A New Modeling Approach for a Priori Uncertainties of Laser Tracker Angle Measurements

Methods for modeling the uncertainty in laser tracker angle measurements vary within the metrology industry, leading to confusion and questionable stochastic modeling for survey network adjustments and error propagation analysis. Interpreting the published laser tracker manufacturer performance specifications to determine an a priori sigma value for weighting azimuth and zenith angle measurements can be confusing and has led to differing implementations. Furthermore, this paper proposes a unique way to model survey network a priori laser tracker angular uncertainties based on laser tracker manufacturers’ published maximum permissible error (MPE) values referenced to current standards for weighting survey network measurements. This paper’s proposed model takes into account the disparate effects that pointing errors, target centering errors, and leveling errors have on azimuth and zenith angular uncertainties for measurements with steep sightings and at near ranges.

42 ENGINEERING↗

Calculating Interval Uncertainties for Calibration Standards That Drift with Time

Calibrated values of many devices exhibit predictable drift over time. To provide an uncertainty statement valid over the entire calibration interval, one must account for drift. In this article, a method of accounting for drift is proposed based on guidance in the Guide to Expression of Uncertainty in Measurement. An additional uncertainty term is computed using a linear regression of historical measurement data, which is included along with the time-of-test uncertainty. This method is evaluated by analyzing its average out-of-tolerance (OOT) rate using a Monte Carlo simulation, which results in the desired 5% average OOT rate when the total uncertainty is expanded to a 95% confidence interval.

47 OTHER INSTRUMENTATION↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Molecular structure determination: Equilibrium structure of pyrimidine (m-C 4 H 4 N 2 ) from rotational spectroscopy (reSE) and high-level ab initio calculation (re) agree within the uncertainty of experimental measurement

The pure rotational spectrum of pyrimidine (m-C 4 H 4 N 2 ), the meta-substituted dinitrogen analog of benzene, has been studied in the millimeter-wave region from 235 GHz to 360 GHz. The rotational spectrum of the ground vibrational state has been assigned and fit to yield accurate rotational and distortion constants. Over 1700 distinct transitions were identified for the normal isotopologue in its ground vibrational state and least-squares fit to a partial sextic S-reduced Hamiltonian. Transitions for all four singly substituted 13 C and 15 N isotopologues were observed at natural abundance and were likewise fit. Deuterium-enriched samples of pyrimidine were synthesized, giving access to all eleven possible deuterium-substituted isotopologues, ten of which were previously unreported. Experimental values of rotational constants and computed values of vibration–rotation interaction constants and electron-mass corrections were used to determine semi-experimental equilibrium structures (r e SE ) of pyrimidine. The r e SE structure obtained using coupled-cluster with single, double, and perturbative triple excitations [CCSD(T)] corrections shows exceptional agreement with the re structure computed at the CCSD(T)/cc-pCV5Z level (≤0.0002 Å in bond distance and ≤0.03° in bond angle). Of the various computational methods examined, CCSD(T)/cc-pCV5Z is the only method for which the computed value of each geometric parameter lies within the statistical experimental uncertainty (2σ) of the corresponding semi-experimental coordinate. The exceptionally high accuracy and precision of the structure determination is a consequence of the large number of isotopologues measured, the precision and extent of the experimental frequency measurements, and the sophisticated theoretical treatment of the effects of vibration–rotation coupling and electron mass. Taken together, these demanding experimental and computational studies establish the capabilities of modern structural analysis for a prototypical monocyclic aromatic compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Vertical Hydrologic Exchange Flow, Channel Flow, and Biogeochemical Kinetics on CH 4 Emissions From Rivers

Abstract CH 4 emissions from inland water are highly uncertain in the current global CH 4 budget, especially for rivers and streams due to sparse measurements and the uncertainty of measurements caused by turbulent water flow. A previous study has revealed that vertical hydrologic exchange flow (VHEF) is the main regulator of CH 4 emissions from riverbed sediments. However, to what extent the understanding obtained from the plot‐scale can be extended to the reach scale and basin scale remains unknown. To address this challenge, we developed a process‐based model to estimate CH 4 flux at the air‐water interface using the attributes available in the national hydrography data set. It calculates the annual mean flux of VHEF, CH 4 production in sediments, and CH 4 transport in the river channel in a sequential manner. Model performance is evaluated by CH 4 efflux observed at the Hanford reach of the Columbia River. We show that reach‐wise sediment hydrologic and biogeochemical conditions estimated from the national hydrography data set could serve as a good indicator of CH 4 emissions from rivers. Aerobic methane oxidation and export to the downstream are the dominant ways of total CH 4 loss for the large lowland river. The hotspots of CH 4 emissions are likely to be at the reaches with fine sediments and slow channel velocity. This study demonstrates the possibility of quantifying CH 4 emissions at the reach scale and the modeling framework has the potential to be extended to the basin scale to improve estimates of CH 4 emissions from lotic inland water.

58 GEOSCIENCES↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

A Reconfigurable Planar Capacitor Sensor for Thru the Jacket Dielectric Constant Measurement of Cable Insulation

Planar capacitor sensors have been proposed to measure the aging-related dielectric constant variation of the jacket or insulation materials of cables. Although capacitor sensors have been used to monitor the aging of cable insulation by removing the jacket, through the jacket measurement of cable insulation dielectric constant variation is difficult because once the sensor is placed on the jacket it would either measure the aging of the jacket or that of the jacket and insulation together. A reconfigurable sensor along with innovative cable-specific models could be used to determine the jacket and insulation aging using the same sensor. For the proposed novel reconfigurable sensor, the electric field penetration depth is changed by activating and deactivating PIN diode switches. In one instance, the sensor measures the dielectric constant variation of the jacket, while in the next, it measures the dielectric constant variation of both the jacket and the insulation. Here, by leveraging previously developed capacitance estimation models from large-scale finite element simulations for a specific cable, these two sets of measurement data are used to evaluate the aging-related dielectric constant variation of the insulation. Experimental data from aged cable specimens are presented to demonstrate the operation of the sensor.

47 OTHER INSTRUMENTATION↗

Sampling on NISQ Devices: "Who’s the Fairest One of All?"

Modern NISQ devices are subject to a variety of biases and sources of noise that degrade the solution quality of computations carried out on these devices. A natural question that arises in the NISQ era, is how fairly do these devices sample ground state solutions. To this end, we run five fair sampling problems (each with at least three ground state solutions) that are based both on quantum annealing and, on the Grover Mixer, -QAOA algorithm for gate-based NISQ hardware. In particular, we use seven IBM Q devices, the Aspen-9 Rigetti device, the IonQ device, and three D-Wave quantum annealers. For each of the fair sampling problems, we measure the ground state probability, the relative fairness of the frequency of each ground state solution with respect to the other ground state solutions, and the aggregate error as given by each hardware provider. Overall, our results show that NISQ devices do not achieve fair sampling yet. Furthermore, we also observe differences in the software stack with a particular focus on compilation techniques that illustrate what work will still need to be done to achieve a seamless integration of frontend (i.e., quantum circuit description) and backend compilation.

Computer Science↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty in Annual Energy Resulting from Uncertain Irradiance Measurements

We report an analysis quantifying the contribution to uncertainty in annual energy projections from uncertainty in ground-measured irradiance. Uncertainty in measured irradiance is quantified for eight instruments by the difference from a well maintained, secondary standard pyranometer which is regarded as truthful. We construct a statistical model of irradiance uncertainty and apply the model to generate a sample of 100 annual time series of irradiance for each instrument. The sample is propagated through a common performance model for a reference photovoltaic system to quantify variation in annual energy. Although the measured irradiance varies from the reference by a few percent (standard deviation of 1-2%) the uncertainty in annual energy is on the order of a fraction of one percent. We propose a model for a factor that represents uncertainty in modeled annual energy that arises from uncertainty in ground-measured irradiance.