Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analysis of Magnetic Field Emissions and Shield Requirements for Interoperating High-Power EV Wireless Charging System

In this study, the magnetic field emission (MFE) is investigated for matching (identical primary and secondary couplers) and interoperating (different couplers) 11 kW wireless charging systems (WCS). The interoperating charging pads generate higher MFE than the matching charging-pads; hence, using interoperable couplers requires a more effective shielding. In this work, different shield topologies are investigated to suppress the MFE for interoperable conditions. Four 11 kW WCSs with the unipolar (uni) and bipolar (bi) transmitter (Tx) and receiver (Rx) pads has been investigated: 1) uniTx with uniRx, 2) uniTx with biRx, 3) biTx with uniRx, and 4) biTx with bi-Rx. The studied systems are designed for 11 kW WPT3 level with Z2 airgap class (140-150 mm) resembling the standard SAE-J2954. The WCSs are simulated in finite element analysis (FEA) and validated experimentally using a 11 kW biTx-biRx system. The experimental results match with the simulation results with <5% error. The FEA results show that a biTx needs a magnetic shield, and a uniTx needs an aluminum shield to meet the MFE under all interoperability and alignment conditions.

Mohammad, Mostak↗

Calculation of nuclear spin-spin coupling constants using frozen density embedding

We present a method for a subsystem-based calculation of indirect nuclear spin-spin coupling tensors within the framework of current-spin-density-functional theory. Our approach is based on the frozen-density embedding scheme within density-functional theory and extends a previously reported subsystem-based approach for the calculation of nuclear magnetic resonance shielding tensors to magnetic fields which couple not only to orbital but also spin degrees of freedom. This leads to a formulation in which the electron density, the induced paramagnetic current, and the induced spin-magnetization density are calculated separately for the individual subsystems. This is particularly useful for the inclusion of environmental effects in the calculation of nuclear spin-spin coupling constants. Neglecting the induced paramagnetic current and spin-magnetization density in the environment due to the magnetic moments of the coupled nuclei leads to a very efficient method in which the computationally expensive response calculation has to be performed only for the subsystem of interest. We show that this approach leads to very good results for the calculation of solvent-induced shifts of nuclear spin-spin coupling constants in hydrogen-bonded systems. Also for systems with stronger interactions, frozen-density embedding performs remarkably well, given the approximate nature of currently available functionals for the non-additive kinetic energy. As an example we show results for methylmercury halides which exhibit an exceptionally large shift of the one-bond coupling constants between {sup 199}Hg and {sup 13}C upon coordination of dimethylsulfoxide solvent molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water confined in carbon nanotubes: Magnetic response and proton chemical shieldings

We study the proton nuclear magnetic resonance ({sup 1}H-NMR) of a model system consisting of liquid water in infinite carbon nanotubes (CNT). Chemical shieldings are evaluated from linear response theory, where the electronic structure is derived from density functional theory (DFT) with plane-wave basis sets and periodic boundary conditions. The shieldings are sampled from trajectories generated via first-principles molecular dynamics simulations at ambient conditions, for water confined in (14,0) and (19,0) CNTs with diameters d = 11 {angstrom} and 14.9 {angstrom}, respectively. We find that confinement within the CNT leads to a large ({approx} -23 ppm) upfield shift relative to bulk liquid water. This shift is a consequence of strongly anisotropic magnetic fields induced in the CNT by an applied magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Induction Sensors for Detecting Anomalous Shielding of Radiological and Nuclear Materials: A Feasibility Study

This study examined a concept for improving the nation's ability to detect unauthorized transport of radiological and nuclear material that involves detecting not the radiological or nuclear material itself, but rather the anomalous presence of materials, such as lead and tungsten, typically used to shield such illicit materials from detection. Specifically, the project studied a potentially inexpensive, non-intrusive, and fast method of detecting anomalous shielding: use of magnetic induction sensors to measure currents induced in conductors by a driver coil. The first phase of this work, documented in this report, identified the signatures of materials of interest, assessed the usefulness of measured signatures for discrimination between materials, and then benchmarked models and calculations. The next task involved assessing the strength of these signatures when the materials of interest were enclosed within other materials, such as aluminum and steel, of various thicknesses. A final task mimicked a real-world scenario by testing the ability to detect material signatures of interest at a scale of a vehicle or cargo vessel against a cluttered backdrop, with and without the shielding of another material, such as aluminum or steel. This final task raised doubts regarding whether this detection scheme will be useful under real-world conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning Validation of CLAS-12 Torus Magnet Protection and Cryogenic Safety System

This paper provides an overview of the CLAS12 Torus magnet electromagnetic loss and energy balance in the magnet system and impact on the cryogenics system during an event of a fast dump and quench, as part of the commissioning activities within Hall B for the 12 GeV Accelerator Upgrade project at Jefferson Lab in November 2016. Test carried out validates the design of torus magnet protection and cryogenic safety system. This magnet is unique in that it comprises 6 superconducting coils which are individually conduction-cooled by helium, thereby providing an element of thermal and mechanical decoupling between the coils. Lastly, as such its behavior under a fast dump condition (and even a quench) is markedly different from that of more conventional bath-cooled superconducting magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

Multi-winding homopolar electric machine

A multi-winding homopolar electric machine and method for converting between mechanical energy and electrical energy. The electric machine includes a shaft defining an axis of rotation, first and second magnets, a shielding portion, and a conductor. First and second magnets are coaxial with the shaft and include a charged pole surface and an oppositely charged pole surface, the charged pole surfaces facing one another to form a repulsive field therebetween. The shield portion extends between the magnets to confine at least a portion of the repulsive field to between the first and second magnets. The conductor extends between first and second end contacts and is toroidally coiled about the first and second magnets and the shield portion to develop a voltage across the first and second end contacts in response to rotation of the electric machine about the axis of rotation.

30 DIRECT ENERGY CONVERSION↗

Magnetic Sensitivity of AlMn TESes and Shielding Considerations for Next-Generation CMB Surveys

In the next decade, new ground-based cosmic microwave background (CMB) experiments such as Simons Observatory, CCAT-prime, and CMB-S4 will increase the number of detectors observing the CMB by an order of magnitude or more, dramatically improving our understanding of cosmology and astrophysics. These projects will deploy receivers with as many as hundreds of thousands of transition edge sensor (TES) bolometers coupled to superconducting quantum interference device (SQUID)-based readout systems. It is well known that superconducting devices such as TESes and SQUIDs are sensitive to magnetic fields. However, the effects of magnetic fields on TESes are not easily predicted due to the complex behavior of the superconducting transition, which motivates direct measurements of the magnetic sensitivity of these devices. We present comparative four-lead measurements of the critical temperature versus applied magnetic field of AlMn TESes varying in geometry, doping, and leg length, including Advanced ACT and POLARBEAR-2/Simons Array bolometers. MoCu ACTPol TESes are also tested and are found to be more sensitive to magnetic fields than the AlMn devices. We present an observation of weak-link-like behavior in AlMn TESes at low critical currents. We also compare measurements of magnetic sensitivity for time division multiplexing SQUIDs and frequency division multiplexing microwave (mMUX) rf-SQUIDs. We discuss the implications of our measurements on the magnetic shielding required for future experiments that aim to map the CMB to near-fundamental limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A magnetic field cloak for charged particle beams

Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. In this study, we demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the momentum measurements of charged final state particles at angles close to the beam line and therefore increase the physics reach of these experiments. In contrast to other magnetic shielding options (such as active coils), a cloak requires no external powering. We discuss the design parameters, fabrication, and limitations of a magnetic field cloak and demonstrate that cylinders made from 45 layers of YBCO high-temperature superconductor, combined with a ferromagnetic shell made from epoxy and stainless steel powder, shield more than 99% of a transverse magnetic field of up to 0.45 T (95% shielding at 0.5 T) at liquid nitrogen temperature. Lastly, the ferromagnetic shell reduces field distortions caused by the superconductor alone by 90% at 0.45 T.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact, Low-Cost, Light-Weight, Superconducting, Ironless Cyclotrons for Hadron Radiotherapy

Superconducting cyclotrons are increasingly employed for proton beam radiotherapy treatment (PBRT). The use of superconductivity in a cyclotron design can reduce its mass by an order of magnitude and size by a factor of 3-4 over conventional resistive magnet technology, yielding significant reduction in overall cost of the device, the accelerator vault, and its infrastructure, as well as reduced operating costs. At MIT, previous work was focused on developing a very high field (9 T at the pole face) superconducting synchrocyclotron that resulted in a highly compact device that is about an order of magnitude lighter, and much smaller in diameter than a conventional, resistive cyclotron. The results of the study reported here were focused on a conceptual design for a compact superconducting synchrocyclotron to demonstrate the possibility to further reduce its weight by almost another order of magnitude by eliminating all iron from the device. In the absence of magnetic iron poles, the magnetic field profile in the beam gap is achieved through a set of main superconducting split pair coils energized in series with a set of distributed field-shaping superconducting coils. External magnetic field shielding is achieved through a set of outer, superconducting ring coils, also connected in series with the other coils, to cancel the stray magnetic field. These shielding coils replace the heavy iron yoke which is the conventional method to return the magnetic flux. It is noted that the 10 Gauss surface is located at a radius of about 3.5 m comparable in both ironless and conventional devices, even in the absence of iron in the ironless device. An important result from eliminating all magnetic iron in the flux circuit is the resulting linear relationship between the operating current and the magnetic field intensity. In the case with iron, the saturation of the magnetic field forces operation at one value of magnetic field. This feature design then enables continuous beam energy variation without the use of an energy degrader, thus eliminating secondary radiation during the in-depth beam scanning, increasing the ion current delivered to the patient and improving the beam quality. The beam energy is determined by the magnetic field strength at the extraction radius, and changing the field enables selection of the final beam energy. The magnetic field can be adjusted while maintaining the needed radial field profile.

Minervini, Joseph V.↗

X-ray Emission from Electron Betatron Motion in a Laser-Plasma Accelerator

Single-shot x-ray spectra from electron bunches produced by a laser-plasma wakefield accelerator (LPA) were measured using a photon-counting single-shot pixelated Silicon-based detector [3], providing for the first time direct spectra without assumptions required by filter based techniques. In addition, the electron bunch source size was measured by imaging a wire target, demonstrating few micron source size and stability. X-rays are generated when trapped electrons oscillate in the focusing field of the wake trailing the driver laser pulse. In addition to improving understanding of bunch emittance and wake structure, this provides a broadband, synchronized femtosecond source of keV x-rays. Electron bunch spectra and divergence were measured simultaneously and preliminary analysis shows correlation between x-ray andelectron spectra. Bremsstrahlung background was managed using shielding and magnetic diversion.

43 PARTICLE ACCELERATORS↗

Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/MR system

In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is {approx}0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional magnetic field that is superimposed on the original field of the MR scanner. Even after linear shimming, the field homogeneity of the MR scanner remains disrupted by the detector. The authors characterize the field due to the detector with the field of two magnetic dipoles and further show that two sets of permanent magnets (NdFeB) can withstand the main magnetic field and compensate for the nonlinear components of the additional field. The ideal number of magnets and their locations are calculated based on a field map measured with the detector in place. Experimental results demonstrate great promise for this technique, which may be useful in many settings where devices with magnetic components need to be placed inside or close to an MR scanner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-145: Effects of Temporary Tachytherapy Inhibition Magnet On MOSFET Dose Measurements of Cardiovascular Implantable Electronic Devices (CIED) in Radiation Therapy Patients

Purpose: To determine the effects of temporary tachytherapy inhibition magnet on MOSFET dose measurements of cardiovascular implantable electronic devices (CIED) in radiation therapy patients. Methods: Infield and peripheral MOSFET dose measurements with 6MV photon beams were performed to evaluate dose to a CIED in the presence of a doughnut shaped temporary tachytherapy inhibition magnet. Infield measurements were done to quantify the effects of the magnetic field alone and shielding by the magnet. MOSFETs were placed inside a 20×20cm{sup 2} field at a depth of 3cm in the isocentre plane in the presence and absence of the magnet. Peripheral dose measurements were done to determine the impact of the magnet on dose to the CIED in a clinical setting. These measurements were performed at the centre, under the rim and half way between a 10×10cm{sup 2} field edge and the magnet with MOSFETS placed at the surface, 0.5cm and 1cm depths in the presence and absence of the magnet. Results: Infield measurements showed that effects of magnetic field on the MOSFET readings were within the 2% MOSFET dose measurement uncertainty; a 20% attenuation of dose under the magnet rim was observed. Peripheral dose measurements at the centre of the magnet show an 8% increase in surface dose and a 6% decrease in dose at 1cm depth. Dose under the magnet rim was reduced by approximately 68%, 45% and 25% for MOSFET placed at 0.0, 0.5 and 1.0cm bolus depths, respectively. Conclusions: The magnetic field has an insignificant effect on MOSFET dose measurements. Dose to the central region of CIED represented by centre of the magnet doughnut increases at the surface, and decreases at depths due to low energy scattering contributions from the magnet. Dose under the magnet rim, representing CIED edges, decreased significantly due to shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of magnetic field in plume region on the performance of multi-cusped field thruster

The performance characteristics of a Multi-cusped Field Thruster depending on the magnetic field in the plume region were investigated. Five magnetic field shielding rings were separately mounted near the exit of discharge channel to decrease the strength of magnetic field in the plume region in different levels, while the magnetic field in the upstream was well maintained. The test results show that the electron current increases with the decrease of magnetic field strength in the plume region, which gives rise to higher propellant utilization and lower current utilization. On the other hand, the stronger magnetic field in the plume region improves the performance at low voltages (high current mode) while lower magnetic field improves the performance at high voltages (low current mode). This work can provide some optimal design ideas of the magnetic strength in the plume region to improve the performance of thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗