Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MINNESOTA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Use of Landsat data to predict the trophic state of Minnesota lakes

Near-concurrent Landsat Multispectral Scanner (MSS) and ground data were obtained for 60 lakes distributed in two Landsat scene areas. The ground data included measurement of secchi disk depth, chlorophyll-a, total phosphorous, turbidity, color, and total nitrogen, as well as Carlson Trophic State Index (TSI) values derived from the first three parameters. The Landsat data best correlated with the TSI values. Prediction models were developed to classify some 100 'test' lakes appearing in the two analysis scenes on the basis of TSI estimates. Clouds, wind, poor image data, small lake size, and shallow lake depth caused some problems in lake TSI prediction. Overall, however, the Landsat-predicted TSI estimates were judged to be very reliable for the secchi-derived TSI estimation, moderately reliable for prediction of the chlorophyll-a TSI, and unreliable for the phosphorous value. Numerous Landsat data extraction procedures were compared, and the success of the Landsat TSI prediction models was a strong function of the procedure employed.

Lillesand, T. M.↗

Nonparametric analysis of Minnesota spruce and aspen tree data and LANDSAT data

The application of nonparametric methods in data-intensive problems faced by NASA is described. The theoretical development of efficient multivariate density estimators and the novel use of color graphics workstations are reviewed. The use of nonparametric density estimates for data representation and for Bayesian classification are described and illustrated. Progress in building a data analysis system in a workstation environment is reviewed and preliminary runs presented.

Scott, D. W.↗

Correlations and contrasts in structural history and style between an Archaean greenstone belt and adjacent gneiss belt, NE Minnesota

An analysis of the deformation along the boundary between the Vermilion Granitic Complex (VGC) and the Vermilion district indicates that the two terranes have seen a similar deformation history since the earliest stages of folding in the area. Despite this common history, variations in structural style occur between the two terranes, such as the relative development of D sub 1 fabrics and D sub 2 shear zones, and these can be attributed to differences in the crustal levels of the two terranes during the deformation. Similarly, the local development of F sub 3 folds in the VGC, but not in the Vermilion district, is interpreted to be a result of later-D sub 2 pluton emplacement which was not significant at the level of exposure of ther Vermilion district.

Bauer, R. L.↗

Transpression as the main deformational event in an Archaean greenstone belt, northeastern Minnesota

Deformed and metamorphosed sedimentary and volcanic rocks of the Vermilion district constitute an Archean greenstone belt trending east-west between higher grade rocks of the Vermilion Granitic Complex to the north and the Giants Range batholith to the south. Metamorphic grade is low throughout, being lowest in the center of the belt (chlorite zone of the greenschist facies). All the measured strain, a cleavage or schistosity, and a mineral lineation in this belt are attributed to the main phase of deformation D sub 2 that followed an earlier nappe-forming event D sub 1, which left little evidence of penetrative fabric. Previous work assumed that the D sub 2 deformation resulted from north-south compression across the district. It is now believed that a significant component of this deformation resulted from dextral shear across the whole region. Thus the Vermilion fault, a late-state largely strike-slip structure that bounds the Vermilion district to the north, may simply be the latest, most brittle expression of a shear regime that was much more widespread in space and time. Features that are indicative of shear include ductile shear zones with sigmoidal foliation patterns, highly schistose zones with the development of shear bands, feldspar clasts or pyrite cubes with asymmetric pressure shadows, and the fact that the asymmetry of the F sub 2 folds is predominantly Z for at least 15 km south of the Vermilion fault.

Hudleston, P. J.↗

Separability of boreal forest species in the Lake Jennette area, Minnesota

In order to exploit the use of thematic mapper (TM) data to obtain vegetation and net primary productivity maps in the boreal forest, three aircraft flights were undertaken over the area near Ely, MN, with the NS 001 Thematic Mapper Simulator. Attention is presently given to an analysis of these 1983 data, which attempted to separate coniferous trees from deciduous ones. Canopy reflectance models and measured optical properties of the scattering elements have been used to deepen understanding of this separability, and to relate the ratio of nadir view reflectances in TM bands 4 and 3 to the overstory leaf area index. A map that is proportional to the leaf area index for deciduous species is presented.

Shen, S. S.↗

The University of Minnesota oscillating flow experiments

Hot-wire anemometry techniques used to document laminar-to-turbulent transition in oscillating flow are discussed, and two transition mechanisms proposed by Seume (1988) are reviewed. Reliable near-wall data, and the convergence of ensemble-averaged velocities and rms velocity fluctuations will aid in evaluating wall shear stresses and calculating various boundary-layer parameters. Special consideration was given to a detailed measurement program which documents transition at different axial positions for the space power research engine (SPRE) operating point. Future work on the effect of entry geometry and measurements of heat transfer are outlined. In order to better simulate flow conditions in actual Stirling engine heat exchangers, the effects of various inflow geometries are investigated. Once the hydrodynamic conditions in the test section are documented, a measurement program to assess the effect of flow oscillation on heat transfer will commence.

Friedman, G. T.↗

Building America Case Study: Cold Climate Foundation Wall Hygrothermal Research Facility, Cloquet, Minnesota (Fact Sheet)

This report focuses on the progress made to date and the technical details of the experiment. An overview of the experimental data being collected with some interesting highlights noted thus far is also provided. A full analysis of the experimental data and the drawing of conclusions with regard to the thermal and hygrothermal performance of the retrofit foundation insulation systems tested will only be possible after a full year of data has been collected in 2014.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Excavationless Exterior-Side Foundation Insulation for Existing Homes, Minneapolis, Minnesota (Fact Sheet)

Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. The team was able to excavate a continuous 4" wide by 4' to 5' deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Advanced Controls Improve Performance of Combination Space and Water Heating Systems, Minneapolis, Minnesota

The combined space and water heating systems (combi) uses a high efficiency direct vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that utilizing condensing water heaters or boilers with hydronic air handlers can provide both space and water heating with efficiencies of 90% or greater. Improved controls have the potential to reduce some of this complexity and boost the measured performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Durable Interior Foundation Insulation Retrofits for Cold Climates, Cloquet, Minnesota

Thermal and moisture problems in existing basements create a unique challenge as the exterior face of the wall is not easily or inexpensively accessible. This approach by the NorthernSTAR Building America Partnership team addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. It is effective at reducing energy loss through the wall principally during the heating season. The team conducted experiments at the Cloquet Residential Research Facility to test the heat and moisture performance of four hollow masonry block wall systems and two rim-joist systems. These systems were retrofitted with interior insulation in compliance with the 2012 IECC. The research showed for the first time that, for masonry block walls in a cold climate, a solid bond beam or equivalent provides adequate resistance to moisture transport from a hollow core to the rim-joist cavity. Thus, a solid top course is a minimum requirement for an interior retrofit insulation system.

BASEMENT↗