Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-T-91: Correction Method to Determine Surface Dose for OSL Detectors

Purpose: OSL detectors are commonly used in clinic due to their numerous advantages, such as linear response, negligible energy, angle and temperature dependence in clinical range, for verification of the doses beyond the dmax. Although, due to the bulky shielding envelope, this type of detectors fails to measure skin dose, which is an important assessment of patient ability to finish the treatment on time and possibility of acute side effects. This study aims to optimize the methodology of determination of skin dose for conventional accelerators and a flattening filter free Tomotherapy. Methods: Measurements were done for x-ray beams: 6 MV (Varian Clinac 2300, 10×10 cm{sup 2} open field, SSD = 100 cm) and for 5.5 MV (Tomotherapy, 15×40 cm{sup 2} field, SAD = 85 cm). The detectors were placed at the surface of the solid water phantom and at the reference depth (dref=1.7cm (Varian 2300), dref =1.0 cm (Tomotherapy)). The measurements for OSLs were related to the externally exposed OSLs measurements, and further were corrected to surface dose using an extrapolation method indexed to the baseline Attix ion chamber measurements. A consistent use of the extrapolation method involved: 1) irradiation of three OSLs stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. Results: OSL measurements showed an overestimation of surface doses by the factor 2.31 for Varian 2300 and 2.65 for Tomotherapy. The relationships: SD{sup 2300} = 0.68 × M{sup 2300}-12.7 and SDτoμo = 0.73 × Mτoμo-13.1 were found to correct the single OSL measurements to surface doses in agreement with Attix measurements to within 0.1% for both machines. Conclusion: This work provides simple empirical relationships for surface dose measurements using single OSL detectors.

60 APPLIED LIFE SCIENCES↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

Status and results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay [0$vββ$] of 130 Te. The detector consists of a segmented array of 988 natural TeO 2 cubic crystals arranged in a cylindrical compact structure of 19 towers. The detector construction was completed in August 2016 and data taking started in Spring 2017. Here, we present a brief description of the bolometric technique for rare events search and the CUORE detector, then we concentrate on the data analysis results. In this respect, we focus on the procedure for data processing and on the first 0$vββ$ results we obtained from a total TeO 2 exposure of 86.3 kg · yr. Next, we illustrate the main background sources and the CUORE background model, from which we obtain the most precise measurement of 130 Te 2$vββ$ half-life to date. Finally, we discuss the improvements achieved with 2018 and 2019 detector optimization campaigns and the current perspectives of our experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update of CEA DES Criticality-Safety Activities and Perspectives [Slides]

Neutronics staff at CEA DES are in charge of a whole set of modeling and simulation tools for neutronics: nuclear data evaluation and processing, transport codes development, calculation sequences edition, verification, validation and uncertainty analysis. Advanced user groups are in charge of specific nuclear analysis in reactor physics, fuel cycle, criticality-safety, radiation shielding and nuclear instrumentation for CEA and its partners, at all stages of nuclear facilities life cycle. CEA is willing to participate/collaborate on the following issues: detector design, experiments, analysis and evaluation, DH validation by combining TAGS measurements with Fission Yield variance-covariance matrices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The influence of modifications of a fatigue loading history program on fatigue lifetime

Rectangular specimens of 7075 and 2014 aluminum alloys with two holes (stress concentration factor of 3.24) have been tested under axial fatigue loading on a six-rod test bed with modifications of the loading program, the surface particulars, and the frequency. The length of the precrack stage was investigated by use of a new crack detector. In most cases the two alloys behaved similarly, with similar life to crack start under the same loading. Some overloads lengthened the life. Truncation by omission of the lowest peak loads should be limited to about 20 percent of the ultimate load. Simplifying counting methods gave misleading results. Very thin surface layers of anodizing, protection by vinyl, dry nitrogen atmosphere, as well as stepwise reaming or grinding the surface of the holes, lengthened the life; thick anodized layers shortened the life. Compressing the hole surface by rolling had no influence. Frequencies at about 210 to 240 cpm produced shorter lives than those at 40 cpm. At 5.4 cpm the life was considerably longer. A model to better understand the precrack-stage fatigue mechanism is discussed.

Branger, J.↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

Procurement of 100 kg of Enriched Xenon for the EXO Prototype and for its Installation at WIPP

This grant supported the enriched xenon procurement, detector construction and initial operation of the EXO-200 double beta decay experiment at the Waste Isolation Pilot Plant (WIPP). The period of performance was Aug 15, 2002 to Dec 31, 2014. The primary goal of the experiment is to search for the very rare (and to date not observed) neutrino-less double beta decay. Such decay, if observed, would shed the light of the quantum-mechanical structure of neutrinos, and the origins of elementary particle masses. Another goal of the detector is to serve as prototype of a larger neutrino-less double beta decay experiment, currently being considered by DOE-OS. EXO-200 has already been extremely successful in both areas and is, in fact, leading the way world-wide in this area of fundamental physics. In the initial part of the grant the EXO-200 collaboration acquired 200kg of xenon enriched to 80% in the isotope 136 that is a candidate for double beta decay. At the time this was the largest isotope separation program carried out for fundamental science. The enrichment was done in Russia, providing a rare and valuable opportunity for US scientists to work alongside Russian colleagues, in some cases from the former closed cities of their military complex. By now the EXO-200 collaboration include institutions from the US, Canada, South Korea, China, Germany, Switzerland and Russia. Many collaborating scientists from these countries have taken shifts at WIPP or at the various remote monitoring sites world-wide. EXO-200 detector construction was completed in early 2010, with the time projection chamber (TPC) installation in the cleanrooms already placed in NeXA. Detector commissioning at WIPP followed, with the last phase, the filling of the TPC with liquid Xenon, occurring in the spring 2011. EXO-200 is described in [1]. Low background data taking started on Jun 1, 2011 and within the first month of data the 2-neutrino double beta decay of 136Xe was discovered, as reported in [2]. More data provided the best half-life measurement of any 2-neutrino double-beta decay modes [3]. Until Feb 2014 the detector ran continuously producing some of the world leading results in the field and, in particular, two of the most sensitive searches for neutrinoless double beta decay [4,5]. These measurements show that the half life of this decay is longer than 1015 times the age of the universe. This is one of the leading results in this field world-wide and succeeded to put the DOE-funded research on the world stage in a very cost-effective way. Other results from EXO-200 include a search for exotic double-beta decay modes [6], a detailed report on the state of the art background levels achieved in the detector [7], the study of rare ion and neutral atom motion and neutralization rates in liquid Xenon [8], a study of the cosmogenic backgrounds in the detector at WIPP’s depth [9], a search for Lorentz and CPT symmetries violation [10] and a search for double-beta decay to excited states [11]. In Feb 2014 the EXO-200 detector was severely disrupted by the accidents in the WIPP underground (unrelated to EXO-200). The EXO-200 operations team was able to recover the unique stockpile of enriched Xenon to high pressure cylinders and warm-up the detector to room temperature without damaging the very delicate equipment. This was a very impressive achievement as no plan had been made to complete these operations entirely from remote. This validates the robustness of well-designed liquid xenon detectors for this and other measurements in particle and nuclear astrophysics. The operations team re-gained almost regular access to the WIPP underground and the EXO-200 detector in Jan 2015 and spent calendar 2015 cleaning up the soot from the WIPP fire, assessing the damage to the EXO-200 infrastructure, correcting such damage and restarting the detector. This process was successfully carried out and culminated in the re-filling of the detector with liquid xenon, in Jan 2016. As of late Jan 2016 EXO-200 is taking data again. The collaboration is in the process of upgrading the readout electronics and restarting a radon abatement system that had been commissioned just before the Feb 2014 events. The upgraded electronics will provide lower readout noise and, in turn, better signal to background discrimination. The radon abatement system will further reduce the radon in a small air-gap between the EXO-200 cryostat and the lead shielding. In a review in Jun 2015 DOE-OS approved EXO-200 for 2.5 more years of running at the end of which we expect to improve the sensitivity to the neutrino-less double-beta decay by a factor two or three. For the last 5 years the EXO-200 detector, located in the WIPP underground, has been at the center of the hunt for new physics beyond the Standard Model of particle physics!

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and prospects of discovery of 0νββ decay with the CUORE detector

In this contribution we present the achievements of the CUORE experiment so far. It is the first tonne-scale bolometric detector and it is in stable data taking since 2018. We reached to collect about 1800 kg×yr of exposure of which more than 1 ton×year have been analysed. The CUORE detector is meant to search for the neutrinoless double β decay (0νββ) of the 130 Te isotope. This is a beyond Standard Model process which could establish the nature of the neutrino to be Dirac or a Majorana particle. It is an alternative mode of the two-neutrinos double β decay, a rare decay which have been precisely measured by CUORE in the 130 Te. We found no evidence of the 0νββ and we set a Bayesian lower limit of 2.2 ×10 25 yr on its half-life. The expertise achieved by CUORE set a milestone for any future bolometric detector, including CUPID, which is the planned next generation experiment searching for 0νββ with scintillating bolometers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automatic Construction of Anomaly Detectors from Graphical Models

Detection of rare or previously unseen attacks in cyber security presents a central challenge: how does one search for a sufficiently wide variety of types of anomalies and yet allow the process to scale to increasingly complex data? In particular, creating each anomaly detector manually and training each one separately presents untenable strains on both human and computer resources. In this paper we propose a systematic method for constructing a potentially very large number of complementary anomaly detectors from a single probabilistic model of the data. Only one model needs to be trained, but numerous detectors can then be implemented. This approach promises to scale better than manual methods to the complex heterogeneity of real-life data. As an example, we develop a Latent Dirichlet Allocation probability model of TCP connections entering Oak Ridge National Laboratory. We show that several detectors can be automatically constructed from the model and will provide anomaly detection at flow, sub-flow, and host (both server and client) levels. This demonstrates how the fundamental connection between anomaly detection and probabilistic modeling can be exploited to develop more robust operational solutions.

anomaly detection↗

Proton-induced x-ray fluorescence CT imaging

Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm{sup 2} CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R{sup 2} > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a small animal sized water phantom has been demonstrated for the first time by means of experiments and MC simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from phase I of the GERDA experiment

The GERmanium Detector Array Gerda at the Laboratori Nazionali del Gran Sasso of the INFN in Italy is an experiment dedicated to the search for the neutrinoless double beta (0νββ) decay in {sup 76}Ge. The experiment employs high purity germanium detectors enriched in {sup 76}Ge inside a 64 m{sup 3} cryostat filled with liquid argon. Gerda was planned in two phases of data taking with the goal to reach a half-life sensitivity in the order of 10{sup 26} yr. Phase I of Gerda was running from November 2011 until May 2013. With about 18 kg total detector mass, data with an exposure of 21.6 kg·yr was collected and a background index of 0.01 cts/(keV·kg·yr) was achieved in the region of interest. No signal was found for the 0νββ decay and a new limit of T{sub 1/2} > 2.1 · 10{sup 25} yr (90% C.L.) was obtained, strongly disfavoring the previous claim of observation. Furthermore, the 2νββ decay half-life of {sup 76}Ge was measured with unprecedented precision. Other results include new half-life limits of the order of 10{sup 23} yr for Majoron emitting double beta decay modes with spectral indices n = 1, 2, 3, 7 and new limits in the order of 10{sup 23} yr for 2νββ decays to the first 3 excited states of {sup 76}Se. In Phase II, currently in preparation, the detector mass will be doubled while reducing the background index by a factor of 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-249: Neutron Model Upgrade for Radiotherapy Patients Monitoring Using a New Online Detector

Purpose: The purpose of this work is to improve the existing methodology to estimate neutron equivalent dose in organs during radiotherapy treatments, based on a Static Random Access Memory neutron detector (SRAMnd) [1]. This is possible thanks to the introduction of a new digital detector with improved characteristics, which is able to measure online the neutron fluence rate in the presence of an intense photon background [2]. Its reduced size, allows the direct estimation of doses in specific points inside an anthropomorphic phantom (NORMA) without using passive detectors as TLD or CR-39. This versatility will allow not only to improve the existing models (generic abdomen and H and N [1]) but to generate more specific ones for any technique. Methods: The new Thermal Neutron Rate Detector (TNRD), based on a diode device sensitized to thermal neutrons, have been inserted in 16 points of the phantom. These points are distributed to infer doses to specific organs. Simultaneous measurements of these devices and a reference one, located in front of the gantry, have been performed for the mentioned generic treatments, in order to improve the existing model. Results: These new devices have shown more precise since they agree better with Monte Carlo simulations. The comparison of the thermal neutron fluence, measured with TNRD, and the existing models, converted from events to fluence, shows an average improvement of (3.90±3.37) % for H and N and (12.61±9.43) % for abdomen, normalized to the maximum value. Conclusion: This work indicates the potential of these new devices for more precise neutron equivalent dose estimation in organs, as a consequence of radiotherapy treatments. The simplicity of the process makes possible to establish more specific models that will provide a better dose estimation. References[1] Phys Med Biol 2012; 57:6167–6191.[2] A new active thermal neutron detector. Radiat. Prot. Dosim. (in press)

60 APPLIED LIFE SCIENCES↗

Sensitivity of NEXT-100 to neutrinoless double beta decay

NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0νββ) decay of $^{136}$Xe. The detector possesses two features of great value for 0νββ searches: energy resolution better than 1% FWHM at the Q value of $^{136}$Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10$^{–4}$ counts keV$^{–1}$ kg$^{–1}$ yr$^{–1}$. Furthermore, the detector will reach a sensitivity to the 0νββ-decay half-life of 2.8 × 10$^{25}$ years (90% CL) for an exposure of 100 kg·year, or 6.0 × 10$^{25}$ years after a run of 3 effective years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Rare Nuclear Processes with CUORE

TeO 2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO 2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$ meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130 Te and the hypothesized electron capture in 123 Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO 2 bolometers, and perspectives for CUORE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simple gas chromatographic system for analysis of microbial respiratory gases

Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

Carle, G. C.↗

Laboratory Astrophysics White Paper

Laboratory astrophysics and complementary theoretical calculations are the foundations of astronomical and planetary research and will remain so for many generations to come. From the level of scientific conception to that of the scientific return, it is our understanding of the underlying processes that allows us to address fundamental questions regarding the origins and evolution of galaxies, stars, planetary systems, and life in the cosmos. In this regard, laboratory astrophysics is much like detector and instrument development at NASA and NSF; these efforts are necessary for the astronomical research being funded by the agencies. The NASA Laboratory Astrophysics Workshop met at the University of Nevada, Las Vegas (UNLV) from 14-16 February, 2006 to identify the current laboratory data needed to support existing and future NASA missions and programs in the Astrophysics Division of the Science Mission Directorate (SMD). Here we refer to both laboratory and theoretical work as laboratory astrophysics unless a distinction is necessary. The format for the Workshop involved invited talks by users of laboratory data, shorter contributed talks and poster presentations by both users and providers that highlighted exciting developments in laboratory astrophysics, and breakout sessions where users and providers discussed each others' needs and limitations. We also note that the members of the Scientific Organizing Committee are users as well as providers of laboratory data. As in previous workshops, the focus was on atomic, molecular, and solid state physics.

Brickhouse, Nancy↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Volume III. DUNE far detector technical coordination

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗