Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Leak Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Quantifying Methane Leak Emissions by Fused Airborne Imaging Spectroscopy with in Situ Surface Mobile and Airborne Observations of a California Producing Oil Field

Methane (CH4) emission budgets remain uncertain and are projected to grow as oil and gas production from short-lived wells increases and their subsequent transport through aging gas distribution networks. Orders-of-magnitude variations in temporal, spatial, and emission scales present a key challenge to leak detection and quantification. Also, the probability distributions for large and stochastic, leaky systems such as geological reservoirs (by natural migration-seeps) and petroleum production from those reservoirs remain largely unknown, needed to address current approach limitations. The scale of many petroleum systems favors remote sensing, but the sensitivity of such systems often precludes detection of weak emissions. Consequently, an accurate evaluation requires that the relative contribution from the emission "tails" of small leaks also be quantified, which is best carried out using high-sensitivity in situ methods. Fusion of remote sensing and in situ approaches leverages complementary capabilities to address these limitations. We show results from mobile surface (AMOG) and airborne in situ (AJAX) and thermal-infrared (TIR) hyperspectral imaging spectroscopy (Mako) data applied to a producing oil field in the California Central Valley near Bakersfield. AMOG is an automobile-based mobile lab that measures 13 trace gases, aerosol size distributions and vertical profiles, 3D winds and other meteorology, and atmospheric column measurements by solar spectroscopy at highway speeds. AJAX measures 5 trace gases and 3D winds at ~140 m/s. Mako is a broad-area TIR imaging spectrometer that can discriminate multiple gases present in each pixel acquired. In situ-derived, total field emissions were 31±16 Gg/yr CH4. This was compared with Mako-derived emissions from all plumes identified across the study site. We found that super-emitters were not the dominant emissions mode and the spatial pattern of plume locations from production infrastructure was correlated to geological structures.

Leifer, Ira↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Portable detector set discloses helium leak rates

Portable helium detector measuring helium leak rates makes possible the use of the inert gas helium as a tracer. This helps solve safety and contamination problems in detecting leaks in closed fluid systems.

Anderson, G. E.↗

Gas Chromatic Mass Spectrometer

Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

Wey, Chowen↗

Optical Detection Of Cryogenic Leaks

Conceptual system identifies leakage without requiring shutdown for testing. Proposed device detects and indicates leaks of cryogenic liquids automatically. Detector makes it unnecessary to shut equipment down so it can be checked for leakage by soap-bubble or helium-detection methods. Not necessary to mix special gases or other materials with cryogenic liquid flowing through equipment.

Wyett, Lynn M.↗

Nondestructive leak testing

Method provides opportunity to effect repairs without compromising integrity of enclosed circuitry or mechanism by loss of atmosphere or by ingestion of foreign matter or gas. It is possible to detect leaks in modules which are sealed while fully evacuated, partially evacuated, or containing some form of gas.

Lusby, T. K., Jr.↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Demonstration of rapid and sensitive module leak certification for Space Station Freedom

A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 (+ or -) 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 (+ or -) 0.7, -0.4 (+ or -) 0.3, and 76 (+ or -) 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on (Delta)p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc.

Dietz, R. N.↗

Detection of gaseous oxygen using temperature tuned laser diodes

The development of an optical differential absorption technique using laser diodes is discussed. The technique is being developed as a solution to overcome the difficulties imposed by conventional liquid rocket propulsion system leak detection such as damage to the engine, cumbersome equipment, and excessive amounts of time. The detection of O2 at atmospheric pressure and temperature using laser diodes is demonstrated. Also, it is shown that, by temperature tuning the laser diode, the wavelength was shifted to a level where the oxygen absorption peaks are found. The levels of transmission determined via experimental means and those calculated from spectral data are found to be in close agreement.

Fox, Curtis W.↗

Three Methods of Detection of Hydrazines

Three proposed methods for measuring trace quantities of hydrazines involve ionization and detection of hydrazine derivatives. These methods are intended to overcome the limitations of prior hydrazine- detection methods. Hydrazine (Hz), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) are hypergolic fuels and are highly reactive, toxic, and corrosive. A capability to measure concentrations of hydrazines is desirable for detecting leaks and ensuring safety in aerospace settings and in some industrial settings in which these compounds are used. One of the properties (high reactivity) that make it desirable to detect trace amounts of hydrazines also makes it difficult to detect hydrazines and measure their concentrations accurately using prior methods: significant amounts are lost to thermal and catalytic decomposition prior to detection. Further complications arise from the sticky nature of hydrazines: Sample hydrazine molecules tend to become irreversibly adsorbed onto solid surfaces with which they come into contact during transport to detectors, giving rise to drift in detector responses. In each proposed method, the reactive, sticky nature of hydrazines would be turned to advantage by providing a suitably doped substrate surface with which the hydrazines would react. The resulting hydrazine derivatives would be sufficiently less sticky and sufficiently more stable so that fewer molecules would be lost to decomposition or adsorption during transport. Consequently, it would be possible to measure concentration with more sensitivity and less error than in prior techniques. The first proposed method calls for the use of a recently developed technique known as desorption electrospray ionization (DESI), in which a pneumatically assisted micro -electrospray at ambient pressure is directed at a surface of interest. In this case, the surface of interest would be that of a substrate described above.

Griffin, Timothy↗

Microphone Detects Boiler-Tube Leaks

Unit simple, sensitive, rugged, and reliable. Diaphragmless microphone detects leaks from small boiler tubes. Porous plug retains carbon granules in tube while allowing pressure changes to penetrate to granules. Has greater life expectancy than previous controllers and used in variety of hot corrosive atmospheres.

Parthasarathy, S. P.↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

Improved Portable Ultrasonic Leak Detectors

Improved portable ultrasonic leak detector features three interchangeable ultrasonic-transducer modules, each suited for operation in unique noncontact or contact mode. One module equipped with ultrasound-collecting horn for use in scanning to detect leaks from distance; horn provides directional sensitivity pattern with sensitivity multiplied by factor of about 6 in forward direction. Another module similar, does not include horn; this module used for scanning close to suspected leak, where proximity of leak more than offsets loss of sensitivity occasioned by lack of horn. Third module designed to be pressed against leaking vessel; includes rugged stainless-steel shell. Improved detectors perform significantly better, smaller, more rugged, and greater sensitivity.

Youngquist, Robert C.↗

History, design and performance of the space shuttle hazardous gas detection system

The Hazardous Gas Detection System (HGDS) is designed to detect leaks hich could result in pre-launch or in-flight fires or explosions resulting from the presence of cryogenic rocket propellants. The historical development, design, and performance of the HGDS is discussed. Data for response time, detection limits, accuracy, and drift are presented. Finally, present and future applications are discussed, and some general conclusions are drawn.

Helms, W. R.↗

The development of a solid-state hydrogen sensor for rocket engine leakage detection

Hydrogen propellant leakage poses significant operational problems in the rocket propulsion industry as well as for space exploratory applications. Vigorous efforts have been devoted to minimizing hydrogen leakage in assembly, test, and launch operations related to hydrogen propellant. The objective has been to reduce the operational cost of assembling and maintaining hydrogen delivery systems. Specifically, efforts have been made to develop a hydrogen leak detection system for point-contact measurement. Under the auspices of Lewis Research Center, the Electronics Design Center at Case Western Reserve University, Cleveland, Ohio, has undertaken the development of a point-contact hydrogen gas sensor with potential applications to the hydrogen propellant industry. We envision a sensor array consisting of numbers of discrete hydrogen sensors that can be located in potential leak sites. Silicon-based microfabrication and micromachining techniques are used in the fabrication of these sensor prototypes. Evaluations of the sensor are carried out in-house at Case Western Reserve University as well as at Lewis Research Center and GenCorp Aerojet, Sacramento, California. The hydrogen gas sensor is not only applicable in a hydrogen propulsion system, but also usable in many other civilian and industrial settings. This includes vehicles or facility use, or in the production of hydrogen gas. Dual space and commercial uses of these point-contacted hydrogen sensors are feasible and will directly meet the needs and objectives of NASA as well as various industrial segments.

Liu, Chung-Chiun↗

Miniature Quadrupole Mass Spectrometer Array

JPL is funded by Code U to develop a Miniature QMSA for an EVA flight test. The initial intent was to fly an experiment internal to the astronaut suit during a shuttle EVA. Following discussions with JSC the suit application was abandoned in favor of other more urgent needs. The JSC EVA office was particularly interested in hydrazine detection on the astronaut suit. While discussing and exploring the implementation of such an experiment, managers at JSC suggested combining the interests of two JSC groups. The Life Support and Thermal Systems Branch, Crew and Thermal Systems Division has a need for an ammonia detection instrument, while the EVA office has a need for hydrazine detection. The two groups were pursuing separate single-purpose solutions. Instead, the JPL QMSA offers a single instrument solution via a portable instrument to be used by an astronaut on an EVA. Such an instrument would serve both the ammonia leak detection and the hydrazine contamination needs. The need for the QMSA was defined as urgent and targeted for a January 1999 flight. While the original JPL task (as funded by Code U) was for an experiment flight with JPL delivery in October 1998, this task was for a qualified flight instrument with a planned JPL delivery in August 1998. This schedule was very demanding and dictated a fast-tract implementation.

Karmon, D.↗

Characterization of inexpensive metal oxide sensor performance for trace methane detection

Abstract. Methane, a major contributor to climate change, is emitted by a variety of natural and anthropogenic sources. Commercially available lab-grade instruments for sensing trace methane are expensive, and previous efforts to develop inexpensive, field-deployable trace methane sensors have had mixed results. Industrial and commercial metal oxide (MOx) methane sensors, which are intended for leak detection and safety monitoring, can potentially be repurposed and adapted for low-concentration sensing. As an initial step towards developing a low-cost sensing system, we characterize the performance of five off-the-shelf MOx sensors for 2–10 ppm methane detection in a laboratory setting (Figaro Engineering TGS2600, TGS2602, TGS2611-C00, TGS2611-E00, and Henan Hanwei Electronics MQ4). We identify TGS2611-C00, TGS2611-E00, and MQ4 as promising for trace methane sensing but show that variations in ambient humidity and temperature pose a challenge for the sensors in this application.

54 ENVIRONMENTAL SCIENCES↗