Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Study of Conduction-Cooled Superconducting Quadrupole Magnets Combined with Dipole Correctors for the ILC Main Linac

A superconducting rf (SRF) cryomodule for International Linear Collider(ILC) Main Linac equips focus/steering magnets. The magnets are "superferric" magnets with four superconducting (SC) race track coils conductively cooled from the cryomodule LHe supply pipe. The quadrupole field gradient and dipole field are 40 T/m and 0.1 T, respectively. The magnet length and iron-pole radius are 1 m and 0.045 m, respectively. It is known that dark current is generated at SRF cavities and accelerated through the following linac string. The dark current reaches and heats the SC magnets. It is estimated that the power deposition in the magnet may reach more than a few watts and temperature of the SC coils may locally reach to critical temperature of NbTi. It is important to make the magnet not reach quench with sufficient conduction cooling. We aim to realize the SC magnet which can stably operate under such condition. We plan to develop test coils made of three types of SC materials, NbTi, Nb₃Sn, and MgB₂ and study thermal characteristics and stability . We will develop a short model magnet, based on the test coil results. Here, we will present the magnet design study and the R&D plan.

43 PARTICLE ACCELERATORS↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Erosion and impurity transport for the edge localized mode suppression window in KSTAR

A 3D analysis of plasma wall interactions and global impurity transport for the edge localized mode suppression window in KSTAR during H-Mode discharges has shown that carbon erosion at the divertor plates is a strong function of the resonant magnetic perturbation (n = 1) coil current and relative phasing. The Generalized Perturbation Equilibrium Code was used to determine a realistic initial perturbed plasma equilibrium, and EMC3-EIRENE was used to calculate the resulting scrape-off layer plasma used in this study as a fixed background for the ERO2.0 plasma–material interaction model. The resulting transport leads to deposition of impurities along the targets positioned at the high-field side of the device. An attempt at calculating the resulting effective charge state has demonstrated a similar dependence on the perturbation coil current and has been able to determine a window for the experimentally observed values of Zeff by including contributions of all ionized carbon charge states and deuterium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying the microtearing modes in the pedestal of DIII-D H-modes using gyrokinetic simulations

Recent evidence points toward the microtearing mode (MTM) as an important fluctuation in the H-mode pedestal for anomalous electron heat transport. A study of the instabilities in the pedestal region carried out using gyrokinetic simulations to model an ELMy H-mode DIII-D discharge (USN configuration, 1.4 MA plasma current, and 3 MW heating power) is presented. The simulations produce MTMs, identified by predominantly electromagnetic heat flux, small particle flux, and a substantial degree of tearing parity. The magnetic spectrogram from Mirnov coils exhibits three distinct frequency bands—two narrow bands at lower frequency (~35–55 kHz and ~70–105 kHz) and a broader band at higher frequency (~300–500 kHz). Global linear GENE simulations produce MTMs that are centered at the peak of the ω* profile and correspond closely with the bands in the spectrogram. The three distinctive frequency bands can be understood from the basic physical mechanisms underlying the instabilities. For example (i) instability of certain toroidal mode numbers (n) is controlled by the alignment of their rational surfaces with the peak in the ω* profile, and (ii) MTM instabilities in the lower n bands are the conventional collisional slab MTM, whereas the higher n band depends on curvature drive. While many features of the modes can be captured with the local approximation, a global treatment is necessary to quantitatively reproduce the detailed band gaps of the low-n fluctuations. Notably, the transport signatures of the MTM are consistent with careful edge modeling by SOLPS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Technical Report: Innovative Magnetron Power Sources for Superconducting RF (SRF) Accelerators

In this project, MUONS is designing and building custom magnetrons at Richardson Electronics (RELL) to test the predictions of the models and make improvements to the designs to match the needs of NP SRF accelerators and their life-cycle costs. To increase lifetime, the filament temperature is controlled by a feedback circuit that includes a model of back streaming of electrons. The gain of the magnetron is optimized by the design of an input port. A permanent magnet design with trim coil for amplitude adjustment reduces energy consumption. Moving the construction of the magnetron from prototype to manufacturing includes the utilization of RELL processes and designs. To the extent that outgassing of materials influences the lifetime of the magnetron, methods for minimizing outgassing was explored. Further experimentation of the potential of sub-critical voltage operation continues to be explored. The commercialization goal of the project will be naturally achieved as RELL already has world-wide marketing, sales, and support to exploit the assembly-line capabilities generated by this project to enable magnetron technologies for NP accelerators.

43 PARTICLE ACCELERATORS↗

Making Wireless Power Matter (CRADA Final Report)

The Resonant Link project team investigated the integration of their novel, self-resonant magnetic structure for electromagnetic coils into inductive wireless power transfer systems. Relative to conventional wireless power coils, their multi-layer self-resonant structure (the “MSRS”) reduces losses by up to 6x and lowers to BOM cost by up to 10x. These power-dense, cost-effective coils are a promising path towards the first value-add wireless power systems in a variety of applications, from phones to medical devices to kitchen appliances to mobile robots to electric vehicles. The researchers explored development of the power electronics for wireless power transfer systems using the multi-layer self-resonant structure (MSRS) concept that efficiently transmits power over air gaps for in-home applications, including through-wall power transfer, appliances built around the Ki and Qi standards, and other potential use cases This project specifically focused on the power electronics design, development, and testing for these applications. Resonant Link’s proprietary wireless power technology holds the promise of matching the performance of wired chargers in size and efficiency, especially when operated from a DC distribution grid.

42 ENGINEERING↗

A new ductile, tougher resin for impregnation of superconducting magnets

A major remaining challenge for Nb 3 Sn high field magnets is their training due to random temperature variations in the coils. The main objective of our research is to reduce or eliminate it by finding novel impregnation materials in replacement of the epoxies currently used. An organic olefin-based thermosetting dicyclopentadiene resin, C 10 H 12 , commercially available in Japan as TELENE® by RIMTEC, was used to impregnate a short Nb 3 Sn undulator coil developed by ANL and FNAL. This magnet reached short sample limit after only two quenches, compared with ∼100 when CTD-101K® was used. Ductility, i.e. the ability to accept large strains, and toughness were identified as key properties to achieve these results. In addition, we have been investigating whether mixing TELENE with high heat capacity ceramic powders such as Gd 2 O 3 , Gd 2 O 2 S, and HoCu 2 , increases the specific heat (C p ) of impregnated Nb3Sn superconducting magnets. The viscosity, heat capacity, thermal conductivity, and other physical properties of TELENE with high-C p powder fillers were measured in this study as a function of temperature and magnetic field. The TELENE-87 wt%Gd 2 O 2 S had a peak in C p between 4.3 K and 5.3 K at fields between 0 and 8 T. We have also investigated the effect on the mechanical properties of pure and mixed TELENE under 10 MGy of gamma ray irradiation at the Takasaki Advanced Radiation Research Institute in Takasaki, Japan. TELENE-87 wt%Gd 2 O 2 S exhibited exceptional radiation resistance. Impregnating an undulator coil with TELENE mixed with Gd 2 O 2 S powder will verify whether the coils' thermal stability further improves, or whether its low diffusivity will require engineering the material with high-thermal conductivity components. Short magnet training will lead to better magnet reliability, lower magnet margins, lower risk and substantial saving in accelerators' commissioning costs. Part of this study is supported by the U.S.-Japan Science and Technology Cooperation Program in high energy physics operated by MEXT in Japan and DOE in the U.S.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗

Double Aperture HTS Dipole Magnet Model for the Persistent Current Operation

Particle accelerators use many different types of magnets. There is an interest in replacing rather low-field conventional resistive magnets with high-temperature superconducting (HTS) magnets. The main goal is to reduce operational expenses, which is critical during the continuously increasing cost of electricity. At Fermilab, several HTS accelerator magnets were built and successfully tested. The paper described a variant of the double-aperture dipole magnet that could be suitable for future Lepton Colliders. A single short-circuited HTS coil of 3.8 kA generates a homogeneous magnetic field of 57 mT in both magnet gaps of 84 mm. The short model magnet was designed, built, and successfully tested at liquid nitrogen temperature. This magnet works in a persistent current mode, which provides additional cost savings when used in particle storage rings operated at a stable magnetic field. The results of design, fabrication, and tests are presented and discussed. The magnet demonstrated a high magnetic field stability in both apertures, efficiency of correction coils, and primary powering circuit.

Kashikhin, Vladimir [Fermilab] (ORCID:000000017249↗

Final Design and Analysis of the Superconducting Magnets for the Material Plasma Exposure Experiment

The Material Plasma Exposure eXperiment (MPEX), which has completed its final design, is a new linear plasma device to advance the understanding of plasma-material interactions through the generation and delivery of plasmas as they are expected in future fusion reactor divertors. MPEX will be a steady-state device to study high-fluence exposures of plasma-facing materials and components. The requirements for the magnetic field at the heating stages and the target make the application of superconducting coils necessary. The final designs for the superconducting magnets have been developed using three cryostat designs with warm bore diameters of 65 cm and 156 cm. The large bores are required to for other systems such as vacuum, water cooling, and RF power. There are 19 superconducting coils in MPEX that are contained in six cryostats. Although design, fabrication, and testing for the magnets as stand-alone units are straightforward, challenges will arise during the integration of the system. Various field profiles will be used during operation. The magnetic field where the electron cyclotron heating occurs needs to operate at both 1.25 and 2.50 T. Analyses that have been performed on the final design include designing the coils and determining operating currents to meet field requirements, forces between cryostats, the effects of coil and/or cryostat movement, and quench analysis. To ensure that the magnetic field requirements are met, a plan for monitoring the magnetic field at specified locations has been developed which includes the effect of coil and/or cryostat movement.

Burkhardt, Earle↗

An adjoint method for determining the sensitivity of island size to magnetic field variations

An adjoint method to calculate the gradient of island width in stellarators is presented and applied to a set of magnetic field configurations. The underlying method for calculation of the island width is that of Cary & Hanson ( Phys. Fluids B, vol. 3, issue 4, 1991, pp. 1006–1014) (with a minor modification), and requires that the residue of the island centre be small. Therefore, the gradient of the residue is calculated in addition. Both the island width and the gradient calculations are verified using an analytical magnetic field configuration introduced by Reiman & Greenside ( Comput. Phys. Commun. , vol. 43, issue 1, 1986, pp. 157–167). The method is also applied to the calculation of the shape gradient of the width of a magnetic island in a National Compact Stellarator Experiment (NCSX) vacuum configuration with respect to positions on a coil. A gradient-based optimization is applied to a magnetic field configuration studied by Hanson & Cary ( Phys. Fluids , vol. 27, issue 4, 1984, pp. 767–769) to minimize stochasticity by adding perturbations to a pair of helical coils. Although only vacuum magnetic fields and an analytical magnetic field model are considered in this work, the adjoint calculation of the island width gradient could also be applied to a magnetohydrodynamic (MHD) equilibrium if the derivative of the magnetic field, with respect to the equilibrium parameters, is known. Using the island width gradient calculation presented here, more general gradient-based optimization methods can be applied to design stellarators with small magnetic islands. Moreover, the sensitivity of the island size may itself be optimized to ensure that coil tolerances, with respect to island size, are kept as high as possible.

Physics↗

Simulated thermonuclear performance of auto-magnetizing helical liner MagLIF target implosions

Magnetized liner inertial fusion (MagLIF) implosions on the Z accelerator require magnetization of the fuel to reduce thermal conduction losses of energy from the laser-preheated deuterium fusion fuel to the surrounding liner material. While external field coils traditionally used to axially magnetize MagLIF targets are limited to 10–20 T (or perhaps ∼ 30 T with technological development), calculations suggest that higher axial magnetic fields would improve thermal insulation of the fuel and improve MagLIF target performance. We present results from three-dimensional radiation-magnetohydrodynamic simulations of MagLIF implosions employing auto-magnetizing helical liners composed of discrete metallic helical conduction paths separated by electrically insulating material. These simulated auto-magnetizing (AutoMag) liners produce axial magnetic fields >30 T inside the fusion fuel prior to implosion. Simulations indicate that higher thermonuclear yields and burn-averaged fuel ion temperatures are attained for implosions using AutoMag liners compared to standard MagLIF implosions. Comparable implosion morphology is evident in synthetic x-ray images of AutoMag–MagLIF and standard MagLIF implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

Verification of the Shafranov shift in free-boundary VMEC, DESC, and SPEC calculations with elliptical geometry

Here, given a set of current-carrying filaments that create a magnetic field with rotating elliptical flux surfaces, we present verification calculations using the VMEC, DESC, and SPEC free-boundary magnetohydrostatic equilibrium codes for both the “vacuum” equilibrium, for which there is no plasma pressure and no plasma currents, and for a non-zero pressure, zero toroidal current equilibrium. For the vacuum case, these codes are quantitatively compared to the magnetic field produced by the coils. For the non-zero pressure case, they are compared to each other. As the stepped pressure profile used in SPEC approaches the continuous profile used in VMEC and DESC, the SPEC magnetic axis approaches the VMEC and DESC axes. To within an error given by the difference between the pressure profiles, the VMEC, DESC, and SPEC calculations give the same pressure-induced geometric shift of the magnetic axis, known as the Shafranov shift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗