Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Fault geometry and slip distribution of the 2008 M w 7.9 Wenchuan, China earthquake, inferred from GPS and InSAR measurements

We revisit the problem of coseismic rupture of the 2008 M w 7.9 Wenchuan earthquake. Precise determination of the fault structure and slip distribution provides critical information about the mechanical behaviour of the fault system and earthquake rupture. We use all the geodetic data available, craft a more realistic Earth structure and fault model compared to previous studies, and employ a nonlinear inversion scheme to optimally solve for the fault geometry and slip distribution. Compared to a homogeneous elastic half-space model and laterally uniform layered models, adopting separate layered elastic structure models on both sides of the Beichuan fault significantly improved data fitting. Our results reveal that: (1) The Beichuan fault is listric in shape, with near surface fault dip angles increasing from ~36° at the southwest end to ~83° at the northeast end of the rupture. (2) The fault rupture style changes from predominantly thrust at the southwest end to dextral at the northeast end of the fault rupture. (3) Fault slip peaks near the surface for most parts of the fault, with~8.4mthrust and ~5 m dextral slip near Hongkou and ~6 m thrust and ~8.4 m dextral slip near Beichuan, respectively. (4) The peak slips are located around fault geometric complexities, suggesting that earthquake style and rupture propagation were determined by fault zone geometric barriers. Such barriers exist primarily along restraining left stepping discontinuities of the dextralcompressional fault system. (5) The seismic moment released on the fault above 20 km depth is 8.2 × 10 21 N m, corresponding to an M w 7.9 event. The seismic moments released on the local slip concentrations are equivalent to events of M w 7.5 at Yingxiu-Hongkou, M w 7.3 at Beichuan-Pingtong, M w 7.2 near Qingping, M w 7.1 near Qingchuan, and M w 6.7 near Nanba, respectively. (6) The fault geometry and kinematics are consistent with a model in which crustal deformation at the eastern margin of the Tibetan plateau is decoupled by differential motion across a decollement in the mid crust, above which deformation is dominated by brittle reverse faulting and below which deformation occurs by viscous horizontal shortening and vertical thickening.

58 GEOSCIENCES↗

Artificial Intelligence Designer of Materials and Processes for Advanced Power Generation

In this presentation, ‘deep-freeze’ graphs, ‘convoluted filtering’ networks, ‘mirror-image’ graphs, and adversarial ensemble methods are utilized to support inversion modeling for optimization of the complex compositions and complex processes in design of high-performing alloys, with their properties tailored to the energy application specifications.

Romanov, Vyacheslav↗

sMF-BO-2CoGP: A sequential multi-fidelity constrained Bayesian optimization framework for design applications

Bayesian optimization (BO) is an effective surrogate-based method that has been widely used to optimize simulation-based applications. While the traditional Bayesian optimization approach only applies to single-fidelity models, many realistic applications provide multiple levels of fidelity with various levels of computational complexity and predictive capability. In this work, we propose a multi-fidelity Bayesian optimization method for design applications with both known and unknown constraints. The proposed framework, called sMF-BO-2CoGP, is built on a multi-level CoKriging method to predict the objective function. An external binary classifier, which we approximate using a separate CoKriging model, is used to distinguish between feasible and infeasible regions. Finally, the sMF-BO-2CoGP method is demonstrated using a series of analytical examples and a flip-chip application for design optimization to minimize the deformation due to warping under thermal loading conditions.

42 ENGINEERING↗

Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy

Purpose: Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. Methods: The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight parameters were determined for the weighted S-TPS-RPM. Results: The weighted S-TPS-RPM registration algorithm with optimal parameters significantly improved the anatomical accuracy as compared to S-TPS-RPM registration of the bladder alone and reduced the range of the anatomical errors by half as compared with the simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. The weighted algorithm reduced the RDE range of lipiodol markers from 0.9-14 mm after rigid bone match to 0.9-4.0 mm, compared to a range of 1.1-9.1 mm with S-TPS-RPM of bladder alone and 0.9-9.4 mm for simultaneous nonweighted registration. All registration methods resulted in good geometric accuracy on the bladder; average error values were all below 1.2 mm. Conclusions: The weighted S-TPS-RPM registration algorithm with additional weight parameter allowed indirect control over structure-specific flexibility in multistructure registrations of bladder and bladder tumor, enabling anatomically coherent registrations. The availability of an anatomically validated deformable registration method opens up the horizon for improvements in IGART for bladder cancer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-202: Impact of Monte Carlo Dose Calculation Algorithm On Prostate SBRT Treatments

Purpose: The purpose of this work was to quantify the dosimetric impact of using Monte Carlo algorithm on pre calculated SBRT prostate treatment with pencil beam dose calculation algorithm. Methods: A 6MV photon beam produced by a Novalis TX (BrainLAB-Varian) linear accelerator equipped with HDMLC was used. Treatment plans were done using 9 fields with Iplanv4.5 (BrainLAB) and dynamic IMRT modality. Institutional SBRT protocol uses a total dose to the prostate of 40Gy in 5 fractions, every other day. Dose calculation is done by pencil beam (2mm dose resolution), heterogeneity correction and dose volume constraint (UCLA) for PTV D95%=40Gy and D98%>39.2Gy, Rectum V20Gy<50%, V32Gy<20%, V36Gy<10% and V40Gy<5%, Bladder V20Gy<40% and V40Gy<10%, femoral heads V16Gy<5%, penile bulb V25Gy<3cc, urethra and overlap region between PTV and PRV Rectum Dmax<42Gy. 10 SBRT treatments plans were selected and recalculated using Monte Carlo with 2mm spatial resolution and mean variance of 2%. DVH comparisons between plans were done. Results: The average difference between PTV doses constraints were within 2%. However 3 plans have differences higher than 3% which does not meet the D98% criteria (>39.2Gy) and should have been renormalized. Dose volume constraint differences for rectum, bladder, femoral heads and penile bulb were les than 2% and within tolerances. Urethra region and overlapping between PTV and PRV Rectum shows increment of dose in all plans. The average difference for urethra region was 2.1% with a maximum of 7.8% and for the overlapping region 2.5% with a maximum of 8.7%. Conclusion: Monte Carlo dose calculation on dynamic IMRT treatments could affects on plan normalization. Dose increment in critical region of urethra and PTV overlapping region with PTV could have clinical consequences which need to be studied. The use of Monte Carlo dose calculation algorithm is limited because inverse planning dose optimization use only pencil beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-157: CARMEN: A MatLab-Based Research Platform for Monte Carlo Treatment Planning (MCTP) and Customized System for Planning Evaluation

Purpose: Although there exist several radiotherapy research platforms, such as: CERR, the most widely used and referenced; SlicerRT, which allows treatment plan comparison from various sources; and MMCTP, a full MCTP system; it is still needed a full MCTP toolset that provides users complete control of calculation grids, interpolation methods and filters in order to “fairly” compare results from different TPSs, supporting verification with experimental measurements. Methods: This work presents CARMEN, a MatLab-based platform including multicore and GPGPU accelerated functions for loading RT data; designing treatment plans; and evaluating dose matrices and experimental data.CARMEN supports anatomic and functional imaging in DICOM format, as well as RTSTRUCT, RTPLAN and RTDOSE. Besides, it contains numerous tools to accomplish the MCTP process, managing egs4phant and phase space files.CARMEN planning mode assist in designing IMRT, VMAT and MERT treatments via both inverse and direct optimization. The evaluation mode contains a comprehensive toolset (e.g. 2D/3D gamma evaluation, difference matrices, profiles, DVH, etc.) to compare datasets from commercial TPS, MC simulations (i.e. 3ddose) and radiochromic film in a user-controlled manner. Results: CARMEN has been validated against commercial RTPs and well-established evaluation tools, showing coherent behavior of its multiple algorithms. Furthermore, CARMEN platform has been used to generate competitive complex treatment that has been published in comparative studies. Conclusion: A new research oriented MCTP platform with a customized validation toolset has been presented. Despite of being coded with a high-level programming language, CARMEN is agile due to the use of parallel algorithms. The wide-spread use of MatLab provides straightforward access to CARMEN’s algorithms to most researchers. Similarly, our platform can benefit from the MatLab community scientific developments as filters, registration algorithms etc. Finally, CARMEN arises the importance of grid and filtering control in treatment plan comparison.

60 APPLIED LIFE SCIENCES↗

SU-E-T-765: Treatment Planning Comparison of SFUD Proton and 4Ï€ Radiotherapy for Prostate Cases

Purpose: Single-Field Uniform Dose (SFUD) proton scanning beams and non-coplanar 4π intensity-modulated radiation therapy (IMRT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate treatment. Methods: Five prostate patients were planned using 4π radiotherapy and SFUD to an initial dose of 54Gy to a planning target volume (PTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2Gy to the prostate for a total dose of 79.2 Gy. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams using a greedy column generation algorithm. The SFUD plans utilized two coplanar, parallel-opposing lateral scanning beams. The SFUD plan PTV was modified to account for range uncertainties while keeping an evaluation PTV identical to that of the X-ray plans for comparison. PTV doses, bladder and rectum dose volumes (V40, V45, V60, V70, V75.6, and V80), R50, and PTV homogeneity index (D95/D5) were evaluated. Results: Compared to SFUD, 4π resulted in 6.8% lower high dose spillage as indicated by R50. Bladder and rectum mean doses were 38.3% and 28.2% lower for SFUD, respectively. However, bladder and rectum volumes receiving >70Gy were 13.1% and 12% greater using proton SFUD. Due to the parallel-opposing beam arrangement, SFUD resulted in greater femoral head (87.8%) and penile bulb doses (43.7%). 4π PTV doses were slightly more homogeneous (HI 0.99 vs. 0.98) than the SFUD dose. Conclusion: Proton is physically advantageous to reduce the irradiated normal volume and mean doses to the rectum and bladder but it is also limited in the beam orientations and entrance dose, which resulted in greater doses to the femoral heads and penile bulb, and larger volumes of rectum and bladder exposed to high dose due to the required robust PTV definition. This project is supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.0

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transformations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations.

Essiari, Abdelilah↗

Automated CT registration, segmentation, and quantification (AutoCT) v1.1

Processing and analyzing brain imaging is crucial in both scientific development and clinical field. In this software package, we build a pipeline that integrates automatic registration, segmentation, and quantitative analysis for subjects' CT scans. Leveraging diffeomorphic transofrmations, we enable optimized forward and inverse mappings between an image and the reference. Furthermore, we extract localized features from deformation field based on an online template process, which advances statistical learning downstream. The created templates, atlas as well as our methods provide the brain imaging community tools for AI implementations

Bai, Zhe↗

Evolution of artificial intelligence for application in contemporary materials science

Abstract Contemporary materials science has seen an increasing application of various artificial intelligence techniques in an attempt to accelerate the materials discovery process using forward modeling for predictive analysis and inverse modeling for optimization and design. Over the last decade or so, the increasing availability of computational power and large materials datasets has led to a continuous evolution in the complexity of the techniques used to advance the frontier. In this Review, we provide a high-level overview of the evolution of artificial intelligence in contemporary materials science for the task of materials property prediction in forward modeling. Each stage of evolution is accompanied by an outline of some of the commonly used methodologies and applications. We conclude the work by providing potential future ideas for further development of artificial intelligence in materials science to facilitate the discovery, design, and deployment workflow. Graphical abstract

Materials Science↗

Multi-Fidelity Active Subspaces for Wind Farm Uncertainty Quantification

Wind plants operate in stochastic environments characterized by complex turbulent flow dynamics and high-dimensional random variables. A key step in uncertainty quantification studies is sensitivity analysis and dimension reduction that can facilitate the development of surrogate models to be used for forward and inverse propagation or optimization under uncertainty. Prior work has shown active subspaces are an effective tool for identifying important directions in the space of stochastic inputs; however, they have only been applied to single-fidelity wind plant models. In this study, we investigate the efficacy of a multi-fidelity active subspace method for analyzing the uncertainty in wind plant power output. The multi-fidelity active subspace estimator offers the promise of increased accuracy in identifying active subspaces as compared to a single-fidelity estimator for the same computational cost, or a reduction in cost for the same accuracy. This makes the study of uncertainty in larger wind plants and with higher fidelity physics tractable. The multi-fidelity active subspace method is applied to gridded and existing wind plant layouts with single and multiple inflow conditions and its performance for surrogate modeling and uncertainty propagation is compared against a single-fidelity active subspace method. This multi-fidelity approach yields substantial computational speedups of 2x - 3.4x across the test cases along with acceptable accuracy in surrogate modeling and computing statistical moments.

active subspace↗

Deep Generative Models for Materials Discovery and Machine Learning-Accelerated Innovation

Machine learning and artificial intelligence (AI/ML) methods are beginning to have significant impact in chemistry and condensed matter physics. For example, deep learning methods have demonstrated new capabilities for high-throughput virtual screening, and global optimization approaches for inverse design of materials. Recently, a relatively new branch of AI/ML, deep generative models (GMs), provide additional promise as they encode material structure and/or properties into a latent space, and through exploration and manipulation of the latent space can generate new materials. These approaches learn representations of a material structure and its corresponding chemistry or physics to accelerate materials discovery, which differs from traditional AI/ML methods that use statistical and combinatorial screening of existing materials via distinct structure-property relationships. However, application of GMs to inorganic materials has been notably harder than organic molecules because inorganic structure is often more complex to encode. In this work we review recent innovations that have enabled GMs to accelerate inorganic materials discovery. We focus on different representations of material structure, their impact on inverse design strategies using variational autoencoders or generative adversarial networks, and highlight the potential of these approaches for discovering materials with targeted properties needed for technological innovation.

36 MATERIALS SCIENCE↗

Feasibility of a unified approach to intensity-modulated radiation therapy and volume-modulated arc therapy optimization and delivery

Purpose: To study the feasibility of unified intensity-modulated arc therapy (UIMAT) which combines intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) optimization and delivery to produce superior radiation treatment plans, both in terms of dose distribution and efficiency of beam delivery when compared with either VMAT or IMRT alone. Methods: An inverse planning algorithm for UIMAT was prototyped within the PINNACLE treatment planning system (Philips Healthcare). The IMRT and VMAT deliveries are unified within the same arc, with IMRT being delivered at specific gantry angles within the arc. Optimized gantry angles for the IMRT and VMAT phases are assigned automatically by the inverse optimization algorithm. Optimization of the IMRT and VMAT phases is done simultaneously using a direct aperture optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using a unified optimization technique and compared with clinical IMRT or VMAT plans. Delivery verification was performed with an ArcCheck phantom (Sun Nuclear) on a Varian TrueBeam linear accelerator (Varian Medical Systems). Results: In this prototype implementation, the UIMAT plans offered the same target dose coverage while reducing mean doses to organs at risk by 8.4% for head-and-neck cases, 5.7% for lung cases, and 3.5% for prostate cases, compared with the VMAT or IMRT plans. In addition, UIMAT can be delivered with similar efficiency as VMAT. Conclusions: In this proof-of-concept work, a novel radiation therapy optimization and delivery technique that interlaces VMAT or IMRT delivery within the same arc has been demonstrated. Initial results show that unified VMAT/IMRT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

Optimal lattice-structured materials

This paper describes a method for optimizing the mesostructure of lattice-structured materials. These materials are periodic arrays of slender members resembling efficient, lightweight macroscale structures like bridges and frame buildings. Current additive manufacturing technologies can assemble lattice structures with length scales ranging from nanometers to millimeters. Previous work demonstrates that lattice materials have excellent stiffness- and strength-to-weight scaling, outperforming natural materials. However, there are currently no methods for producing optimal mesostructures that consider the full space of possible 3D lattice topologies. The inverse homogenization approach for optimizing the periodic structure of lattice materials requires a parameterized, homogenized material model describing the response of an arbitrary structure. This work develops such a model, starting with a method for describing the long-wavelength, macroscale deformation of an arbitrary lattice. The work combines the homogenized model with a parameterized description of the total design space to generate a parameterized model. Finally, the work describes an optimization method capable of producing optimal mesostructures. Several examples demonstrate the optimization method. One of these examples produces an elastically isotropic, maximally stiff structure, here called the isotruss, that arguably outperforms the anisotropic octet truss topology.

36 MATERIALS SCIENCE↗

PyOED: An Extensible Suite for Data Assimilation and Model-Constrained Optimal Design of Experiments

This article describes PyOED, a highly extensible scientific package that enables developing and testing model-constrained optimal experimental design (OED) for inverse problems. Specifically, PyOED aims to be a comprehensive Python toolkit for model-constrained OED. The package targets scientists and researchers interested in understanding the details of OED formulations and approaches. It is also meant to enable researchers to experiment with standard and innovative OED technologies with a wide range of test problems (e.g., simulation models). OED, inverse problems (e.g., Bayesian inversion), and data assimilation (DA) are closely related research fields, and their formulations overlap significantly. Thus, PyOED is continuously being expanded with a plethora of Bayesian inversion, DA, and OED methods as well as new scientific simulation models, observation error models, and observation operators. These pieces are added such that they can be permuted to enable testing OED methods in various settings of varying complexities. The PyOED core is completely written in Python and utilizes the inherent object-oriented capabilities; however, the current version of PyOED is meant to be extensible rather than scalable. Specifically, PyOED is developed to “enable rapid development and benchmarking of OED methods with minimal coding effort and to maximize code reutilization.” This article provides a brief description of the PyOED layout and philosophy and provides a set of exemplary test cases and tutorials to demonstrate the potential of the package.

97 MATHEMATICS AND COMPUTING↗

Clinically Applicable Monte Carlo–based Biological Dose Optimization for the Treatment of Head and Neck Cancers With Spot-Scanning Proton Therapy

Purpose: Our aim is to demonstrate the feasibility of fast Monte Carlo (MC)–based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods and Materials: Recently, a fast and accurate graphics processor unit (GPU)–based MC simulation of proton transport was developed and used as the dose-calculation engine in a GPU-accelerated intensity modulated proton therapy (IMPT) optimizer. Besides dose, the MC can simultaneously score the dose-averaged linear energy transfer (LET{sub d}), which makes biological dose (BD) optimization possible. To convert from LET{sub d} to BD, a simple linear relation was assumed. By use of this novel optimizer, inverse biological planning was applied to 4 patients, including 2 small and 1 large thyroid tumor targets, as well as 1 glioma case. To create these plans, constraints were placed to maintain the physical dose (PD) within 1.25 times the prescription while maximizing target BD. For comparison, conventional intensity modulated radiation therapy (IMRT) and IMPT plans were also created using Eclipse (Varian Medical Systems) in each case. The same critical-structure PD constraints were used for the IMRT, IMPT, and biologically optimized plans. The BD distributions for the IMPT plans were obtained through MC recalculations. Results: Compared with standard IMPT, the biologically optimal plans for patients with small tumor targets displayed a BD escalation that was around twice the PD increase. Dose sparing to critical structures was improved compared with both IMRT and IMPT. No significant BD increase could be achieved for the large thyroid tumor case and when the presence of critical structures mitigated the contribution of additional fields. The calculation of the biologically optimized plans can be completed in a clinically viable time (<30 minutes) on a small 24-GPU system. Conclusions: By exploiting GPU acceleration, MC-based, biologically optimized plans were created for small–tumor target patients. This optimizer will be used in an upcoming feasibility trial on LET{sub d} painting for radioresistant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NEW DEVELOPMENTS ON INVERSE POLYGON MAPPING TO CALCULATE GRAVITATIONAL LENSING MAGNIFICATION MAPS: OPTIMIZED COMPUTATIONS

We derive an exact solution (in the form of a series expansion) to compute gravitational lensing magnification maps. It is based on the backward gravitational lens mapping of a partition of the image plane in polygonal cells (inverse polygon mapping, IPM), not including critical points (except perhaps at the cell boundaries). The zeroth-order term of the series expansion leads to the method described by Mediavilla et al. The first-order term is used to study the error induced by the truncation of the series at zeroth order, explaining the high accuracy of the IPM even at this low order of approximation. Interpreting the Inverse Ray Shooting (IRS) method in terms of IPM, we explain the previously reported N {sup -3/4} dependence of the IRS error with the number of collected rays per pixel. Cells intersected by critical curves (critical cells) transform to non-simply connected regions with topological pathologies like auto-overlapping or non-preservation of the boundary under the transformation. To define a non-critical partition, we use a linear approximation of the critical curve to divide each critical cell into two non-critical subcells. The optimal choice of the cell size depends basically on the curvature of the critical curves. For typical applications in which the pixel of the magnification map is a small fraction of the Einstein radius, a one-to-one relationship between the cell and pixel sizes in the absence of lensing guarantees both the consistence of the method and a very high accuracy. This prescription is simple but very conservative. We show that substantially larger cells can be used to obtain magnification maps with huge savings in computation time.

97 MATHEMATICS AND COMPUTING↗

Optimizing the performance of bandpass photon detectors for inverse photoemission: Transmission of alkaline earth fluoride window crystals

Bandpass photon detectors are widely used in inverse photoemission in the isochromat mode at energies in the vacuum-ultraviolet spectral range. The energy bandpass of gas-filled counters is usually formed by the ionization threshold of the counting gas as high-pass filter and the transmission cutoff of an alkaline earth fluoride window as low-pass filter. The transmission characteristics of the window have, therefore, a crucial impact on the detector performance. We present transmission measurements in the vacuum-ultraviolet spectral range for alkaline earth fluoride window crystals in the vicinity of the transmission cutoff as a function of crystal purity, surface finish, surface contamination, temperature, and thickness. Our findings reveal that the transmission characteristics of the window crystal and, thus, the detector performance depend critically on these window parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗