sub 2}, and TXA{sub 2} preferentially. Lipids are an energy source and key components of the cell membrane; however, they are also bioactive mediators of physiological and pathophysiological phenomena. Quantification of bioactive lipids is not easy because they have diverse chemical properties and are present in trace amounts. Here, we improved a multiplex method of quantifying bioactive lipids, thereby enabling measurement of 90 compounds simultaneously. We then used this system to quantify bioactive lipids produced by two subsets of dendritic cells (DCs): all-trans retinoic acid-treated DCs (RA-DCs) (a type of tolerogenic DC (tDC)) and conventional DCs (cDCs). We found that cDCs produced inflammatory lipid mediators such as leukotrienes, whereas RA-DCs produced anti-inflammatory lipid mediators such as prostaglandin I{sub 2}. Consistent with this, cDCs expressed larger amounts of mRNA encoding 5-lipoxygenase and LTA{sub 4} hydrolase (both responsible for leukotriene biosynthesis) and RA-DCs produced larger amounts of mRNA encoding prostaglandin I{sub 2} synthase. Taken together, the results suggest that the method is useful for clarifying the roles of bioactive lipids during immune responses.

60 APPLIED LIFE SCIENCES↗