Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverted potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

High Efficiency Inverted GaAs and GaInP/GaAs Solar Cells With Strain-Balanced GaInAs/GaAsP Quantum Wells

High-efficiency solar cells are essential for high-density terrestrial applications, as well as space and potentially vehicle applications. The optimum bandgap for the terrestrial spectrum lies beyond the absorption range of a traditional dual junction GaInP/GaAs cell, with the bottom GaAs cell having higher bandgap energy than necessary. Lower energy bandgaps can be achieved with multiple quantum wells (QWs), but such a pathway requires advanced management of the epitaxial growth conditions in order to be useful. Strain-balanced GaAsP/GaInAs QWs are incorporated into a single junction GaAs solar cell and a dual junction GaInP/GaAs solar cell, leading to 27.2% efficiency in the single junction device and a one-sun record 32.9% efficiency in the tandem device. Good carrier collection and low non-radiative recombination are observed in the cells with up to 80 QWs. The GaAs cells employ a rear-heterojunction architecture to boost the open-circuit voltage to over 1.04 V in the quantum well device, despite the large number of QWs.

14 SOLAR ENERGY↗

Na-functionalized Ir Te 2 monolayer: Suppressed charge ordering and electric field tuned topological phase transition

Two-dimensional materials with atomic thickness usually possess superior tunability by surface adsorption than their bulk counterparts, showing great promise for novel nanotechnologies. In layered transition-metal dichalcogenide IrTe 2 there exhibits complex structural distortions induced by charge ordering, resulting in difficulties for the applications of its corresponding monolayer material. Here, using first-principles calculations, we demonstrate that depositing Na on the surface of the IrTe 2 monolayer can suppress the structural distortion to form a stable NaIrTe 2 sheet. It naturally breaks the inversion symmetry to enable a Rashba-type spin splitting for potential spintronic applications. In addition, the introduced empty Na s band and the valence band of the IrTe 2 monolayer can be inverted by the application of a perpendicular electric field, achieving a quantum phase transition from normal to topological insulator. Such an electric field-controlled topological phase transition is promising for the realization of topological field-effect transistors. Furthermore, these findings not only provide a feasible approach to stabilizing the IrTe 2 monolayer, but also broaden its applications in spintronics and low-dissipation topoelectronics.

36 MATERIALS SCIENCE↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Retrieval of Dry Snow Parameters from Radiometric Data Using a Dense Medium Model and Genetic Algorithms

In this paper, GA-based techniques are used to invert the equations of an electromagnetic model based on Dense Medium Radiative Transfer Theory (DMRT) under the Quasi Crystalline Approximation with Coherent Potential to retrieve snow depth, mean grain size and fractional volume from microwave brightness temperatures. The technique is initially tested on both noisy and not-noisy simulated data. During this phase, different configurations of genetic algorithm parameters are considered to quantify how their change can affect the algorithm performance. A configuration of GA parameters is then selected and the algorithm is applied to experimental data acquired during the NASA Cold Land Process Experiment. Snow parameters retrieved with the GA-DMRT technique are then compared with snow parameters measured on field.

Tedesco, Marco↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Large inflationary logarithms in a nontrivial nonlinear sigma model

Loops of inflationary gravitons are known to induce large temporal and spatial logarithms that can cause perturbation theory to break down. Nonlinear sigma models possess the same kind of derivative interactions and induce the same sorts of large logarithms, without the complicated index structure and potential gauge problem. Previous studies have examined models with zero field space curvature that can be reduced to free field theories by local, invertible field redefinitions. Here we study a model that cannot be so reduced and still shows the same sorts of large logarithms. Additionally, we compute the evolution of the background at 1-loop and 2-loop orders, and we find the 1-loop β and γ functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of inverted-V auroral precipitation events

The macroscopic properties of inverted V events measured by the Atmospheric Explorer-D satellite are described, along with the spatial distributions and the extents of individual events. The satellite carried 19 detectors, each comprising a cylindrical electrostatic analyzer followed by an electron multiplier. A total of 430 events was recorded, none of which occurred in cusp precipitation. The observed characteristics of the inverted V events are compared with particle distribution properties predicted by a double layer mechanism, an electrostatic shock model, extended field-aligned potential, and anomalous resistivity. Widespread, continuous electric fields were found parallel to the magnetic field lines, and anomalous resistivity was determined as the most favorable mechanism for producing the electron precipitation structure observed.

Hoffman, R. A.↗

Comparison of electric and growth responses to excision in cucumber and pea seedlings. II. Long-distance effects are caused by the release of xylem pressure

Excision of a growing stem causes local wound responses, such as membrane depolarization and growth inhibition, as well as effects at larger distances from the cut. In this study, cucumber hypocotyls were excised 100 mm below the hook, so that the growing region was beyond the reach of the wound-induced depolarization (up to 40 mm). Even at such a distance, the cut still caused a considerable and rapid drop in the hypocotyl growth rate. This growth response is not a direct wound response because it does not result from the cut-induced depolarization and because it can be simulated by root pressure manipulation (using a pressure chamber). The results indicate that the growth response resulted from the rapid release of the xylem pressure upon excision. To test this conclusion we measured the xylem pressure by connecting a pressure probe to the cut surface of the stem. Xylem pressure (Px) was found to be +10 to +40 kPa in cucumber hypocotyls and -5 to -10 kPa or lower in pea epicotyls. Excision of the cucumber hypocotyl base led to a rapid drop in Px to negative values, whereas excision in pea led to a rapid rise in Px to ambient (zero) pressure. These fast and opposite Px changes parallel the excision-induced changes in growth rate (GR): a decrease in cucumber and a rise in pea. The sign of the endogenous xylem pressure also determined whether excision induced a propagating depolarization in the form of a slow wave potential (SWP). Under normal circumstances pea seedlings generated an SWP upon excision whereas cucumber seedlings failed to do so. When the Px in cucumber hypocotyls was experimentally inverted to negative values by incubating the cumber roots in solutions of NaCN or n-ethylmaleimide, excision caused a propagating depolarization (SWP). The experiment shows that only hydraulic signals in the form of positive Px steps are converted into propagating electric SWP signals. These propagating depolarizations might be causally linked to systemic 'wound' responses, which occur independently of the short-distance or direct wound responses.

Non-NASA Center↗

Interconnection and Interoperability Requirements of Hydrogen Assets to Enable Grid Integration

Traditionally, the inverters used for distributed energy resources (DERs) including solar, energy storage and hydrogen fuel cells are grid following assets. Grid following assets track real power and reactive power setpoints decided by either a local autonomous controller or a remote controller like a microgrid controller. In the past five years, multiple challenges have increased the need for grid forming inverters that can interface to a wide variety of energy resources. These grid forming inverters are becoming critical assets for power systems to enable the replacement of existing rotational machines and provide grid services such as grid resiliency services and black-start. Hydrogen assets (fuel cells) have the potential to successfully replace rotating machines and act as voltage and frequency master by leveraging the long-duration and seasonal energy storage capabilities of hydrogen technologies. This poster presents the progress made in budget period 1 of the proposed work. We will leverage an existing ARIES platform experimental setup to run power-hardware-in-the-loop and controller-hardware-in-the-loop experiments with grid forming fuel cell inverters to develop and document the standardization requirements.

electrolyzer↗

Independent Orbiter Assessment (IOA): Analysis of the Electrical Power Distribution and Control Subsystem, Volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C) hardware. The EPD and C hardware performs the functions of distributing, sensing, and controlling 28 volt DC power and of inverting, distributing, sensing, and controlling 117 volt 400 Hz AC power to all Orbiter subsystems from the three fuel cells in the Electrical Power Generation (EPG) subsystem. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list.

Schmeckpeper, K. R.↗

Interpenetration and kinetic effects in converging, high-energy plasma jets

In this work, we report on numerical simulations of laser-driven convergent plasma fusion targets. These “inverted corona” fusion targets are useful for the study of counter-streaming and converging rarefied plasma flows, and previous experiments have demonstrated their potential as neutron sources. The scheme consists of a fuel layer lined along the interior surface of a hollow plastic shell that is laser-ablated and expands inward towards the target center. The plasma streams generated in these targets are initially nearly collisionless as they converge, leading to wide interaction length scales and long interaction time scales as the jets interpenetrate. Such kinetic effects impact mixing of constituent ions - a phenomenon not properly captured by single-fluid hydrodynamic simulations. Here we conduct numerical simulations using two different methods: (1) single-fluid simulations in HYDRA, and (2) kinetic-ion, fluid-electron hybrid particle-in-cell (PIC) simulations in the code Chicago. It is shown that the initially nearly collisionless plasma fronts interpenetrate deeply and lead to broader interaction regions in space and time resulting in significant beam-beam fusion. The two approaches make different, testable predictions for the effect of fuel-layer thickness on neutron yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEReliction: A Cybersecurity Vulnerability Assessment Methodology for Distributed Energy Resources

With the increasing integration of Distributed Energy Resources (DER) into the electric grid, maintaining grid reliability and resilience requires that these devices remain secure. This paper discusses a cybersecurity vulnerability assessment methodology that incorporates best practices from Sandia National Laboratories, SANS Institute, OWASP Foundation, and other web and Internet of Things (IoT) penetration testing (“pen testing”) programs, courses, and frameworks for assessing the security posture of devices. The methodology involves five sequential steps: (1) Collect Public Information, (2) Extract Hardware Details, (3) Inventory Software Components, (4) Identify Vulnerabilities, and (5) Test Vulnerabilities. Each step uncovers potential weaknesses in both hardware and software components of DER devices, considering adversary tactics, techniques, and procedures (TTPs), and potential attack vectors along the way. The results from the execution of this method on multiple residential- and small commercial-scale photovoltaic (PV) inverters reveled hardware and software vulnerabilities, which highlight the benefit of taking a methodical approach to discover vulnerabilities. While the specific vulnerability details are not shared here, a generalized overview of findings underscore the importance of robust security assessments for DER devices. Adoption of an assessment framework of this kind will identify and mitigate cybersecurity threats and bolster the resilience of DER-integrated electric grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sources of field-aligned currents in the auroral plasma

Data from the Dynamics Explorer 1 High Altitude Plasma Instrument (HAPI) and magnetometer are used to investigate the sources of field-aligned currents in the nightside auroral zone. It is found that the formula developed by S. Knight predicts the field-aligned current density fairly accurately in regions where a significant potential drop can be inferred from the HAPI data; there are, however, regions in which the proportionality between potential drop and field-aligned current does not hold. In particular, occurrences of strong upward field-aligned current associated not with inverted-V events but instead with suprathermal bursts are noted. In addition, upward field-aligned currents are often observed to peak near the edges of inverted-V events, rather than in the center as would be predicted by Knight.

Marshall, J. A.↗

Development of a rotary power transformer and inverter drive for spacecraft

Many future satellites and spacecraft with spun and despun configurations will require the transfer of power across rotating interfaces in lieu of slip-rings and/or flexures. This is particularly true of spacecraft that have to demonstrate a long life expectancy. The rotary transformer has the desirable characteristics of high reliability and low noise, which qualify it as a potential replacement for slip rings. Development of a rotary power transformer follows the successful completion of a task to develop rotary signal-level transformers for the Galileo Spacecraft Project. The physical configuration of a rotary power transformer has a significant effect on its magnetic and electrical characteristics and therefore impacts the design of the dc/ac inverter driver. Important characteristics addressed during this development effort include: operating frequency, efficiency, transformer gap size, leakage inductance, and leakage flux. A breadboard inverter and rotary transformer were designed, fabricated and tested.

Mclyman, W. T.↗