Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A dynamic study of fragmentation and energy loss during high velocity impact

Research conducted under this contract can be divided into two main areas: hypervelocity (in the range up to 7 km/s) and high velocity (less than 1 km/s). Work in the former was performed at NASA-MSFC using the Light Gas Gun Facility. The lower velocity studies were conducted at Auburn University using the ballistic gun. The emphasis of the project was on the hypervelocity phenomenon especially in the characterization of the debris cloud formed by the primary impact events. Special devices were made to determine the angular distributions of momentum and energy of the debris cloud as a function of impact conditions. After several iteration processes, it was decided to concentrate on the momentum effort. Prototype devices were designed, fabricated, and tested. These devices were based on the conservation of momentum. Distributions of the debris cloud formed were measured by determining the amount of momentum transferred from the debris cloud to strategically placed pendulum measurement devices. The motion of the pendula was monitored using itegrated opto-interrupters. The distribution of momentum in the debris cloud was found to be a strong function of the impact condition. Small projectiles at high velocities were observed to produce finely dispersed debris whereas large projectiles generated discrete particles in the debris. Results also show that the momentum in the forward direction was enhanced due to the impact. This phenomenon of momentum multiplication was also observed in other studies and in computer simulations. It was initially planned to determine the energy distribution using deformation energy in a rod with strain gauges. Results from preliminary studies show that this technique is acceptable but too tedious. A new technique was explored based on measuring the heating effect of the debris cloud using an IR camera. The feasibility and sensitivity was established at Auburn University. This type of energy distribution measurement method can easily be adapted to the gas gun facility at MSFC. The objective of the lower velocity studies at Auburn was to simulate the damage produced in advanced materials by the lower energy debris cloud.

Zee, Ralph H.↗

COMPAS: Compositional mineralogy with a photoacoustic spectrometer

There is an important need for an in situ method of mineral and rock identification and quantification that provides true absorption spectra for a wide spectral range for lunar lander/rover missions. Many common minerals such as feldspars, magnetite, ilmenite, and amorphous fine solids or glasses, can exhibit flat spectral reflectances in the 400-2500 nm spectral region that render inaccurate or difficult their spectral detection and quantitative analysis. Ideal rock and mineral spectra are, of course, pure absorption spectra that are independent of the spectral effects of scattering, particle size, and distribution that can result in a suppression or distortion of their spectral features. This ideal seldom pertains to real samples. Since sample preparation is difficult and may fundamentally alter the observed diffuse spectral reflectance, an in situ spectral measurement method for rocks and minerals on the Moon, insensitive to the sample morphology, would be invaluable. Photoacoustic spectroscopy is a well-established technique appropriate for this task that has been widely applied in condensed-phase spectral studies of complex, highly light scattering, unprepared samples of everything from coal to whole blood, including rock and mineral characterization. A Compositional Mineralogy Photoacoustic Spectrometer, or COMPAS, can enable in situ spectral measurement of rocks and minerals, bypassing the major limitations of diffuse reflectance spectroscopy. COMPAS spectral capabilities for rock and mineral samples will be incorporated into an instrument prototype specifically for lunar measurements, compatible with rover capabilities.

Smith, W. Hayden↗

Rotating rake design for unique measurement of fan-generated spinning acoustic modes

In light of the current emphasis on noise reduction in subsonic aircraft design, NASA has been actively studying the source of and propagation of noise generated by subsonic fan engines. NASA/LeRC has developed and tested a unique method of accurately measuring these spinning acoustic modes generated by an experimental fan. This mode measuring method is based on the use of a rotating microphone rake. Testing was conducted in the 9 x 15 Low-speed Wind Tunnel. The rotating rake was tested with the Advanced Ducted Propeller (ADP) model. This memorandum discusses the design and performance of the motor/drive system for the fan-synchronized rotating acoustic rake. This novel motor/drive design approach is now being adapted for additional acoustic mode studies in new test rigs as baseline data for the future design of active noise control for subsonic fan engines. Included in this memorandum are the research requirements, motor/drive specifications, test performance results, and a description of the controls and software involved.

Konno, Kevin E.↗

NASA's program in lidar remote sensing

Several major NASA research efforts in lidar remote sensing are reviewed, with attention given to hardware and key sensor issues along with results and expectations. The discussion covers temperature and pressure measurements, measurements methods and instrumentation, pressure data, wind field measurements, atmospheric backscatter measurement, aerosol and cloud measurements, and water vapor measurement. Consideration is also given to the applicability of lidar measurements to problems of operational weather analysis and forecasting, climate studies, mesoscale and severe storm analysis and forecastig, and studies of atmosphere/surface interface.

Theon, John S.↗

Spectroscopic investigation of a low-power arcjet plume

We report the results of spectroscopic measurements on the exhaust plume from a 1 kW NASA Lewis arcjet operated on simulated ammonia. In particular, we analyze emissions from the Balmer lines of atomic hydrogen and from one of the rotational bands of the NH radical. We find that exit plane temperatures are in the range 2000 to 3500 K, depending on the measurement method, and that the electron density upstream of the exit plane is on the order of 1.5 x 10 exp 14/cu cm as determined by the Stark width of the Balmer-alpha line. Also, we have determined that the average velocity of atomic hydrogen at the exit plane is about 4 km/sec, and that strong acceleration (to 5.5 km/sec) of the flow occurs just beyond the exit plane.

Ruyten, W. M.↗

Pressure and temperature measurement in supercharger investigations

With the further development of the supercharger, requirements with regard to measuring accuracy increase while at the same time the conditions under which the measurements must be carried out become more difficult. The present paper is a contribution toward the improvement and refinement of the measuring methods. For pressure measurements some suggestions are made with regard to design and location of the measuring stations. The question of temperature measurement in rapid air flow is discussed, new instruments for the direct measurement of the temperature in the rapid airstream are described and the results obtained with the various instruments presented.

Franz, A↗

Experiments on a Slotted Wing

The results of pressure distribution measurements that were made on a model wing section of a Fieseler F 5 R type airplane are presented. Comparison of those model tests with the corresponding flight tests indicates the limitations and also the advantages of wind tunnel investigations, the advantages being particularly that through the variety of measuring methods employed the more complicated flow conditions may also be clarified. A fact brought out in these tests is that even in the case of "well rounded" slots it is possible for a vortex to be set up at the slot entrance and this vortex is responsible for certain irregularities in the pressure distribution and in the efficiency of the slot.

Ruden, P↗

Two color holographic interferometry for microgravity application

Holographic interferometry is a primary candidate for the measurement of temperature and concentration in various crystal growth experiments destined for space. The method measures refractive index changes in the experiment test cell. A refractive index change can be caused by concentration changes, temperature changes, or a combination of temperature and concentration changes. If the refractive index changes are caused by temperature and concentration changes occurring simultaneously in the experiment test cell, the contributions by the two effects cannot be separated by conventional measurement methods. By using two wavelengths, two independent interferograms can be produced from the reconstruction of the hologram. The two interferograms will be different due to dispersion properties of fluid materials. These differences provide the additional information that allows the separation of simultaneously occurring temperature and concentration gradients. There is no other technique available that can provide this type of information. The primary objectives of this effort are to experimentally verify the mathematical theory of two color holographic interferometry and to determine the practical value of this technique for space application. To achieve these objectives, the accuracy and sensitivity of the technique must be determined for geometry's and materials that are relevant to the Materials Processing in the Space program of NASA. This will be achieved through the use of a specially designed two-color holographic interferometry breadboard optical system. In addition to experiments to achieve the primary goals, the breadboard will also provide inputs to the design of an optimum space flight system.

Trolinger, James D.↗

Figures of merit for laser beam quality

It was shown how full-width at half maximum (FWHM), full-width at 1/e(sup 2) (FW1/e(sup 2)), Strehl ratio, and encircled energy figures of merit vary with different types of aberration and measurement methods. The array sampling method and the slit-scan method are examined in detail. Our irradiance in the exit pupil of the optical system is a simple gaussian. It was found that in general the slit-scan method and the array method do not yield the same result. The width measurements for the central lobe of the diffraction pattern are very insensitive to aberration.

Milster, T. D.↗

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan↗

Strain gage selection in loads equations using a genetic algorithm

Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

Source record↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Mark Tracking: Position/orientation measurements using 4-circle mark and its tracking experiments

Future space robots require position and orientation tracking with visual feedback control to track and capture floating objects and satellites. We developed a four-circle mark that is useful for this purpose. With this mark, four geometric center positions as feature points can be extracted from the mark by simple image processing. We also developed a position and orientation measurement method that uses the four feature points in our mark. The mark gave good enough image measurement accuracy to let space robots approach and contact objects. A visual feedback control system using this mark enabled a robot arm to track a target object accurately. The control system was able to tolerate a time delay of 2 seconds.

Kanda, Shinji↗

An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

Gregory, Gerald L.↗

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL↗

Researches on the Piston Ring

In internal combustion engines, steam engines, air compressors, and so forth, the piston ring plays an important role. Especially, the recent development of Diesel engines which require a high compression pressure for their working, makes, nowadays, the packing action of the piston ring far more important than ever. Though a number of papers have been published in regard to researches on the problem of the piston ring, none has yet dealt with an exact measurement of pressure exerted on the cylinder wall at any given point of the ring. The only paper that can be traced on this subject so far is Mr. Nakagawa's report on the determination of the relative distribution of pressure on the cylinder wall, but the measuring method adopted therein appears to need further consideration. No exact idea has yet been obtained as to how the obturation of gas between the piston and cylinder, the frictional resistance of the piston, and the wear of the cylinder wall are affected by the intensity and the distribution of the radial pressure of the piston ring. Consequently, the author has endeavored, by employing an apparatus of his own invention, to get an exact determination of the pressure distribution of the piston ring. By means of a newly devised ring tester, to which piezoelectricity of quartz was applied, the distribution of the radial pressure of many sample rings on the market was accurately determined. Since many famous piston rings show very irregular pressure distribution, the author investigated and achieved a manufacturing process of the piston ring which will exert uniform pressure on the cylinder wall. Temperature effects on the configuration and on the mean spring power have also been studied. Further, the tests were performed to ascertain how the gas tightness of the piston ring may be affected by the number or spring power. The researches as to the frictional resistance between the piston ring and the cylinder wall were carried out, too. The procedure of study, and experiments conducted by the author, on this subject will be fully described in the following paragraphs.

Ehihara, Keikiti↗

Software Reliability Measurement Experience

In this chapter, we describe a recent study of software reliability measurement methods that was conducted at the Jet Propulsion Laboratory. The first section of the chapter, sections 8.1, summarizes the study, characterizes the participating projects, describes the available data, and summarizes the tudy's results.

Software data execution-based early prediction↗

Detection of S02 and N02 in Stack Plume by Raman Scattering and Fluorescence

We have been studying laser-Raman radar which can be used as the remote detector of sulfur dioxide concentration in the stack plume of boiler exhaust gas, and some results have been published. In this paper, we report the interference of nitrogen dioxide fluorescence against sulfur dioxide Raman scattering and the measuring method of sulfur dioxide and nitrogen dioxide concentration. In a stack plume, high density dust and high concentration carbon dioxide are included, therefore very strong Mie back-scattering and carbon dioxide Raman scattering are observed. The separation of these scattering signals from sulfur dioxide Raman signal was the first problem for the laser-Raman radar. But, this problem was solved by using the filter which have high resolving power. It is well known that nitrogen dioxide can be excited to emit fluorescence of broad spectrum by blue-green light. The light source of the laser-Raman radar is SH of Nd:YAG laser, and boiler exhaust gas includes several tens ppm of nitrogen dioxide, then the interference of nitrogen dioxide fluorescence brings the error to sulfur dioxide measurement. 'rhe rejection of the interference can be achieved by the subtraction of the nitrogen dioxide fluorescence contribution from detected signal at sulfur dioxide Raman scattering wavelength. The nitrogen dioxide fluorescence contribution can be measured by two methods. The first is to convert the nitrogen dioxide fluorescence intensity which is measured at a different wavelength from sulfur dioxide Raman line into the one at sulfur dioxide Raman line. The second is to convert the detected signal intensity, which is obtained when the range gate is set just behind the plume, into the one obtained at the range of the plume using the difference of the time dependence between sulfur dioxide Raman scattering and nitrogen dioxide fluorescence. Nitrogen dioxide fluorescence has lifetime of about 300nS, while Raman scattering has none. By either of the two methods, the contribution of nitrogen dioxide fluorescence is determined. Then, we can measure the nitrogen dioxide and sulfur dioxide concentration.The minimum detectable concentration and the experimental results of the remote sensing of sulfur dioxide and nitrogen dioxide in stack plume will be discussed in detail.

Nakahara, S.↗