Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

State-resolved ultrafast charge and spin dynamics in [Co/Pd] multilayers

We use transient absorption spectroscopy with circularly polarized x rays to detect laser-excited hole states below the Fermi level and compare their dynamics with that of unoccupied states above the Fermi level in ferromagnetic [Co/Pd] multilayers. While below the Fermi level, an instantaneous and significantly stronger demagnetization is observed, above the Fermi level, the demagnetization is delayed by 35 ± 10 fs. This provides a direct visualization of how ultrafast demagnetization proceeds via initial spin-flip scattering of laser-excited holes to the subsequent formation of spin waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

X-ray imaging and radiation transport effects on cylindrical implosions

Magnetization of inertial confinement implosions is a promising means of improving their performance, owing to the potential reduction of energy losses within the target and mitigation of hydrodynamic instabilities. In particular, cylindrical implosions are useful for studying the influence of a magnetic field, thanks to their axial symmetry. In this work, we present experimental results from cylindrical implosions on the OMEGA-60 laser using a 40-beam, 14.5 kJ, 1.5 ns drive and an initial seed magnetic field of B 0 = 30 T along the axes of the targets, compared with reference results without an imposed B-field. Implosions were characterized using time-resolved x-ray imaging from two orthogonal lines of sight. We found that the data agree well with magnetohydrodynamic simulations, once radiation transport within the imploding plasma is considered. We show that for a correct interpretation of the data in these types of experiments, explicit radiation transport must be taken into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

Diagnosing low-mode (ℓ < 6) and mid-mode (6 ≤ ℓ ≤ 60) asymmetries in the post-stagnation phase of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA

Low- and mid-mode perturbations are possible candidates for performance limitations in cryogenic direct-drive implosions on the OMEGA laser at the Laboratory of Laser Energetics. Simulations with a 3D hydrocode demonstrated that hotspot imagers do not show evidence of the shell breakup in the dense fuel. However, these same simulations revealed that the low- and mid-mode perturbations in the dense fuel could be diagnosed more easily in the post-stagnation phase of the implosion by analyzing the peak in the x-ray emission limb at the coronal–fuel interface than before or at the stagnation phase. In experiments, the asymmetries are inferred from gated images of the x-ray emission of the implosion by using a 16-pinhole array imager filtered to record x-ray energies >800 eV and an x-ray framing camera with 40-ps time integration and 20-μm spatial resolution. Furthermore, a modal analysis is applied to the spatial distribution of the x-ray emission from deuterium and tritium cryogenic implosions on OMEGA recorded after the bang time to diagnose the low- and mid-mode asymmetries, and to study the effect that the beam-to-target ratio (Rb/Rt) has on the shell integrity.

47 OTHER INSTRUMENTATION↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiframe X-ray diffraction on the OMEGA EP laser

A method of measuring multiple temporally resolved powder x-ray diffraction measurements during a single dynamic compression laser experiment has been demonstrated on the OMEGA EP laser. Up to four time-gated snapshots of the x-ray diffraction pattern are collected on an ultrafast x-ray framing camera with a 2θ scattering angle coverage of 48°–65° and 400-ps temporal resolution with the potential for 10°–160° and 200-ps resolution. X-ray diffraction snapshots capture the transformation to a high-pressure β phase in ramp-compressed Zr, constraining the atomic structure and pressure–density equation-of-state in a single shot. Here, this platform will be used to constrain transition pressures, understand the role of kinetics, and verify the existence of hysteresis and metastability on phase transformations at the lattice level under single-shot dynamic compression.