Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave frequencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Large microwave inductance of granular boron-doped diamond superconducting films

Boron-doped diamond granular thin films are known to exhibit superconductivity with an optimal critical temperature of T c =7.2 K. Here, we report the measured in-plane complex surface impedance of boron-doped diamond films in the microwave frequency range using a resonant technique. Experimentally measured inductance values are in good agreement with estimates obtained from the normal state sheet resistance of the material. Additionally, the magnetic penetration depth temperature dependence is consistent with that of a fully gapped s-wave superconductor. Boron-doped diamond films should find application where high kinetic inductance is needed, such as microwave kinetic inductance detectors and quantum impedance devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utilizing Brightness Temperature Histograms for Microwave Radiometer High Frequency (150-183 Ghz) Calibration

Spaceborne microwave radiometers with high frequency channels (150-183 GHz) are important for retrieving many geophysical parameters such as snowfall, ice water path, and atmospheric water vapor profiles. In order to obtain accurate retrievals from the brightness temperature measurements, the radiometers must be properly calibrated. Several methods have been developed to analyze the on-orbit calibration, including comparisons with radiative transfer models, comparisons with radiosonde profiles, and cross-calibration with similar radiometers. This paper introduces a new method to calibrate high frequency channels that utilizes TB histograms. This new method gives an independent approach that can be used by itself to analyze radiometer calibration or in conjunction with other methods to corroborate results.

microwave radiometry↗

Integrating magnons for quantum information

Magnons, the quanta of collective spin excitations in magnetically ordered materials, have distinct properties that make them uniquely appealing for quantum information applications. They can have ultra-small wavelengths down to the nanometer scale even at microwave frequencies. Here, they can provide coupling to a diverse set of other quantum excitations, and their inherently gyrotropic dynamics forms the basis for pronounced nonreciprocities. In this article, we discuss what the current research challenges are for integrating magnetic materials into quantum information systems and provide a perspective on how to address them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Measurements of a quantum bulk acoustic resonator using a superconducting qubit

Phonon modes at microwave frequencies can be cooled to their quantum ground state using conventional cryogenic refrigeration, providing a convenient way to study and manipulate quantum states at the single phonon level. Phonons are of particular interest because mechanical deformations can mediate interactions with a wide range of different quantum systems, including solid-state defects, superconducting qubits, and optical photons when using optomechanically active constructs. Phonons, thus, hold promise for quantum-focused applications as diverse as sensing, information processing, and communication. Here, we describe a piezoelectric quantum bulk acoustic resonator (QBAR) with a 4.88 GHz resonant frequency, which, at cryogenic temperatures, displays large electromechanical coupling strength combined with a high intrinsic mechanical quality factor, Q i ≈ 4.3 × 10 4 . Using a recently developed flip-chip technique, we couple this QBAR resonator to a superconducting qubit on a separate die and demonstrate the quantum control of the mechanics in the coupled system. Furthermore, this approach promises a facile and flexible experimental approach to quantum acoustics and hybrid quantum systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Recent developments and proposed schemes for trapped ion frequency standards

Ion traps are exciting candidates as future precision frequency sources. Recent developments demonstrate that mercury ion frequency standards are capable of a stability performance comparable to commercial cesium standards. There is, however, considerable room for improvement with regard to the signal to noise problem. The 40 GHz microwave frequency implies that a careful design should be implemented to ensure the elimination of the unwanted side bands in the microwave pump signal. A long life, high performance light source to be used in a trapped mercury ion microwave standard must be developed and the long term performance of a trapped mercury ion microwave standard must be investigated. While newly proposed two photon pumping schemes in conjuction with mercury ions promise exciting developments for both microwave and optical frequency standards, other ions that may be potential candidates should be evaluated for their usefulness.

Maleki, L.↗

The microwave structure of hot coronal loops

The thermal cyclotron emission from model dipole magnetic loops is computed. It is shown that a simple, isothermal dipole loop can show a great deal of spatial and polarization structure at microwave frequencies. This structure is sensitive to the observation frequency and angle of observation. Two qualitatively distinct microwave loop structures can be distinguished: (1) 'thin loop,' observed as a string of independent microwave peaks, corresponding to different harmonics of the local electron gyrofrequency; and (2) 'thick loop,' the harmonics are merged, so that a more continuous microwave structure is observed. It is shown that the presence of an external plasma can result in a change in the observed mode of polarization along one leg of a loop, without a change in the sign of the line-of-sight magnetic field. Models such as these, along with high-resolution microwave and related observations, can provide an excellent diagnostic of the magnetic and plasma properties of coronal loops.

Holman, G. D.↗

Determination of maritime snowfall from radar and microwave radiometer measurements

This study examines the effect of snowfall on high frequency microwave radiances measured from above the atmosphere by airborne radiometers. Attention is given to the analysis of a maritime snow storm so that snow accumulation on the surface would not introduce ambiguities into the analysis of the upwelling radiances.

Weinman, James A.↗

Exciton dressing by extreme nonlinear magnons in a layered semiconductor

Collective excitations presenting nonlinear dynamics are fundamental phenomena with broad applications. A prime example is nonlinear optics, where diverse frequency mixing processes are central to communication, sensing, wavelength conversion, and attosecond physics. Leveraging recent progress in van der Waals magnetic semiconductors, we demonstrate nonlinear opto-magnonic coupling by presenting exciton states dressed by up to 20 harmonics of magnons, resulting from their nonlinearities, in the layered antiferromagnetic semiconductor CrSBr. We also create tunable optical side bands from sum- and difference-frequency generation between two optically bright magnon modes under symmetry breaking magnetic fields. Moreover, the observed difference-frequency generation mode can be continuously tuned into resonance with one of the fundamental magnons, resulting in parametric amplification of magnons. These findings realize the modulation of the optical frequency exciton with the extreme nonlinearity of magnons at microwave frequencies, which could find applications in magnonics and hybrid quantum systems, and provide new avenues for implementing opto-magnonic devices.

Diederich, Geoffrey M.↗

A Continuous-Discontinuous Galerkin Method for Electromagnetic Simulations Based on an All-Frequency Stable Formulation

In this paper, a potential-based partial-differential formulation, called the all-frequency stable formulation, is presented for the accurate and robust simulation of electromagnetic problems at all frequencies. Due to its stability from (near) dc to microwave frequencies, this formulation can be applied to simulate wide-band and multiscale problems without encountering the infamous low-frequency breakdown issue or applying basis function decompositions such as the tree-cotree splitting technique. To provide both efficient and flexible numerical solutions to the electromagnetic formulation, a mixed continuous-discontinuous Galerkin (CDG) method is proposed and implemented. In regions with homogeneous media, the continuous Galerkin method is employed to avoid the introduction of duplicated degrees of freedom (DoFs) on the elemental interfaces, while on the interfaces of two different media, the discontinuous Galerkin method is applied to permit the jump of the normal components of the electromagnetic fields. Numerical examples are provided to validate and demonstrate the proposed numerical solver for problems in a wide electromagnetic spectrum.

Yan, Su↗

Advanced microelectronics research for space applications, phase 2

Negative-resistance circuits with possible space flight applications are discussed. The basic design approach is to use impedance rotation, i.e., the conversion from capacitance to negative resistance, and from resistance to inductance by the phase shift of the transistor current gain at high frequencies. The subjects discussed in detail are the following: hybrid fabrication of VHF and UHF negative-resistance stages with lumped passive elements; formulation of measurement techniques to characterize transistors and to extend the frequency of negative-resistance transistor amplifiers to higher microwave frequencies; and derivation of transistor characteristics required to increase the frequency range of negative-resistance transistor stages.

Gaertner, W. W.↗

A GHz-frequency multistrip acoustic beam splitter for quantum applications

Here we demonstrate a microwave-frequency, two-track acoustic beam splitter, based on a multistrip coupler design matched to four unidirectional transducers, two on each of the two acoustic tracks that make up the device. We explain the device design and its experimental implementation, showing good agreement between our model and the measured device scattering spectra. The beam splitter regime, dividing an input signal at port 1 into closely equal outputs at ports 2 and 3, is reached over a 94.7 MHz bandwidth centered at 4.79 GHz, with an output power division ratio |S 21 /S 31 | 2 = 1.1 ± 0.2. The measured bandwidth of the device is limited by the bandwidth of the transducers, rather than that of the multistrip coupler.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Foreground Emission

The WMAP mission has mapped the full sky to determine the geometry, content, and evolution of the universe. Full sky maps are made in five microwave frequency bands to separate the temperature anisotropy of the cosmic microwave background (CMB) from foreground emission, including diffuse Galactic emission and Galactic and extragalactic point sources. We define masks that excise regions of high foreground emission, so CMB analyses can became out with minimal foreground contamination. We also present maps and spectra of the individual emission components, leading to an improved understanding of Galactic astrophysical processes. The effectiveness of template fits to remove foreground emission from the WMAP data is also examined. These efforts result in a CMB map with minimal contamination and a demonstration that the WMAP CMB power spectrum is insensitive to residual foreground emission. We use a Maximum Entropy Method to construct a model of the Galactic emission components. The observed total Galactic emission matches the model to less than 1% and the individual model components are accurate to a few percent. We find that the Milky Way resembles other normal spiral galaxies between 408 MHz and 23 GHz, with a synchrotron spectral index that is flattest (beta(sub s) approx. -2.5) near star-forming regions, especially in the plane, and steepest (beta(sub s) approx. -3) in the halo. This is consistent with a picture of relativistic cosmic ray electron generation in star-forming regions and diffusion and convection within the plane. The significant synchrotron index steepening out of the plane suggests a diffusion process in which the halo electrons are trapped in the Galactic potential long enough to suffer synchrotron and inverse Compton energy losses and hence a spectral steepening. The synchrotron index is steeper in the WMAP bands than in lower frequency radio surveys, with a spectral break near 20 GHz to beta(sub s) less than -3. The modeled thermal dust spectral index is also steep in the WMAP bands, with beta(sub d) approx. = 2.2. Our model is driven to these conclusions by the low level of total foreground contamination at approx. 60 GHz. Microwave and Ha measurements of the ionized gas agree well with one another at about the expected levels. Spinning dust emission is limited to less than 5% of the Ka-band foreground emission. A catalog of 208 point sources is presented. The reliability of the catalog is 98%, i.e., we expect five of the 208 sources to be statistically spurious. The mean spectral index of the point sources is alpha approx. 0(beta approx. -2). Derived source counts suggest a contribution to the anisotropy power from unresolved sources of (15.0 +/- 1.4) x 10(exp -3)micro sq K sr at Q-band and negligible levels at V-band and W-band. The Sunyaev-Zeldovich effect is shown to be a negligible "contamination" to the maps.

Bennett, C. L.↗

Considerations for Detection of Dismounts with FOPEN Radar

The precise and accurate detection of dismounts is a desired capability for many radar systems. To detect dismounts under foliage requires using a radar with foliage penetrating (FOPEN) capability. FOPEN frequencies are subject to unique phenomenological aspects that are not typically encountered at microwave frequencies. This phenomenology places limitations on the feasibility of microwave radar approaches for dismount detection. This report provides an overview of these aspects of FOPEN radar system design.

47 OTHER INSTRUMENTATION↗

Airborne microwave radiometer remote sensing of lake ice

The NASA Langley C-Band Stepped Frequency Microwave Radiometer was used to conduct airborne remote sensing measurements of the Great Lakes ice cover during the winters of 1978 and 1979. In order to evaluate the use of microwave radiometry for remote sensing of fresh water ice, an initial experiment was conducted in February 1978. After the results were analyzed an algorithm was developed, and a more comprehensive mission was completed in March 1979, which related the thermal emission from lake ice to meaningful geophysical quantities. A clear discrimination of pressure ridges and rubble from base ice was observed, and evidence was found which showed gradual changes in the thickness of the base itself. Results indicate that passive microwave sensors can provide a measure of lake ice within uncertainties presented by the attenuation coefficient, and the changes in surface reflectivity imposed by surface roughness.

Swift, C. T.↗

A Compact Monolithic Electro-Optic Package for Quantum Microwave-to-Optical Transduction

We present a novel quantum transduction package that integrates a macroscopic electro-optic crystal into a compact, monolithic assembly designed for superconducting quantum processors. The device provides an efficient and scalable interface between microwave and optical domains while preserving cryogenic compatibility. We performed full-wave and quantum dynamical simulations to assess the performance of the hybrid system, focusing on the interaction between a transmon-based microwave cavity and the crystal’s and cavity low-frequency microwave mode. The transmon operates both as an ancilla for the QPU and as a nonlinear element enabling four-wave mixing between cavity and electro-optic crystal microwave fields. Our results indicate that this architecture can coherently mediate quantum information transfer from the cavity to the electro-optic mode, offering a promising platform for on-chip quantum transduction within superconducting quantum networks.

Reineri, Alessandro [Fermilab] (ORCID:000000016175↗