Dynamic intravascular pressures in the microvessels of the frog lung
Dynamic intravascular pressures measured in small vessels of frog lung using micropressure transducer inserted into vessel lumen
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Dynamic intravascular pressures measured in small vessels of frog lung using micropressure transducer inserted into vessel lumen
Counter lung, incorporated in closed-loop rebreathing system, accommodates user's breathing tidal volume so that the loop pressure is relatively constant during breathing cycles.
The pathogenesis of oxygen toxicity in the lung of rats was studied by electron microscopy. The following long-term effects were established: (1) a progressive destruction of the blood-air barrier beginning with the endothelial cell layer; (2) a profuse edema in the interstitial spaces in the pleural space in the alveoli and in the cytoplasm and organelles; (3) a continuing increase in the quantity and complexity of the alveolar exudate; (4) gradual hemolysis of red blood cells; and (5) eventual subsiding of the interstitial edema in surviving rats with a concomitant development of emphysema.
Young Sprague-Dawley rats were exposed to 100% oxygen at 450 mm Hg in constant environment capsules for 90 days. Lung tissue examined by electron microscopy revealed a number of changes, many similar to those observed after exposure to oxygen at 760 mm Hg for shorter periods of time. Alterations in vesicle size and number and in mitochondrial matrix and cristae appear in both the endothelial and epithelial cells. Blebbing and rarefication of cytoplasm occur in both cell layers of the alveolo-capillary wall. Also seen are fluid in the basement membrane, platelets in the capillaries, and alveolar fluid and debris. All of these alterations occur at 1 atm exposure. However, after exposure to 450 mm Hg the changes are not as widespread nor as destructive as they are at the higher pressure.
A device was developed which makes possible the dynamic reconstruction of the heart and lungs within the intact thorax of a living dog or human and which can record approximately 30 multiplanar X-ray images of the thorax practically instantaneously, and at frequent enough intervals of time and with sufficient density and spatial resolution to capture and resolve the most rapid changes in cardiac structural detail throughout each cardiac cycle. It can be installed in a clinical diagnostic setting as well as in a research environment and its construction and application for determination and display in real-time modes of cross sections of the functioning thorax and its contents of living animals and man is technologically feasible.
Changes in the nitrogen concentration seen during the single-breath nitrogen washout reflect changes in relative flow (ventilation) from units with differing ventilation/volume ratios. The multiple-breath washout provides sufficient data on ventilation for units with varying ventilation/volume ratios to be plotted as a function of the volume expired. Flow from the dead space may also be determined. In young normals the emptying patterns are narrow and unimodal throughout the alveolar plateau with little or no flow from the dead space at the end of the breath. Older normals show more flow from the dead space, particularly toward the end of the breath, and some show a high ventilation/volume ratio mode early in the breath. Patients with obstructive lung disease have a high flow from the dead space which is present throughout the breath. A well ventilated mode at the end of the breath is seen in some obstructed subjects. Patients with cystic fibrosis showed a poorly ventilated mode appearing at the end of the breath as well as a very high dead space.
An optical-electromechanical system is used to measure the force-deformation behavior of biaxially loaded rectangular slabs of excised dog lung parenchyma. In the course of the study, the effects of time, the consistency of reference lengths and areas, the presence of hysteresis, the necessity of preconditioning, the repeatability of results, the effects of lateral load, the effect of strain rate, the effect of pH, the influence of temperature, and the variations among specimens are considered. A new finding is that there is a change in elastic behavior when the tissue undergoes a compressive strain. When the tissue is in tension, increasing the lateral load decreases the compliance, whereas the opposite is true when compressive strain is present.
Weanling male rats were fed semipurified diets supplemented with 0, 60, or 600 IU/kg vitamin E or 0, 100, or 1000 ppb selenium. One group was injected daily with vitamin E at a rate equivalent to consumption of 60 IU/kg. Animals from all groups were sacrificed after exposure to normobaric oxygen or air for 48 h. Lung tissue was analyzed for the combined activity of prostaglandin dehydrogenase and reductase. Using the decline in enzyme activity as an indicator of susceptibility to oxygen poisoning, protection against hyperoxia was directly related to the level of vitamin E supplementation. Selenium supplemented at 100 ppb provided significant protection when compared to 0 ppb or 1000 ppb. The latter dose may have been marginally toxic. Thus dietary supplementation of vitamin E and selenium may influence the relative susceptibility of an animal to pulmonary oxygen poisoning.
Lysophosphatidylcholine (lyso-Pc) is a lysophospholipid normally found in low concentrations in the lung. At high concentrations lyso-Pc, instilled into the airways, causes pulmonary edema. The hypothesis was tested that the edema caused by lyso-Pc was due to an increase in pulmonary microvascular membrane permeability. In 11 anesthetized dogs, the left lower lobes (LLL) were continuously weighed while lyso-Pc (20 mM) was instilled into the LLL airways. After 30 min, the microvascular membrane fluid filtration coefficient (Kf) was determined from the relationship between the rate of LLL weight gain and the pulmonary microvascular pressure. Kf was not significantly different between the lyso-Pc-treated lobes vs control lobes. The data do not support the hypothesis that lyso-Pc, instilled into the airways, causes an increase in pulmonary microvascular permeability.
Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.
The analysis of the gas in a single expirate has long been used to estimate the degree of ventilation-perfusion (Va/Q) inequality in the lung. To further validate this estimate, we examined three measures of Va/Q inhomogeneity calculated from a single full exhalation in nine anesthetized mongrel dogs under control conditions and after exposure to aerosolized methacholine. These measurements were then compared with arterial blood gases and with measurements of Va/Q inhomogeneity obtained using the multiple inert gas elimination technique. The slope of the instantaneous respiratory exchange ratio (R slope) vs. expired volume was poorly correlated with independent measures, probably because of the curvilinear nature of the relationship due to continuing gas exchange. When R was converted to the intrabreath Va/Q (iV/Q), the best index was the slope of iV/Q vs. volume over phase III (iV/Q slope). This was strongly correlated with independent measures, especially those relating to inhomogeneity of perfusion. The correlations for iV/Q slope and R slope considerably improved when only the first half of phase III was considered. We conclude that a useful noninvasive measurement of Va/Q inhomogeneity can be derived from the intrabreath respiratory exchange ratio.
The lung rudiment, isolated from mid-gestation (11 day) mouse embryos, can undergo morphogenesis in organ culture. Observation of living rudiments, in culture, reveals both growth and ongoing bronchiolar branching activity. To detect proteoglycan (PG) biosynthesis, and deposition in the extracellular matrix, rudiments were metabolically labeled with radioactive sulfate, then fixed, embedded, sectioned and processed for autoradiography. The sulfated glycosaminoglycan (GAG) types, composing the carbohydrate component of the proteoglycans, were evaluated by selective GAG degradative approaches that showed chondroitin sulfate PG principally associated with the interstitial matrix, and heparan sulfate PG principally associated with the basement membrane. Experiments using the proteoglycan biosynthesis disrupter, beta-xyloside, suggest that when chondroitin sulfate PG deposition into the ECM is perturbed, branching morphogenesis is compromised.
The large diffusion coefficients of gases result in significant spin motion during the application of gradient pulses that typically last a few milliseconds in most NMR experiments. In restricted environments, such as the lung, this rapid gas diffusion can lead to violations of the narrow pulse approximation, a basic assumption of the standard Stejskal-Tanner NMR method of diffusion measurement. We therefore investigated the effect of a common, biologically inert buffer gas, sulfur hexafluoride (SF(6)), on (129)Xe NMR and diffusion. We found that the contribution of SF(6) to (129)Xe T(1) relaxation in a 1:1 xenon/oxygen mixture is negligible up to 2 bar of SF(6) at standard temperature. We also measured the contribution of SF(6) gas to (129)Xe T(2) relaxation, and found it to scale inversely with pressure, with this contribution approximately equal to 1 s for 1 bar SF(6) pressure and standard temperature. Finally, we found the coefficient of (129)Xe diffusion through SF(6) to be approximately 4.6 x 10(-6) m(2)s(-1) for 1 bar pressure of SF(6) and standard temperature, which is only 1.2 times smaller than the (129)Xe self diffusion coefficient for 1 bar (129)Xe pressure and standard temperature. From these measurements we conclude that SF(6) will not sufficiently reduce (129)Xe diffusion to allow accurate surface-area/volume ratio measurements in human alveoli using time-dependent gas diffusion NMR.
The distribution of gaseous pulmonary emboli is presumed to be determined by their buoyancy. We hypothesized that regional pulmonary blood flow may also influence their distribution. Therefore, pulmonary blood flow was measured in supine, anesthetized dogs with use of 15-microm fluorescent microspheres at baseline and during N(2) embolism. The animals were killed, and the lungs were excised, air-dried, and diced into approximately 2-cm(3) pieces with weights and spatial coordinates recorded. Embolism was defined as a >10% flow decrease relative to baseline. Vertically, the incidence of embolism increased substantially by 6 +/- 1% per additional centimeter in height compared with baseline (P = 0.0003). Embolism also increased radially by 3 +/- 1%/cm from the hilum (P = 0.002). There was a weaker but statistically significant increase in embolism to pieces with greater baseline flow, 9 +/- 2% for every 1. 0 increase in relative baseline flow (P = 0.008). We conclude that the distribution of gaseous emboli is influenced by buoyancy and flow dynamics within the pulmonary vasculature.
We performed bolus inhalations of 1-micrometer particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and in approximately 1.6 G. Boluses of approximately 70 ml were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 200 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The deposition, dispersion, and position of the bolus in the expired gas were calculated from these data. For Vp >/=400 ml, both deposition and dispersion increased with Vp and were strongly gravity dependent, with the greatest deposition and dispersion occurring for the largest G level. At Vp = 800 ml, deposition and dispersion increased from 33.9% and 319 ml in microG to 56.9% and 573 ml at approximately 1.6 G, respectively (P < 0.05). At each G level, the bolus was expired at a smaller volume than Vp, and this volume became smaller with increasing Vp. Although dispersion was lower in microG than in 1 G and approximately 1.6 G, it still increased steadily with increasing Vp, showing that nongravitational ventilatory inhomogeneity is partly responsible for dispersion in the human lung.
We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.
In order to develop appropriate countermeasures for NASA's return mission to the moon, the potential toxicity of lunar dust needs to be examined. Due to its abrasiveness, reactivity, composition and small size, lunar dust may pose a serious health risk to astronauts who inhale it. This project focuses on the toxicity of lunar dust simulant (JSC-1A-vf) using WI-38 human embryonic lung cells. Past results show that the simulant has toxic effects on small animals using intratracheal instillation. Earlier studies in this lab suggest that the dust remaining in media after low speed centrifugation is toxic. In order to better assess its toxicity, the simulant has been diluted in media, filtered with a 5 micron filter before combining it with media. This filtered dust is compared with dust centrifuged in media. Whole dust toxicity is also tested. Toxicity is estimated using a 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) toxicity test which measures the activity of reducing enzymes in the mitochondria of viable cells. Preliminary results suggest that simulant which is diluted in media at different concentrations is slightly toxic. Interestingly, the cells appear to sweep up and collect the simulant. Whether this contributes to its toxicity is unclear. This project provides possible toxicity testing protocols for lunar dust and contributes to the knowledge of nanosize particle toxicity.
NASA is contemplating to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, TiO2, or quartz, suspended in normal saline were given to groups of 5 C57 male mice by intrapharyngeal aspiration at 0. 1, 0.3, or 1.0 mg/mouse. Because lunar dust aggregates rapidly in aqueous media, some tests were conducted with dusts suspended in Survanta/saline (1:1). The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the presence of toxicity biomarkers in bronchioalveolar lavage fluids. The overall results showed that the two lunar dust samples were similar in toxicity, they were more toxic than T102 , but less toxic than quartz. This preliminary study is a part of the large study to obtain data for setting exposure limits for astronauts living on the Moon