Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIQUID NITROGEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

Meissner-Effect Stepping Motor

Proposed stepping motor derives torque from diamagnetic repulsion produced by Meissner effect - exclusion of magnetic field from interior of superconductor. Design of motor takes advantage of silver-doped YB2Cu3O and other compounds superconductive at temperatures as high as that of liquid nitrogen. Skin of rotor cooled below its superconducting-transition temperature by liquid nitrogen. O-rings prevent leaks of liquid nitrogen from rotor. Weight, cost, and maintenance reduced.

Robertson, Glen A.↗

Thermodynamic Properties of Nitrogen Including Liquid and Vapor Phases from 63K to 2000K with Pressures to 10,000 Bar

Tables of thermodynamic properties of nitrogen are presented for the liquid and vapor phases for temperatures from the freezing line to 2000K and pressures to 10,000 bar. The tables include values of density, internal energy, enthalpy, entropy, isochoric heat capacity, isobaric heat capacity velocity of sound, the isotherm derivative, and the isochor derivative. The thermodynamic property tables are based on an equation of state, P=P (p,T), which accurately represents liquid and gaseous nitrogen for the range of pressures and temperatures covered by the tables. Comparisons of property values calculated from the equation of state with measured values for P-p-T, heat capacity, enthalpy, latent heat, and velocity of sound are included to illustrate the agreement between the experimental data and the tables of properties presented here. The coefficients of the equation of state were determined by a weighted least squares fit to selected P-p-T data and, simultaneously, to isochoric heat capacity data determined by corresponding states analysis from oxygen data, and to data which define the phase equilibrium criteria for the saturated liquid and the saturated vapor. The vapor pressure equation, melting curve equation, and an equation to represent the ideal gas heat capacity are also presented. Estimates of the accuracy of the equation of state, the vapor pressure equation, and the ideal gas heat capacity equation are given. The equation of state, derivatives of the equation, and the integral functions for calculating derived thermodynamic properties are included.

Thermodynamic properties↗

Joule-Thomson Cryogenic Nitrogen Orifice Flows

The Joule-Thomson Effect involves the expansion of a fluid through a throttling device, often a simple orifice, resulting in a change in the fluid's temperature. It has been leveraged in the design and analysis of Thermodynamic Vent Systems and integrated into injector designs for cryogenic no-vent fill tank-to-tank transfer testing. There is a scarcity of comprehensive data available to model the phenomenon effectively using tools such as GFSSP for cryogenic nitrogen flows. This experiment aims to model the Joule-Thomson effect of liquid nitrogen through seven traditionally manufactured, sharp-edged orifices manufactured by O’Keefe and three additively manufactured (AM) orifices manufactured by Cumberland Additive. The traditional orifice sizes were 0.016, 0.02, 0.024, 0.032, 0.037, and 0.04 inch in diameter. The three additive orifices had diameters with target/nominal sizes equal to the 0.016, 0.024, and 0.04 inch O’Keefe orifices. However, the actual diameters of the AM orifices were found to be 0.014, 0.024, and 0.035 inches due to additive manufacturing restrictions. Water was flowed through the orifices to verify that their flow coefficients matched published values and to establish flow coefficients for the AM orifices. Liquid nitrogen was flowed through the orifices in a separate test apparatus. The liquid nitrogen started as a subcooled liquid upstream of the orifice and transitioned into a two-phase gas-liquid mixture after passing through each orifice. The upstream pressure was set to 29 psia, 34 psia, 39 psia, and/or 42 psia or 44 psia. The pressure, temperature, and flow rate were measured upstream and downstream of the orifice for three trials at each set point. The average volumetric flow rate and Joule-Thomson Coefficients were calculated from this data. The AM orifices and traditionally manufactured orifices displayed similar results. This data will refine the dataset GFSSP uses to model the J-T Effect more accurately.

Joule-Thomson↗

Validation of Heat Transfer Correlations in Line Chill-Down Tests of Cryogenic Fluid in SINDA/FLUINT

Line Chill-down heat transfer was modelled using SINDA/FLUINT. Multiple chill-down tests were modelled using the heat transfer correlations that are available in SINDA/FLUINT, as well as incorporating heat transfer empiricisms developed by the University of Florida1 based on a series of liquid nitrogen chill-down tests. The chill-down tests that were modelled were the liquid nitrogen tests conducted by the University of Florida1 as well as liquid hydrogen tests conducted by NASA Glenn Research Center2. The liquid nitrogen tests included horizontal flow, upward flow, and downward flow with the liquid Reynolds Numbers ranging 850 - 231,000. The liquid hydrogen test was vertical upward flow at a Reynolds Number range of 18,400 - 433,000. Both the University of Florida's heat transfer correlations and SINDA/FLUINT's internal correlations faired similarly to wall temperature test data. They were acceptable although improvements could be made to the University of Florida correlations as well and SINDA/FLUINT's internal correlations.

cryogenic modeling↗

Thermal-fluid analysis of the fill and drain operations of a cryrogenic fuel tank

The Generic Research Cryogenic Tank was designed to establish techniques for testing and analyzing the behavior of reusable fuel tank structures subjected to cryogenic fuels and aerodynamic heating. The Generic Research Cryogenic Tank tests will consist of filling a pressure vessel to a prescribed fill level, waiting for steady-state conditions, then draining the liquid while heating the external surface to simulate the thermal environment associated with hypersonic flight. Initial tests of the Generic Research Cryogenic Tank will use liquid nitrogen with future tests requiring liquid hydrogen. Two-dimensional finite-difference thermal-fluid models were developed for analyzing the behavior of the Generic Research Cryogenic Tank during fill and drain operations. The development and results of the two-dimensional fill and drain models, using liquid nitrogen, are provided, along with results and discussion on extrapolating the model results to the operation of the full-size Generic Research Cryogenic Tank. These numerical models provided a means to predict the behavior of the Generic Research Cryogenic Tank during testing and to define the requirements for the Generic Research Cryogenic Tank support systems such as vent, drain, pressurization, and instrumentation systems. In addition, the fill model provided insight into the unexpected role of circumferential conduction in cooling the Generic Research Cryogenic Tank pressure vessel during fill operations.

Stephens, Craig A.↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements. The final paper will present sensitivity studies and additional comparisons with test data.

Computational Fluid Dynamics, Cryogenic, Spray Chi↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Improved Models for Simulation of Cryogenic Spray Cooling for Propellant Tank Chilldown

This paper presents advances in spray boiling models for cryogenic fluids that exhibit strong variation in thermodynamic properties; it accounts for the interaction of the spray droplets with walls and the complex heat transfer and boiling processes that play a vital role in chilling solid surfaces. The model has been developed by corroborating and validating it with test data in liquid nitrogen obtained at the University of Connecticut. The test data includes detailed visualization and plate temperature measurements for liquid nitrogen sprays impinging on a warm test plate and subsequent transient chilldown of the plate. Simulations of transient plate chilldown in liquid nitrogen were carried out and temperature histories at various locations on the plate were compared with test measurements to demonstrate the validity of the spray boiling models that have been developed for cryogens.

Boiling↗

Magnetic suspension using high temperature superconducting cores

The development of YBCO high temperature superconductors, in wire and tape forms, is rapidly approaching the point where the bulk transport current density j vs magnetic field H characteristics with liquid nitrogen cooling will enable its use in model cores. On the other hand, BSCCO high temperature superconductor in wire form has poor j-H characteristics at 77 K today, although with liquid helium or hydrogen cooling, it appears to be superior to NbTi superconductor. Since liquid nitrogen cooling is approx. 100 times cheaper than liquid helium cooling, the use of YBCO is very attractive for use in magnetic suspension. The design is discussed of a model core to accommodate lift and drag loads up to 6000 and 3000 N respectively. A comparison is made between the design performance of a liquid helium cooled NbTi (or BSCCO) superconducting core and a liquid nitrogen cooled YBCO superconducting core.

Scurlock, R. G.↗

Effect of gas mass flux on cryogenic liquid jet breakup

A scattered-light scanning instrument developed at NASA Lewis Research Center was used to measure the characteristic drop size of clouds of liquid nitrogen droplets. The instrument was calibrated with suspensions of monosized polystyrene spheres. In this investigation of the mechanism of liquid nitrogen jet disintegration in a high-velocity gas flow, the Sauter mean diameter, D32, was found to vary inversely with the nitrogen gas mass flux raised to the power 1.33. Values of D32 varied from 5 to 25 microns and the mass flux exponent of 1.33 agrees well with theory for liquid jet breakup in high-velocity gas flows. The loss of very small droplets due to the high vaporization rate of liquid nitrogen was avoided by sampling the spray very close to the atomizer, i.e., 1.3 cm downstream of the nozzle orifice. The presence of high velocity and thermal gradients in the gas phase also made sampling of the particles difficult. As a result, it was necessary to correct the measurements for background noise produced by both highly turbulent gas flows and thermally induced density gradients in the gas phase.

Ingebo, R. D.↗

Photoemf in cadmium sulfide

Theoretical and experimental investigations on CdS single crystals and CuxS:CdS photovoltaic cells prepared from CdS single crystals by a chemical-dip procedure are described. The studies are aimed at clarifying cell mechanisms which affect key cell properties (efficiency, reliability, and lifetime) by examining the properties of intrinsic and extrinsic defects in the junction and surface regions and their effects on carrier transport through these regions. The experimental research described includes studies of thermal, infrared, and field quenching of acceptor-doped CdS crystals; investigation of optical and electrical properties of CuxS:CdS photovoltaic cells (current-voltage characteristics, spectral distribution of photocurrent and photovoltage) and the dependence of these properties on temperature and light intensity; measurement of changes, as a result of heat treatment in ultrahigh vacuum, in the spectral distribution of photoconductivity at room temperature and liquid nitrogen temperature, the luminescence spectrum at liquid nitrogen temperature, and the thermally stimulated current curves of CdS crystals; determination of the effect of irradiation with 150 keV (maximum) X-rays on the spectral distribution of photoconductivity and thermally-stimulated current of CdS crystals; and studies of the effect of growth conditions on the photoconductive properties of CdS crystals.

Boeer, K. W.↗

Measuring Inhomogeneities In Thermocouple Wires

Spools rotated to pull thermocouple wires through liquid nitrogen, while output voltage of thermocouple recorded on strip chart. Wires exposed to severe temperature gradients, amounting to overall change of 200 degrees C, where they enter and leave liquid nitrogen. If wires homogeneous, net output voltage zero. If inhomogeneity passes through liquid-nitrogen/air interface, resulting deviation of output voltage from zero seen immediately on strip chart. If inhomogeneity greater than allowable, reels stopped temporarily so inhomogeneity tagged before wound onto takeup reel.

Burkett, Cecil G., Jr.↗

Static and dynamic fatigue behavior of glass filament-wound pressure vessels at ambient and cryogenic temperatures.

Investigation of the pressure load carrying capacity and fatigue strength of filament-wound glass-reinforced plastic pressure vessels subjected to static and cyclic loading at ambient and cryogenic (liquid nitrogen) temperature environments. The results indicate that the static fatigue problem is not critical at cryogenic temperatures. Under static loading at liquid nitrogen temperature, a reinforced plastic cylinder sustained pressurization for 88 days without failure at about 90% of the single cycle burst strength. At ambient temperature, the static life at 90% of the burst strength was about 7 min. Under cyclic loading in liquid nitrogen, no failure resulted after 1509 cycles at 55% of the single cycle burst strength. Under the same cyclic loading at ambient temperature, the test results would predict failure in the reinforced plastic. The results of similar tests upon adhesively bonded polyimide aluminum-foil lined cylinders are also reviewed.-

Hanson, M. P.↗

Liquefaction of Cryogenic Fluids for Production and Storage of Commodities on Extra-Terrestrial Surfaces

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) activity has been investigating concepts for the liquefaction of cryogenic fluids produced on the surface of the Moon and Mars. CryoFILL consists of four activities: liquid nitrogen liquefaction testing that was completed in 2019, liquid oxygen liquefaction testing planned to begin in early 2022, fiber-optic sensor temperature measurement system development, and lightweight vacuum jacketed systems designed for the atmosphere of Mars. Additional activities include the development and validation of numerical modeling systems at three stages: thermodynamic models of the liquefaction process for basic energy/mass estimates, nodal models to predict liquefaction tank system level performance, and computational fluid dynamics to assess fluid phenomena occurring within the tank, specifically condensation and stratification within the ullage. These developments form a combined liquefaction and storage solution to support Lunar and Martian exploration. Key testing results from liquid nitrogen testing as well as plans for liquid oxygen testing will be discussed including key sensitivities from analytical evaluation of completed test results. Progress on the development and improvements on fiber optic sensor testing and developments will also be provided. Finally, work on the progress of the lightweight vacuum jacketed systems being co-developed by NASA and industry will be summarized.

Liquefaction↗

Charged Probes, Bourdon Tubes Maintain Cryogenic Liquid Level

The problem: To design a system that automatically maintains the fluid level in a liquid nitrogen cold trap. It is frequently necessary to operate a vacuum system using one or more cold traps for a prolonged period with the cold trap liquid level maintained between set limits. Electronic devices have been subject to failure due to the effect on components of cryogenic temperatures. The solution: An automatic liquid nitrogen dispensing system that uses gas filled probes, driving Bourdon tube gauges equipped with microswitches that, through a relay, control a solenoid valve in the liquid nitrogen storage line.

Krejsa, Mylo J.↗

Cryocooled cold trap system for the SuperCDMS dilution refrigerator

Operating 6,800 feet underground at the SNOLAB facility in Sudbury, Ontario, Canada, the dilution refrigerator-cooled SuperCDMS SNOLAB (Super Cryogenic Dark Matter Search at the Sudbury Neutrino Observatory Laboratory) experiment has been designed for maximum cryogenic up-time and remote operations. A key element in achieving these goals is a pair cold traps in the helium circulation stream of the dilution refrigerator; the first operating near liquid nitrogen temperatures and the second operating near liquid helium temperatures. Previous experience with the CDMS experiment, located underground at the Soudan Under-ground Laboratory, has given significant operational experience with dilution refrigerator cold traps and has solidified the demand of a system of dual cold traps. Unlike the CDMS-era system, the new SuperCDMS system will feature a cryocooler powered liquid nitrogen re-liquefying system (as opposed to regular under-ground re-filling of cold trap dewars using portable nitrogen dewars) and a cryogen-free 4 K cold trap, which eliminates the need for a bath of liquid helium.

43 PARTICLE ACCELERATORS↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗