Distributed Attitude Control and Maneuvering for Deep Space SmallSats

The aim of the Distributed Attitude Control and Maneuvering for Deep Space SmallSats project is to advance a multi-purpose, deep space mission-enabling technology for low-power attitude and thermal control of small satellites to a flight demonstration technology readiness level (TRL). The film-evaporation microelectromechanical systems tunable array (FEMTA) small satellite technology combines innovative microelectromechanical systems (MEMS) microfabrication and microscale effects in fluid surface tension to produce a thermally actuated capillary valve. Using water as the propellant, the FEMTA thruster can generate finely controllable thrust at a thrust to power ratio of about 200 microNewton per Watt (W).

thermal control↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Multi-Channel Correlator Array-Fed Microwave Radiometer

New antenna feed technology is needed for microwave radiometers as aperture sizes continue to increase. Capability for contiguous coverage and spatial Nyquist sampling can be achieved using a multi-beam array-fed reflector architecture adapted from radio astronomy. In this ACT (Advanced Component Technology), a wideband feed array for use in a multi-channel (X-W bands) scanning microwave radiometer is in development. The team, including array provider Nuvotronics Inc., is also developing a laboratory instrument to demonstrate the performance of the array-fed architecture at 36.5 gigahertz using an 80-centimeter projected aperture. The feed array is an 11-element line array based on a microfabricated 8-40 gigahertz feed. Multiple beams are generated by exciting overlapping groups of elements with each group shifted by one element spacing within the array. The modeled antenna patterns reveal six beams with 0.8-degree beamwidth and 0.3-degree spacing. This configuration is also a 1:26 electromagnetic scale model of a 1.41 gigahertz radiometer with a 21-meter aperture. The array-fed architecture for microwave radiometers has the potential to solve the developing need for high-spatial resolution, large aperture instruments. The objective relevancy scenario is a 6-meter aperture X-W band scanning radiometer purposed for high-resolution all-weather imaging of Earth's atmosphere and land, ice and ocean surfaces.

Microwave Radiometer↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Optical Design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

This work describes the optical design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping(EXCLAIM). EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbonmonoxide (CO) at redshiftsz <1 and ionized carbon ([CII]) at redshiftsz= 2.5−3.5 to probe star forma-tion over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM instrument will observeat frequencies of 420–540 GHz using six microfabricated silicon integrated spectrometers with spectral resolv-ing powerR= 512 coupled to kinetic inductance detectors (KIDs). A completely cryogenic telescope cooledto a temperature below 5 K provides low-background observations between narrow atmospheric lines in thestratosphere. Off-axis reflective optics use a 90-cm primary mirror to provide 4.2′full-width at half-maximum(FWHM) resolution at the center of the EXCLAIM band over a field of view of 22.5′. Illumination of the 1.7 Kcold stop combined with blackened baffling at multiple places in the optical system ensures low (<−40 dB) edgeillumination of the primary to minimize spill onto warmer elements at the top of the dewar.

Thomas Essinger-Hileman↗

Design of ZnSe QPM for Wide Transparency Sensing and Laser Applications

ZnSe has been a great choice for the rare-earth and transition metal doping to develop lasers. It is an excellent materialfor variety of optical applications due to wide transparency range, good fabricability and very low optical absorptionsimilar to other selenides. NASA Marshall Space Flight Center has developed large crystals using physical vapordeposition (PVD) doped with transition metals for lasing. GaAs based quasi-phase matched structures have a lot oflimitations including difficulty of frequency conversion from available high power lasers. We are developing Si- andGaAs- based templates and using microfabrication process to deposit ZnSe using physical vapor transport (PVT)method. Experimental results of the fabrication of templates and growth of ZnSe on templates will be presented.

Epitaxial↗

Silicon Carbide Sensors and Electronics Technology for Extreme Environments: Opportunities for Nuclear Power Applications

Over the past five decades, NASA Glenn Research Center had been advancing the development of single crystal silicon carbide growth, sensors and electronics device technologies, culminating in the recent demonstration of Micro-Electro-Mechanical Systems scale batch fabricated pressure sensors operating at 800 °C and integrated circuit electronics with demonstrated durability of over 1000 hours at 500 °C. As a result of the progress made in demonstrating the high temperature capability of the technology, insertion into actual operational environments, such as in jet engines and planet Venus, are in progress. The high temperature, near inert surface chemistry, and radiation hardness attributes of SiC, coupled with the relative maturation of the device batch microfabrication, contact metallization, and packaging technologies, make the material a prime candidate for use as part of future advanced nuclear reactor instrumentation and control strategy. Hence the current research efforts at NASA Glenn are aimed toward harnessing these attributes in developing SiC sensors and electronics for nuclear reactor applications, potentially for future Lunar/Martian nuclear power and the emerging terrestrial micro nuclear power plants.

silicon carbide↗

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health↗

Holey Silicon-based Thermopiles for High-Sensitivity Broadband Thermal Detection in Space

Future planetary missions call for thermal detectors with high sensitivity over a wide range of temperature or wavelength. Conventional approaches based upon photon detectors are limited to a narrow and material-selective range of wavelength, and they often require cryogenic cooling for measurements of far-infrared (FIR) radiation or very low-temperature objects, which result in a significant increase in the system’s size, weight, and power (SWaP). While thermal detectors based upon thermopiles are uncooled and sensitive to a wide range of wavelengths including FIR radiation, their sensitivity, limited by the material’s thermoelectric response and heat losses, is an order of magnitude lower than photon detectors. To address the sensitivity requirements for future planetary science missions that target very cold objects such as ice giant planets, icy regoliths, planetary satellites, and primitive bodies, we introduce a high-sensitive broadband thermopile concept using holey silicon – a thin membrane of silicon with a microfabricated arrangement of pores that can be optimized to minimize heat losses and enable breakthrough thermoelectric performance. In this paper, we present our analytical model for the holey silicon-based thermopile, its performance expectations, and its performance comparisons with the state-of-the-art thermopile technology. We will investigate the roles of thermal conductance in holey silicon-based thermopile performance, the impact of thermal conduction and thermal radiation at different temperature limits, and the performance trade-off between the responsivity and noises.

thermopiles↗