At least 199 records · Page 11

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Optics Studies for Multipass Energy Recovery at CEBAF: ER@CEBAF

Energy recovery linacs (ERLs), focus on recycling the kinetic energy of electron beam for the purpose of accelerating a newly injected beam within the same accelerating structure. The rising developments in the super conducting radio frequency technology, ERL technology has achieved several noteworthy milestones over the past few decades. In year 2003, Jefferson Lab has successfully demonstrated a single pass energy recovery at the CEBAF accelerator. Furthermore, they conducted successful experiments with IR-FEL demo and upgrades, as well as the UV FEL driver. This multi-pass, multi-GeV range energy recovery demonstration proposed to be carried out at CEBAF accelerator at Jefferson Lab focuses on demonstrating highest energy recovery in super conducting linac in the low-current range. Continuous electron beam accelerate up to 7.5 GeV within 5-passes and decelerate in the next 5-passes recovering RF energy and dumps at a low energy dump. The beamline optics design for recirculating linacs require special attention to avoid beam instabilities due to RF wakefields. Usually, multi-pass linac beam lines require stronger focusing at lower energies as that is necessary to avoid beam breakup (BBU) instabilities, even with this small beam current. The CEBAF linac optics optimization is focused on balancing over-focusing at higher energies and beta excursions at lower energies. The race-track-shaped geometry of CEBAF accelerator allows its linacs to accommodate multiple energy beams simultaneously, while individual recirculating arcs transporting one beam energy, are shared between accelerating/decelerating beams. For the linac optics optimization process, an extended strategy is used that is originally used in 6-pass Recirculating Linac design of the LHeC, to represent the ten passes through a single linac. Using proper mathematical expressions, linac optics optimization can be achieved with evolutionary genetic algorithms, with Multi-Objective optimization. This thesis introduces a CEBAF optics redesign tailored to accommodates the ER@CEBAF multi-pass ER scheme. The isochronous arcs were retuned to match into optics solutions for optimized 10-pass linacs. Within this work, a single bunch particle tracking analysis presented here focuses on the further improvements of the beamline and beam transportation.

Neththikumara, Isurumali↗

A High Power Prototype of a Harmonic Kicker Cavity

A harmonic kicker, a beam exchange device that can deflect the beam at an ultra-fast time scale (a few ns), has been developed in Jefferson Lab *, **. The high power prototype that can deliver more than a 100 kV kick at 7 kW was fabricated. The RF performance of cavity such as the harmonic resonant frequencies, kick profiles, it’s stability, and electric center is tested at bench. The cavity will eventually be tested with a beam at Upgraded Injector Test Facility (UITF) in Jefferson Lab. In this paper, we report some features of fabrication and bench test results. We also briefly describe our beam test plan in the future.

Park, Gunn↗

Metastability exchange optical pumping of 3 He at low pressure and high magnetic field

We report systematic studies on metastability exchange optical pumping of 3 He nuclei have been performed at Jefferson Lab using a 1-torr sealed cell at magnetic fields from 2 to 4 T. The effects of the discharge intensity, pump laser power and pumping transition schemes on achievable nuclear polarization and pumping rate have been investigated. A maximum steady-state nuclear polarization of about 75% has been obtained. This work provides a baseline for the development of the novel polarized 3 He target for CLAS12 at Jefferson Lab.

47 OTHER INSTRUMENTATION↗

A High-Magnetic-Field Polarized 3He Target for JLab's CLAS12 Spectrometer

We are developing a polarized 3He target for use in high luminosity electron scattering experiments within the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping (MEOP) of 3He with cryogenic, double-cell target methods as used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic field environments. We have begun polarizing sealed 3He cells at fields up to 5 T at Jefferson Lab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target. A key focus of our research is the determination of polarization relaxation under the irradiation of an ionizing particle beam within high magnetic fields.

Maxwell, James↗

Design of a shipping fixture for a compact cryomodule hermetic assembly

In support of the development of a conduction-cooled 915MHz superconducting radio frequency (SRF) cryomodule, this study highlights the design of a shipping fixture for transporting the hermetic assembly 4500 km from Jefferson Lab to General Atomics in San Diego, California. The hermetic assembly consists of a 2-cell 915 MHz SRF cavity, a coaxial fundamental power coupler and warm-to-cold transition beam tubes. The two-part shipping assembly consists of an inner frame, providing direct mounting of the components, and an outer frame mounted to the ground transport vehicle. The inner frame is then connected to the outer frame by way of wire-rope isolators. Accelerometer data from ground transportation of previous projects at Jefferson Lab provides the baseline for the expected frequency and magnitude of vibrational and shock events during transit. Modal analyses were carried out in ANSYS on the inner frame assembly and critical components to identify an appropriate wire-rope isolator configuration such that peak loads are mitigated and the incurred frequencies do not correspond with the fundamental modes of the structures.

Accelerator Physics↗

Status of 22 GeV CEBAF Upgrade Using FFA Arcs

Jefferson Lab is exploring an upgrade to extend CEBAF’s energy to ~22 GeV within the existing tunnel by incorporating Fixed-Field Alternating-Gradient (FFA) arcs. In this scheme, the two lowest-energy electromagnetic arcs are removed, the remaining arcs are reassigned to lower energies, and a new pair of high-energy FFA arcs enables six additional recirculations using the existing SRF linacs. The non-scaling FFA lattice employs Halbach-derived permanent magnets with provisions for dipole, quadrupole, and higher-order components, offering large momentum acceptance and reduced operating cost. Implementing this concept requires updated linac optics, modifications to the remaining arcs, and a redesigned electromagnetic switchyard. Ongoing beam-dynamics studies address synchrotron-radiation–induced energy loss and emittance growth, along with strategies for their mitigation.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Developing New Q-meters for NMR Measurements of Polarized Solids

Enhanced polarization of target nuclei can be measured via the complex impedance of a resonant circuit coupled to the target while sweeping the circuit through the nuclear Larmor frequency, observing the absorption or emission of energy by the spins in the material. For decades, solid polarized targets at Jefferson Lab have relied upon continuous-wave Nuclear Magnetic Resonance polarization measurements using Liverpool Q-meter systems. These Liverpool Q-meters are no longer produced, and replacing the aging components is becoming increasingly difficult. The polarized target group at Bochum has produced replacement Q-meters in the Liverpool style using modern components, and we are following their example while researching improvemnts to the technique. We discuss our efforts to produce improved Q-meters for upcoming experiments utilizing solid polarized targets in Jefferson Lab's Hall B.

Maxwell, James↗

Polarization options in inclusive DIS off tensor polarized deuteron

In the near future, the Jefferson Lab b 1 experiment will provide the second measurement of tensor polarized asymmetries in inclusive DIS on the deuteron. In this asymmetry, 4 independent tensor polarized structure functions contribute. This necessitates systematic approximations in the extraction of the leading twist structure function b 1 from a single tensor asymmetry measurement. Contamination from higher twist structure functions and kinematic effects is discussed here. Using a deuteron convolution model, we quantify the systematic errors from these approximations for two different choices for the target polarization direction (momentum transfer, electron beam direction). For Jefferson Lab 12 GeV kinematics, the systematic error turns out to be comparable between the two polarization options, while at higher Q 2 values the momentum transfer direction is preferred.

Cosyn, Wim [Florida International University, Miam↗

Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps

Jefferson Lab (JLab) will collaborate with Radiabeam, LLC in a DOE SBIR Phase II Project (DOE Grant No. DE-SC0019684, title: “Ultrafast High Voltage Kicker System Hardware for Ion Clearing Gaps”) to develop and test a MHz high voltage nanosecond kicker system that enables the time structure required by the ion traps for high current electron beam cooling. High current (in particular energy recovery) linac based electron cooling facilities for medium to high energy bunched proton or ion beams are of great interest for the recently funded Electron-Ion Collider (EIC) to which Jefferson Lab plays a critical role. The successful execution of this project will enable the capability to mitigate the ion trapping effect and circumvent a major obstacle preventing reliable operation of the crucial cooling facilities.

43 PARTICLE ACCELERATORS↗

Status of permanent magnet radiation resiliency studies at CEBAF

An ongoing investigation for the future of Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) lies in upgrading its maximum nominal energy using Fixed-Field Alternating-gradient (FFA) technology for its recirculating arcs, using permanent magnets for the FFA arcs. A common concern among the community is the degradation of these permanent magnets during operation due to the radiation environment in which they will be present. This work, funded by a Laboratory Directed R&D grant, aims to measure the permanent magnet degradation in the CEBAF tunnel enclosure, and extrapolate to the energies expected from the upgrade. We present the latest results of this study, as well as plans moving forward.

Accelerator Physics↗

Advanced extraction of the deuteron charge radius from electron-deuteron scattering data

To extract the charge radius of the proton, $r_{p}$, from the electron scattering data, the PRad collaboration at Jefferson Lab has developed a rigorous framework for finding the best functional forms - the fitters - for a robust extraction of $r_{p}$ from a wide variety of sample functions for the range and uncertainties of the PRad data. In this work we utilize and further develop this framework. Herein we discuss methods for searching for the best fitter candidates as well as a procedure for testing the robustness of extraction of the deuteron charge radius, $r_{d}$, from parameterizations based on elastic electron-deuteron scattering data. The ansatz proposed in this paper for the robust extraction of $r_{d}$, for the proposed low-$Q^{2}$ DRad experiment at Jefferson Lab, can be further improved once there are more data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

Polarized Structure Function {sigma}LT from {pi}0 p Electroproduction Data in the Resonance Region at 0.4 GeV2 < Q2 < 1.0 GeV2

The first results on the sigma(LT') structure function in exclusive pi(0)p electroproduction at invariant masses of the final state of 1.5 GeV < W < 1.8 GeV and in the range of photon virtualities 0.4 GeV2 < Q(2) < 1.0 GeV2 were obtained from data on beam spin asymmetries and differential cross sections measured with the CLAS detector at Jefferson Lab. The Legendre moments determined from the sigma(LT') structure function have demonstrated sensitivity to the contributions from the nucleon resonances in the second and third resonance regions. These new data on the beam spin asymmetries in pi(0)p electroproduction extend the opportunities for the extraction of the nucleon resonance electro-excitation amplitudes in the mass range above 1.6 GeV.

Isupov, E. L.↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Modeling for the phased injector upgrade for 12 GeV CEBAF

The upcoming Jefferson Lab K-Long experiment at Hall D will require unique beam conditions with a much lower bunch repetition rate and atypically high bunch charge. To optimize the Continuous Electron Beam Accelerator Facility (CEBAF) injector for this experiment, we performed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) to determine the magnetic elements and RF settings necessary for the K-long bunch charge (0.64 pC) at 200 kV. We also investigated the transmission and beam characteristics of low to high charge per bunch electron beams through the injector for simultaneous operations of all four CEBAF Halls and characterized the transmission as a function of the photocathode laser spot size and pulse length. Our findings provide valuable insights into optimizing the CEBAF injector for the Jefferson Lab K-Long experiment, as well as for other experiments with similar beam conditions

Kazimi, R.↗