Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flow Strength Measurements of Wrought and AM SS304L via Pressure Shear Plate Impact Experiments

Pressure-shear plate impact experiments were performed to quantify flow strength of wrought, as-built additively manufactured (AM), and heat-treated and recrystallized AM 304 L stainless steel (SS304L) under combined loading. Impact velocities spanned between 0.03 and 0.24 mm/μs, resulting in corresponding pressures of 0.62–5.93 GPa. Flow strength measurements are comparable for the sample variants across the studied loading conditions; however, shear wave structures significantly differ between sample type. Microstructurally aware simulations indicate local strain differences attributed to anisotropic elastic constants of large grains (~1 mm) in the as-built and heat-treated AM may impede the ability to uniformly transmit a shear wave.

36 MATERIALS SCIENCE↗

Investigation of Nonlinear Difference-Frequency Wave Excitation on a Semisubmersible Offshore-Wind Platform with Bichromatic-Wave CFD Simulations: Preprint

The natural surge and pitch frequencies of semisubmersible offshore wind platforms are typically designed to be below the wave frequencies to avoid direct excitation. However, surge or pitch resonance can be excited by the nonlinear low-frequency loads generated by irregular incident waves. Second-order potential-flow models with added Morison drag have been found to underpredict this low-frequency excitation and response. As part of the OC6 project, Computational Fluid Dynamics (CFD) simulations were performed to enable a better understanding of the low-frequency loads and the limitations of lower-fidelity models. The focus of the current paper is to set up a computationally cost-effective CFD simulation of a fixed semisubmersible platform to investigate nonlinear difference-frequency loads and establish the corresponding uncertainty in the results. Due to the high computing cost, CFD simulations of irregular waves can be challenging. Instead, simulations were performed with bichromatic waves having a shorter repeat period. A preliminary comparison with Quadratic Transfer Functions from second-order potential-flow theory shows that CFD models consistently predict higher nonlinear wave loads at the difference frequency, likely due to flow separation and viscous drag not accounted for in potential-flow theory.

2nd order↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Scalable Risk Assessment of Rare Events in Power Systems With Uncertain Wind Generation and Loads

Risk assessment of rare events has become increasingly important in power system planning and operation with the increasing integration of renewable energy and the presence of system uncertainties. However, quantifying the risk posed by rare events via the traditional method, i.e., Monte Carlo sampling (MCS), incurs substantial computational expense stemming from the vast ensemble of power flow simulations. To accelerate the assessment, this paper proposes a Deep Neural Network (DNN)-kernelized vector-valued Gaussian Process (VVGP) approach with excellent computational efficiency while maintaining high accuracy. Consequently, serving as a surrogate model for the power flow solver, the DNN-kernelized VVGP enables significantly faster but accurate risk assessment compared to the power flow solver. The developed surrogate model evaluates low-order N - k events that contain more than 90% instances by adeptly capturing the topological features while the high-order N - k events are assessed via a power flow solver, thereby striking a balance between computational efficiency and uncertainty quantification accuracy. Moreover, the model incorporates a Support Vector Machine (SVM) classifier to resample concerning low-probability tail events to counteract the biases potentially introduced during the DNN-kernelized VVGP evaluations. Simulations conducted on the modified IEEE 24-bus, 118-bus, and European 1354-bus systems demonstrate that the proposed method maintains the accuracy benchmark set by MCS while significantly reducing computational demands in large-scale power systems as compared to other state-of-the-art methods.

17 WIND ENERGY↗

Compressible pairwise interaction extended point-particle model for force prediction of shock-particle bed interaction

We propose a pairwise influence framework for the complex unsteady compressible particle-laden flow problem by accounting for the scattered hydrodynamic waves emitting from neighboring particles in a Euler-Lagrange simulation. It has been observed from particle-resolved (PR) simulations of randomly dispersed particle beds under a loading shock that the compressible pseudoturbulence dominates the flow system even after the primary shock has passed, which causes fluctuations observed in the forces experienced by the particle. Moreover, the fact that each particle exists in the vicinity of a random arrangement of other particles modifies the time history of the drag force experienced by each particle during and after the passage of the shock. First, the scattering flow field due to an incoming shock interacting with a single sphere is constructed using an analysis of the flow in the acoustic limit. Then we examine the validity of the compressible Maxey-Riley-Gatignol force model by comparing the force prediction against a PR simulation of two interacting particles for various particle arrangements and incoming shock strength. Subsequently, the neighboring influences are stored as a library of maps that can be used readily in the calculation of the perturbation force. Lastly, the pairwise interaction assumption is evaluated by comparing the force predicted with the model with PR simulations of a randomly packed particle bed of 10% volume fraction for both water and air as the fluid medium for an incoming shock Mach number 1.22. With a considerably lower cost for the implementation of the model compared to PR simulations, it is verified that the model is reasonably accurate in pinpointing particles whose peak force is significantly larger or smaller than the mean drag but also to capture the prolonged fluctuations after the initial shock.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling Offshore Wind Farm Performance in Coastal Low-Level Jets Using Coupled Mesoscale-Microscale Large Eddy Simulations

Accurately predicting wind farm reliability under complex offshore atmospheric conditions remains a key challenge, particularly during noncanonical meteorological events such as coastal low-level jets (LLJs). LLJs, characterized by strong nonmonotonic vertical shear and directional veer, depart significantly from the simplified inflow assumptions embedded in conventional design standards, low-fidelity engineering models, and microscale large eddy simulations of the atmospheric boundary layer. In this work, we use the virtual wind farm framework—an exascale, graphics processing unit–accelerated large eddy simulation platform coupled with high-fidelity aeroservoelastic turbine models and advanced mesoscale-microscale coupling via the ExaWind software stack—to investigate turbine responses under realistic LLJ forcing. Simulations are performed over the U.S. North Atlantic offshore domain with the use of meteorological inputs from New York State Energy Research and Development Authority buoy data, focusing on a representative LLJ case impacting the International Energy Agency 15 MW reference turbine. Our results show that LLJs can cause up to 50% power deficits in downstream turbine rows and significantly amplify low-speed shaft and tower loads through nonlinear coupling between complex inflow characteristics and turbine structural dynamics. Two primary mechanisms drive these load amplifications: (1) unique LLJ inflow features—including veer and vertical/lateral shear—and (2) the downstream evolution of the flow under stable thermal stratification, which suppresses turbulence mixing and alters wake recovery. These mechanisms produce streamwise variations in turbine loading not captured by standard hub height–based metrics or existing design load case (DLC) definitions. This study highlights the critical role of rotor-scale flow gradients in driving fatigue and system-level aeroelastic responses, challenging current DLC and control strategies. We advocate the integration of full-flow field, environment-aware wind inputs into load modeling and control algorithms. By leveraging exascale computing to resolve mesoscale-microscale coupling, this work lays the groundwork for next-generation offshore wind turbine design and operation in meteorologically complex marine environments.

17 WIND ENERGY↗

Experimental, numerical and analytical evaluation of j × B -thrust for fast-liquid-metal-flow divertor systems of nuclear fusion devices

Abstract Divertor systems of fusion devices are exposed to intense heat loads from plasmas, which degrade solid plasma-facing components. Fast liquid metal (LM) flow divertors may be more advantageous for this purpose but have risk of piling due to intense magnetohydrodynamic (MHD) drag. However, severe deceleration of the flow could be countered with the injection of currents that are transverse to external magnetic fields, allowing to thrust the flow with j × B (Lorentz) forces. Given that the injection of currents as an approach to propel LM-divertor flows has remained experimentally understudied, this article focuses on the evaluation of j × B -thrust and finding its drawbacks. j × B -thrust was experimentally tested with free-surface-LM flows, a vertical magnetic field and an externally applied current. Experiments were reviewed with a theoretical model, showing agreement in the trends of theory and experiments. Full 3D-MHD-free-surface-flow simulations were also performed with FreeMHD and confirmed the sensitivity to unstable flow behavior in LM systems when applying external currents. Furthermore, excessive power requirements are expected for the implementation of j × B -thrust at the reactor scale, making these systems inefficient for commercial devices. This paper evidences that the simple operation of a LM-flow divertor with j × B -thrust, without any of the instabilities caused from reactor plasmas or parasitic currents, already presents intrinsic challenges.

Magnetohydrodynamics↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Blade Strain Measurements and Fatigue Analysis of a Cross-Flow Turbine Operating in a Tidal Flow

Cross-flow turbines (CFTs) are inherently unsteady devices with regards to operating principle and loading. By improving our understanding of the dynamic loading on these turbines, we hope to better inform CFT design, improve survivability, and reduce overall costs. The University of New Hampshire (UNH) and the National Renewable Energy Laboratory (NREL) collaborated on a project to instrument and test a four-bladed New Energy Corp. vertical axis cross-flow turbine in a real tidal flow. One blade from the 3.2 m diameter x 1.7 m height turbine was instrumented with eight full-bridge strain gauges along the span of the blade. The turbine was then deployed at the UNH-Atlantic Marine Energy Center (AMEC) Tidal Energy Test Site in Portsmouth, NH. Time-synchronized measurements of blade strain, inflow, thrust, rotational speed, and electrical output were obtained to characterize blade loading under various conditions. The blade strain was examined to assess the dynamic loading and conduct a fatigue analysis on the device.

blade strain↗

Unsteady aerodynamics of large-scale floating offshore wind turbines in surge motion

Unsteady aerodynamic loads significantly influence the design and wake flow field of floating offshore wind turbines, especially due to wave- or vibration-induced tower top motions triggering various unsteady phenomena. Recent studies show that increasing turbine sizes amplify unsteady aerodynamic effects, as their impact typically grows with rotor diameter. This work combines recent findings from experiments and simulations on model-scale FOWT aerodynamics with new numerical analyses of large-scale rotors, providing a comprehensive understanding of unsteady phenomena occurrence and impact. Numerical analyses of the IEA 15-MW and 22-MW rotors undergoing surge motions characterise the combined influence of motion-induced unsteady phenomena on rotor thrust. Results indicate that unsteady effects can reduce thrust force variations by up to 40% at realistic surge periods. These findings contrast with prior model-scale rotor investigations, attributed to the specialised design of the model rotors. Comparisons between numerical methods - the dynamic blade element momentum method in OpenFAST and free vortex wake modules in panMARE and OpenFAST - reveal persistent differences in thrust predictions under both idealised and realistic conditions. This highlights that classical blade element momentum approaches require enhancement to accurately capture unsteady loads on large-scale floating offshore wind turbines at low wind speeds.

16 TIDAL AND WAVE POWER↗

Numerical Modeling of a Two-Stage Ocean Current Turbine

The Equinox Ocean Turbines (EQOT) current energy converter has a unique design with power generation in two small-diameter turbines attached to the tips of a large-diameter passive rotor. This configuration offers some key advantages for capturing ocean currents. With no centrally placed generator, almost no reaction torque is required at the nacelle of the main large-diameter rotor, and the small-diameter tip turbine generators operate at a higher speed and lower torque. The physics that determine the performance and loads on the turbine are also unique. The interactions of the flow field between the two stages and the general architecture of the system cannot be captured with traditional mid-fidelity modeling tools. For design iterations and large sets of load cases, it is important to have mid-fidelity models that can capture the important phenomenon with enough accuracy to identify global trends. This work uses a limited set of high-fidelity computational fluid dynamics (CFD) simulations to help inform the selection of and construction of a custom mid-fidelity model. Mid-fidelity modeling approaches were verified by comparing key turbine performance quantities to those found with the CFD model. Hydrodynamic interactions of the two-stage rotor were identified through high-fidelity CFD modeling. This highlighted the impact of the main rotor tip vortex and wake on the secondary rotor apparent inflow. This results in a relative flow rotation and sharp deficit, that change the optimal secondary rotor rotation speed and adds unsteadiness to the blade loading respectively. Multiple mid-fidelity approaches were evaluated for their ability to capture these effects. A simple approximation of the combined-stage performance based on single-stage BEM provides a reasonable rough prediction, especially near the peak TSR values, with some larger discrepancy at higher TSRs. Predicting the combined-stage performance based on single-stage CFD data improves this prediction across the TSR range. Although the combined-stage modeling in OLAF was not successful in this stage of the project, it showed promise as a mid-fidelity method, assuming the parameters can be tuned to account for the significant differences in time and length scales between the main and secondary rotors. This may be addressed through code changes in future work. A significant finding from the OLAF work was the agreement between the vortex core radius values found independently via a parameter space search and via CFD. The technique of using single-stage secondary rotor BEM, with a custom inflow taken from single-stage main rotor CFD or OLAF, provides an efficient method to capture one-way coupled flow interactions. This method provided generally good predictions of the impact of the flow rotation on the secondary rotor but struggled to accurately predict the peaks of the unsteady load progression. Future work could include some superposition of a tuned main rotor trailing edge viscous wake into the custom inflow to better predict this interaction.

16 TIDAL AND WAVE POWER↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A time‐varying formulation of the curled wake model within the FAST.Farm framework

Abstract In this article, we present a time‐varying formulation of the curled wake model that we implemented in FAST.Farm. The curled wake model, originally developed for steady‐state conditions, is used to produce realistic wake profiles behind a wind turbine in yawed (or skewed) conditions. We begin by introducing the key elements of the FAST.Farm framework. Then, after briefly summarizing the original wake dynamics formulation of FAST.Farm based on a polar wake profile, we present the new time‐varying formulation of the curled wake model, compare the two, and highlight the differences with the original curled wake model. After discussing some implementation details, we present different applications with increasing levels of complexity: single turbine with uniform and turbulent inflow, fixed and transient yaw, and multiple turbines. We verify our results using the original FAST.Farm implementation and large‐eddy simulations. The results with the new curled wake model are improved compared to the original implementation, as they include cross‐flow velocities and wake asymmetry. Yet, large‐eddy simulation results show a more pronounced lateral convection of the wake and a stronger concentration of vorticity at the top vortex. The new curled wake implementation in FAST.Farm should enable the calculation of not only generator power but also wind turbine structural loads for applications involving intentional or unintentional skewed flow and wind‐farm control involving wake steering.

17 WIND ENERGY↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗