Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-F-T-575: Verification of a Monte-Carlo Small Field SRS/SBRT Dose Calculation System

Purpose: To develop a methodology for validation of a Monte-Carlo dose calculation model for robotic small field SRS/SBRT deliveries. Methods: In a robotic treatment planning system, a Monte-Carlo model was iteratively optimized to match with beam data. A two-part analysis was developed to verify this model. 1) The Monte-Carlo model was validated in a simulated water phantom versus a Ray-Tracing calculation on a single beam collimator-by-collimator calculation. 2) The Monte-Carlo model was validated to be accurate in the most challenging situation, lung, by acquiring in-phantom measurements. A plan was created and delivered in a CIRS lung phantom with film insert. Separately, plans were delivered in an in-house created lung phantom with a PinPoint chamber insert within a lung simulating material. For medium to large collimator sizes, a single beam was delivered to the phantom. For small size collimators (10, 12.5, and 15mm), a robotically delivered plan was created to generate a uniform dose field of irradiation over a 2×2cm{sup 2} area. Results: Dose differences in simulated water between Ray-Tracing and Monte-Carlo were all within 1% at dmax and deeper. Maximum dose differences occurred prior to dmax but were all within 3%. Film measurements in a lung phantom show high correspondence of over 95% gamma at the 2%/2mm level for Monte-Carlo. Ion chamber measurements for collimator sizes of 12.5mm and above were within 3% of Monte-Carlo calculated values. Uniform irradiation involving the 10mm collimator resulted in a dose difference of ∼8% for both Monte-Carlo and Ray-Tracing indicating that there may be limitations with the dose calculation. Conclusion: We have developed a methodology to validate a Monte-Carlo model by verifying that it matches in water and, separately, that it corresponds well in lung simulating materials. The Monte-Carlo model and algorithm tested may have more limited accuracy for 10mm fields and smaller.

60 APPLIED LIFE SCIENCES↗

SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11275105). Thanks for the support from Accuray Corp.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Techniques for Nuclear Systems - Theory Lectures

These are lecture notes for a Monte Carlo class given at the University of New Mexico. The following topics are covered: course information; nuclear eng. review & MC; random numbers and sampling; computational geometry; collision physics; tallies and statistics; eigenvalue calculations I; eigenvalue calculations II; eigenvalue calculations III; variance reduction; parallel Monte Carlo; parameter studies; fission matrix and higher eigenmodes; doppler broadening; Monte Carlo depletion; HTGR modeling; coupled MC and T/H calculations; fission energy deposition. Solving particle transport problems with the Monte Carlo method is simple - just simulate the particle behavior. The devil is in the details, however. These lectures provide a balanced approach to the theory and practice of Monte Carlo simulation codes. The first lectures provide an overview of Monte Carlo simulation methods, covering the transport equation, random sampling, computational geometry, collision physics, and statistics. The next lectures focus on the state-of-the-art in Monte Carlo criticality simulations, covering the theory of eigenvalue calculations, convergence analysis, dominance ratio calculations, bias in Keff and tallies, bias in uncertainties, a case study of a realistic calculation, and Wielandt acceleration techniques. The remaining lectures cover advanced topics, including HTGR modeling and stochastic geometry, temperature dependence, fission energy deposition, depletion calculations, parallel calculations, and parameter studies. This portion of the class focuses on using MCNP to perform criticality calculations for reactor physics and criticality safety applications. It is an intermediate level class, intended for those with at least some familiarity with MCNP. Class examples provide hands-on experience at running the code, plotting both geometry and results, and understanding the code output. The class includes lectures & hands-on computer use for a variety of Monte Carlo calculations. Beginning MCNP users are encouraged to review LA-UR-09-00380, "Criticality Calculations with MCNP: A Primer (3nd Edition)" (available at http:// mcnp.lanl.gov under "Reference Collection") prior to the class. No Monte Carlo class can be complete without having students write their own simple Monte Carlo routines for basic random sampling, use of the random number generator, and simplified particle transport simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Data Uncertainty Quantification for Adjoint-Weighted Quantities via XGPT in Monte Carlo Codes

The Total Monte Carlo method (TMC) is an innovative approach to nuclear data uncertainty propagation. In TMC, a large number of independent ENDF files are randomly generated starting from nuclear models parameters and their uncertainties. These files are then processed with NJOY or similar codes to produce a set of formatted continuous-energy cross sections (i.e., ACE files), and independent Monte Carlo neutron transport simulations are run with these different ACE files as input. Finally the distributions of the considered response functions are obtained directly from the results of the Monte Carlo runs. Despite several improvements of the TMC method, this approach is often considered an inefficient way of propagating nuclear data uncertainties, as it requires several computationally expensive Monte Carlo runs. Covariance-based methods present important advantages for several applications, especially when different sources of uncertainties are to be investigated. For this reason, sensitivity analysis and uncertainty quantification capabilities are being implemented in several Monte Carlo neutron transport codes. On the other hand, the fact that no artificial multi-group covariance matrices are required and that higher moments of the responses distributions can be easily obtained, are definite advantages of the TMC method. In an effort to overcome the limitations of both approaches, a new method, called eXtended Generalized Perturbation Theory (XGPT) is under development. When performing nuclear data uncertainty propagation, such XGPT approach does not require generating discretized (i.e., multigroup) covariance matrices, and allows to estimate higher moments of the response probability distributions, via linear perturbation theory. One of the promising applications of the XGPT method involves its adoption in conjunction with the Proper Orthogonal Decomposition (POD) of nuclear data, to build a Reduced Order Model (ROM) for the approximation of thousands of independent TMC results in a single criticality source simulation. In the present work, this approach is employed for the first time to evaluate the impact of uncertainty in nuclear data on adjoint-weighted quantities. The method has been implemented in an extended version of the Serpent-2.1.24 Monte Carlo code and is demonstrated on two fast spectrum benchmarks, focusing on {sup 208}Pb nuclear data. A new method for propagating nuclear data uncertainties in criticality source Monte Carlo simulations has been developed. This eXtended Generalized Perturbation Theory (XGPT) approach allows to accurately reproduce reference Total Monte Carlo (TMC) uncertainty estimates in a single criticality source simulation. The present work aims to demonstrate that the proposed method can quantify nuclear data uncertainty based on adjoint-weighted quantities. The XGPT approach was applied to evaluate the impact of {sup 208}Pb nuclear data uncertainties on the effective prompt neutron lifetime (l{sub eff}) in two fast spectrum systems. The obtained XGPT results show a good agreement with the reference TMC results, obtained from independent Monte Carlo runs with {sup 208}Pb nuclear data from random TENDL-2013 evaluations. The XGPT method, implemented in a extended version of the Serpent Monte Carlo code and adopted along with the Proper Orthogonal Decomposition (POD) of the nuclear data, is able to provide an accurate reduced order model to approximate thousands TMC results within a single run, ensuring a large saving in computational requirements. The effect of {sup 208}Pb nuclear data uncertainties appears to be rather large. This is consistent with previous studies that adopted the same input random evaluations data from TENDL. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Portable Event-Based Monte Carlo Transport Using the NVIDIA Thrust Library

Power consumption considerations are driving future high performance computing platforms toward many-core computing architectures. Los Alamos National Laboratory's Trinity machine, available in 2016, will use both Intel Xeon Haswell processors and Intel Xeon Phi Knights Landing many integrated core (MIC) architecture coprocessors. Lawrence Livermore National Laboratory's Sierra machine, available in 2018, will use an IBM PowerPC architecture along with Nvidia graphics processing unit (GPU) architecture accelerators. These different advanced architectures make the computing landscape in upcoming years complex. Traditional approaches to Monte Carlo transport do not work efficiently on these new computing platforms. MIC architectures require vectorization to operate efficiently, and vectorization is difficult to achieve in Monte Carlo transport. GPU architectures require additional code to explicitly use the hardware, requiring significant code changes or hardware specific branches in the source code. A significant challenge for Monte Carlo transport projects is to simultaneously support within a single source code base efficient simulations for both the current generation of architectures and the different advanced computing architectures. In order to address these challenges, two important changes are typically required: a new algorithmic approach for solving Monte Carlo transport, and explicit use of hardware specific software. In this paper, we describe initial research investigations of an event-based Monte Carlo transport algorithm implemented using the Nvidia Thrust library on a GPU for a Monte Carlo test code. The event-based algorithm targets many-core architectures by increasing SIMD (single instruction multiple data) parallelism, while Thrust potentially provides portable performance by allowing one source code base to compile code targeted for both CPUs and GPUs. We described preliminary investigations of portable event-based Monte Carlo algorithms implemented using the Nvidia Thrust library in a research Monte Carlo test code. We found that an explicit CUDA implementation of an event-based Monte Carlo algorithm performed significantly more efficiently than a Thrust implementation on GPU platforms, most likely as a result of additional flexibility in access to different memory spaces on the GPU. Additionally, we showed that on GPU platforms and at large enough problem sizes the event-based implementations perform more efficiently than the serial history-based implementation running on the host CPU. While investigating this problem, we also discovered that the performance of the event-based algorithm is affected by what tallies are being used. A zonal scalar flux tally requires atomic operations that significantly impacted the performance of the code, in some cases producing slowdowns instead of speedups. We decided to remove the tally in order to focus on the effectiveness of the event-based algorithm. Future work will be required to research more effective ways of handling such tallies. Additionally, we would like to consider new ways for optimizing both the Thrust and CUDA versions, in order to see how much performance we have yet to achieve. The potential trade-off between portability and performance was demonstrated in this investigation. Thrust provides both CPU and GPU versions of the code in one code base, but it does so at a cost. We discovered approximately a factor of 2-5 performance difference between Thrust and CUDA on each GPU platform we tested. Thrust provides a tool to access the GPUs with less effort and specialization, but it does so by giving up fine grained control where extra performance can be found for this application. Future work will be required to determine whether this performance differential between Thrust and CUDA can be reduced for event-based Monte Carlo transport. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient Subset Simulation using Hamiltonian Neural Network enhanced Markov Chain Monte Carlo Methods

The Monte Carlo method delivers an unbiased estimate of the probability of failure. However, the variance of the estimate depends on the number of evaluated samples. This number must be very large for estimations of a low probability of failure. If the evaluation of each sample is computationally expensive, the crude Monte Carlo simulation strategy is impracticable. Therefore, subset simulations are used to reduce the required number of evaluations. Subset simulations require a Markov Chain Monte Carlo sampler, such as the random walk Metropolis-Hastings algorithm. The algorithm, however, struggles with sampling in low-probability regions, especially if they are narrow. As a consequence, advanced Markov Chain Monte Carlo simulations have been developed. In particular, the Hamiltonian Monte Carlo method explores the target distribution rapidly. Driven by the idea of Hamiltonian dynamics, this sampler provides a non-random walk through the target distribution. The incorporation of subset simulation and Hamiltonian Monte Carlo methods has shown promising results for reliability analysis. One downside of the Hamiltonian Monte Carlo method is that gradient evaluations are computationally expensive, especially when dealing with high-dimensional problems and evaluating long trajectories. We show that integrating Hamiltonian neural networks in Hamiltonian Monte Carlo simulations significantly speeds up the sampling task. Furthermore, the enhancement of adaptive trajectory length within the Hamiltonian Monte Carlo results in the efficient proposal of the following states. Based on this recent enhancement, we provide a fast sampling strategy for subset simulations using Hamiltonian neural networks to replace the evaluation of the gradient and significantly speed up the Hamiltonian Monte Carlo simulation.

97 MATHEMATICS AND COMPUTING↗

A Hybrid Monte Carlo-Deterministic Method for Global Binary Stochastic Medium Transport Problems

Global deep-penetration transport problems are difficult to solve using traditional Monte Carlo techniques. In these problems, the scalar flux distribution is desired at all points in the spatial domain (global nature), and the scalar flux typically drops by several orders of magnitude across the problem (deep-penetration nature). As a result, few particle histories may reach certain regions of the domain, producing a relatively large variance in tallies in those regions. Implicit capture (also known as survival biasing or absorption suppression) can be used to increase the efficiency of the Monte Carlo transport algorithm to some degree. A hybrid Monte Carlo-deterministic technique has previously been developed by Cooper and Larsen to reduce variance in global problems by distributing particles more evenly throughout the spatial domain. This hybrid method uses an approximate deterministic estimate of the forward scalar flux distribution to automatically generate weight windows for the Monte Carlo transport simulation, avoiding the necessity for the code user to specify the weight window parameters. In a binary stochastic medium, the material properties at a given spatial location are known only statistically. The most common approach to solving particle transport problems involving binary stochastic media is to use the atomic mix (AM) approximation in which the transport problem is solved using ensemble-averaged material properties. The most ubiquitous deterministic model developed specifically for solving binary stochastic media transport problems is the Levermore-Pomraning (L-P) model. Zimmerman and Adams proposed a Monte Carlo algorithm (Algorithm A) that solves the Levermore-Pomraning equations and another Monte Carlo algorithm (Algorithm B) that is more accurate as a result of improved local material realization modeling. Recent benchmark studies have shown that Algorithm B is often significantly more accurate than Algorithm A (and therefore the L-P model) for deep penetration problems such as examined in this paper. In this research, we investigate the application of a variant of the hybrid Monte Carlo-deterministic method proposed by Cooper and Larsen to global deep penetration problems involving binary stochastic media. To our knowledge, hybrid Monte Carlo-deterministic methods have not previously been applied to problems involving a stochastic medium. We investigate two approaches for computing the approximate deterministic estimate of the forward scalar flux distribution used to automatically generate the weight windows. The first approach uses the atomic mix approximation to the binary stochastic medium transport problem and a low-order discrete ordinates angular approximation. The second approach uses the Levermore-Pomraning model for the binary stochastic medium transport problem and a low-order discrete ordinates angular approximation. In both cases, we use Monte Carlo Algorithm B with weight windows automatically generated from the approximate forward scalar flux distribution to obtain the solution of the transport problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-35: An Investigation of the Accuracy of Cervical IMRT Dose Distribution Using 2D/3D Ionization Chamber Arrays System and Monte Carlo Simulation

Purpose: The purpose of this work is to compare the verification results of three solutions (2D/3D ionization chamber arrays measurement and Monte Carlo simulation), the results will help make a clinical decision as how to do our cervical IMRT verification. Methods: Seven cervical cases were planned with Pinnacle 8.0m to meet the clinical acceptance criteria. The plans were recalculated in the Matrixx and Delta4 phantom with the accurate plans parameters. The plans were also recalculated by Monte Carlo using leaf sequences and MUs for individual plans of every patient, Matrixx and Delta4 phantom. All plans of Matrixx and Delta4 phantom were delivered and measured. The dose distribution of iso slice, dose profiles, gamma maps of every beam were used to evaluate the agreement. Dose-volume histograms were also compared. Results: The dose distribution of iso slice and dose profiles from Pinnacle calculation were in agreement with the Monte Carlo simulation, Matrixx and Delta4 measurement. A 95.2%/91.3% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Pinnacle distributions within 3mm/3% gamma criteria. A 96.4%/95.6% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Monte Carlo simulation within 2mm/2% gamma criteria, almost 100% gamma pass ratio within 3mm/3% gamma criteria. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusion: It was shown that Matrixx/Delta4 and Monte Carlo simulation can be used very efficiently to verify cervical IMRT delivery. In terms of Gamma value the pass ratio of Matrixx was little higher, however, Delta4 showed more problem fields. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-T-546: Modeling and Validation of the a New Proton Therapy System Using a Monte-Carlo Environment Optimized for Protons

8 particle histories were run. Results: Range measurements of the Monte-Carlo simulations matched the measured data within 1mm. Distal fall-off of the simulated fields matched within <1mm. Lateral penumbra and field size measurements of the standard-sized square and half-beam blocked fields matched within 1mm at all three planes compared. A small difference was seen in the in-air profiles at doses <0%. The suspected cause of the difference was the aperture shape. The measured data utilized a divergent aperture. The Monte-Carlo calculation used a non-divergent aperture. Conclusion: The validation measurements indicate that we were able to accurately model the MEVION s250 Proton therapy system using Monte-Carlo Calculations. This may reduce the commissioning time for future users. Purpose: Monte-Carlo modeling is an important tool for understanding the behavior of therapeutic proton beams in a heterogeneous media such as the patient. To gain confidence that a Monte-Carlo model is accurate in complex geometries and media, it must first be compared with measurement in simple situations. This study documents the validation of our Monte-Carlo Model. Methods: A model of the MEVION s250 Proton therapy system was created in the TOPAS Monte-Carlo environment using machine geometry and field shaping system information provided by the vendor. For each of 24 options, validation of the TOPAS model was performed by comparing the dose scored by TOPAS to the dose measurements obtained during the commissioning of the treatment planning system. The measurements compared consisted of: pristine peak depth-dose profiles, in-air profiles for a standard-sized square field (20cm×20cm or 10cm×10cm depending on the maximum field size for each option) at isocenter and at 20cm upstream and downstream of isocenter, and in-air profiles with a half-beam blocked aperture at isocenter and at 20cm upstream and downstream of isocenter. For all Monte-Carlo simulations,.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo Estimates of Eigenvalue Sensitivity to System Dimensions using Kernel Density Estimators

In the last decade there has been an increasing interest in calculating sensitivity coefficients in order to quantify the impact of uncertainty in material properties and system parameters on quantities of interest. Extensive work has been done developing Monte Carlo methods to estimate eigenvalue sensitivity to material properties. While deterministic methods exist for determining the eigenvalue sensitivity to system dimensions, the use of Monte Carlo methods to efficiently calculate eigenvalue sensitivity coefficients to system dimensions is still an open topic. Current Monte Carlo methods for calculating eigenvalue sensitivity coefficients to system dimensions are inefficient. Direct Monte Carlo perturbations require two additional simulations of high statistical precision in order to determine the eigenvalue sensitivity to the location of a single boundary. If the sensitivity to the location of multiple surfaces are desired, two additional simulations must be run for each surface. Kiedrowski and Favorite extended continuous energy Monte Carlo methods for sensitivities of nuclear cross sections to calculate sensitivities to interface boundaries or system dimensions to create the only current alternative to direct Monte Carlo calculations. However this method relies on the simulation of additional random walks launched at each surface crossing event. The present method extends upon Kiedrowski's work and eliminates the inefficient portions of the calculation through the use of Kernel Density Estimators (KDEs). The new method efficiently estimates eigenvalue sensitivities to the uniform expansion or contraction of material interface boundaries or system dimensions, negligibly impacting the runtime performance of the Monte Carlo code. The new estimator is tested on bare and reflected critical configurations in spherical geometry and is compared to estimates obtained from direct Monte Carlo perturbations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RASPA3

RASPA3, a molecular simulation code for computing adsorption and diffusion in nanoporous materials and thermodynamic and transport properties of fluids. It implements force field based classical Monte Carlo/molecular dynamics in various ensembles. RASPA3 is rewritten from the ground up in C++23 with speed and code readability in mind. Transition-matrix Monte Carlo is added to compute the density of states and free energies. The Monte Carlo code for rigid molecules is based on quaternions, and the atomic positions needed in the energy evaluation are recreated from the center of mass position and quaternion orientation. The expanded ensemble methodology for fractional molecules, with a scaling parameter λ between 0 and 1, now also keeps track of analytic expressions of dU/dλ, allowing independent verification of the chemical potential using thermodynamic integration. The source code is freely available under the MIT license on GitHub.

Dubbeldam, David↗

The X-43A Six Degree of Freedom Monte Carlo Analysis

This report provides an overview of the Hyper-X research vehicle Monte Carlo analysis conducted with the six-degree-of-freedom simulation. The methodology and model uncertainties used for the Monte Carlo analysis are presented as permitted. In addition, the process used to select hardware validation test cases from the Monte Carlo data is described. The preflight Monte Carlo analysis indicated that the X-43A control system was robust to the preflight uncertainties and provided the Hyper-X project an important indication that the vehicle would likely be successful in accomplishing the mission objectives. The X-43A in-flight performance is compared to the preflight Monte Carlo predictions and shown to exceed the Monte Carlo bounds in several instances. Possible modeling shortfalls are presented that may account for these discrepancies. The flight control laws and guidance algorithms were robust enough as a result of the preflight Monte Carlo analysis that the unexpected in-flight performance did not have undue consequences. Modeling and Monte Carlo analysis lessons learned are presented.

Baumann, Ethan↗

The X-43A Six Degree of Freedom Monte Carlo Analysis

This report provides an overview of the Hyper-X research vehicle Monte Carlo analysis conducted with the six-degree-of-freedom simulation. The methodology and model uncertainties used for the Monte Carlo analysis are presented as permitted. In addition, the process used to select hardware validation test cases from the Monte Carlo data is described. The preflight Monte Carlo analysis indicated that the X-43A control system was robust to the preflight uncertainties and provided the Hyper-X project an important indication that the vehicle would likely be successful in accomplishing the mission objectives. The X-43A inflight performance is compared to the preflight Monte Carlo predictions and shown to exceed the Monte Carlo bounds in several instances. Possible modeling shortfalls are presented that may account for these discrepancies. The flight control laws and guidance algorithms were robust enough as a result of the preflight Monte Carlo analysis that the unexpected in-flight performance did not have undue consequences. Modeling and Monte Carlo analysis lessons learned are presented.

Baumann, Ethan↗

Development of Monte Carlo Capability for Orion Parachute Simulations

Parachute test programs employ Monte Carlo simulation techniques to plan testing and make critical decisions related to parachute loads, rate-of-descent, or other parameters. This paper describes the development and use of a MATLAB-based Monte Carlo tool for three parachute drop test simulations currently used by NASA. The Decelerator System Simulation (DSS) is a legacy 6 Degree-of-Freedom (DOF) simulation used to predict parachute loads and descent trajectories. The Decelerator System Simulation Application (DSSA) is a 6-DOF simulation that is well suited for modeling aircraft extraction and descent of pallet-like test vehicles. The Drop Test Vehicle Simulation (DTVSim) is a 2-DOF trajectory simulation that is convenient for quick turn-around analysis tasks. These three tools have significantly different software architectures and do not share common input files or output data structures. Separate Monte Carlo tools were initially developed for each simulation. A recently-developed simulation output structure enables the use of the more sophisticated DSSA Monte Carlo tool with any of the core-simulations. The task of configuring the inputs for the nominal simulation is left to the existing tools. Once the nominal simulation is configured, the Monte Carlo tool perturbs the input set according to dispersion rules created by the analyst. These rules define the statistical distribution and parameters to be applied to each simulation input. Individual dispersed parameters are combined to create a dispersed set of simulation inputs. The Monte Carlo tool repeatedly executes the core-simulation with the dispersed inputs and stores the results for analysis. The analyst may define conditions on one or more output parameters at which to collect data slices. The tool provides a versatile interface for reviewing output of large Monte Carlo data sets while preserving the capability for detailed examination of individual dispersed trajectories. The Monte Carlo tool described in this paper has proven useful in planning several Crew Exploration Vehicle parachute tests.

Moore, James W.↗

Transport error estimation using residual Monte Carlo

The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗