Opto/Mechanical Design of the Micro-Arcsecond Metrology Testbed Interferometer
The Micro Arcsecond Metrology Testbed (MAM) is a laboratory-based, long baseline, white-light interferometer inside a vibration-isolated vacuum tank.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The Micro Arcsecond Metrology Testbed (MAM) is a laboratory-based, long baseline, white-light interferometer inside a vibration-isolated vacuum tank.
At the Advanced Light Source (ALS), we are developing broadly applicable, high-accuracy, in-situ, at-wavelength wavefront slope measurement techniques for Kirkpatrick-Baez (KB) mirror nano-focusing. In this paper, we report an initial cross-check of ex-situ and in-situ metrology of a bendable temperature stabilized KB mirror. This cross-check provides a validation of the in-situ shearing interferometry currently under development at the ALS.
At the Advanced Light Source (ALS), we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront slope measurement techniques for Kirkpatrick-Baez (KB) mirror nano-focusing. We describe here details of the metrology beamline endstation, the at-wavelength tests, and an original alignment method that have already allowed us to precisely set a bendable KB mirror to achieve a FWHM focused spot size of ~;;120 nm, at 1-nm soft x-ray wavelength.
Experiments using high brightness X-rays are on the forefront of science due to the vast variety of knowledge they can provide. New Synchrotron Radiation (SR) and Free Electron Laser (FEL) light sources provide unique tools for advanced studies using X-rays. Top-level scientists from around the world are attracted to these beamlines to perform unprecedented experiments. High brightness, low emittance light sources allow beamline scientists the possibility to dream up cutting-edge experimental stations. X-ray optics play a key role in bringing the beam from the source to the experimental stations. This paper explores the recent developments in X-ray optics. It touches on simulations, diagnostics, metrology and adaptive optics, giving an overview of the role X-ray optics have played in the recent past. It will also touch on future developments for one of the most active field in the X-ray science.
Adaptive x-ray mirrors are emerging as one of the primary solutions for meeting the performance needs of the next generation of x-ray light sources. Currently, these mirrors operate open loop with intermittent feedback from invasive sensors that measure the beam quality. This paper outlines a novel design for real-time in situ metrology of the shape of these mirrors using an array of interferometric sensors that does not interrupt the x-ray beam. We describe a proof-of-principle demonstration which shows sub-nm agreement over a range of mirror deflection magnitudes and shapes as compared to simultaneous measurements by using a large-aperture Fizeau interferometer.
Going beyond the standard quantum limit in noisy quantum metrology is an important and challenging task. Here we show how Dicke states can be used to surpass the standard quantum limit and achieve the Heisenberg limit in open quantum systems. The system we study has qubits symmetrically coupled to a resonator, and our objective is to estimate the coupling between the qubits and the resonator. The time-dependent quantum Fisher information with respect to the coupling is studied for this open quantum system where the same decay rates are assumed on all qubits. We show that when the system is initialized to a Dicke state with an optimal excitation number one can go beyond the standard quantum limit and achieve the Heisenberg limit even for finite values of the decays on the qubit and the resonator, particularly when the qubits and resonator are strongly coupled. We compare our results against the highly entangled GHZ state and a completely separable state and show that the GHZ state performs quite poorly, whereas under certain noise conditions the separable state is able to go beyond the standard quantum limit due to subsequent interactions with a resonator.
Quantum entanglement and coherence often allow for protocols that outperform classical ones in estimating a system’s parameter. When using infinite-dimensional probes (such as a bosonic mode), one could, in principle, obtain infinite precision in a finite time for both classical and quantum protocols, which makes it hard to quantify potential quantum advantage. However, such a situation is unphysical, as it would require infinite resources, so one needs to impose some additional constraint: typically the average energy employed by the probe is finite. Here we treat both energy and time as a resource, showing that, in the presence of noise, there is a nontrivial interplay between the average energy and the time devoted to the estimation. Our results are valid for the most general metrological schemes (e.g., adaptive schemes, which may involve entanglement with external ancillae or any kind of continuous measurement). We apply recently derived precision bounds for all parameters characterizing the paradigmatic case of a bosonic mode, subject to Lindbladian noise. We show how the time employed in the estimation should be partitioned in order to achieve the best possible precision. In most cases, the optimal performance may be obtained without the necessity of adaptivity or entanglement with ancilla. We compare results with classical strategies. Interestingly, for temperature estimation, applying a fast-prepare-and-measure protocol with Fock states provides better scaling with the number of photons than any classical strategy.
The project was divided into three subprojects. The first subproject is Fuel Cell Manufacturing Variability and Its Impact on Performance. The objective was to determine if flow field channel dimensional variability has an impact on fuel cell performance. The second subproject is Non-contact Sensor Evaluation for Bipolar Plate Manufacturing Process Control and Smart Assembly of Fuel Cell Stacks. The objective was to enable cost reduction in the manufacture of fuel cell plates by providing a rapid non-contact measurement system for in-line process control. The third subproject is Optical Scatterfield Metrology for Online Catalyst Coating Inspection of PEM Soft Goods. The objective was to evaluate the suitability of Optical Scatterfield Microscopy as a viable measurement tool for in situ process control of catalyst coatings.
The TREAT Reactor Metrology (RMet) program provides value through the post-irradiation gamma spectroscopy of flux and fission wires.
Metrology requirements for Apollo project, noting control and measuring equipment and calibration procedures
We describe the Metrology System for NASA's StarLight mission, a space-based separated-spacecraft stellar interferometer.
A facility to test the linearity and drift of heterodyne laser metrology gauges for measuring distances of 1 to 7 meters with 10 picometer repeatability is described.
This paper discusses the techniques for the reduction of cyclic errors in laser metrology gauges for the space interferometry mission.
Describes a metrology subsystem for NASA's Starlight mission, a space-based separated-spacecraft stellar interferometer.
In this paper, the metrology pointing sensor of the Starlight ground instrument prototype is characterized and a siderostat pointing control loop is closed between two optical benches with a 10 meter separation.
The Space Interferometry Mission (SIM) relies on interferometry and metrology capable of measuring the change in the optical path difference with picometer accuracy.
An assessment of the inflight performance of the Shuttle Radar Topography Mission (SRTM) Metrology System, also known as the Attitude and Orbit Determination avionics (AODA), is presented. The assessment is based on analysis of raw sensor data obtained during the mission.
This paper provides a description of the metrology camera, the process used to prepare it for flight on SRTM, the LED target development effort, test and alignment issues, and the observed in-flight performance.