Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab

Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

Overview of Spin Structure Program at Jefferson Lab

An extensive experimental program to study spin physics at low and moderate four - momentum transfer, Q{sup 2}, has been pursued by Jefferson Lab during the last 15 years, with complementary measurements taking place in all 3 experimental halls. Our inclusive data with high statistical precision and extensive kinematic coverage allow us to better constrain the polarized parton distributions, to accurately determine various moments of spin structure functions, to test the spin content of valent quarks, and to investigate the effects of resonance excitations and higher twist, dominant in this kinematic regime. Our recent semi-inclusive and exclusive measurements have given us new avenues of exploration, and inspired a new generation of experiments planned with 12 GeV beam. Highlights from 6 GeV experimental program are discussed, along with the 12 GeV data projections, and expected impact on the NLO global fits and phenomenological models of valent spin structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The hypernuclear physics program at Jefferson Lab

Missing mass spectroscopy of Λ hypernuclei using the (e, e' K⁺) re action has been performed in the past at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) by several experiments in Halls A and C. A new experimen tal campaign is expected to start running in 2026 in Hall C and to provide the first study of the isospin dependence in medium-mass hyperisotopes by populating $^{40}_Λ{K}$ and $^{48}_Λ{K}$ using isotopically enriched calcium targets [E12-15-008]. During this cam paign, it will be possible to study Λ interactions in nuclear matter using a lead target [E12-20-013]. Solid-state targets made of lithium, beryllium, boron [LOI12-23-013], and aluminum [LOI12-23-016] are considered to be included in the campaign. The use of the HKS and HES spectrometers together with thin target foils and high beam currents leads to a sub-MeV energy resolution, significantly better than in hadron beam experiments. Valuable information on few-body hyperon systems would be gained if helium targets were used [E12-19-002]. Using an additional spectrometer for measuring the decay-pion spectra could give access to the binding energies of light hyperfragments [LOI12-23-011]. The measurement of precise and accurate en ergy spectra of different hyperisotopes probes the Λ-N interaction in nuclei including the Λ-N-N interaction. The latter is assumed to play a key role for the stiffness of the nuclear equation of state relevant for the stability of neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter↗

The Meson Spectroscopy Program Using the Forward Tagger with CLAS12 at Jefferson Lab

The 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new generation of experiments in hadronic nuclear physics at Jefferson Lab, seeking to address fundamental questions in QCD. For example, confirming the existence of exotic states, suggested by both quark models and lattice calculations, would allow gluonic degrees of freedom to be explored, and may help explain the role played by gluons in the QCD interaction. In Experimental Hall B, meson spectroscopy (the MesonEx experiment) will be performed using low Q2 electron scattering to produce quasi-real photons. The scattered electron is detected at small angles by the Forward Tagger device, determining the properties of the photon on an event-by-event basis. This technique has notable advantages over real photon beams, and over hadronic beam experiments, where most experimental data exists. This article will focus on the development of the Forward Tagger by the INFN Genova group, and the proposed MesonEx experiment.

Fegan, Stuart↗

The search for QCD in nuclei: A Jefferson lab perspective

We discuss the phenomenon of Color Transparency, and give an overview of the extensive experimental searches for signatures of QCD in nuclei at Jefferson Lab, Hall-C. The results from protons, pions and kaons are compared with each other and with results from hadron scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Beam-Beam Effect and its Consequences for the Jefferson Lab EIC

In this work we address the effect of beam jitter on emittance growth as caused by the beam-beam effect on the Jefferson Lab Electron Ion Collider (JLEIC). This proposed collider would collide up to 100 GeV proton beams with up to 10 GeV electron beams. Due to the asymmetric rigidities of the beams and their non-linear lensing action on each other during a collision, collective effects can limit beam storage times. Using simulations we determined that one of JLEIC’s synchronization concepts would require a new set of software tools to accurately understand phase space evolution.

Nissen, Edward↗

The New 2nd-Generation SRF R&D Facility at Jefferson Lab: TEDF

The US Department of Energy has funded a near-complete renovation of the SRF-based accelerator research and development facilities at Jefferson Lab. The project to accomplish this, the Technical and Engineering Development Facility (TEDF) Project has completed the first of two phases. An entirely new 3,100 m{sup 2} purpose-built SRF technical work facility has been constructed and was occupied in summer of 2012. All SRF work processes with the exception of cryogenic testing have been relocated into the new building. All cavity fabrication, processing, thermal treatment, chemistry, cleaning, and assembly work is collected conveniently into a new LEED-certified building. An innovatively designed 800 m2 cleanroom/chemroom suite provides long-term flexibility for support of multiple R&D and construction projects as well as continued process evolution. The characteristics of this first 2nd-generation SRF facility are described.

43 PARTICLE ACCELERATORS↗

Spectrometer Optics Calibration for Jefferson Lab $ g_2^ p $ Experiment

The proton spin-dependent structure function gp2 in the resonance region has been measured in a recent experiment at Jefferson Lab's Hall A. The goal of this experiment is to determine the gp2 structure function in the Q2 region of 0.02-0.20 GeV2 by using a transversely polarized NH3 target. The Hall A High Resolution Spectrometers (HRS) were used to provide an inclusive measurement of scattered electrons at 5.69 deg. A pair of septum magnets were used to bend the 5.69 deg scatted electrons into the 12.5 deg spectrometers. A full optics calibration of the spectrometer is required to extract the kinematic quantities at the interaction vertex. However, the calibration procedure is challenging due to the complications from the strong transverse target field (2.5 T and 5.0 T) and the varied field configurations of the septum magnets. The details of the optics calibration and the progress will be described in this talk.

Gu, Chao↗

Radiation and ionization energy loss simulation for the GDH sum rule experiment in Hall-A at Jefferson Lab

The radiation and ionization energy loss are presented for single arm Monte Carlo simulation for the GDH sum rule experiment in Hall-A at Jefferson Lab. Radiation and ionization energy loss are discussed for $^{12}C$ elastic scattering simulation. The relative momentum ratio $\frac{\Delta p}{p}$ and $^{12}C$ elastic cross section are compared without and with radiation energy loss and a reasonable shape is obtained by the simulation. The total energy loss distribution is obtained, showing a Landau shape for $^{12}C$ elastic scattering. This simulation work will give good support for radiation correction analysis of the GDH sum rule experiment.

43 PARTICLE ACCELERATORS↗

Separated pi0 electroproduction cross sections off the nucleon at Jefferson Lab Hall A

We report final results for L/T separated pi0 electroproduction cross sections off the proton, the neutron and the deuteron, measured in Hall A of Jefferson Lab. We found a large transverse response for both the proton and neutron cases, pointing to a possible dominance of higher-twist transversity GPD contributions. For the first time, a flavor decomposition of the u and d quark contributions to the cross section will be shown.

Sabatie, Franck↗

A High-Magnetic-Field Polarized 3He Target for Jefferson Lab’s CLAS12 Spectrometer

We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.

Maxwell, James↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scaling behavior in exclusive meson photoproduction from Jefferson Lab at large momentum transfers

With the availability of new high-statistics and wide-angle measurements for several exclusive non-πN meson photoproduction channels from Jefferson Lab, we examine the fundamental scaling law of 90° scattering in QCD that was originally derived in the high-energy perturbative limit. The data show scaling to be prominently visible even in the medium-energy domain of 2.5 GeV ≲√s≲2.84 GeV, where √s is the center-of-mass energy. While constituent quark exchange suffices for pseudoscalar mesons, additional gluon exchanges from higher Fock states of the hadronic wave functions appear be needed for vector-meson production. Finally, the case of the Φ(1020), where two-gluon exchanges are known to dominate, is especially illuminating.

Dey, Biplab↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab: an update on PR12-16-001

This document is an update to the proposal PR12-16-001 Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab submitted to JLab-PAC44 in 2016 reporting progress in addressing questions raised regarding the beam-on backgrounds. The concerns are addressed by adopting a new simulation tool, FLUKA, and planning measurements of muon fluxes from the dump with its existing shielding around the dump. First, we have implemented the detailed BDX experimental geometry into a FLUKA simulation, in consultation with experts from the JLab Radiation Control Group. The FLUKA simulation has been compared directly to our GEANT4 simulations and shown to agree in regions of validity. The FLUKA interaction package, with a tuned set of biasing weights, is naturally able to generate reliable particle distributions with very small probabilities and therefore predict rates at the detector location beyond the planned shielding around the beam dump. Second, we have developed a plan to conduct measurements of the muon ux from the Hall-A dump in its current configuration to validate our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗