Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

The Discovery of a Gravitationally Lensed Supernova Ia at Redshift 2.22

Here, we present the discovery and measurements of a gravitationally lensed supernova (SN) behind the galaxy cluster MOO J1014+0038. Based on multi-band Hubble Space Telescope and Very Large Telescope (VLT) photometry of the supernova, and VLT spectroscopy of the host galaxy, we find a 97.5% probability that this SN is a SN Ia, and a 2.5% chance of a CC SN. Our typing algorithm combines the shape and color of the light curve with the expected rates of each SN type in the host galaxy. With a redshift of 2.2216, this is the highest redshift SN Ia discovered with a spectroscopic host-galaxy redshift. A further distinguishing feature is that the lensing cluster, at redshift 1.23, is the most distant to date to have an amplified SN. The SN lies in the middle of the color and light-curve shape distributions found at lower redshift, disfavoring strong evolution to z = 2.22. We estimate an amplification due to gravitational lensing of 2.8 +0.6 -0.5 (1.10 ± 0.23 mag)---compatible with the value estimated from the weak-lensing-derived mass and the mass-concentration relation from LambdaCDM simulations---making it the most amplified SN Ia discovered behind a galaxy cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Anatomy of an transparent optical circulator.

An optical circulator is a multi-port, nonreciprocal device that routes light from one specific port to another. Optical circulators have at least 3 or 4 ports, up to 6 port possible (JDS Uniphase, Huihong Fiber) Circulators do not disregard backward propagating light, but direct it to another port. Optical circulators are commonly found in bi-directional transmission systems, WDM networks, fiber amplifiers, and optical time domain reflectometers (OTDRs). 3-Port optical circulators are commonly used in PDV systems. 1550 nm laser light is launched into Port 1 and will exit out of Port 2 to the target. Doppler-shifted light off the moving surface is reflected back into Port 2 and exits out of Port 3. Surprisingly, a circulator requires a large number of parts to operate efficiently. Transparent circulators offer higher isolation than those of the reflective style using PBSs. A lower PMD is obtained using birefringent crystals rather than PBSs due to the similar path lengths between e and o rays. Many various circulator designs exist, but all achieve the same non-reciprocal results.

99 GENERAL AND MISCELLANEOUS↗

Efficient Energy Funneling in Quasi‐2D Perovskites: From Light Emission to Lasing

Abstract Quasi‐2D Ruddlesden–Popper halide perovskites with a large exciton binding energy, self‐assembled quantum wells, and high quantum yield draw attention for optoelectronic device applications. Thin films of these quasi‐2D perovskites consist of a mixture of domains having different dimensionality, allowing energy funneling from lower‐dimensional nanosheets (high‐bandgap domains) to 3D nanocrystals (low‐bandgap domains). High‐quality quasi‐2D perovskite (PEA) 2 (FA) 3 Pb 4 Br 13 films are fabricated by solution engineering. Grazing‐incidence wide‐angle X‐ray scattering measurements are conducted to study the crystal orientation, and transient absorption spectroscopy measurements are conducted to study the charge‐carrier dynamics. These data show that highly oriented 2D crystal films have a faster energy transfer from the high‐bandgap domains to the low‐bandgap domains (<0.5 ps) compared to the randomly oriented films. High‐performance light‐emitting diodes can be realized with these highly oriented 2D films. Finally, amplified spontaneous emission with a low threshold 4.16 µJ cm −2 is achieved and distributed feedback lasers are also demonstrated. These results show that it is important to control the morphology of the quasi‐2D films to achieve efficient energy transfer, which is a critical requirement for light‐emitting devices.

Lei, Lei↗

Waveguide design for line selection in fiber lasers and amplifiers

Rare earth doped fiber lasers can be robust and efficient sources of high quality light, but are usually limited to the highest gain transitions of the active species. But rare earths typically possess a multitude of potentially useful transitions that might be accessed if the dominant transition can be suppressed. In fiber lasers this suppression is complicated by the very high net gain the dominant transitions exhibit; effective suppression requires some mechanism distributed along the length of the fiber. We have developed a novel waveguide with resonant leakage elements that frustrate guidance at well-defined and selectable wavelengths. Based on this waveguide, we have fabricated a Large Mode Area Neodymium doped fiber with suppression of the four-level transition around 1060 nm, and demonstrated lasing on the three-level transition at 930 nm with good efficiency.

36 MATERIALS SCIENCE↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Femtosecond Timing Noise and Stability in Microwave Components

To probe chemical dynamics, X-ray pump-probe experiments trigger a change in a sample with an optical laser pulse, followed by an X-ray probe. At the Linac Coherent Light Source, LCLS, timing differences between the optical pulse and x-ray probe have been observed with an accuracy as low as 50 femtoseconds. This sets a lower bound on the number of frames one can arrange over a time scale to recreate a 'movie' of the chemical reaction. The timing system is based on phase measurements from signals corresponding to the two laser pulses; these measurements are done by using a double-balanced mixer for detection. To increase the accuracy of the system, this paper studies parameters affecting phase detection systems based on mixers, such as signal input power, noise levels, temperature drift, and the effect these parameters have on components such as the mixers, splitters, amplifiers, and phase shifters. Noise data taken with a spectrum analyzer show that splitters based on ferrite cores perform with less noise than strip-line splitters. The data also shows that noise in specific mixers does not correspond with the changes in sensitivity per input power level. Temperature drift is seen to exist on a scale between 1 and 27 fs/{sup o}C for all of the components tested. Results show that any components using more metallic conductor tend to exhibit more noise as well as more temperature drift. The scale of these effects is large enough that specific care should be given when choosing components and designing the housing of high precision microwave mixing systems for use in detection systems such as the LCLS. With these improvements, the timing accuracy can be improved to lower than currently possible.

43 PARTICLE ACCELERATORS↗

Nonlinear ionization dynamics of hot dense plasma observed in a laser-plasma amplifier

Understanding the behaviour of matter under conditions of extreme temperature, pressure, density and electromagnetic fields has profound effects on our understanding of cosmologic objects and the formation of the universe. Lacking direct access to such objects, our interpretation of observed data mainly relies on theoretical models. However, such models, which need to encompass nuclear physics, atomic physics and plasma physics over a huge dynamic range in the dimensions of energy and time, can only provide reliable information if we can benchmark them to experiments under well-defined laboratory conditions. Due to the plethora of effects occurring in this kind of highly excited matter, characterizing isolated dynamics or obtaining direct insight remains challenging. High-density plasmas are turbulent and opaque for radiation below the plasma frequency and allow only near-surface insight into ionization processes with visible wavelengths. Here, the output of a high-harmonic seeded laser-plasma amplifier using eight-fold ionized krypton as the gain medium operating at a 32.8 nm wavelength is ptychographically imaged. A complex-valued wavefront is observed in the extreme ultraviolet (XUV) beam with high resolution. Ab initio spatio-temporal Maxwell–Bloch simulations show excellent agreement with the experimental observations, revealing overionization of krypton in the plasma channel due to nonlinear laser-plasma interactions, successfully validating this four-dimensional multiscale model. This constitutes the first experimental observation of the laser ion abundance reshaping a laser-plasma amplifier. The presented approach shows the possibility of directly modelling light-plasma interactions in extreme conditions, such as those present during the early times of the universe, with direct experimental verification.

36 MATERIALS SCIENCE↗

Exploring multiband excitations of interacting Bose gases in a one-dimensional optical lattice by coherent scattering

We use a coherent Bragg diffraction method to impart an external momentum to ultracold bosonic atoms trapped in a one-dimensional optical lattice. This method is based on the application of a single light pulse, with conditions where scattering of photons can be resonantly amplified by atomic density grating. An oscillatory behavior of the momentum distribution resulting from the time evolution in the lattice potential is then observed. By measuring the oscillating frequencies, we extract multiband energy structures of single-particle excitations with zero pseudomomentum transfer for a wide range of lattice depths. The excitation energy structures reveal the interaction effect through the whole range of lattice depths.

74 ATOMIC AND MOLECULAR PHYSICS↗

Proton acceleration from targets irradiated by ultraintense high-contrast laser pulses in the SOKOL-P facility

Results of experiments on proton acceleration from aluminum foils and organic films irradiated by laser pulses with intensities of up to 2 x 10{sup 19} W/cm{sup 2} are presented. To prevent thin targets from destruction by the superluminescence prepulse, a fast light shutter based on a Pockels cell was introduced in the amplifying system of the SOKOL-P facility. As a result, the energy contrast with respect to the superluminescence prepulse increased to 4 x 10{sup 6}, which made it possible to carry out experiments on the irradiation of targets with thicknesses less than 100 nm. It is found that the target material insignificantly affects the yield of accelerated protons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chopping-Wheel Optical Attenuator

Star-shaped rotating chopping wheel provides adjustable time-averaged attenuation of narrow beam of light without changing length of optical path or spectral distribution of light. Duty cycle or attenuation factor of chopped beam controlled by adjusting radius at which beam intersects wheel. Attenuation factor independent of wavelength. Useful in systems in which chopping frequency above frequency-response limits of photodetectors receiving chopped light. Used in systems using synchronous detection with lock-in amplifiers.

Leviton, Douglas B.↗

Evaluation of visual acuity with Gen 3 night vision goggles

Using laboratory simulations, visual performance was measured at luminance and night vision imaging system (NVIS) radiance levels typically encountered in the natural nocturnal environment. Comparisons were made between visual performance with unaided vision and that observed with subjects using image intensification. An Amplified Night Vision Imaging System (ANVIS6) binocular image intensifier was used. Light levels available in the experiments (using video display technology and filters) were matched to those of reflecting objects illuminated by representative night-sky conditions (e.g., full moon, starlight). Results show that as expected, the precipitous decline in foveal acuity experienced with decreasing mesopic luminance levels is effectively shifted to much lower light levels by use of an image intensification system. The benefits of intensification are most pronounced foveally, but still observable at 20 deg eccentricity. Binocularity provides a small improvement in visual acuity under both intensified and unintensified conditions.

Bradley, Arthur↗

Accelerator-driven X-ray Sources

After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

43 PARTICLE ACCELERATORS↗

Method of measuring luminescence of a material

A method of measuring luminescence of a material is disclosed. The method includes applying a light source to excite an exposed material. The method also includes amplifying an emission signal of the material. The method further includes measuring a luminescent emission at a fixed time window of about 10 picoseconds to about 10 nanoseconds. The luminescence may be radio photoluminescence (RPL) or optically stimulated luminescence (OSL).

36 MATERIALS SCIENCE↗

Surface engineered nanoparticles for improved surface enhanced Raman scattering applications and method for preparing same

A method for producing metal nanoparticles that when associated with an analyte material will generate an amplified SERS spectrum when the analyte material is illuminated by a light source and a spectrum is recorded. The method for preparing the metal nanoparticles comprises the steps of (i) forming a water-in-oil microemulsion comprising a bulk oil phase, a dilute water phase, and one or more surfactants, wherein the water phase comprises a transition metal ion; (ii) adding an aqueous solution comprising a mild reducing agent to the water-in-oil microemulsion; (iii) stirring the water-in-oil microemulsion and aqueous solution to initiate a reduction reaction resulting in the formation of a fine precipitate dispersed in the water-in-oil microemulsion; and (iv) separating the precipitate from the water-in-oil microemulsion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Black-hole powered quantum coherent amplifier

Abstract Atoms falling into a black hole (BH) through a cavity are shown to enable coherent amplification of light quanta powered by the BH-gravitational vacuum energy. This process can harness the BH energy towards useful purposes, such as propelling a spaceship trapped by the BH. The process can occur via transient amplification of a signal field by falling atoms that are partly excited by Hawking radiation reflected by an orbiting mirror. In the steady-state regime of thermally equilibrated atoms that weakly couple to the field, this amplifier constitutes a BH-powered quantum heat engine. The envisaged effects substantiate the thermodynamic approach to BH acceleration radiation.

Physics↗

First Measurements and Results With a Stretched Wire Test Setup

The LINAC Coherent Light Source [LCLS] is a free electron laser, designed to produce high brilliant X-ray beams using Self Amplified Spontaneous Emission [SASE]. Due to the physics of SASE, the electron beam has to be held very precisely on the same trajectory as the X-ray light beam generated by the undulator magnets. To optimize the SASE output, trajectory deviations between both beams have to be minimized to a few micrometers along the entire undulator section and held stable over the time period between beam-based-alignment processes. Consequently, extremely high position stability of all magnets in the undulator section is required to operate the LCLS successfully. The knowledge of any magnet movement exceeding few micrometers during periods of several weeks is essential for efficient X-ray generation. A well known principle of monitoring transverse component positions along beam lines is the application of stretched wires, associated with suitable wire position sensors and electronics. The particular challenge at LCLS is the required wire system performance in conjunction with the length of the undulator section and the large number of monitors. Verification of system stability and resolution under real conditions is the primary goal of this test setup. A stretched wire test setup has been implemented to gain experience for the final design of a wire system, which will meet the position monitoring requirements in the LCLS undulator section. The report briefly introduces the system's architecture and describes first measurements and results.

43 PARTICLE ACCELERATORS↗