Micro-tensile testing of the bond line in hot isostatic pressed aluminum

Considerable effort is being devoted to development and regulatory qualification of low enriched fuels for research and test reactors by many agencies worldwide. One promising fuel configuration being examined for United States higher power research and test reactors (USHPRRs) are plate-type fuels composed of a metallic uranium-molybdenum foil clad in an aluminum alloy. The two pieces of aluminum alloy cladding are bonded using a hot isostatic pressing method. The mechanical properties of the resulting bond line in the aluminum alloy cladding will vary by the HIP'ing parameters, requiring a need to characterize the bond line. Small scale mechanical testing can provide a path for evaluating the mechanical properties and deformation behavior of the bond line both prior to and following irradiation. Here, in this research, room temperature micro-tensile specimens of non-irradiated and irradiated samples containing an Al alloy (AA 6061) bond line were tested to evaluate its strength and deformation behavior. Observations indicated that the strain rate did not affect the deformation behavior or strength and most of the micro-tensile specimens failed in a ductile mode in grains around the bond line. There was no indication that the microstructural features from the bond line affected the mechanical properties of the micro-tensile specimens. An initial examination was performed on irradiated material but further systematic studies of the effects of irradiation can be performed in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro-beam bending of FCC bicrystals: A comparison between defect dynamics simulations and experiments

To understand the role of the grain boundary (GB) in plasticity at small scale, a concurrently coupled mesoscale plasticity model was developed to simulate micro-bending of bicrystalline micron-sized beams. By coupling dislocation dynamics (DD) with a finite element model (FEM), a novel defect dynamics model provides the means to investigate intricate interactions between dislocations and GBs under various loading conditions. Our simulations of micro-bending agree well with corresponding micro-bending experiments, and they show that mechanical response of bicrystals could have not only hardening but also softening depending on the characters of the GB. In addition, changing the location of the GB in the microbeams results in different mechanical responses; GBs located at the neutral plane show softening compared to single crystals, while inclined GBs located halfway along the length of the beam show little effect. In conclusion, simulation results could provide a clear picture on detailed dislocation-GB interactions, and quantitative resolved shear stress analysis supplemented by dislocation density distribution is used to analyze the mechanical response of bicrystalline samples.

36 MATERIALS SCIENCE↗

Gas Transfer Across Air‐Water Interfaces in Inland Waters: From Micro‐Eddies to Super‐Statistics

In inland water covering lakes, reservoirs, and ponds, the gas exchange of slightly soluble gases such as carbon dioxide, dimethyl sulfide, methane, or oxygen across a clean and nearly flat air‐water interface is routinely described using a water‐side mean gas transfer velocity $\overline{k_{L}}$, where overline indicates time or ensemble averaging. The micro‐eddy surface renewal model predicts $\overline{k_{L}}$ = α o Sc -1/2 ($v\bar{ϵ}$) 1/4 , where Sc is the molecular Schmidt number, $v$ is the water kinematic viscosity, and $\bar{ϵ}$ is the waterside mean turbulent kinetic energy dissipation rate at or near the interface. While α o = 0.39 - 0.46 has been reported across a number of data sets, others report large scatter or variability around this value range. It is shown here that this scatter can be partly explained by high temporal variability in instantaneous ϵ around $\bar{ϵ}$, a mechanism that was not previously considered. As the coefficient of variation (CV e ) in ϵ increases, α o must be adjusted by a multiplier (1 = CV e 2 ) -3/32 that was derived from a log‐normal model for the probability density function of ϵ. Reported variations in α o with a macro‐scale Reynolds number can also be partly attributed to intermittency effects in ϵ. Such intermittency is characterized by the long‐range (i.e., power‐law decay) spatial auto‐correlation function of ϵ. That α o varies with a macro‐scale Reynolds number does not necessarily violate the micro‐eddy model. Instead, it points to a coordination between the macro‐ and micro‐scales arising from the transfer of energy across scales in the energy cascade.

Batchelor scale↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fully Self-Contained Vision-Aided Navigation and Landing of a Micro Air Vehicle Independent from External Sensor Inputs

Direct-lift micro air vehicles have important applications in reconnaissance. In order to conduct persistent surveillance in urban environments, it is essential that these systems can perform autonomous landing maneuvers on elevated surfaces that provide high vantage points without the help of any external sensor and with a fully contained on-board software solution. In this paper, we present a micro air vehicle that uses vision feedback from a single down looking camera to navigate autonomously and detect an elevated landing platform as a surrogate for a roof top. Our method requires no special preparation (labels or markers) of the landing location. Rather, leveraging the planar character of urban structure, the landing platform detection system uses a planar homography decomposition to detect landing targets and produce approach waypoints for autonomous landing. The vehicle control algorithm uses a Kalman filter based approach for pose estimation to fuse visual SLAM (PTAM) position estimates with IMU data to correct for high latency SLAM inputs and to increase the position estimate update rate in order to improve control stability. Scale recovery is achieved using inputs from a sonar altimeter. In experimental runs, we demonstrate a real-time implementation running on-board a micro aerial vehicle that is fully self-contained and independent from any external sensor information. With this method, the vehicle is able to search autonomously for a landing location and perform precision landing maneuvers on the detected targets.

autonomous landing↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Review of Graphite Properties Relevant to Micro-Reactor Design

Microreactors are advanced reactors that are designed to be small, scalable, and portable with up to 20 MW power. These reactors could operate independently, or as part of a microgrid, without need of a frequent refueling. Micro-reactors are designed to be deployable to provide electric power in remote locations, therefore providing greater flexibility. Several micro-reactors are under development in the US. These reactors are based on advanced gas-cooled or heat-pipe concepts. While Graphite can be found in various applications, some high-temperature reactors plan to employ Graphite in their core components due to its role as a moderator and its ability to maintain its structural integrity when subjected to elevated temperatures and high neutron fluence. Although there is significant experience with use of Graphite in nuclear applications, there are still unknowns that should be addressed. Graphite properties depend on the graphite type and affected by the fabrication procedures. Material properties are functions of the temperature and irradiation dose. The fundamental properties also affected by the oxidation environment. Therefore, in-depth understanding of graphite properties, including the effect of irradiation, oxidation and other influencing parameters are required to evaluate the design accurately. This draft aims to provide a comprehensive review of material properties for Graphite relevant to micro reactor design. For this work, two distinct grades of graphite were considered, namely IG-110 and Mersen-2114. Physical, thermal, and mechanical properties for these grades were comparatively evaluated. The properties that are discussed in this draft aim to serve as a basis for design and safety analysis.

42 ENGINEERING↗

Transient Analysis of a Micro-reactor using the DireWolf Code Suite

Transient analyses of heat pipe micro-reactors are necessary to ensure that hypothetical accident scenarios do not comprise reactor safety. Due to its small size and reliance on heat-pipes for cooling, the micro-reactor design introduced in this paper is a tightly coupled system which requires multi-physics tools to accurately model transient events. Idaho National Laboratory’s DireWolf code suite based on the MOOSE framework is tailor-built to model heat-pipe reactors. This paper demonstrates DireWolf’s ability to simulate the coupled thermal-neutronics transient behavior of a heat-pipe micro-reactor. The transient events presented here include an inadvertent rotation of all control drums simultaneously and a sudden complete ejection of a single control drum. A detailed description of each event is provided along with simulation results, including time dependent power and temperature distributions, and discussion. This is a Westinghouse Electric Company (WEC) led publication.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling and Analysis of a Micro-reactor using the DireWolf Code Suite

Micro-reactors, specifically those cooled with heat pipes, are tightly coupled systems which require multi-physics tools to accurately model both steady-state and transient behavior. Idaho National Laboratory’s DireWolf code suite is tailor-built to model heat-pipe reactors. DireWolf’s ability to model the coupled steady-state behavior of a heat-pipe micro-reactor are demonstrated herein. The DireWolf modeling methodology is described, and a micro-reactor design is introduced. A full-core model is developed, and the steady-state coupled neutronics-thermal analysis is performed. Results of the analyses, including flux, power, and temperature distributions are presented and discussed. This is a Westinghouse Electric Company (WEC) led publication.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Freestanding Photoresist Film: A Versatile Template for Three-Dimensional Micro- and Nanofabrication

Ultrathin freestanding films with well-defined micro/nanostructures and robust mechanical properties are applied in many engineering applications including microelectronics, optics, filtration and separation, biomedical engineering, and nanotechnology. Although considerable efforts have been made toward the fabrication of freestanding thin films, it is still a significant challenge to develop a simple and reliable process for producing freestanding films with ultrathin thickness, well-regulated micro/nanopatterns, robust mechanical properties, macroscopic coverage area, and multi-layered composite structures. In this work, a significant advancement is reported in this regard. This study shows a new sacrificial-layer-free (SLF) lifting-off process, integrated with conventional micro- and nanolithography, enabling the release of micro- and nanopatterned photoresist (PR) films from the supporting substrate with unprecedented pattern coverage and structure characteristics. The freestanding PR film is resilient, can withstand significant bending and deformation, and is sufficiently flexible to be transferred onto substrates with 3D topography as a conformal soft stencil for further technological processing and applications. Moreover, the SLF lifting-off process provides a simple approach to prepare single-layered and multi-layered freestanding composite films. The results suggest that the novel SLF lifting-off process can significantly extend the capability of 3D micro-/nanofabrication.

36 MATERIALS SCIENCE↗

Linking DSC/TGA to Cell Levels: Energetics, Evolved Gases, and Thermal Safety of NMC811‐Graphite Micro‐Cell

Thermochemical characterization of battery materials links intrinsic material properties to decomposition pathways, heat generation, and gas evolution that govern performance and safety. Despite extensive work on NMC811-Graphite, variability across partial configurations and the limited adoption of micro-cell architectures (cathode+anode+electrolyte+separator) hinder robust cell-scale interpretation. Accordingly, this work establishes a bottom-up, component-resolved methodology integrating DSC/TGA, evolved gas analysis (EGA), and in situ XRD to link decomposition pathways and energy release across partial and micro-cell configurations, providing a transferable assessment of safety and stability in emerging chemistries. In separator-free configurations, the gas–solid reaction between cathode-evolved O 2 and anode-leached Li dominates the net heat release (1139 J g −1 ). In contrast, in the micro-cell configuration, the separator hinders O 2 transport and alters the timing and pathways of other reactions, and reduces the net energy release to 618 J g −1 . Energy release was organized into defined temperature windows that provide a framework for a thermodynamic model combining quantified gas evolution with selected decomposition pathways and effective reaction enthalpies to estimate net specific energy release, with agreement between DSC and cell-level tests. Ex situ XPS of heat-treated samples extends post-mortem analysis to thermal-abuse regimes, supporting key pathway elements.

25 ENERGY STORAGE↗

Comparative Study of Solvatomorphs of Stryker's Reagent Using MicroED and Quantum Mechanics

Abstract The atomic position of hydrogen atoms in metal hydrides has been a long‐standing structural question in inorganic chemistry given that hydride delivery is integral to diverse chemical reactions. Microcrystal electron diffraction (microED), with it's increased sensitivity toward hydrogen atoms relative to X‐ray diffraction, offers a potential path to addressing this challenge. Herein, the first microED study of Stryker's reagent is reported, resulting in the structure of a new benzene solvate. Improved accuracy for hydrogen atom positions was obtained via a quantum crystallography (QCr) approach, Hirshfeld atom refinement (HAR). Structural and topological analysis supports edge bridging hydrides in the microED structure of a THF solvate form, consistent with previous diffraction studies. Interestingly, analysis of a new benzene solvate, discovered in this study, is consistent with mixed edge‐ and face‐bridging hydrides.

Jha, Kunal K. [Division of Chemistry &amp, Chemica↗

Number of sites-based solver for determining coverages from steady-state mean-field micro-kinetic models

Kinetic models parameterized by ab-initio calculations have led to significant improvements in understanding chemical reactions in heterogeneous catalysis. These studies have been facilitated by implementations which determine steady-state coverages and rates of mean-field micro-kinetic models. As implemented in the open-source kinetic modeling program, CatMAP, the conventional solution strategy is to use a root-finding algorithm to determine the coverage of all intermediates through the steady-state expressions, constraining all coverages to be non-negative and to properly sum to unity. Though intuitive, this root-finding strategy causes issues with convergence to solution due to these imposed constraints. In this work, we avoid explicitly imposing these constraints, solving the mean-field steady-state micro-kinetic model in the space of number of sites instead of solving it in the space of coverages. Here, we transform the constrained root-finding problem to an unconstrained least-squares minimization problem, leading to significantly improved convergence in solving micro-kinetic models and thus enabling the efficient study of more complex catalytic reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Pathway to Decarbonization Through Industrial Energy Efficiency: Micro and Macro Perspectives from Compressed Air Usage

Abstract Energy audits directly provided the industrial sector with reduced energy costs and avoided emissions. Still, they also lead to far-reaching indirect and induced local, regional, and national benefits. This paper aims to present the techno-economic-environmental analysis to achieve decarbonization through implementing industrial energy efficiency at micro and macro levels. An integrated techno-economic-environmental methodology is developed. Case studies of micro-level carbon reduction efforts through industrial energy efficiency technologies are presented. The broader macroeconomic and environmental effects of technology on society are analyzed using data from 206 energy audits of industrial compressed air systems conducted over 13 years. The impacts show that energy-efficient improvements lead to direct cost savings for manufacturers, boost economic activity across sectors, and affect carbon dioxide emissions both short-term and long-term in the region. Given their extensive benefits, energy audits significantly influence policymaking. We devised a methodology to link micro-level energy audit data with macroeconomic and environmental analyses to quantify these cascading benefits. The economic scenario analysis shows that $228 M has been saved from direct industrial energy savings from implementing all compressed air recommendations in the studied periods and the region. In addition, the investment made through manufacturers would create 2,025 jobs and $383 M annually, cascading regional economic impacts. The environmental analysis shows that the regional manufacturers have directly avoided about 2.8 M metric tons of carbon dioxide emissions.

Engineering↗

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

Comparative investigations of multi-fidelity modeling on performance of electrostatically-actuated cracked micro-beams

Silicon is a commonly used material for the fabrication of beams for use in micro-electrical-mechanical systems (MEMS). Although silicon is a brittle material, it has been shown to accumulate fatigue damage at the micro-scale. Understanding the effect this has on the overall device performance is critical to the design of reliable devices. Analytical methods for modeling damage provide expedient results but are limited by broad modeling assumptions. Numerical models account for more detailed physical phenomena but can be computationally intensive. In this work, two different crack scenarios are modeled using both analytical techniques and 3D computational simulations. First, the effects of a single surface crack on the static deflection and natural frequency of an electrostatically actuated micro-beam are formulated and compared. Then, a new method for approximating damage associated with realistic distributed crack networks is formulated for use in an analytical model and numerical simulations. A method for utilizing experimentally derived crack statistics to inform the analytical and numerical distributed crack models is developed. Good agreement between the analytical and numerical models is obtained for both crack scenarios. Altogether, these models can be used to effectively simulate a variety of damage and fatigue behaviors in silicon-based MEMS devices.

42 ENGINEERING↗