Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Magnetic control systems for large spacecraft with applications to space telescope

Magnetic control systems for large space vehicles offer the advantage of a simple, reliable, low cost augmentation to the primary control system. When used for momentum management, a magnetic torque source offers a long life and noncontaminant environment when compared to a mass expulsion torque source. These qualities make such systems suitable for employment with the Space Telescope, which is a long life, high performance vehicle with optics and scientific instruments which would be degraded by contamination due to mass expulsion products. The various applications of magnetic systems on the Space Telescope are considered. The future trend in magnetic control of large space vehicles lies in providing a known three axis reference for backup operations, such as recovery of the primary control mode.

Dougherty, H.↗

Magnetized or Unmagnetized: Ambiguity Persists Following Galileo's Encounters with Io in 1999 and 2000

Magnetometer data from Galileo's close encounters with Io do not establish absolutely either the existence or absence of an internal magnetic moment because the measurements were made in regions where plasma currents contribute sizable magnetic perturbations. Data from an additional encounter where the closest approaches were made beneath Io's south polar regions, were lost. The recent passes enhance our understanding of the interaction of Io and its flux tube with the torus, and narrows the limits on possible internal sources of magnetic fields. Simple field-draping arguments account for some aspects of the observed rotations. Analyses in terms of both a magnetized and an unmagnetized Io are considered. Data from the February 2000 pass disqualify a strongly magnetized Io (surface equatorial field stronger than the background field) but do not disqualify a weakly magnetized Io (surface equatorial field of the order of Ganymede's but smaller than the background field at Io). Models imply that if Io is magnetized, its magnetic moment is not absolutely antialigned with the rotation axis. The inferred tilt is consistent with contributions from an inductive field on the order of those observed at Europa and Callisto. The currents would flow in the outer mantle or aesthenosphere if an induced field is present. Wave perturbations differing on flux tubes that do or do not link directly to Io and its ionosphere suggest the following: (1) the latter flux tubes are almost stagnant in Io's frame; and (2) a unipolar inductor correctly models the currents linking Io to Jupiter's ionosphere.

Kivelson, Margaret G.↗

Practical design of magnetic heading sensors

Although fluxgate magnetometers have been in use for many years, and a number of theoretical studies of these sensors are available, very little information has been published on the engineering choices relating to the detailed design of magnetometers intended for navigational applications in aircraft and other vehicles. This paper addresses some of the problems encountered in the design of the sensing head, the choice of operating mode, and the design of the supporting electronics for a simple low-cost magnetometer system which will produce a digital readout of the magnetic heading of the vehicle in which it is mounted. A major goal of this study has been to develop a design which minimizes circuit complexity, is easy to fabricate and calibrate, and utilizes a minimum of specialized components. Such a magnetometer system is intended either as a stand-alone indicating instrument or as a source of magnetic heading information for a more sophisticated navigational system.

Garner, H. D.↗

The generation of rolling moments with the superconducting solenoid model

The superconducting solenoid model is a pilot model core for levitation in a wind tunnel magnetic suspension system. This type of core would replace the ferromagnetic core typically installed in the model fuselage. For suspension purposes, the solenoid is operated upon by a set of electromagnets surrounding the wind tunnel which are to support and restrain the model at required positions and orientations under the influence of powerful aerodynamic disturbances. The subject of providing sources of magnets rolling moment for use when spanwise magnets, which can be used for winged models, are not available is covered. Several methods have emerged for generating a rolling moment based on the use of additional superconducting loops or magnetic poles positioned around or within the solenoid. Predictions of the moment capacities of superconducting loops in models sized for a large wind tunnel are presented. An existing prototype superconducting model proved a suitable vehicle for demonstrating and calibrating, at a smaller scale, some of the other roll elements based on magnetic pole devices. Calibration data are included.

Goodyear, M. J.↗

Magnetic edge fields in UTe 2 near zero background fields

Chiral superconductors are theorized to exhibit spontaneous edge currents. Here, in this study, we found magnetic fields at the edges of UTe 2 , a candidate odd-parity chiral superconductor, that seem to agree with predictions for a chiral order parameter. However, we did not detect the chiral domains that would be expected, and recent polar Kerr and muon spin relaxation data in nominally clean samples argue against chiral superconductivity. Our results show that hidden sources of magnetism must be carefully ruled out when using spontaneous edge currents to identify chiral superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large magnetic anisotropy of a decorated spin-chain system K 2 Co 3 (MoO 4 ) 3 (OH) 2

The magnetic structure of K 2 Co 3 (MoO 4 ) 3 (OH) 2 is studied in detail. The material has a half-sawtooth one-dimensional (1-D) structure containing two unique Co 2+ ions, one in the chain backbone and one on the apex of the sawtooth creating a series of isosceles triangles along the b-axis. These triangles can be a source of magnetic frustration. The ability to grow large single crystals enables detailed magnetic measurements with the crystals oriented in a magnetic field along the respective axes. It has a Curie–Weiss temperature θ CW of 5.3(2) K with an effective magnetic moment of 4.8(3)μ B /Co. The material is highly anisotropic with a sharp antiferromagnetic ordering transition at 7 K with a metamagnetic transition at 2 kOe. Neutron diffraction was used to determine the magnetic structure and revealed a magnetic structure with canted spins along the backbone of the chain while spins along the sawtooth caps maintained a colinear orientation, arranging antiferromagnetically relative to the backbone spins. In conclusion, the parallel chains arrange antiferromagnetically relative to each other along the c-axis and ferromagnetically along the a-axis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal coupling of Ho W 10 molecular magnets to superconducting circuits near spin clock transitions

A central goal in quantum technologies is to maximize GT 2 , where G stands for the coupling of a qubit to control and readout signals and T 2 is the qubit’s coherence time. Furthermore, this is challenging, as increasing G (e.g., by coupling the qubit more strongly to external stimuli) often leads to deleterious effects on T 2 . Here, we study the coupling of pure and magnetically diluted crystals of Ho W 10 magnetic clusters to microwave superconducting coplanar waveguides. Absorption lines give a broadband picture of the magnetic energy level scheme and, in particular, confirm the existence of level anticrossings at equidistant magnetic fields determined by the combination of crystal field and hyperfine interactions. Such “spin clock transitions” are known to shield the electronic spins against magnetic field fluctuations. The analysis of the microwave transmission shows that the spin-photon coupling also becomes maximum at these transitions. The results show that engineering spin-clock states of molecular systems offers a promising strategy to combine sizable spin-photon interactions with a sufficient isolation from unwanted magnetic noise sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic shielding of large high-power-satellite solar arrays using internal currents

Present concepts for solar power satellites involve dimensions up to tens of kilometers and operating internal currents up to hundreds of kiloamperes. A question addressed is whether the local magnetic fields generated by these strong currents during normal operation can shield the array against impacts by plasma ions and electrons (and from thruster plasmas) which can cause possible losses such as power leakage and surface erosion. One of several prototype concepts was modeled by a long narrow rectangular panel 2 km wide and 20 km long. The currents flow in a parallel across the narrow dimension (sheet current) and along the edge (wire currents). The wire currents accumulate from zero to 100 kiloamp and are the dominant sources. The magnetic field is approximated analytically. The equations of motion for charged particles in this magnetic field are analyzed. The ion and electron fluxes at points on the surface are represented analytically for monoenergetic distributions and are evaluated.

Parker, L. W.↗

Evaluation of riverbed magnetic susceptibility for mapping biogeochemical hot spots in groundwater‐impacted rivers

Abstract Redox hot spots occurring as metal‐rich anoxic groundwater discharges through oxic wetland and river sediments commonly result in the formation of iron (Fe) oxide precipitates. These redox‐sensitive precipitates influence the release of nutrients and metals to surface water and can act as ‘contaminant sponges’ by absorbing toxic compounds. We explore the feasibility of a non‐invasive, high‐resolution magnetic susceptibility (MS) technique to efficiently map the spatial variations of magnetic Fe oxide precipitates in the shallow bed of three rivers impacted by anoxic groundwater discharge. Laboratory analyses on Mashpee River (MA, USA) sediments demonstrate the sensitivity of MS to sediment Fe concentrations. Field surveys in the Mashpee and Quashnet rivers (MA, USA) reveal several discrete high MS zones, which are associated with likely anoxic groundwater discharge as evaluated by riverbed temperature, vertical head gradient, and groundwater chemistry measurements. In the East River (CO, USA), widespread cobbles/rocks exhibit high background MS from geological ferrimagnetic minerals, thereby obscuring the relatively small enhancement of MS from groundwater induced Fe oxide precipitates. Our study suggests that, in settings with low geological sources of magnetic minerals such as lowland rivers and wetlands, MS may serve as a complementary tool to temperature methods for efficiently mapping Fe oxide accumulation zones due to anoxic groundwater discharges that may function as biogeochemical hot spots and water quality control points in gaining systems.

Wang, Chen↗

Study of the performance of antennas in magnetized plasmas

The antenna studies were performed in a large magnetized plasma source, a schematic drawing of which is shown. The plasma diagnostics consist of a 70 GHz (4 mm) microwave interferometer for density measurements and of various Langmuir probes for spatially resolved measurements of t sub e, n sub e and the shape of the electron distribution function. All diagnostic data are time-resolved by sample-and-hold techniques so as to yield information about the plasma build-up, the steady-state discharge, and the plasma decay in the afterglow. Whistler waves are excited and detected with various antennas which are inserted into the center of the plasma column through one axial and two orthogonal radial ports. The antennas were tested for their proper dipole response and then calibrated in a known field geometry in air. For the electric dipole, a parallel plate capacitor field was used; the magnetic loop is calibrated in the near-zone field of a long linear conductor of known radio frequency current distribution. Results are presented and discussed.

Stenzel, R. L.↗

A violent interaction between the dwarf galaxy UGC 7636 and the giant elliptical galaxy NGC 4472

We present new U, B, R, and H I imagery of the Virgo Cluster giant elliptical galaxy NGC 4472 and its interacting dwarf companion galaxy UGC 7636. Using a composite image reconstruction technique, we show that a trail of debris approx. 5 arcmin in length and approx. 1 arcmin in width (30x6 kpc for a Virgo cluster distance of 20 Mpc) is projected northward from the dwarf galaxy. A cloud of H I is projected along the northwest edge of the debris between the dwarf and gE. The dwarf's nuclear morphology is irregular and bow-shaped on what appears to be its leading edge. Apart from a number of isolated blue regions, most of of the trailing debris is similar in color to the dwarf's nucleus. Only a modest enhancement of star formation appears to have been induced by the interaction. Although separated by 15 kpc, the H I and stellar morphologies are remarkably similar. The stars and H I appear to have been tidally distorted in situ, prior to the cloud's removal by ram pressure. If the H I has maintained its shape by magnetic support, a magnetic field strength an order of magnitude larger than the galaxy's is required. Ram pressure deceleration due to the cloud's motion through NGC 4472's x-ray-emitting interstellar medium shold be sufficient for the cloud to become gravitationally bound to NGC 4472. The H I cloud is not self-gravitating and may fragment and be destroyed in the interaction. UGC 7636 will probably be disrupted by NGC 4472's strong tidal forces; the stellar debris will disperse into the Virgo cluster or become bound to NGC 4472's halo on eccentric orbits. The debris captured in the collision will have a negligible impact on NGC 4472's stellar and gaseous content. On the other hand, if similar interactions are common in giant elliptical galaxies, they could alter or deplete surrounding dwarf galaxy populations, fuel bursts of nuclear activity, and perhaps provide a source of magnetic energy to their interstellar media.

Mcnamara, Brian R.↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Finite-difference multiple fluid solution for source-driven rotation in highly magnetized linear plasma device

The rotation profile of a magnetized plasma cylinder composed of multiple fluids is investigated analytically, expanding on previous results. The analytic steady-state solution is used as a benchmark for a time-dependent multiple-fluid finite-difference code, MITNS: Multiple-Ion Transport Numerical Solver. Magnetic field evolution is taken into account, both analytically and numerically. Its details are shown to be of importance when particles are allowed out of the domain. MITNS reproduces the asymptotic expansion results for a small parameter $δ<<<1$. For $\sqrt{m_elm_i} ~ δ << 1$ , a slightly different regime, dominated by viscosity-induced transport of ions, is found numerically and analytically. Finally, this verification supports the use of this code for more complex time-dependent calculations in the future. Additionally, we derive the angular velocity profile of each species due to radial particle and charge fluxes of various strengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpreting dynamic-compression experiments to uncover the time dependence of freezing: Application to gallium

Using pulsed-power magnetic field sources to compress gallium to gigapascal pressures on nanosecond timescales, we report here experiments on shockless dynamic compression of a liquid metal. Time-resolved velocimetry data reveal signatures of rapid freezing from a metastable liquid state, and we demonstrate that the kinetics of this nonequilibrium solidification can be accurately simulated with a computational modeling framework we have developed in previous studies, where classical nucleation theory is coupled with hydrodynamics. Notably, velocity traces in some of our experiments show evidence of a phase transition, while others do not, even though other types of evidence suggest that solidification may be occurring in all of them. We explain how predictions made by our models regarding the presence or absence of these phase-transition signatures motivated additional experiments that later confirmed the theoretical predictions. Our analysis shows that due to the rapid, quasi-isentropic nature of the loading path, our experiments were able to compress liquid gallium to metastable states that are undercooled below the equilibrium melt temperature by more than 300 K and exhibit pressures that approach five times the equilibrium melt pressure. The understanding gained in this study should form the basis for future dynamic-compression experiments aimed at interrogating melt curves at high pressures.

gallium↗

CHARACTERIZING AND CONTROLLING RECOVERY AND RECRYSTALLIZATION IN NIOBIUM FOR IMPROVED SRF CAVITY PERFORMANCE

Crystal defects, such as dislocations and low-angle boundaries, provide sources of magnetic flux trapping in the Nb materials used for superconducting radio frequency (SRF) resonating cavities. Improving the performance of SRF cavities, as measured through the quality factor, requires reducing these defects. SRF cavity production involves deformation processing, such as rolling and forming, and strategic annealing heat treatments. The resulting microstructures can be recovered, recrystallized, or both. Because recovery leaves many defects that can trap flux, recrystallization should improve cavity performance. Thus, processing schedules that produce complete recrystallization without excessive grain growth need to be designed. Solutions to this problem require understanding physical metallurgy and differentiating between recovered and recrystallized regions of microstructure. Backscattered electron microscopy techniques are applied to this end. We demonstrate that the conditions required to produce fully recrystallized microstructures depend on Nb impurity content, suggesting that processing schedules may need to be adjusted by material heat or lot. We also demonstrate that processing can be used to control growth of recrystallized grains to maintain mechanical strength in fully recrystallized materials. Forming cavities from cold-rolled Nb sheet material may provide strategic new routes to obtain microstructures that improve SRF cavity performance.

Taleff, E. [The University of Texas at Austin]↗

Metal whiskers

Metal whiskers - induced growth, growth mechanism, energy sources for growth, magnetic properties, and radiation effects

WHISKER↗