Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Air jet levitation furnace system for observing glass microspheres during heating and melting

A collimated hole structure air jet levitation system has been developed which can be used to levitate hollow glass microspheres used in inertial confinement fusion studies. An ellipsoidal furnace has been added to the system to provide a heating source. A video camera and a 16 mm movie camera connected to a microsphere system provide real time observation as well as permanent documentation of the experiments. Microspheres have been levitated at temperatures over 1400 C for over 10 minutes at a time.

Ethridge, E. C.↗

Filling Porous Microspheres With Magnetic Material

New process produces magnetic microspheres with controllable sizes, compositions, and properties for use in medical diagnostic tests, biological research, and chemical processes. Paramagnetic microspheres also made with process. Porous plastic microspheres prepared by polymerization of monomer in diluent by cross-linking agent. When diluent removed, it leaves tiny pores throughout polymerized spheres. Size and distribution of pores determined by amount and type of diluent and cross-linking agent.

Chang, Manchium↗

Glass microsphere lubrication

The harsh lunar environment eliminated the consideration of most lubricants used on earth. Considering that the majority of the surface of the moon consists of sand, the elements that make up this mixture were analyzed. According to previous space missions, a large portion of the moon's surface is made up of fine grained crystalline rock, about 0.02 to 0.05 mm in size. These fine grained particles can be divided into four groups: lunar rock fragments, glasses, agglutinates (rock particles, crystals, or glasses), and fragments of meteorite material (rare). Analysis of the soil obtained from the missions has given chemical compositions of its materials. It is about 53 to 63 percent oxygen, 16 to 22 percent silicon, 10 to 16 percent sulfur, 5 to 9 percent aluminum, and has lesser amounts of magnesium, carbon, and sodium. To be self-supporting, the lubricant must utilize one or more of the above elements. Considering that the element must be easy to extract and readily manipulated, silicon or glass was the most logical choice. Being a ceramic, glass has a high strength and excellent resistance to temperature. The glass would also not contaminate the environment as it comes directly from it. If sand entered a bearing lubricated with grease, the lubricant would eventually fail and the shaft would bind, causing damage to the system. In a bearing lubricated with a solid glass lubricant, sand would be ground up and have little effect on the system. The next issue was what shape to form the glass in. Solid glass spheres was the only logical choice. The strength of the glass and its endurance would be optimal in this form. To behave as an effective lubricant, the diameter of the spheres would have to be very small, on the order of hundreds of microns or less. This would allow smaller clearances between the bearing and the shaft, and less material would be needed. The production of glass microspheres was divided into two parts, production and sorting. Production includes the manufacturing of the microspheres, while sorting entails deciphering the good microspheres from the bad ones. Each process is discussed in detail.

Geiger, Michelle↗

Beat frequency ultrasonic microsphere contrast agent detection system

A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

Pretlow, Robert A., III↗

Protein specific fluorescent microspheres for labelling a protein

Highly fluorescent, stable and biocompatible microspheres are obtained by copolymerizing an acrylic monomer containing a covalent bonding group such as hydroxyl, amine or carboxyl, for example, hydroxyethylmethacrylate, with an addition polymerizable fluorescent comonomer such as dansyl allyl amine. A lectin or antibody is bound to the covalent site to provide cell specificity. When the microspheres are added to a cell suspension the marked microspheres will specifically label a cell membrane by binding to a specific receptor site thereon. The labeled membrane can then be detected by fluorescence of the fluorescent monomer.

Rembaum, Alan↗

Beat frequency ultrasonic microsphere contrast agent detection system

A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

Pretlow, III, Robert A.↗

Microsphere coated substrate containing reactive aldehyde groups

A synthetic organic resin is coated with a continuous layer of contiguous, tangential, individual microspheres having a uniform diameter preferably between 100 Angstroms and 2000 Angstroms. The microspheres are an addition polymerized polymer of an unsaturated aldehyde containing 4 to 20 carbon atoms and are covalently bonded to the substrate by means of high energy radiation grafting. The microspheres contain reactive aldehyde groups and can form conjugates with proteins such as enzymes or other aldehyde reactive materials.

Rembaum, Alan↗

Polyacrolein microspheres

Microspheres of acrolein homopolymers and co-polymer with hydrophillic comonomers such as methacrylic acid and/or hydroxyethylmethacrylate are prepared by cobalt gamma irradiation of dilute aqueous solutions of the monomers in presence of suspending agents, especially alkyl sulfates such as sodium dodecyl sulfate. Amine or hydroxyl modification is achieved by forming adducts with diamines or alkanol amines. Carboxyl modification is effected by oxidation with peroxides. Pharmaceuticals or other aldehyde reactive materials can be coupled to the microspheres. The microspheres directly form antibody adducts without agglomeration.

Rembaum, Alan↗

Polyacrolein microspheres

Microspheres of acrolein homopolymers and copolymer with hydrophillic comonomers such as methacrylic acid and/or hydroxyethylmethacrylate are prepared by cobalt gamma irradiation of dilute aqueous solutions of the monomers in presence of suspending agents, especially alkyl sulfates such as sodium dodecyl sulfate. Amine or hydroxyl modification is achieved by forming adducts with diamines or alkanol amines. Carboxyl modification is effected by oxidation with peroxides. Pharmaceuticals or other aldehyde reactive materials can be coupled to the microspheres. The microspheres directly form antibody adducts without agglomeration.

Rembaum, Alan↗

Polyacrolein microspheres

Microspheres of acrolein homopolymers and copolymer with hydrophillic comonomers such as methacrylic acid and/or hydroxyethylmethacrylate are prepared by cobalt gamma irradiation of dilute aqueous solutions of the monomers in presence of suspending agents, especially alkyl sulfates such as sodium dodecyl sulfate. Amine or hydroxyl modification is achieved by forming adducts with diamines or alkanol amines. Carboxyl modification is effected by oxidation with peroxides. Pharmaceuticals or other aldehyde reactive materials can be coupled to the microspheres. The microspheres directly form antibody adducts without agglomeration.

Rembaum, Alan↗

Microsphere Insulation Panels

Microsphere insulation panels (MIPs) have been developed as lightweight, longlasting replacements for the foam and vacuum-jacketed systems heretofore used for thermally insulating cryogenic vessels and transfer ducts. The microsphere core material of a typical MIP consists of hollow glass bubbles, which have a combination of advantageous mechanical, chemical, and thermal-insulation properties heretofore available only separately in different materials. In particular, a core filling of glass microspheres has high crush strength and low density, is noncombustible, and performs well in soft vacuum.

Mohling, R.↗

Mitigation of Polystyrene Microsphere Surface Contamination for Wind Tunnel Applications

Polystyrene latex (PSL) microspheres have been utilized as seed material for flow visualization in wind tunnels. However, PSL microspheres have been observed to strongly adhere to wind tunnel and model surfaces. Surface contamination on the cleaning screens that remove vorticity and provide laminar flow in the test section, is particularly problematic. Agglomeration of particles on these screens cause constriction of the airflow through the screen resulting in inconsistent airflow properties in the test section. The adhesion mechanism of PSL microspheres to wind tunnel screens and 316 stainless steel flat plates, were evaluated in a contamination apparatus where small sections of screen material were exposed to PSL-seeded airflow. Using a design of experiments (DOE) methodology airflow seeding parameters were changed to evaluate how these modifications affected the degree of surface contamination. The solution composition, comprised of ethanol and water, was determined to be the most significant factor in particle adhesion. Utilizing image analysis software, data were collected from the contaminated surfaces and incorporated to generate predictive particle contamination models. A relationship was identified between the solvent evaporation rate, and the morphology and magnitude of PSL contaminants on the test surfaces. This analysis can be extended to other solvent mixtures to provide insight into simultaneously improving wind tunnel testing capabilities while diminishing facility contamination.

Wohl, Christopher J.↗

Apparatus and process to enhance the uniform formation of hollow glass microspheres

A process and apparatus is provided for enhancing the formation of a uniform population of hollow glass microspheres. A burner head is used which directs incoming glass particles away from the cooler perimeter of the flame cone of the gas burner and distributes the glass particles in a uniform manner throughout the more evenly heated portions of the flame zone. As a result, as the glass particles are softened and expand by a released nucleating gas so as to form a hollow glass microsphere, the resulting hollow glass microspheres have a more uniform size and property distribution as a result of experiencing a more homogenous heat treatment process.

47 OTHER INSTRUMENTATION↗

Microspheres and their methods of preparation

Carbon microspheres are doped with boron to enhance the electrical and physical properties of the microspheres. The boron-doped carbon microspheres are formed by a CVD process in which a catalyst, carbon source and boron source are evaporated, heated and deposited onto an inert substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Doxorubicin-Loaded QuadraSphere Microspheres: Plasma Pharmacokinetics and Intratumoral Drug Concentration in an Animal Model of Liver Cancer

The purpose of this study was to evaluate, in vitro and in vivo, doxorubicin-loaded poly (vinyl alcohol-sodium acrylate) copolymer microspheres [QuadraSphere microspheres (QSMs)] for transcatheter arterial delivery in an animal model of liver cancer. Doxorubicin loading efficiency and release profile were first tested in vitro. In vivo, 15 rabbits, implanted with a Vx-2 tumor in the liver, were divided into three groups of five rabbits each, based on the time of euthanasia. Twenty-five milligrams of QSMs was diluted in 10 ml of a 10 mg/ml doxorubicin solution and 10 ml of nonionic contrast medium for a total volume of 20 ml. One milliliter of a drug-loaded QSM solution containing 5 mg of doxorubicin was injected into the tumor feeding artery. Plasma doxorubicin and doxorubicinol concentrations, and intratumoral and peritumoral doxorubicin tissue concentrations, were measured. Tumor specimens were pathologically evaluated to record tumor necrosis. As a control, one animal was blandly embolized with plain QSMs in each group. In vitro testing of QSM doxorubicin loadability and release over time showed 82-94% doxorubicin loadability within 2 h and 6% release within the first 6 h after loading, followed by a slow release pattern. In vivo, the doxorubicin plasma concentration declined at 40 min. The peak doxorubicin intratumoral concentration was observed at 3 days and remained detectable till the study's end point (7 days). Mean percentage tumor cell death in the doxorubicin QSM group was 90% at 7 days and 60% in the bland QSM embolization group. In conclusion, QSMs can be efficiently loaded with doxorubicin. Initial experiments with doxorubicin-loaded QSMs show a safe pharmacokinetic profile and effective tumor killing in an animal model of liver cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Midterm Results of Uterine Artery Embolization Using Narrow-Size Calibrated Embozene Microspheres

Purpose: To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). Methods: Between May 2006 and September 2008, a total of 121 consecutive patients (mean {+-} SD age 42.1 {+-} 5.4 years, range 30.5-51.5 years) were enrolled onto this single-center study. The primary study endpoint was safety as assessed by the society of interventional radiology (SIR) classification. The secondary endpoint was efficacy, which was based on a 1-year magnetic resonance imaging study and relief of symptoms documented by the Medical Outcomes Study 36-Item Short-Form Health Survey questionnaire over a 2-year interval. Results: The mean {+-} SD diameter of the dominant fibroid was 6.4 {+-} 2.6 (range, 2.9-13.9) cm and the mean volume 137.2 {+-} 245.1 (range, 5.3-1184) ml. Most patients had multiple fibroids with 11% more than 10. A total of 240 of 242 interventions were completed as planned, a technical success rate of 99.2%. According to the SIR classification, one type A, eight type C, and one type D complication occurred. Total devascularization was noted in 96% (116 of 121) of dominant fibroids. Volume decrease was 4% at 2 weeks, 52% (P < 0.001) at 3 months, 78% (P < 0.001) at 6 months, and 91% at 12 months (P < 0.001). The latter difference was statistically significant (P = 0.007). A total of 92% had improved hypermenorrhea at 1 year and 94% at 2 years. Dysmenorrhea was improved in 96% at 1 year and in 95% at 2 years. The overall health status score was 60.4 {+-} 26.2 points at baseline and 96.9 {+-} 3.8 after 1 year (P = 0.0019).ConclusionUterine artery embolization with Embozene microspheres is a safe procedure. Its efficacy is demonstrated by high fibroid devascularization and volume reduction rates and significant improvements of clinical symptoms and quality-of-life scores during follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioembolization of Symptomatic, Unresectable Neuroendocrine Hepatic Metastases Using Yttrium-90 Microspheres

Purpose: To evaluate safety, efficacy, and symptom-control of radioembolization in patients with unresectable liver metastases from neuroendocrine tumors (NETLMs). Materials and Methods: Forty-two patients (mean age of 62 years) with treatment-refractory NETLMs underwent radioembolization using yttrium-90 ({sup 90}Y) resin microspheres. Posttreatment tumor response was assessed by cross-sectional imaging using the Response Evaluation Criteria in Solid Tumors (RECIST) and tumor-marker levels. Laboratory and clinical toxicities and clinical symptoms were monitored. Results: The median activity delivered was 1.63 GBq (range 0.63-2.36). Imaging follow-up using RECIST at 3-month follow-up demonstrated partial response, stable disease, and progressive disease in 22.5, 75.0, and 2.5% of patients, respectively. In 97.5% of patients, the liver lesions appeared hypovascular or partially necrotic. The mean follow-up was 16.2 months with 40 patients (95.2%) remaining alive. The median decrease in tumor-marker levels at 3 months was 54.8% (chromogranin A) and 37.3% (serotonin), respectively. There were no acute or delayed toxicities greater than grade 2 according to Common Terminology Criteria for Adverse Events [CTCAE (v3.0)]. No radiation-induced liver disease was noted. Improvement of clinical symptoms 3 months after treatment was observed in 36 of 38 symptomatic patients. Conclusion: Radioembolization with {sup 90}Y-microspheres is a safe and effective treatment option in patients with otherwise treatment-refractory NETLMs. Antitumoral effect is supported by good local tumor control, decreased tumor-marker levels, and improved clinical symptoms. Further investigation is warranted to define the role of radioembolization in the treatment paradigm for NETLMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity of Doxorubicin on Pig Liver After Chemoembolization with Doxorubicin-loaded Microspheres: A Pilot DNA-microarrays and Histology Study

The potential mechanisms accounting for the hepatotoxicity of doxorubicin-loaded microspheres in chemoembolization were examined by combining histology and DNA-microarray techniques.The left hepatic arteries of two pigs were embolized with 1 mL of doxorubicin-loaded (25 mg; (DoxMS)) or non-loaded (BlandMS) microspheres. The histopathological effects of the embolization were analyzed at 1 week. RNAs extracted from both the embolized and control liver areas were hybridized onto Agilent porcine microarrays. Genes showing significantly different expression (p < 0.01; fold-change > 2) between two groups were classified by biological process. At 1 week after embolization, DoxMS caused arterial and parenchymal necrosis in 51 and 38 % of embolized vessels, respectively. By contrast, BlandMS did not cause any tissue damage. Up-regulated genes following embolization with DoxMS (vs. BlandMS, n = 353) were mainly involved in cell death, apoptosis, and metabolism of doxorubicin. Down-regulated genes (n = 120) were mainly related to hepatic functions, including enzymes of lipid and carbohydrate metabolisms. Up-regulated genes included genes related to cell proliferation (growth factors and transcription factors), tissue remodeling (MMPs and several collagen types), inflammatory reaction (interleukins and chemokines), and angiogenesis (angiogenic factors and HIF1a pathway), all of which play an important role in liver healing and regeneration. DoxMS caused lesions to the liver, provoked cell death, and disturbed liver metabolism. An inflammatory repair process with cell proliferation, tissue remodeling, and angiogenesis was rapidly initiated during the first week after chemoembolization. This pilot study provides a comprehensive method to compare different types of DoxMS in healthy animals or tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗