Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

Rapid Nucleic Acid Isolation Method and Fluid Handling Devices Overview

Sample preparation is a common bottleneck in genetic analysis. Tools that reduce time and effort are of value in a laboratory setting. There is a need for a genetic analysis/detection system that is not only mobile, ruggedized, easy-to-use but also provides an enclosed fluid handling that diminishes the risks of Ribonucleic acid (RNA) contamination and degradation during processing. NASA has developed a novel assay methodology and suite of devices to isolate nucleic acids and prepare samples for real-time (quantitative) polymerase chain reaction (PCR) analysis that solves the problem of contamination and degradation because of the advanced microfluidics which provides better fluid handling. The assay employs an aqueous-based non-alcohol method that yields robust RNA quality. The suite of ready-to-use devices provide pre-loaded reagents in liquid and lyophilized formats to enable rapid, cost effective, and portable manual operation in the laboratory or remote field environments.

Travis Boone↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic, Adaptive, Systems and Materials: Complex, Simple and Emergent Behaviors

This program has been funded by DoE/BES for twenty years. It has moved into and out of various subjects as it has developed, but it has retained its focus on complexity and complex systems. The project has evolved in the following way: Self-Assembly and Biomimetic Self-Assembly: All self-assembling systems depend upon a minimum of two types of interaction: a repulsion and an attraction. For the familiar molecular systems, attractive interactions are typically hydrogen bonds and electrostatic interactions. Repulsive interactions include steric effects, hydrophobic effects (in biological systems), and charge-charge repulsion. We have expanded this repertoire to include surface interactions, magnetic interactions, and others. I list these systems in the order in which we have explored them: i) A key emphasis in current work is in understanding how the movement of ions in a magnetic field (the Lorentz effect) interacts with catalytic systems. We have demonstrated that an acceleration in rate of reduction of CO 2 to CO can be accomplished by applying an external magnetic field. This acceleration is largely due to the application of the Lorentz effect on mass transport at the catalyst’s surface. ii) We have also extensively explored the influence of electrostatics, as exhibited in self-assembling systems, by tribocharging. iii) Another key system involves surface tension effects; examples include interactions between heavy particles floating at a liquid-air interface, and interacting by changes in surface area; interactions of bubbles and bubble rafts, behaviors of bubble trains in microfluidic networks, and behaviors of microorganisms in constraining environments. iv) This work has intentionally de-emphasized biological systems; but it does include some work on protein-ligand interactions and interactions among microorganisms. v) We have also explored applications of some of these effects, these explorations include bubble rafts as diffraction gratings, exploration of the structures that can be obtained by tribocharging and uses of these structures in exploring nucleation and melting of crystals. vi) Although not a major focus of this work, several other topics have emerged and offer opportunities for future work. These include the behavior of bubble trains and bubble rafts in microfluidic systems. A particularly interesting example is the formation of bubble trains that repeat in the alteration of large and small bubbles according to rules we do not presently understand, but are uniquely large-period oscillating systems. These systems offer a new route into understanding the instabilities of the type represented by oscillations. vii) We have also begun exploratory projects on magnetic levitation (especially to determine molecular density), and information storage (in molecules). Magnetic Levitation: Self-assembling and biomimetic systems require both attraction and repulsion. We have used electrostatics (tribocharging), interfacial free-energies (surface tension and related forces) and others. Potential uses include reconfigurable diffraction gratings and liquid lenses; exploration of mechanisms in tribocharging; tunneling in EGaIn junctions; and bubble trains (especially in micro-fluidic systems). Examples of systems representing these topics is included in the following papers: Complexity: Disks rotating at a water-air interface; Benard-Marangoni effects; Vortex-Crystals from spinning magnetic disks (Marangoni effects); EGaIn Electrode to study quantum tunneling; Self-Assembly of electrostatically-charged metallic spheres (electrets); Dynamically reconfigurable lens; Using computational designs of ligands for enzymes; Electrostatic self-assembly by tribocharging; Monodisperse bubble trains in microchannel systems; Inverted dripping faucet; Flames; Printing of micro-organisms to regenerate the “ink” of printing device; Using micro-organisms to move loads (“microoxen”); Motion of bacterial swarms near surfaces; Making monodisperse particles in microfluidic systems; Coding/decoding of information stored in droplet trains in microfluidic networks; Magnetic levitation; and Information storage. i) Tribocharging. The change in focus of this work on electrets from the fundamentals of charging to applications of these materials in studying self-assembly using electrostatic interactions. ii) Bubbles in Microchannels. The realization that systems of bubbles in microchannels represented a major opportunity to study complexity in a very tractable system, and the development of a semi-quantitative theory of this subject. iii) Flames. The growth of “flames” remains an exploratory subject for the research, although their currently relatively little active work involving it ongoing. iv) Systems with Microorganisms. The removal of work in biological systems from this project. Based on work supported in this program, we now have a significant project on the development of microfluidic tools for studying C. elegans (a nematode), but this work was not appropriate for a program focused on complexity, and we developed separate support for it. (It is, however, an example of successful seeding of a new area by BES.) The work on electrets has gone through a period in which a part of the program was the subject of a MURI; the focus of this work was to develop materials that did not charge electrostatically on friction or contact. The MURI is now over, and the work on dynamic self-assembly (supported by BES) is the major focus. “Flames” has also enjoyed synergistic support, in terms of a project supported by DARPA on flame suppression (in the absence of extinguishing agents, using acoustic and electrostatic interactions). This work was helpful in understanding some of the basics of flames, but is entirely distinct from the BES focus in complexity. A growing interest is in the Lorentz effect. The Lorentz effect is the force exerted on charged particles (electrons, ions, charged molecules) when they move through a perpendicular magnetic field. The Lorentz effect is almost ubiquitous in modern technology: examples of applications include electric motors, dynamos, cathode ray tubes, many batteries, and most systems that control electrical currents with magnetic forces. We have begun to explore the Lorentz effect in electrochemical systems and heterogeneous catalytic systems involving charged organic species and inorganic ions. This work is still at an early stage, but initial studies that Lorentz effects can be large when ions move through magnetic fields, or magnetic fields move in the presence of ions.

36 MATERIALS SCIENCE↗

Macromolecular Crystal Growth by Means of Microfluidics

We have performed a feasibility study in which we show that chip-based, microfluidic (LabChip(TM)) technology is suitable for protein crystal growth. This technology allows for accurate and reliable dispensing and mixing of very small volumes while minimizing bubble formation in the crystallization mixture. The amount of (protein) solution remaining after completion of an experiment is minimal, which makes this technique efficient and attractive for use with proteins, which are difficult or expensive to obtain. The nature of LabChip(TM) technology renders it highly amenable to automation. Protein crystals obtained in our initial feasibility studies were of excellent quality as determined by X-ray diffraction. Subsequent to the feasibility study, we designed and produced the first LabChip(TM) device specifically for protein crystallization in batch mode. It can reliably dispense and mix from a range of solution constituents into two independent growth wells. We are currently testing this design to prove its efficacy for protein crystallization optimization experiments. In the near future we will expand our design to incorporate up to 10 growth wells per LabChip(TM) device. Upon completion, additional crystallization techniques such as vapor diffusion and liquid-liquid diffusion will be accommodated. Macromolecular crystallization using microfluidic technology is envisioned as a fully automated system, which will use the 'tele-science' concept of remote operation and will be developed into a research facility for the International Space Station as well as on the ground.

vanderWoerd, Mark↗

Design and Simulation of a MEMS Structure for Electrophoretic and Dielectrophoretic Separation of Particles by Contactless Electrodes

Rapid identification of pathogenic bacterial species is an important factor in combating public health problems such as E. coli contamination. Food and waterborne pathogens account for sickness in 76 million people annually (CDC). Diarrheagenic E. coli is a major source of gastrointestinal illness. Severe sepsis and Septicemia within the hospital environment are also major problems. 75 1,000 cases annually with a 30-50% mortality rate (Crit Care Med, July '01, Vol. 29, 1303-10). Patient risks run the continuum from fever to organ failure and death. Misdiagnosis or inappropriate treatment increases mortality. There exists a need for rapid screening of samples for identification of pathogenic species (Certain E. coli strains are essential for health). Critical to the identification process is the ability to isolate analytes of interest rapidly. This poster discusses novel devices for the separation of particles on the basis of the dielectric properties, mass and surface charge characteristics is presented. Existing designs involve contact between electrode surfaces and analyte medium resulting in contamination of the electrode bearing elements Two different device designs using different bulk micromachining MEMS processes (PolyMUMPS and a PyrexBIGold electrode design) are presented. These designs cover a range of particle sizes from small molecules through eucaryotic cells. The application of separation of bacteria is discussed in detail. Simulation data for electrostatic and microfluidic characteristics are provided. Detailed design characteristics and physical features of the as fabricated PolyMUMPS design are provided. Analysis of the simulation data relative to the expected performance of the devices will be provided and subsequent conclusions discussed.

Shaw, Harry C.↗

Microfluidic Liquid-Liquid Extraction Chip with Integrated Raman Sensors (Phase I and Phase II Final Report)

As demand for electricity continues to increase worldwide, the world’s nuclear power generating capacity will continue to grow. Nuclear power is the most environmentally benign way of producing electricity on a large scale. The long-term successful use of nuclear power, however, is critically dependent upon adequate and safe processing and disposal of spent nuclear fuels. A very important feature of nuclear energy is that spent fuels can be reprocessed to recover fissile and fertile materials that can then be used as fresh fuel for nuclear power plants. The DOE-NE Fuel Cycle Research and Development (FCR&D) is currently developing nuclear material reprocessing technologies. In a typical nuclear fuel reprocessing system, centrifugal contactors are used as liquid-liquid extraction devices where two immiscible liquids are mixed at high speeds using a rotor, which creates a fine dispersion of droplets of organic phase in an aqueous phase that contains the analyte. Understanding the extraction efficiency at these contactors through modeling and simulation is important in the development of reprocessing technologies and the optimization of current technologies such as the PUREX process. The outcome of this program will be a liquid-liquid microfluidic flow cell chip with embedded spectroscopic sensors for the analysis of extracted analytes. This device will be useful in the optimization of new fuel reprocessing schemes as well as existing reprocessing processes by providing a microfluidic modeling platform to optimize extraction parameters. The Phase I and Phase II work developed a microfluidic chip design that allows integration of Raman and absorption fiber optic probes and successfully demonstrated the feasibility of using Raman and absorption probes to detect key analytes that partition into the aqueous and organic phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

About Small Streams and Shiny Rocks: Macromolecular Crystal Growth in Microfluidics

We are developing a novel technique with which we have grown diffraction quality protein crystals in very small volumes, utilizing chip-based, microfluidic ("LabChip") technology. With this technology volumes smaller than achievable with any laboratory pipette can be dispensed with high accuracy. We have performed a feasibility study in which we crystallized several proteins with the aid of a LabChip device. The protein crystals are of excellent quality as shown by X-ray diffraction. The advantages of this new technology include improved accuracy of dispensing for small volumes, complete mixing of solution constituents without bubble formation, highly repeatable recipe and growth condition replication, and easy automation of the method. We have designed a first LabChip device specifically for protein crystallization in batch mode and can reliably dispense and mix from a range of solution constituents. We are currently testing this design. Upon completion additional crystallization techniques, such as vapor diffusion and liquid-liquid diffusion will be accommodated. Macromolecular crystallization using microfluidic technology is envisioned as a fully automated system, which will use the 'tele-science' concept of remote operation and will be developed into a research facility aboard the International Space Station.

vanderWoerd, Mark↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗

All‐Liquid Reconfigurable Electronics Using Jammed MXene Interfaces

Abstract Rigid, solid‐state components represent the current paradigm for electronic systems, but they lack post‐production reconfigurability and pose ever‐increasing challenges to efficient end‐of‐life recycling. Liquid electronics may overcome these limitations by offering flexible in‐the‐field redesign and separation at end‐of‐life via simple liquid phase chemistries. Up to now, preliminary work on liquid electronics has focused on liquid metal components, but these devices still require an encapsulating polymer and typically use alloys of rare elements like indium. Here, using the self‐assembly of jammed 2D titanium carbide (Ti 3 C 2 T x ) MXene nanoparticles at liquid–liquid interfaces, “all‐liquid” electrically conductive sheets, wires, and simple functional devices are described including electromechanical switches and photodetectors. These assemblies combine the high conductivity of MXene nanosheets with the controllable form and reconfigurability of structured liquids. Such configurations can have applications not only in electronics, but also in catalysis and microfluidics, especially in systems where the product and substrate have affinity for solvents of differing polarity.

36 MATERIALS SCIENCE↗

Accelerating Biomimetic Solar - Energy Harvesting: Mapping the Interaction Landscape of Plasmonic-Excitonic Hybrid Nanosystems (Final Report)

In general, excitonic and plasmonic nanoscale materials in close proximity show high potential for significant breakthroughs in energy related materials research. The interactions between these two kinds of materials result in coupled optical transitions (plexcitons), distinct from those of both the individual exciton and plasmon as well as from those of the sum of their constituents (synergistic effects). By linking together materials-research and physical-research approaches, this project contributes to a concerted approach on nanomaterials energy research. The project’s overall goal is to accelerate the development of well-defined plexcitonic model systems consisting of carefully engineered plasmonic and excitonic nanomaterial— essential for both gaining a fundamental understanding of plexcitonic nanomaterials and the development of novel design principles for biomimetic solar energy harvesting. During the 3-year project period and the terminal renewal with limited support for a 12-month period, we successfully synthesized and characterized (1) a robust excitonic nanomaterial and (2) a library of plasmonic nanoparticles as well as developed (3) a microfluidic platform for homogenous nanosynthesis as summarized below: (1) Robust Excitonic Nanomaterial. Supramolecular assemblies are Nature’s most successful material system for solar energy harvesting. However, photovoltaic devices based on artificial supramolecular assemblies continue to be stymied by disappointing efficiencies and poor stability. The conceptual failure may lie in current solar cell architectures, which rely on solidifying supramolecular assemblies as an ensemble into a solid matrix, neglecting the intrinsic fragility of the assemblies’ internal structure, thus disrupting or even destroying their delicate optoelectronic properties, that is, delicate Frenkel excitonic properties. Supramolecular assemblies may finally serve as usable light harvesting material systems for solar energy conversion technologies, only if they meet the following criteria: (a) Stability, that is, the fragile structure including its delicate Frenkel excitonic character needs to be stable, (b) Robustness, that is, resistant against elevated and fluctuating temperatures, and (c) Viability for device integration, that is, capable of being immobilized onto solid substrates. Here, by developing a nanocomposite via a tunable, cage-like scaffold design, we successfully provided stable supramolecular nanocomposites, that inhabit robust Frenkel excitons despite harming environmental conditions such as extreme heat stress. (2) Library of Plasmonic Nanoparticles. Naturally, current models describing plasmonic hybrid quantum states—plasmonic hybridizations—parallel those developed for molecular orbitals, equating individual plasmonic nanostructures with “atoms” and the plasmonic nanoassemblies with “molecules.” In analogy to organic synthesis, a suitably robust fabrication method would allow for “atom-like” manipulation of “molecule-like” plasmonic nanoassemblies; of high value for next-generation energy nanotechnologies. Despite this frequent comparison, current plasmonic nanoassembly fabrication methods favor top-down templating over wet-chemical synthesis, however, achieving precise control over nanostructure’s geometry and surface characteristics remain an art and a scientific challenge. The conceptual failure may lie in the current wet-chemical synthesis paradigm, as it relies on the accessibility of a multi-dimensional synthesis parameter space through limited, rather one-dimensional synthesis procedures by employing step-by-step approaches. Solution-based nanoarchitectonics for rational design of precisely built plasmonic nanoassemblies via solution-based fabrication may finally be possible only if multi-dimensional syntheses approaches are available that allow for comprehensive control over the plasmonic nanomaterials’ (a) Structural Properties and (b) Surface Properties. Here, by developing an innovative multidimensional 1,3-propanediol based polyol synthesis, we successfully provided control over the plasmonic building-block’s geometry (size and shape) together with its surface characteristics. Our results present a critical step toward the vision of a “periodic table-like” system for plasmonic materials based on straightforward wet-chemical syntheses for energy nanotechnologies. Developing deliberate modifications on this synthesis, we generated a library of plasmonic nanostructures covering the vast parameter space—opening the door for fundamental investigation of plexcitonic model systems. (3) Microfluidic Platform for Homogenous Nanosynthesis. Control over structural properties of plexcitonic nanocomposites remains a challenge due to current limitations in nanosynthesis techniques. Slight variations in nanostructure’s geometry impact their optoelectronic properties, demanding precise synthesis beyond the capabilities of solution-based (batch) synthesis processes. In contrast, the small, confined liquid volumes used in microfluidics—a reaction technique where the manipulation of fluids takes place in channels with dimensions of tens of micrometers—allows for homogenous synthesis conditions, providing excellent control of the reaction and, as a result, of the materials’ geopmetry and composition. However, thus far, the majority of plexcitonic systems has been developed via batch synthesis. Here, by successfully developing a two-channel microreactor, our microfluidic-supported synthesis approach combines the advantages of both microfluidics and batch platforms, allowing for precise spatio-temporal control over all synthesis parameters opening the possibility for homogenous nanosythnesis of well-defined plexcitonic model systems.

14 SOLAR ENERGY↗

Microwell Arrays for Studying Many Individual Cells

"Laboratory-on-a-chip" devices that enable the simultaneous culturing and interrogation of many individual living cells have been invented. Each such device includes a silicon nitride-coated silicon chip containing an array of micromachined wells sized so that each well can contain one cell in contact or proximity with a patch clamp or other suitable single-cell-interrogating device. At the bottom of each well is a hole, typically 0.5 m wide, that connects the well with one of many channels in a microfluidic network formed in a layer of poly(dimethylsiloxane) on the underside of the chip. The microfluidic network makes it possible to address wells (and, thus, cells) individually to supply them with selected biochemicals. The microfluidic channels also provide electrical contact to the bottoms of the wells.

Folch, Albert↗

Piezoelectrically Actuated Microvalve for Liquid Effluents

Modifications have been proposed to effect further improvement of the device described in Improved Piezoelectrically Actuated Microvalve (NPO-30158), NASA Tech Briefs, Vol. 26, No. 1 (January 2002), page 29. To recapitulate: What is being developed is a prototype of valves for microfluidic systems and other microelectromechanical systems (MEMS). The version of the valve reported in the cited previous article included a base (which contained a seat, an inlet, and an outlet), a diaphragm, and a linear actuator. With the exception of the actuator, the parts were micromachined from silicon. The linear actuator consisted of a stack of piezoelectric disks in a rigid housing. To make the diaphragm apply a large sealing force on the inlet and outlet, the piezoelectric stack was compressed into a slightly contracted condition during assembly of the valve. Application of a voltage across the stack caused the stack to contract into an even more compressed condition, lifting the diaphragm away from the seat, thereby creating a narrow channel between the inlet and outlet. The positions of the inlet and outlet, relative to the diaphragm and seat, were such that the inlet flow and pressure contributed to sealing and thus to a desired normally-closed mode of operation.

Yang, Eui-Hyeok↗

Thioaptamer Diagnostic System (TDS)

AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

Yang, Xianbin↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Microfluidic Operations Underlying an Electrowetting Heat Pipe on the International Space Station

Electrowetting heat pipes (EHPs) are a newly conceptualized class of heat pipes, wherein the adiabatic wick section is replaced by electrowetting-based pumping of the condensate (as droplets) to the evaporator. Specific advantages include the ability to transport high heat loads over long distances, low thermal resistance and power consumption, and the absence of moving mechanical parts. In this work, we describe characterization of key microfluidic operations (droplet motion and splitting) underlying the EHP on the International Space Station (ISS). The testing was performed under the Advanced Passive Thermal eXperiment (APTx) project, a project to test a suite of passive thermal control devices funded by the ISS Technology Demonstration Office at NASA JSC (Johnson Space Center). A rapid manufacturing method was used to fabricate the electrowetting device on a printed circuit board. Key device-related considerations were to ensure reliability and package the experimental hardware within a confined space. Onboard the ISS, experiments were conducted to study electrowetting-based droplet motion and droplet splitting, by imaging droplet manipulation operations via pre-programmed electrical actuation sequences. An applied electric field of 36 Volts per micron resulted in droplet speeds approaching 10 millimeters per second. Droplet splitting dynamics were observed and the time required to split droplets was quantified. Droplet motion data was analyzed to estimate the contact line friction coefficient. Overall, this demonstration is the first-ever electrowetting experiment in space. The obtained results are useful for future design of the EHP and other electrowetting-based systems for microgravity applications.

Electrowetting↗