Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MASS DISTRIBUTION AND ASSEMBLY OF THE MILKY WAY FROM THE PROPERTIES OF THE MAGELLANIC CLOUDS

We present a new measurement of the mass of the Milky Way (MW) based on observed properties of its largest satellite galaxies, the Magellanic Clouds (MCs), and an assumed prior of a {Lambda}CDM universe. The large, high-resolution Bolshoi cosmological simulation of this universe provides a means to statistically sample the dynamical properties of bright satellite galaxies in a large population of dark matter halos. The observed properties of the MCs, including their circular velocity, distance from the center of the MW, and velocity within the MW halo, are used to evaluate the likelihood that a given halo would have each or all of these properties; the posterior probability distribution function (PDF) for any property of the MW system can thus be constructed. This method provides a constraint on the MW virial mass, 1.2{sup +0.7}{sub -0.4} (stat.){sup +0.3}{sub -0.3} (sys.) Multiplication-Sign 10{sup 12} M{sub Sun} (68% confidence), which is consistent with recent determinations that involve very different assumptions. In addition, we calculate the posterior PDF for the density profile of the MW and its satellite accretion history. Although typical satellites of 10{sup 12} M{sub Sun} halos are accreted over a wide range of epochs over the last 10 Gyr, we find a {approx}72% probability that the MCs were accreted within the last Gyr, and a 50% probability that they were accreted together.

79 ASTRONOMY AND ASTROPHYSICS↗

DARK MATTER AS AN ACTIVE GRAVITATIONAL AGENT IN CLOUD COMPLEXES

We study the effect that the dark matter background (DMB) has on the gravitational energy content and, in general, on the star formation efficiency (SFE) of a molecular cloud (MC). We first analyze the effect that a dark matter halo, described by the Navarro-Frenk-White density profile, has on the energy budget of a spherical, homogeneous cloud located at different distances from the halo center. We found that MCs located in the innermost regions of a massive galaxy can feel a contraction force greater than their self-gravity due to the incorporation of the potential of the galaxy's dark matter halo. We also calculated analytically the gravitational perturbation that an MC produces over a uniform DMB (uniform at the scales of an MC) and how this perturbation will affect the evolution of the MC itself. The study shows that the star formation in an MC will be considerably enhanced if the cloud is located in a dense and low velocity dark matter environment. We confirm our results by measuring the SFE in numerical simulations of the formation and evolution of MCs within different DMBs. Our study indicates that there are situations where the dark matter's gravitational contribution to the evolution of the MCs should not be neglected.

79 ASTRONOMY AND ASTROPHYSICS↗

DUST DESTRUCTION RATES AND LIFETIMES IN THE MAGELLANIC CLOUDS

The dust budget in galaxies depends on the rate at which dust grains are created in different stellar sources and destroyed by interstellar shocks. Because of their extensive wavelength coverage, proximity, and nearly face-on geometry, the Magellanic Clouds (MCs) provide a unique opportunity to study these processes in great detail. In this paper, we use the complete sample of supernova remnants (SNRs) in the MCs to calculate the lifetimes and destruction efficiencies of silicate and carbon dust. We find dust lifetimes of 22 ± 13 Myr (30 ± 17 Myr) for silicate (carbon) grains in the LMC, and 54 ± 32 Myr (72 ± 43 Myr) for silicate (carbon) grains in the SMC. The corresponding dust destruction rates are 2.3 × 10{sup –2} M {sub ☉} yr{sup –1} (5.9 × 10{sup –3} M {sub ☉} yr{sup –1}) and 3.0 × 10{sup –3} M {sub ☉} yr{sup –1} (5.6 × 10{sup –4} M {sub ☉} yr{sup –1}) for silicate (carbon) grains in the LMC and SMC, respectively. The significantly shorter lifetimes in the MCs, as compared to the Milky Way, are explained as the combined effect of their lower total dust mass and preferentially higher dust-to-gas (D2G) mass ratios in the vicinity of the SNRs. We find that the maximum dust injection rates by asymptotic giant branch stars and core collapse supernovae are an order of magnitude lower than the dust destruction rates by the SNRs, suggesting that most of the dust may be reconstituted in dense molecular clouds. We also discuss the dependence of the dust destruction rate on the local D2G mass ratio, ambient gas density, and metallicity, as well as the application of our results to other galaxies and dust evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

NEW EVIDENCE FOR HIGH ACTIVITY OF THE SUPERMASSIVE BLACK HOLE IN OUR GALAXY

Prominent K-shell emission lines of neutral iron (hereafter Fe I-K lines) and hard-continuum X-rays from molecular clouds (MCs) in the Sagittarius B (Sgr B) region were found in two separate Suzaku observations in 2005 and 2009. The X-ray flux of the Fe I-K lines decreased in correlation with the hard-continuum flux by a factor of 0.4-0.5 in four years, which is almost equal to the light traveling across the MCs. The rapid and correlated time variability, the equivalent width of the Fe I-K lines, and the K edge absorption depth of Fe I are consistently explained by 'X-ray echoes' due to the fluorescent and Thomson scattering of an X-ray flare from an external source. The required flux of the X-ray flare depends on the distance to the MCs and its time duration. Even for a case with a minimum distance, the flux is larger than those of the brightest Galactic X-ray sources. Based on these facts, we conclude that the supermassive black hole Sgr A* exhibited a large flare a few hundred years ago with a luminosity of more than 4 x 10{sup 39} erg s{sup -1}. The 'X-ray echo' from Sgr B, located a few hundred light-years from Sgr A*, has now reached the Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

A multishock model for the density variance of anisotropic, highly magnetized, supersonic turbulence

ABSTRACT Shocks form the basis of our understanding for the density and velocity statistics of supersonic turbulent flows, such as those found in the cool interstellar medium (ISM). The variance of the density field, $\sigma ^2_{\rho /\rho _0}$, is of particular interest for molecular clouds (MCs), the birthplaces of stars in the Universe. The density variance may be used to infer underlying physical processes in an MC, and parametrizes the star formation (SF) rate of a cloud. However, models for $\sigma ^2_{\rho /\rho _0}$ all share a common feature – the variance is assumed to be isotropic. This assumption does not hold when a trans-/sub-Alfvénic mean magnetic field, ${B}_0$, is present in the cloud, which observations suggest is relevant for some MCs. We develop an anisotropic model for $\sigma _{\rho /\rho _0}^2$, using contributions from hydrodynamical and fast magnetosonic shocks that propagate orthogonal to each other. Our model predicts an upper bound for $\sigma _{\rho /\rho _0}^2$ in the high Mach number $(\mathcal {M})$ limit as small-scale density fluctuations become suppressed by the strong ${B}_0$. The model reduces to the isotropic $\sigma _{\rho /\rho _0}^2\!-\!\mathcal {M}$ relation in the hydrodynamical limit. To validate our model, we calculate $\sigma _{\rho /\rho _0}^2$ from 12 high-resolution, three-dimensional, supersonic, sub-Alfvénic magnetohydrodynamical (MHD) turbulence simulations and find good agreement with our theory. We discuss how the two MHD shocks may be the bimodally oriented overdensities observed in some MCs and the implications for SF theory in the presence of a sub-Alfvénic ${B}_0$. By creating an anisotropic, supersonic density fluctuation model, this study paves the way for SF theory in the highly anisotropic regime of interstellar turbulence.

Beattie, James R.↗

Examining a hadronic γ-ray scenario for the radiative shell and molecular clouds of the old GeV supernova remnant G298.6−0.0

Abstract Based on the 13.7 yr Fermi-LAT data, Yeung, Bamba, and Sano (2023, PASJ, 75, 384) claimed detection of two γ-ray sources (namely Src-NE and Src-NW) associated with the supernova remnant (SNR) G298.6−0.0, and interpreted it as an old GeV SNR interacting with molecular clouds (MCs). In this follow-up study, we refine the flux measurements below 2 GeV with Fermi-LAT event types of better angular reconstruction. Then, we report our γ-ray spectral fittings and cosmic-ray phenomenology in a hadronic scenario, considering both the shell and MC regions of SNR G298.6−0.0. We confirm that the γ-ray spectra of both Src-NE and Src-NW exhibit spectral breaks, at $1.50_{-0.50}^{+0.60}$ and $0.68_{-0.11}^{+0.32}\:$GeV, respectively. Src-NW has a harder broad-band photon index than Src-NE, suggesting an appreciable difference between the physical separations of their respective emission sites from SNR G298.6−0.0. The cosmic-ray spectrum responsible for Src-NE starts with a minimum energy $E_\mathrm{CR,min}=1.38_{-0.16}^{+0.47}\:$GeV, and has a proton index $\Gamma _\mathrm{CR}=2.57_{-0.21}^{+0.18}$ below the exponential cutoff energy $E_\mathrm{CR,max}=240_{-150}^{+240}\:$GeV. Accordingly, we argue that Src-NE is dominated by the SNR shell, while only a minor portion of lower-energy emission is contributed by the MCs interacting with the SNR. The cosmic-ray population for Src-NW starts at a higher energy such that the ECR, min ratio of Src-NW to Src-NE is ≳2. The high ECR, min, as well as the high cosmic-ray energy density required (∼26 eV cm−3), supports the interpretation that Src-NW is predominantly the γ-ray emission from the farther MCs being bombarded by protons that had earlier escaped from SNR G298.6−0.0. By comparing the high-energy features of G298.6−0.0 with those of analogical SNRs, especially SNR W 28 and SNR W 44, we further constrain the age of SNR G298.6−0.0 to be 10–30 kyr, under the assumption of a purely hadronic scenario.

Astronomy & Astrophysics↗

Sensitivity of organized convective storms to model grid spacing in current and future climates

Mesoscale convective systems (MCSs) are complexes of thunderstorms that become organized and cover hundreds of kilometres over several hours. MCSs are prolific rain producers in the tropics and mid-latitudes and are the major cause of warm-season flooding. Traditionally, climate models have difficulties in simulating MCSs partly due to the misrepresentation of complex process interactions that operate across a large range of scales. Significant improvements in simulating MCSs have been found in kilometre-scale models that explicitly simulate deep convection. However, these models operate in the grey zone of turbulent motion and have known deficiencies in simulating small-scale processes (e.g. entrainment, vertical mass transport). Here, we perform mid-latitude idealized ensemble MCS simulations under current and future climate conditions in three atmospheric regimes: hydrostatic (12 km horizontal grid spacing; Δx), non-hydrostatic (Δx = 4, 2 and 1 km) and large eddy scale (Δx = 500 m and 250 m). Our results show a dramatic improvement in simulating MCS precipitation, movement, cold pools, and cloud properties when transitioning from 12 km to 4 km Δx. Decreasing Δx beyond 4 km results in modest improvements except for up- and downdraft sizes, average vertical mass fluxes, and cloud top height and temperature, which continue to change. Most important for climate modelling is that Δx = 4 km simulations reliably capture most MCS climate change signals compared to those of the Δx = 250 m runs. Significantly different climate change signals are found in Δx = 12 km runs that overestimate extreme precipitation changes by up to 100%.

54 ENVIRONMENTAL SCIENCES↗

Two-pion-exchange and other higher-order contributions to the pp{yields}pp{pi}{sup 0} reaction

Much effort has been invested on effective-field-theoretical studies of the near-threshold NN{yields}NN{pi} reactions and, in order to deal with the somewhat large three-momentum transfers involved, the momentum counting scheme (MCS) was proposed as an alternative to the usual Weinberg counting scheme. Given the fact that a quantitative explanation of the existing high-precision NN{yields}NN{pi} data requires a careful examination of higher chiral order contributions to the transition operator, we make a detailed numerical investigation of the convergence property of MCS for a pilot case of the pp{yields}pp{pi}{sup 0} reaction. Our study indicates that MCS is superior to the Weinberg scheme in identifying dominant higher order contributions to the NN{yields}NN{pi} reactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics of Muon Computed Tomography of Used Fuel Casks Using Algebraic Reconstruction

Cosmic raymuons passing through matter lose energy from inelastic collisions with electrons and are deflected from nuclei due to multiple Coulomb scattering (MCS). The recent developments in position sensitive muon detectors that can measure incoming and outgoing trajectories of individual muons indicate that MCS could be an excellent candidate for spent nuclear fuel imaging. The main purpose of this paper is to evaluate tomographic scanning of spent nuclear fuel stored within vertical and horizontal dry storage casks. A quantitative analysis of the characteristics of images obtained with filtered back projection (FBP) and algebraic reconstruction techniques (ART) are presented herein, as such a comparison has not been carried out in the past. FBP is a fast tool to determine object boundaries. ART can include muon path models and prior knowledge that can improve resolution and reduce measurement time. The results demonstrate that missing fuel assemblies can be identified with more than 5 projections and that use of muon momentum significantly increases image resolution. It is expected that MCS can be used to successfully reconstruct the dry cask contents and allow identification of all described scenarios in hours. It is also expected that when total variation minimization and a non-local mean filter are applied, ART may yield much better image quality than FBP.

Liu, Zhengzhi↗

Probabilistic Sizing of Energy Storage Systems for Reliability and Frequency Security in Wind-Rich Power Grids

The penetration of wind energy has increased significantly in the power grid in recent times. Although wind is abundant, environment-friendly, and cheap, it is variable in nature and does not contribute to system inertia as much as conventional synchronous generators. Coupled with the low inertia contribution, the generation intermittency of wind power leads to reliability and stability issues in the power system. Energy storage systems (ESSs) are among the most prominent alternatives to alleviate these concerns associated with high wind penetration. This paper proposes a planning strategy to size ESS for the reliability and frequency security of wind-rich power grids. A probabilistic methodology for ESS sizing is developed utilizing a composite reliability-based framework with sequential Monte Carlo simulation (MCS). The MCS generates composite reliability indices for the power system, which are employed to obtain the capacity for a reliability energy storage system (RESS). Simultaneously, the MCS-derived probability of synchronization of conventional generators is integrated into an analytical approach for sizing a frequency support energy storage system (FESS). The effect of wind farm dispersion across geographical regions is incorporated in the framework to study possible reductions in the ESS size while maintaining the system reliability and frequency security. Furthermore, the efficacy of the proposed strategy is demonstrated on the RTS-GMLC test system.

25 ENERGY STORAGE↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-443: Developmental Technique for Proton Pencil Beam Measurements: Depth Dose

Purpose: Measurements of depth dose distribution (DDD) of pencil beam in proton therapy can be challenging and time consuming. We have developed a technique that uses two Bragg peak chambers to expedite these measurements with a high accuracy. Methods and Material: We used a PTW water tank and two PTW 10.5 cm3 Bragg peak chambers; one as a field chamber and the other as a reference chamber to measure DDDs for 100–250 MeV proton pencil beams. The reference chamber was positioned outside of the water tank upstream with respect to field chamber. We used Geant4 Monte Carlo Simulation (MCS) to model the ProTom proton beam to generate DDDs. The MCS generated DDDs were used to account for halo effects of proton pencil beam that are not measureable with Bragg peak chambers. We also used PTW PEAKFINDER to measure DDDs for comparison purpose. Results: We compared measured and MCS DDDs with Continuous Slowing Down Approximation (CSDA) ranges to verify the range of proton beams that were supplied by the manufacturer. The agreements between all DDD with respect to CSDA were within ±0.5 mm. The WET for Bragg peak chamber for energies between 100–250 MeV was 12.7 ± 0.5 mm. The correction for halo effect was negligible below 150 MeV and was in order of ∼5-10% for 150–250 MeV. Conclusion: Use of Bragg Peak chamber as a reference chamber can facilitate DDD measurements in proton pencil beam with a high accuracy. Some corrections will be required to account for halo effect in case of high energy proton beams due to physical size of chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-BRF-01: FEATURED PRESENTATION - Investigating Particle Track Structures Using Fluorescent Nuclear Track Detectors and Monte Carlo Simulations

Purpose: To report on the efforts funded by the AAPM seed funding grant to develop the basis for fluorescent nuclear track detector (FNTD) based radiobiological experiments in combination with dedicated Monte Carlo simulations (MCS) on the nanometer scale. Methods: Two confocal microscopes were utilized in this study. Two FNTD samples were used to find the optimal microscope settings, one FNTD irradiated with 11.1 MeV/u Gold ions and one irradiated with 428.77 MeV/u Carbon ions. The first sample provided a brightly luminescent central track while the latter is used to test the capabilities to observe secondary electrons. MCS were performed using TOPAS beta9 version, layered on top of Geant4.9.6p02. Two sets of simulations were performed, one with the Geant4-DNA physics list and approximating the FNTDs by water, a second set using the Penelope physics list in a water-approximated FNTD and a aluminum-oxide FNTD. Results: Within the first half of the funding period, we have successfully established readout capabilities of FNTDs at our institute. Due to technical limitations, our microscope setup is significantly different from the approach implemented at the DKFZ, Germany. However, we can clearly reconstruct Carbon tracks in 3D with electron track resolution of 200 nm. A second microscope with superior readout capabilities will be tested in the second half of the funding period, we expect an improvement in signal to background ratio with the same the resolution.We have successfully simulated tracks in FNTDs. The more accurate Geant4-DNA track simulations can be used to reconstruct the track energy from the size and brightness of the observed tracks. Conclusion: We have achieved the goals set in the seed funding proposal: the setup of FNTD readout and simulation capabilities. We will work on improving the readout resolution to validate our MCS track structures down to the nanometer scales.

60 APPLIED LIFE SCIENCES↗

Online adaptation and verification of VMAT

Purpose: This work presents a method for fast volumetric modulated arc therapy (VMAT) adaptation in response to interfraction anatomical variations. Additionally, plan parameters extracted from the adapted plans are used to verify the quality of these plans. The methods were tested as a prostate class solution and compared to replanning and to their current clinical practice. Methods: The proposed VMAT adaptation is an extension of their previous intensity modulated radiotherapy (IMRT) adaptation. It follows a direct (forward) planning approach: the multileaf collimator (MLC) apertures are corrected in the beam’s eye view (BEV) and the monitor units (MUs) are corrected using point dose calculations. All MLC and MU corrections are driven by the positions of four fiducial points only, without need for a full contour set. Quality assurance (QA) of the adapted plans is performed using plan parameters that can be calculated online and that have a relation to the delivered dose or the plan quality. Five potential parameters are studied for this purpose: the number of MU, the equivalent field size (EqFS), the modulation complexity score (MCS), and the components of the MCS: the aperture area variability (AAV) and the leaf sequence variability (LSV). The full adaptation and its separate steps were evaluated in simulation experiments involving a prostate phantom subjected to various interfraction transformations. The efficacy of the current VMAT adaptation was scored by target mean dose (CTV{sub mean}), conformity (CI{sub 95%}), tumor control probability (TCP), and normal tissue complication probability (NTCP). The impact of the adaptation on the plan parameters (QA) was assessed by comparison with prediction intervals (PI) derived from a statistical model of the typical variation of these parameters in a population of VMAT prostate plans (n = 63). These prediction intervals are the adaptation equivalent of the tolerance tables for couch shifts in the current clinical practice. Results: The proposed adaptation of a two-arc VMAT plan resulted in the intended CTV{sub mean} (Δ ≤ 3%) and TCP (ΔTCP ≤ 0.001). Moreover, the method assures the intended CI{sub 95%} (Δ ≤ 11%) resulting in lowered rectal NTCP for all cases. Compared to replanning, their adaptation is faster (13 s vs 10 min) and more intuitive. Compared to the current clinical practice, it has a better protection of the healthy tissue. Compared to IMRT, VMAT is more robust to anatomical variations, but it is also less sensitive to the different correction steps. The observed variations of the plan parameters in their database included a linear dependence on the date of treatment planning and on the target radius. The MCS is not retained as QA metric due to a contrasting behavior of its components (LSV and AAV). If three out of four plan parameters (MU, EqFS, AAV, and LSV) need to lie inside a 50% prediction interval (3/4—50%PI), all adapted plans will be accepted. In contrast, all replanned plans do not meet this loose criterion, mainly because they have no connection to the initially optimized and verified plan. Conclusions: A direct (forward) VMAT adaptation performs equally well as (inverse) replanning but is faster and can be extended to real-time adaptation. The prediction intervals for the machine parameters are equivalent to the tolerance tables for couch shifts in the current clinical practice. A 3/4—50%PI QA criterion accepts all the adapted plans but rejects all the replanned plans.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-12: Using Machine Log-Files for Treatment Planning and Delivery QA

Purpose: To determine the segment reduction and dose resolution necessary for machine log-files to effectively replace current phantom-based patient-specific quality assurance, while minimizing computational cost. Methods: Elekta’s Log File Convertor R3.2 records linac delivery parameters (dose rate, gantry angle, leaf position) every 40ms. Five VMAT plans [4 H&N, 1 Pulsed Brain] comprised of 2 arcs each were delivered on the ArcCHECK phantom. Log-files were reconstructed in Pinnacle on the phantom geometry using 1/2/3/4° control point spacing and 2/3/4mm dose grid resolution. Reconstruction effectiveness was quantified by comparing 2%/2mm gamma passing rates of the original and log-file plans. Modulation complexity scores (MCS) were calculated for each beam to correlate reconstruction accuracy and beam modulation. Percent error in absolute dose for each plan-pair combination (log-file vs. ArcCHECK, original vs. ArcCHECK, log-file vs. original) was calculated for each arc and every diode greater than 10% of the maximum measured dose (per beam). Comparing standard deviations of the three plan-pair distributions, relative noise of the ArcCHECK and log-file systems was elucidated. Results: The original plans exhibit a mean passing rate of 95.1±1.3%. The eight more modulated H&N arcs [MCS=0.088±0.014] and two less modulated brain arcs [MCS=0.291±0.004] yielded log-file pass rates most similar to the original plan when using 1°/2mm [0.05%±1.3% lower] and 2°/3mm [0.35±0.64% higher] log-file reconstructions respectively. Log-file and original plans displayed percent diode dose errors 4.29±6.27% and 3.61±6.57% higher than measurement. Excluding the phantom eliminates diode miscalibration and setup errors; log-file dose errors were 0.72±3.06% higher than the original plans – significantly less noisy. Conclusion: For log-file reconstructed VMAT arcs, 1° control point spacing and 2mm dose resolution is recommended, however, less modulated arcs may allow less stringent reconstructions. Following the aforementioned reconstruction recommendations, the log-file technique is capable of detecting delivery errors with equivalent accuracy and less noise than ArcCHECK QA. I am funded by an Elekta Research Grant.

60 APPLIED LIFE SCIENCES↗