Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNP6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Predicting Future Solar Modulation and Implementation in MCNP6

The application of detecting low level radiation in the field requires quantification of the natural radiation background specific to that location. This background is made up two primary components: naturally decaying radionuclides in the soil and atmosphere known as terrestrial background, and the particle cascades caused by high energy cosmic radiation interacting within the earth's atmosphere known as cosmic background. The terrestrial component dominates the background spectrum below approximately 2 MeV, however, the cosmic component comprises the entirety of the high-energy spectrum. Furthermore, the terrestrial component is relatively constant for a given location while the cosmic component is heavily dependent on solar activity, an effect known as solar modulation. Annual values of the solar modulation parameter, φ, have been determined since 1936, and their fluctuations are seen to be roughly sinusoidal over time. If one wished to predict or simulate the outcome of an experiment in the future, a prediction for the solar modulation would be necessary to accurately determine the cosmic background contribution. The previous version 6.1.1 of MCNP contained solar modulation data for 46 years between 1960 and 2005. This data was updated with newer solar modulation data, from I. G. Usoskin et al., which reports solar modulation data for an additional 33 years between 1936 and 2014. In order to use past solar modulation data to predict cosmic background radiation fluctuations for dates beyond 2014 an algorithm was developed to forecast future solar modulation data based on the sinusoidal behavior exhibited in recorded data. This algorithm was implemented into MCNP 6.1.2 to be used for cosmic background simulations and tested against benchmark data to assess its accuracy. (authors)

54 ENVIRONMENTAL SCIENCES↗

Sensitivity Study of Void Coefficients in the SHEBA-II Critical Assembly using MCNP6

SHEBA-II was an aqueous critical assembly experiment that was operated at the Los Alamos Critical Experiments Facility. It is a bare assembly that is fueled with an aqueous solution of ∼5% enriched nonstoichiometric uranyl fluoride. The composition of uranyl fluoride changes over time due to chemical and nuclear reactions taking place within the assembly. This study investigates how changes in the solution temperature, void volume, and void location effect criticality, and to provide information about potential hazards in off-normal situations. This study had extended previous work on the SHEBA-II CAV to include temperature dependence, void volume dependence, and the thermochemical properties of the solution (density). The overall results indicate that a critical boiling solution cannot be reached. The solution height needed within the tank to become critical would overfill the tank. For future work, these results will be used to calculate the temperature effects on void reactivity coefficients. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of NORM in an Urban Environment using HPGe Measurements and MCNP6 Simulations

This work is part of a larger project aimed at producing an operationally relevant, validated simulation environment that can be used as a 'virtual testbed' for counterterrorism and counterproliferation efforts. Examples of such efforts include searches for illicit radiation sources before and during large special events, such as the presidential nominating conventions, inaugurations, and large sporting events. Once validated by laboratory and field measurements, this testbed can be used to test and validate algorithms and detector systems designed for various search missions in an urban environment. The detection of radioactive sources in a city is greatly complicated by natural background radiation, which emanates from various materials common to an urban environment, such as roadways, sidewalks, and building exteriors. The methods and results offered here represent the conclusion of an effort to characterize the concentration of naturally occurring radioactive material (NORM) in various elements in a controlled, but representative, urban environment. Some of the methods discussed in previous work will be briefly reiterated here, but more detail can be found in the preceding work. The location chosen for this effort was a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site was chosen because it replicates a small town where traffic and pedestrian access could be easily controlled, as to not interfere with the background measurements. This endeavor involved over 70 measurements using a high-purity germanium (HPGe) detector designed to ascertain the NORM concentrations in the soil, asphalt roads, gravel lots, concrete intersections, sidewalks, foundations, and walls found throughout the site. The NORM concentrations determined from this work will be incorporated into a large-scale simulation that can be used to investigate various search techniques and algorithms, detector types and setups, and to produce representative synthetic data for future work.

07 ISOTOPE AND RADIATION SOURCES↗

MCNP6 and SERPENT2 Performances with Unstructured Mesh Geometry

Traditionally, Monte Carlo codes model a nuclear reactor by combinatorial geometry. In this model, volume primitives (e,g, spheres, cylinders, parallelepipeds...) are combined together by Boolean operations (e.g. union, intersection, and complement) and replicated by lattice definitions to build the core geometry. Recently, high performances computing platforms allowed using unstructured mesh geometry in Monte Carlo codes. When this option is chosen, any type of core geometry can be modeled since the restriction of using volume primitives is removed. In an unstructured mesh geometry, Boolean operations and lattice definitions are not used since each volume is defined by triangular surfaces (facets). This study focuses on two Monte Carlo codes: MCNP (version 6.1.1 beta) developed at Los Alamos National Laboratory since 1957 and written in FORTRAN90, C, and C++ (267,000 total source code lines), and SERPENT (version 2.1.27) developed at VTT Technical Research Centre since 2004 and written in C (195,000 total source code lines). These two codes follow different approaches for the unstructured mesh geometry modeling: MCNP uses ABAQUS format, whereas SERPENT uses the STL format. In the STL (STereoLithographic) geometry model only the surfaces of the volume are meshed; the interior part of the volumes is not meshed. In the STL geometry model, the whole geometry is defined by the sequence of SOLID and ENDSOLID sections. Each volume of the geometry must have a SOLID and ENDSOLID section. The STL file contains no information specifying the materials of the volumes. MCNP and SERPENT can model any kind of complicated geometry using unstructured meshes. MCNP and SERPENT use the ABAQUS and STL file formats, respectively. The STL file format does not have tetrahedrons and has only triangular facets on the volumes boundary. This allows SERPENT simulations to run 10 times faster than MCNP. However, if Monte Carlo results have to be coupled to thermal-hydraulics codes, the interior of the geometry volumes must be meshed, which may reduce SERPENT performances.

97 MATHEMATICS AND COMPUTING↗

Impact of new prompt fission neutron spectrum evaluations and the associated cross-correlations on critical assemblies using MCNP6 - 14385

Two recent re-evaluations of the neutron-induced prompt fission neutron spectrum (PFNS) of uranium and plutonium actinides have included some cross-correlated uncertainties that have not been released in a new nuclear data library. The first re-evaluation included cross-isotope correlations of the PFNS within each of the uranium and plutonium suites of actinides below the second-chance fission threshold. The second, more recent re-evaluation includes incident energy-dependent correlations of the {sup 239}Pu(n,f) PFNS. Both of these new evaluations and their cross-correlations, given the importance of these actinide quantities and because the impact of the incident energy-dependent correlations has never been studied previously, could have an impact on a variety of criticality safety applications. For example, the ke uncertainty due to the uranium PFNS uncertainties in the Big Ten critical assembly is underpredicted by ∼10% when the cross-isotope correlations in the uranium PFNS are ignored. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo Simulations of the Water Draining Experiment of Giacint Critical Assembly

The MCNP6 computer program has been successfully extended to simulate reactor dynamics problems with moving parts of the geometries. Different from the dynamic method developed in other Monte Carlo codes, a movement scheme has been developed to account for the geometrical parts motion during the particle random walk. The MCNP6 computer program has been used to simulate two transient experiments of the Giacint critical assembly. The MCNP6 calculated total neutron flux was compared with that from the Serpent simulation. An excellent agreement was obtained between the results of the two Monte Caro computer programs. The MCNP6 calculated total neutron flux was also compared with the two measured transients. The MCNP6 results predicted a faster transient than the experimental data. The MCNP6 transient simulation was improved with an adjusted geometrical model which shifts the fuel rods slightly to match the measured reactivity worth due to the drained water. (c) 2021 Elsevier Ltd. All rights reserved.

MCNP, Moving Geometries, Monte Carlo Reactor Trans↗

SU-E-T-521: Investigation of the Uncertainties Involved in Secondary Neutron/gamma Production in Geant4/MCNP6 Monte Carlo Codes for Proton Therapy Application

Purpose: A major concern in proton therapy is the production of secondary neutrons causing secondary cancers, especially in young adults and children. Most utilized Monte Carlo codes in proton therapy are Geant4 and MCNP. However, the default versions of Geant4 and MCNP6 do not have suitable cross sections or physical models to properly handle secondary particle production in proton energy ranges used for therapy. In this study, default versions of Geant4 and MCNP6 were modified to better handle production of secondaries by adding the TENDL-2012 cross-section library. Methods: In-water proton depth-dose was measured at the “The Svedberg Laboratory” in Uppsala (Sweden). The proton beam was mono-energetic with mean energy of 178.25±0.2 MeV. The measurement set-up was simulated by Geant4 version 10.00 (default and modified version) and MCNP6. Proton depth-dose, primary and secondary particle fluence and neutron equivalent dose were calculated. In case of Geant4, the secondary particle fluence was filtered by all the physics processes to identify the main process responsible for the difference between the default and modified version. Results: The proton depth-dose curves and primary proton fluence show a good agreement between both Geant4 versions and MCNP6. With respect to the modified version, default Geant4 underestimates the production of secondary neutrons while overestimates that of gammas. The “ProtonInElastic” process was identified as the main responsible process for the difference between the two versions. MCNP6 shows higher neutron production and lower gamma production than both Geant4 versions. Conclusion: Despite the good agreement on the proton depth dose curve and primary proton fluence, there is a significant discrepancy on secondary neutron production between MCNP6 and both versions of Geant4. Further studies are thus in order to find the possible cause of this discrepancy or more accurate cross-sections/models to handle the nuclear interactions of protons with energy ranges used for therapy. NSERC-CRSNG’ CREATE Medical Physics Research Training Network compute calcul CANADA; McGill University health center research institute the fast foundation; LM acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering; Research Council Grant number 432290.

60 APPLIED LIFE SCIENCES↗

V&V of MCNP 6.1.1 Beta Against Intermediate and High-Energy Experimental Data

This report presents a set of validation and verification (V&V) MCNP 6.1.1 beta results calculated in parallel, with MPI, obtained using its event generators at intermediate and high-energies compared against various experimental data. It also contains several examples of results using the models at energies below 150 MeV, down to 10 MeV, where data libraries are normally used. This report can be considered as the forth part of a set of MCNP6 Testing Primers, after its first, LA-UR-11-05129, and second, LA-UR-11-05627, and third, LA-UR-26944, publications, but is devoted to V&V with the latest, 1.1 beta version of MCNP6. The MCNP6 test-problems discussed here are presented in the /VALIDATION_CEM/and/VALIDATION_LAQGSM/subdirectories in the MCNP6/Testing/directory. README files that contain short descriptions of every input file, the experiment, the quantity of interest that the experiment measures and its description in the MCNP6 output files, and the publication reference of that experiment are presented for every test problem. Templates for plotting the corresponding results with xmgrace as well as pdf files with figures representing the final results of our V&V efforts are presented. Several technical “bugs” in MCNP 6.1.1 beta were discovered during our current V&V of MCNP6 while running it in parallel with MPI using its event generators. These “bugs” are to be fixed in the following version of MCNP6. Our results show that MCNP 6.1.1 beta using its CEM03.03, LAQGSM03.03, Bertini, and INCL+ABLA, event generators describes, as a rule, reasonably well different intermediate- and high-energy measured data. This primer isn’t meant to be read from cover to cover. Readers may skip some sections and go directly to any test problem in which they are interested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Chlorine Capture and a Proposed Density Law on the Reactivity of Plutonium Solution Systems

During fissionable material processing, all normal and credible abnormal conditions must remain safely subcritical. Nuclear Criticality Safety (NCS) uses a number of methods to determine subcriticality, one of which is the use of neutron transport codes such as MCNP6. In order to create models for use with MCNP6, both the geometry and materials in fissionable material processes must be known, or assumptions must be made and quantified for the impact to bias. One of the systems with a significant amount of bias due to material modeling assumptions is in the area of aqueous plutonium processing. These solutions are typically plutonium nitrate solutions or plutonium chloride solutions, which are modeled as fictitious plutonium metal-water mixtures because little is known about the actual density of the solution and there is no current predictive capability approved for use at Los Alamos National Laboratory (LANL) for modeling them. This research is currently underway to fill the gap and develop an algorithm for use with MCNP6 to model the density of plutonium chloride solutions. The method is to be validated with experimental data for density, and also validated with critical experiments using MCNP6. Note that the Chlorine Worth Study (CWS) was performed in December 2021 to help bridge the gap in chlorine data for critical experiments, and is currently awaiting International Criticality Safety Benchmark Evaluation Project (ICSBEP) review. This study was performed by LANL at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS). Additional information regarding this experiment may currently be found in LA-UR- 22-29180. Additionally, the Chemistry-Actinide Analytical Chemistry (C-AAC) at LANL has performed a number of solution density measurements for PuCl 3 -HC 1 -H 2 O, allowing for such data be used to create a semi-empirical density via the Pitzer method. The published dataset for the measurements is documented in LA-UR-22-25454. This method has already been tested successfully for aqueous plutonium nitrate solutions in SCALE. Current solution density measurements exist of plutonium concentrations of 0-~142g/L, all at 2M HC1, at temperatures 20-40°C. Additional data was taken for HC1-corrected density values, which essentially mimics the data for a pure PuCl x -water solution. The calculations in this report aim to support the current research by demonstrating the difference in system reactivity for the current modeling method when compared to the new proposed modeling with a density law implementation, which is being written as a Python tool to be used with MCNP6.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Verification of Plutonium Content in PuBe Sources Using MCNP® 6.2.0 Beta with TENDL 2012 Libraries

Although the production of PuBe neutron sources has discontinued, hundreds of sources with unknown or inaccurately declared plutonium content are in existence around the world. Institutions have undertaken the task of assaying these sources, measuring, and calculating the isotopic composition, plutonium content, and neutron yield. The nominal plutonium content, based off the neutron yield per gram of pure 239 Pu, has shown to be highly inaccurate. New methods of measuring the plutonium content allow a more accurate estimate of the true Pu content, but these measurements need verification. Using the TENDL 2012 nuclear data libraries, MCNP6 has the capability to simulate the (α, n) interactions in a PuBe source. Theoretically, if the source is modeled according to the plutonium content, isotopic composition, and other source characteristics, the calculated neutron yield in MCNP can be compared to the experimental yield, offering an indication of the accuracy of the declared plutonium content. In this study, three sets of PuBe sources from various backgrounds were modeled in MCNP6 1.2 Beta, according to the source specifications dictated by the individuals who assayed the source. Verification of the source parameters with MCNP6 also serves as a means to test the alpha transport capabilities of MCNP6 1.2 Beta with TENDL 2012 alpha transport libraries. Finally, good agreement in the comparison would indicate the accuracy of the source parameters in addition to demonstrating MCNP's capabilities in simulating (α, n) interactions.

(α,n)↗

Status of Cross-section Data Libraries for MCNP

The Data Team, part of the XCP-5 group at LANL, uses the NJOY code and other codes to prepare the cross-section data files used by the Monte Carlo codes MCNP5, MCNPX, and MCNP6. They perform extensive quality assurance checking of those data files. The cross-section data files are included with the releases of MCNP that are distributed by RSICC. MCNP5 is developed and supported by the Monte Carlo Codes group (XCP-3) at LANL. MCNPX is developed and supported by the NEN-5 group at LANL. MCNP6 is a merger of MCNP5 and MCNPX, with numerous additional features, and is jointly developed and supported by the XCP-3 and NEN-5 groups. MCNP5 and MCNPX are "frozen" codes, and all new development is being carried out only in the MCNP6 code. In the past, when new types of data or improved representations were developed, the Data Team would incorporate the changes into the cross-section data files, and the Monte Carlo groups would make corresponding changes to the MCNP codes to use the new data. At present, however, only MCNP6 is updated to handle new data representations; MCNP5/X are not.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation

These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such as MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of the Temporal Response of Coupled Asymmetrical Zero-Power Subcritical Bare Metal Reactor Systems

The behavior of symmetrical coupled-core systems has been extensively studied, yet there is a dearth of research on asymmetrical systems due to the increased complexity of the analysis of such systems. In this research, the multipoint kinetics method is applied to asymmetrical zeropower, subcritical, bare metal reactor systems. Existing research on asymmetrical reactor systems assumes symmetry in the neutronic coupling; however, it will be shown that this cannot always be assumed. Deep subcriticality adds another layer of complexity and requires modification of the multipoint kinetics equations to account for the effect of the external neutron source. A modified set of multipoint kinetics equations is derived with this in mind. Subsequently, the Rossi-alpha equations are derived for a two-region asymmetrical reactor system. The predictive capabilities of the radiation transport code MCNP6 for neutron noise experiments are shown in a comparison to the results of a series of Rossi-alpha measurements performed by J. Mihalczo utilizing a coupled set of symmetrical bare highly-enriched uranium (HEU) cylinders. The ptrac option within MCNP6 can generate time-tagged counts in a cell (list-mode data). The list-mode data can then be processed similarly to measured data to obtain values for system parameters such as the dual prompt neutron decay constants observable in a coupled system. The results from the ptrac simulations agree well with the historical measured values. A series of case studies are conducted to study the effects of geometrical asymmetry in the coupling between two bare metal HEU cylinders. While the coupling behavior of symmetrical systems has been reported on extensively, that of asymmetrical systems remains sparse. In particular, it appears that there has been no previous research in obtaining the coupling time constants for asymmetrically-coupled systems. The difficulty in observing such systems is due in part to the inability to determine the individual coupling coefficients from measurement: unlike the symmetrical cases, only the product of the values can be obtained. A method is proposed utilizing MCNP6 tally ratios to separate the coupling coefficients for such systems. This work provides insight into the behavior of asymmetrically-coupled systems as the separation distance between the two cores is changed and also as the asymmetry is increased. As the asymmetry increases, both the slower and the faster observable prompt neutron decay constants increase in magnitude. The coupling time constants are determined from the measured decay constants. As the separation distance increases, both coupling coefficients decrease as expected. Based on these findings, an effective computational method utilizing MCNP6 and the Rossialpha technique can be applied to the prediction of asymmetrical coupled system measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LANL-SNL Collaboration on NCS Validation.

During 2016, nuclear criticality safety (NCS) practitioners from SNL and code developers from LANL collaborated in several areas of interest to the DOE/NNSA Nuclear Criticality Safety Program (NCSP). This collaboration involved. Testing of the preliminary release of the MCNP6- Whisper methodology, with feedback to the developers, Sharing of the benchmark catalogs (the collection of MCNP input files and benchmark results), with 1101 cases from LANL and 866 cases from SNL, Comparison and analysis of 357 benchmarks common to both catalogs, Investigation of the impact of the different benchmark catalogs on sensitivity-uncertainty based NCS validation results from MCNP6-Whisper, Investigation of the impact of randomized selections from the benchmark catalog on sensitivity-uncertainty based validation results from MCNP6-Whisper. Investigation of the use of MCNP6-Whisper in selecting benchmarks for use in NCS validation for unique, nonstandard, legacy fuel applications. This paper summarizes the collaboration work and initial results. It must be noted that the results described herein are preliminary and need further research and detailed analysis. However, the initial results are very interesting, and it is important to share them with the NCSP community.

97 MATHEMATICS AND COMPUTING↗

MCNP 6.2.0 Delayed-Particle Production Improvements

Development began on a delayed-particle physics package for the Monte Carlo Radiation transport code MCNPX in 2004 incorporating the CINDER90 depletion code and delayed particle libraries. When MCNP5 was merged with MCNPX to form MCNP6 in 2010, this delayed-particle capability was passed on and has been continuously improved in subsequent versions of MCNP6. Today, the delayed-particle feature in MCNP6 allows for the production of delayed neutrons, gammas, betas, and alpha particles. Future development includes the addition of delayed-positron production in the next release of MCNP6. Delayed particles can be sampled with MCNP using the ACT card in conjunction with the FISSION and NONFISS keywords. The user can specify one or more of the four available delayed-particle types mentioned above on one or both of the FISSION and NONFISS keywords. If a delayed-particle type is selected on the FISSION keyword, then delayed production of that particle from fission products and their progeny will be produced. Likewise, if a delayed-particle type is selected on the NONFISS keyword then delayed production of that particle from non-fission interactions and spontaneous decay will be produced. In some cases, the sheer number of delayed particles that can be produced from nuclear reactions and spontaneous decay (i.e. hundreds of delayed gamma lines when spontaneous fission is possible) can make it difficult to achieve converged solutions in an efficient and timely manner. Truncation methods are the simplest form of variance reduction and can be used to decrease convergence times by limiting calculations to the phase space of interest. This paper introduces several such truncation methods that allow the user to restrict the number of possible delayed particles available for sampling to only those of interest in the problem. It is important to stress that the use of any truncation method should be verified by first assessing the impact of the truncated particles (i.e. by disabling the truncation) for one or more baseline cases. In addition to these new methods, a new delayed-gamma sampling algorithm implemented in MCNP 6.2.0 is introduced. Comparisons to ENDF data and analytical benchmarking with the new algorithm show a substantial improvement in accuracy over previous versions. New improvements to the delayed-particle capability have been added to MCNP 6.2.0. These improvements include an updated treatment of the THRESH keyword which omits delayed-particle lines below a set amplitude, and addition of the PECUT and HLCUT keywords which allow the user to truncate delayed-particles lines based on energy and half-life, respectively. The delayed-gamma sampling algorithm has also been improved to allow exact energy sampling. Comparisons of MCNP calculations directly to ENDF data and analytical benchmarks have verified the significant improvement in the new delayed gamma sampling algorithm. (authors)

97 MATHEMATICS AND COMPUTING↗