Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Mechanisms Underlying a Quantum Superposition Microscope Based on THz-Driven Coherent Oscillations in a Two-Level Molecular Sensor

Here we report pump-probe measurements of a hydrogen molecule (H 2 ) in the tunnel junction of a scanning tunneling microscope (STM) coupled to ultrashort terahertz (THz) pulses. The coherent oscillation of the THz induced DC tunneling current at a frequency of ~0.5 THz fingerprints the absorption by H 2 as a two-level system (TLS). Two components of the oscillatory signal are observed and point to both photon and field aspects of the THz pulses. A few loosely bound states with similar energies for the upper state of the TLS are evidenced by the coherent revival of oscillatory signal. Furthermore, the comparison of spectroscopic features of H 2 with different tips provides an understanding of the TLS for H 2 .

36 MATERIALS SCIENCE↗

Quantifying and visualizing the microscopic degrees of freedom of grain boundaries in the Wigner–Seitz cell of the displacement-shift-complete lattice

Here we introduce a grain boundary (GB) translation vector, t ws , to describe and quantify the domain of the microscopic degrees of freedom of GBs. It has long been recognized that for fixed macroscopic degrees of freedom of a GB there exists a large multiplicity of states characterized by different relative grain translations. More recently another degree of freedom, [n], the number of GB atoms, has emerged and is now recognized as an equally important component of GB structural multiplicity. In this work, we show that all GB microstates can be uniquely characterized by their value of t ws , which is located within the Wigner–Seitz (WS) cell of the Displacement-Shift-Complete lattice (DSCL) of the GB. The GB translation vector captures information about both the translation state and the number of GB atoms. We show that the density of GB microstates inside the WS cell of the DSCL is not uniform and can form clusters that correspond to different GB phases. Further, the vectors connecting the centers of the clusters correspond to the Burgers vectors of GB phase junctions, which can be predicted without building the junctions. Using t ws , we quantify GB excess shear and argue that it is defined up to a DSCL vector, which has implications for thermodynamic equilibrium conditions. Additionally, this work generalizes the definition of the number of GB atoms [n] to asymmetric boundaries.

36 MATERIALS SCIENCE↗

Pore-scale simulation of gas flow in microscopic permeable media with complex geometries

Lattice Boltzmann method (LBM) is an efficient tool to perform direct numerical simulation of gas flow in micro-size pores. Despite great advances in LBM and its use in describing gas flow in micro-size channels in slip and transitional flow regimes, exploring formulations that are able to capture flow behavior in domains with complex boundary geometries remains a challenging task. As a result, the impact of complexities in pore structures on gas flow may not be fully explored using LBM. In this study, we propose to use the combined bounce-back and Maxwellian diffusive reflection scheme to capture the slip velocity with a new set of slip coefficients. Optimal values of slip coefficients are determined using a gradient based method, where the results from the linearized Boltzmann equation is used as the reference solution. The proposed formulation is further validated against predictions from molecular dynamics simulation in the presence of complex geometries by introducing obstacles of different shapes in straight channels. LBM with the proposed boundary treatment is then used to investigate gas flow in a synthetic microscopic permeable medium. Here, results indicate that gas exhibits different flow configurations as Knudsen number varies, and apparent gas permeability appears to have up to a second-order dependency on the reciprocal mean pressure in slip and transitional flow regimes.

03 NATURAL GAS↗

Imaging Valley Excitons in a 2D Semiconductor with Scanning Tunneling Microscope-Induced Luminescence

Valley excitons dominate the optoelectronic response of transition-metal dichalcogenides and are drastically affected by structural and environmental inhomogeneities localized in these materials. Critical to understanding and controlling these nanoscale excitonic changes is the ability to correlate the imaging of excitonic states with crystalline structures on the atomic scale. Here, in this study, we apply scanning tunneling microscope-induced luminescence microscopy to image valley excitons in a semiconducting transition-metal dichalcogenide monolayer decoupled by a 10 nanometer-thick hexagonal-boron-nitride flake incorporated in a lateral homojunction on an Au electrode surface. This design enables the observation of chiral excitonic emission arising from neutral and charged valley excitons of the monolayer semiconductor at ambipolar voltages with a quantum efficiency up to similar to ~10 -5 photon/electron. The measured light helicity demonstrates considerable circular polarization dependent on the sample voltage, reaching as much as 40%. The real-space luminescence imaging maps$-$at subnanometer resolution$-$of the valley excitons reveal striking spatial variations associated with localized inhomogeneities, including surface impurities and possibly nanoscale dielectric and/or potential disorders in the monolayer. Our study introduces a promising format for 2D materials to explore and tailor their optoelectronic processes at the atomic scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A coded aperture microscope for X-ray fluorescence full-field imaging

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

36 MATERIALS SCIENCE↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

Laser Terahertz Emission Microscope for Imaging Grain Heterogeneity: A Case Study of CH3NH3PbI3 Perovskite Semiconductors

Strong terahertz (THz) emission from the methylammonium lead iodide (MAPbI3) perovskite semiconductors has been observed following above-bandgap photoexcitation, yet local THz responses of crystalline microstructures are absent. We implement laser THz emission microscope (LTEM), yet-to-be applied to the perovskite semiconductors, as a novel and complementary tool to evaluate the electronic and grain heterogeneity of MAPbI3 thin films. Two MAPbI3 samples with different grain sizes are studied. Using this approach, we show that the one with a larger grain size gives more uniform THz radiation. More significant spatial THz intensity fluctuation is observed for the sample with a smaller grain size.

36 MATERIALS SCIENCE↗