Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LONGITUDINAL BEAM DYNAMICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Space Charge Waves in Mismatched Beams

Mismatch oscillations resulting from the propagation of space charge waves in intense beams may lead to halo generation, beam loss, and modification of longitudinal beam properties. These oscillations have amplitudes and frequencies different from that of the main beam and are particularly important in machines such as the University of Maryland Electron Ring (UMER), in which the beam dynamics scales to parameters associated with heavy ion fusion drivers. To study these effects, we use the particle in cell code LSP [1] to simulate space charge wave dynamics in an intense electron beam propagating in a smooth focusing channel with 2-D cylindrical symmetry. We examine the evolution of linear and nonlinear density perturbations for both matched and mismatched beams. Comparisons between LSP simulations and numerical models are presented.

43 PARTICLE ACCELERATORS↗

X-Band Photoinjector Beam Dynamics

SLAC is studying the feasibility of using an X-band RF photocathode gun to produce low emittance bunches for applications such as a mono-energetic MeV {gamma} ray source (in collaboration with LLNL) and a photoinjector for a compact FEL. Beam dynamics studies are being done for a configuration consisting of a 5.5-cell X-band gun followed by several 53-cell high-gradient X-band accelerator structures. A fully 3D program, ImpactT, is used to track particles taking into account space charge forces, short-range longitudinal and transverse wakefields, and the 3D rf fields in the structures, including the quadrupole component of the couplers. The effect of misalignments of the various elements, including the drive-laser, gun, solenoid and accelerator structures, are evaluated. This paper presents these results and estimates of the expected bunch emittance vs cathode gradient, and the effects of mixing between the fundamental and off-frequency longitudinal modes. An X-band gun at SLAC has been shown to operate reliably with a 200 MV/m acceleration gradient at the cathode, which is nearly twice the 115 MV/m acceleration gradient in the LCLS gun. The higher gradient should roughly balance the space charge related transverse emittance growth for the same bunch charge but provide a 3-4 times shorter bunch length. The shorter length would make the subsequent bunch compression easier and allow for a more effective use of emittance exchange. Such a gun can also be used with an X-band linac to produce a compact FEL or g ray source that would require rf sources of only one frequency for beam generation and acceleration. The feasibility of using an X-band rf photocathode gun and accelerator structures to generate high quality electron beams for compact FELs and g ray sources is being studied at SLAC. Results from the X-band photoinjector beam dynamics studies are reported in this paper.

43 PARTICLE ACCELERATORS↗

High-resolution fully vectorial scanning Kerr magnetometer

We report on the development of a high-resolution scanning magnetometer, which fully exploits the vectorial nature of the magneto-optical Kerr effect. The three-dimensional nature of magnetization is at the basis of many micromagnetic phenomena and from these data, we can fully characterize magnetization processes of nanostructures in static and dynamic regimes. Our scanning Kerr magnetometer uses a high numerical aperture microscope objective where the incident light beam can be deterministically deviated from the objective symmetry axis, therefore, both in-plane (via the longitudinal Kerr effect) and out-of-plane (via the polar Kerr effect) components of the magnetization vector may be detected. These components are then separated by exploiting the symmetries of the polar and longitudinal Kerr effects. From four consecutive measurements, we are able to directly obtain the three orthogonal components of the magnetization vector with a resolution of 600 nm. Performance of the apparatus is demonstrated by a measurement of 3D magnetization vector maps showing out-of-plane domains and in-plane domain walls in an yttrium-iron-garnet film and on a study of magnetization reversal in a 4-μm-wide magnetic disk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the electrostatic design of the Jefferson Lab 300 kV DC photogun

The 300 kV DC high voltage photogun at Jefferson Lab was redesigned to deliver electron beams with a much higher bunch charge and improved beam properties. The original design provided only a modest longitudinal electric field ( E z ) at the photocathode, which limited the achievable extracted bunch charge. To reach the bunch charge goal of approximately few nC with 75 ps full-width at half-maximum Gaussian laser pulse width, the existing DC high voltage photogun electrodes and anode–cathode gap were modified to increase E z at the photocathode. In addition, the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the non-symmetric nature of the inverted insulator photogun design. We present the electrostatic design of the original photogun and the modified photogun and beam dynamics simulations that predict vastly improved performance. We also quantify the impact of the photocathode recess on beam quality, where recess describes the actual location of the photocathode inside the photogun cathode electrode relative to the intended location. A photocathode unintentionally recessed/misplaced by sub-millimeter distance can significantly impact the downstream beam size.

47 OTHER INSTRUMENTATION↗

Vibration characteristics of 1/8-scale dynamic models of the space-shuttle solid-rocket boosters

Vibration tests and analyses of six 1/8 scale models of the space shuttle solid rocket boosters are reported. Natural vibration frequencies and mode shapes were obtained for these aluminum shell models having internal solid fuel configurations corresponding to launch, midburn (maximum dynamic pressure), and near endburn (burnout) flight conditions. Test results for longitudinal, torsional, bending, and shell vibration frequencies are compared with analytical predictions derived from thin shell theory and from finite element plate and beam theory. The lowest analytical longitudinal, torsional, bending, and shell vibration frequencies were within + or - 10 percent of experimental values. The effects of damping and asymmetric end skirts on natural vibration frequency were also considered. The analytical frequencies of an idealized full scale space shuttle solid rocket boosted structure are computed with and without internal pressure and are compared with the 1/8 scale model results.

Leadbetter, S. A.↗

Longitudinal scaling of observables in heavy-ion collision models

Longitudinal scaling of pseudorapidity distribution of charged particles (dN{sub ch}/d{eta}) is observed when presented as a function of pseudorapidity ({eta}) shifted by the beam rapidity ({eta}-y{sub beam}) for a wide range of collision systems (e{sup +}+e{sup -}, p+p, d+A, and A+A) and beam energies. Such a scaling is also observed for the elliptic flow (v{sub 2}) of charged hadrons in A+A collisions. This is a striking observation, as v{sub 2} is expected to be sensitive to the initial conditions, the expansion dynamics, and the degrees of freedom of the system, all of which potentially varies with collision system and colliding energies. We present a study of the longitudinal scalings of dN{sub ch}/d{eta}, average transverse momentum (<p{sub T}>), and v{sub 2} using transport models UrQMD and AMPT for Au + Au collisions at center of mass energies ({radical}(s{sub NN})) of 19.6, 62.4, and 200 GeV and Pb + Pb collisions at 2760 GeV. Only the AMPT models which includes partonic effects and quark coalescence as a mechanism of hadronization shows longitudinal scaling for dN{sub ch}/d{eta}, <p{sub T}>, and v{sub 2}. Whereas the UrQMD and AMPT default versions show longitudinal scaling only for dN{sub ch}/d{eta} and <p{sub T}>. We also discuss the possibility of longitudinal scaling of v{sub 2} within two extreme scenarios of models with hydrodynamic and collisionless limits. We find the longitudinal scaling of bulk observables to be an important test for the underlying physics mechanism in models of particle production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Longitudinal Wakefield Study in SLAC Rotatable Collimator Design for the LHC Phase II Upgrade

SLAC proposed a rotatable collimator design for the LHC Phase II collimation upgrade. There are 20 facet faces on each cylindrical jaw surface and two jaws are rotatable in order to introduce a clean surface in case of a beam hitting a jaw during operation. When the beam crosses the collimator, it will excite broad-band and narrow-band modes. The longitudinal modes can contribute to beam energy loss and power dissipation on the vacuum chamber wall. In this paper, the parallel finite element eigensolver Omega3P is used to search for all the longitudinal trapped modes in the SLAC collimator design. The power dissipation generated by the beam in collimators with different vacuum chamber and RF contact designs is discussed. It is found that a wider RF foil connecting the jaw and the vacuum flange can reduce efficiently the beam heating caused by the longitudinal modes.

43 PARTICLE ACCELERATORS↗

Design and Contruction of a Longitudinally Polarized Solid Nuclear Target for CLAS12

A new polarized nuclear target has been developed, constructed, and deployed at Jefferson Laboratory in Newport News, VA for use with the upgraded 12 GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. This ?APOLLO? (Ammonia PO-Larized LOngitudinally) target is a longitudinally polarized, solid ammonia, nuclear target which employs DNP (Dynamic Nuclear Polarization) to induce a net polarization in samples of protons (NH3) and deuterons (ND3) cooled to 1 K via helium evaporation, held in a 5 T polarizing field supplied by the CLAS12 spectrometer, and irradiated with 140 GHz microwave radiation. It was utilized in the RGC (Run Group C) experiment suite through a collaboration of the JLab Target Group, Old Dominion University, Christopher Newport University, the University of Virginia, and the CLAS Collaboration. RGC comprised six experiments which measured multiple spin-dependent observables across a wide kinematic phase space for use in nucleon spin studies. The dimensional constraints necessary for the incorporation of APOLLO into CLAS12, as well as the considerations necessary to utilize the CLAS12 solenoid, introduced unique challenges to the target design. This document presents the innovative solutions developed for these challenges including a novel material transport system, superconducting magnetic correction coils, and an all new bespoke NMR (Nuclear Magnetic Resonance) system. In addition to a detailed description of the complete target system and an initial report of the RGC experimental run, it will also present a study of Quark-Hadron Duality in the g1 spin structure function based on Hall B EG1b data and pQCD fits from the JAM (Jefferson Lab Angular Momentum) Collaboration.

Lagerquist, Victoria Lagerquist↗

Nonlinear dynamics experiments

The goal of nonlinear dynamics experiments is to improve the understanding of single particle effects that increase the particle amplitude and lead to loss. Particle motion in storage rings is nearly conservative and for transverse dynamics the Hamiltonian in action angle variables (I{sub x},I{sub y},{phi}{sub x},{phi}{sub y}) near an isolated resonance k{nu}{sub x} + l{nu}{sub y} {approx} p is H = I{sub x}{nu}{sub x0} + I{sub y}{nu}{sub y0} + g(I{sub x}, I{sub y}) + h(I{sub x}, I{sub y})cos(k{phi}{sub x} + l{phi}{sub y} - p{theta}), (1) where k, l, p are integers, {theta} = 2{pi}s/L is the azimuth, and s and L are the path length and circumference respectively. The amplitude dependent tunes are given by {nu}{sub x,y}(I{sub x},I{sub y}) = {nu}{sub x0,y0} + {partial_derivative}g(I{sub x},I{sub y})/{partial_derivative}I{sub x,y} (2) and h(I{sub x},I{sub y}) is the resonance driving term (RDT). If the motion is governed by multiple resonances, h(I{sub x},I{sub y}) has to be replace by a series of terms. The particle motion is completely determined by the terms g and h, which can be calculated from higher order multipoles (Sec. ??), or obtained from simulations. Deviations from pure Hamiltonian motion occur due to synchrotron radiation damping (Sec. ??) in lepton or very high energy hadron rings, parameter variations, and diffusion processes such as residual gas and intrabeam scattering. The time scale of the non-Hamiltonian process determines the applicability of the Hamiltonian analysis. Transverse nonlinearities are introduced through sextupoles or higher order multipoles and magnetic field errors in dipoles and quadrupoles. Sextupoles can already drive all resonances. The beam-beam interaction and space charge also introduce nonlinear fields. Intentionally introduced nonlinearities are used to extract beam on a resonance or through capture in stable islands. Localization and minimization of nonlinearities in a ring is a general strategy to decrease emittance growth and increase the beam lifetime. The minimization of nonlinear effects can be done locally or globally. Except for resonant extraction, amplitude increase and particle loss is the result of chaotic particle motion. Large chaotic regions allow particles to increase their amplitudes, and ensures their ultimate loss. However, chaotic particles can, on average, still survive the time period of interest, i.e. the storage time. Nonlinear dynamics experiments aim to determine either the detuning and driving terms g and h directly, or their effect on other quantities. Nonlinear phenomena observed in experiments include phase space deformations and resonant islands in Poincare surfaces of section, nonlinear phase advances, amplitude detuning g, decoherence (Sec. ??), resonance driving terms h, smear, halo formation, echoes (Sec. ??), the tune response matrix, dynamic aperture (Sec. ??), emittance growth, and particle loss. Nonlinear experiments can also be done in the longitudinal plane.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of standing wave RF cavities for tracking through multi-pass energy recovery linac

Short bunches, high current and multiple linac pass are all characteristics of Energy Recovery Linacs (ERLs), which may result in collective effects. They in turn, may affect the beam, degrading its quality, or even yield to instabilities causing a beam loss. To study and mitigate these effects one needs a numerical simulation code, that can take into account both the collective effects, as well as, particular ERL features, such as a multi-turn design that does not reach a steady state or the multiple passages of the beam through Radio-Frequency (RF) cavities at different energies. CODAL [1], a code developed by SOLEIL in collaboration with IJCLab, enables such studies. It is a 6 dimensional (6D) tracking code applying 'kicks' based on the integration of the local Hamiltonian for each element of the lattice. It is also capable of simulating space charge, wakefields and coherent synchrotron radiation. However, to correctly take into account the ERL dynamics, an upgrade had to be made to include the effect of a standing wave RF cavity in 6D. In this paper, we will concentrate on the implementation and benchmarking (with DESY’s tracking code ASTRA [2]) of both the longitudinal and the transverse models (by J.B. Rosenzweig and L. Serafini [3]), which we use to carry out tracking of fully analytical 6D RF cavity.

Bogacz, A.↗

A hybrid approach for generating ultra-short bunches for advanced accelerator applications

Generation of electron beams with high phase-space density, short bunch length and high peak current is an essential requirement for future linear colliders and bright electron beam sources. Unfortunately, such bunches cannot be produced directly from the source since forces from the mutual repulsion of electrons would destroy the brilliance of the beam within a short distance. Here, we detail a beam dynamics study of an innovative two-stage compression scheme that can generate ultra-short bunches without degrading the beam quality. In the first stage, the beam is compressed with an advanced velocity bunching technique in which the longitudinal phase space is rotated so that electrons on the bunch tail become faster than electrons in the bunch head. In the second stage, the beam is further compressed with a conventional magnetic chicane. With the aid of numerical simulations we show that our two-staged scheme is capable to increase the current of a 50 pC bunch to a notable factor of 100 while the emittance growth can be suppressed to 1% with appropriate tailoring of the initial beam distribution.

43 PARTICLE ACCELERATORS↗

Beam dynamics of the Neutralized Drift Compression Experiment-II, a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at approx1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of approx50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at the Lawrence Berkeley National Laboratory. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (one-, two-, and three-dimensional) employed and the space-charge-dominated beam dynamics being realized.

43 PARTICLE ACCELERATORS↗

Beam dynamics of the Neutralized Drift Compression Experiment-II (NDCX-II),a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at {approx}1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of {approx}50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at LBNL. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (1-D, 2-D, and 3-D) employed and the space-charge-dominated beam dynamics being realized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam dynamics of the Neutralized Drift Compression Experiment-II (NDCX-II), a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at {approx}1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of {approx}50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at LBNL. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (1-D, 2-D, and 3-D) employed and the space-charge-dominated beam dynamics being realized.

43 PARTICLE ACCELERATORS↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

Modeling of reference operating scenario of GOL-NB multiple-mirror trap

Currently, the GOL-NB multiple-mirror trap is being developed at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. The main scientific goal pursued by building GOL-NB is direct demonstration of suppression of longitudinal losses of particles and energy from the trap by using sections with a multiple-mirror magnetic field, which can be attached to the central gas-dynamic trap. Plasma heating in GOL-NB will be accomplished by neutral beam injection with a power of up to 1.5MW. The paper presents the first results of modeling the dynamics of the plasma parameters and fast ions under the reference operating scenario of the trap in which traditional short magnetic mirrors, rather than multiple-mirror sections, are attached to the central trap. In such a configuration, the plasma lifetime in the trap is expected to be minimal. The modeling was performed by using the DOL kinetic code. As a result, the initial conditions of the experiments are refined and the requirements to the system of maintaining the particle balance in the trap are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗