Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Internal energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Volume-energy parameters and turbulent-flow density fluctuations

Volume-energy relations determined from an equation of state were used to group many sets of heat transfer data for liquids and gases, including the near-critical region. The volume - Gibbs energy parameter grouped these data better than did such other parameters as enthalpy, temperature, or internal energy.

Hendricks, R. C.↗

Impacts of Model Building Energy Codes – Interim Update

The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressure–Strain Interaction as the Energy Dissipation Estimate in Collisionless Plasma

The dissipative mechanism in weakly collisional plasma is a topic that pervades decades of studies without a consensus solution. We compare several energy dissipation estimates based on energy transfer processes in plasma turbulence and provide justification for the pressure–strain interaction as a direct estimate of the energy dissipation rate. The global and scale-by-scale energy balances are examined in 2.5D and 3D kinetic simulations. We show that the global internal energy increase and the temperature enhancement of each species are directly tracked by the pressure–strain interaction. The incompressive part of the pressure–strain interaction dominates over its compressive part in all simulations considered. The scale-by-scale energy balance is quantified by scale filtered Vlasov–Maxwell equations, a kinetic plasma approach, and the lag dependent von Kármán–Howarth equation, an approach based on fluid models. We find that the energy balance is exactly satisfied across all scales, but the lack of a well-defined inertial range influences the distribution of the energy budget among different terms in the inertial range. Therefore, the widespread use of the Yaglom relation in estimating the dissipation rate is questionable in some cases, especially when the scale separation in the system is not clearly defined. In contrast, the pressure–strain interaction balances exactly the dissipation rate at kinetic scales regardless of the scale separation.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Master Planning: Identifying Framing Constraints that Scope Your Technology Options

This paper addresses the framing constraints for building and community energy projects that must be considered when energy master planning (EMP) is conducted. The constraints cover emissions, sustainability, resilience, regulations and directives, and regional and local limitations such as available energy types, local conditions, and project requirements. The paper reflects development results from participants in an International Energy Agency project on energy master planning and in a U.S. Department of Defense project on technology integration to achieve resilient, low-energy use military installations. It identifies a comprehensive list of framing constraints categorized into locational threats, locational resources, energy and water distribution and storage systems, building and facility, indoor environmental, and equipment in buildings and district systems constraints. In addition, it identifies limits for these constraints that exist in seven participating countries. Some framing constraints can profoundly impact technology selection while others impact the installation of technologies (as in hardening) and have little to no impact on technology selection. Furthermore, framing constraints can be assessed in different ways and there are resources available to help EMP stakeholders evaluate them. Finally, a case is made that identifying and applying framing constraints early in EMP can bring efficiencies and better focus to the EMP process. We come to the conclusion that (1) for holistic energy planning, it is essential to identify and assess the framing constraints that bound an optimized EMP solution, (2) framing constraints limits should be evaluated as either hard or soft or promising technologies may fall out of an EMP analysis, (3) to maintain consistent quality in the EMP process, the identification of framing constraints and their limits, and perhaps their evaluation, should be standardized, (4) a standardized approach could establish a baseline that can be used, built upon, and improved, (5) as automated EMP tools are improved or developed, the resources in this paper could possibly contribute to their interworkings relative to technology screening, and (6) continued climate change and resulting aggressive goal setting will likely drive a continued and strong emphasis on EMP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Discrete Rotational Energy for Polyatomic Molecules in Direct Simulation Monte Carlo

Accurate prediction of aerothermodynamic loads in thermal non-equilibrium flows requires precise modeling of internal energy exchange. While previous direct simulation Monte Carlo frameworks have successfully implemented discrete rotational energy models for diatomic species, the treatment of polyatomic molecules has traditionally relied on continuous energy assumptions that break down at low temperatures and neglect critical high-temperature corrections. This study extends the discrete rotational energy models of Boyd and Gimelshein to fully encompass polyatomic molecules. The proposed framework implements quantized rotational energy level sampling for linear, spherical, and symmetric/asymmetric top rotors. Crucially, the model incorporates centrifugal distortion to address the limitations of the rigid-rotor assumption at hypersonic temperatures, and accounts for nuclear spin parity, which dictates the permissible rotational states and macroscopic specific heats at low temperatures. The model is verified through equilibrium sampling procedures, demonstrating agreement with theoretical quantum Boltzmann distributions and accurately reproducing thermophysical properties across a wide range of temperatures.

DSMC↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Step-by-step state-selective tracking of fragmentation dynamics of water dications by momentum imaging

Abstract The double photoionization of a molecule by one photon ejects two electrons and typically creates an unstable dication. Observing the subsequent fragmentation products in coincidence can reveal a surprisingly detailed picture of the dynamics. Determining the time evolution and quantum mechanical states involved leads to deeper understanding of molecular dynamics. Here in a combined experimental and theoretical study, we unambiguously separate the sequential breakup via D + + OD + intermediates, from other processes leading to the same D + + D + + O final products of double ionization of water by a single photon. Moreover, we experimentally identify, separate, and follow step by step, two pathways involving the b 1 Σ + and a 1 Δ electronic states of the intermediate OD + ion. Our classical trajectory calculations on the relevant potential energy surfaces reproduce well the measured data and, combined with the experiment, enable the determination of the internal energy and angular momentum distribution of the OD + intermediate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Protein folding from heterogeneous unfolded state revealed by time-resolved X-ray solution scattering

One of the most challenging tasks in biological science is to understand how a protein folds. In theoretical studies, the hypothesis adopting a funnel-like free-energy landscape has been recognized as a prominent scheme for explaining protein folding in views of both internal energy and conformational heterogeneity of a protein. Despite numerous experimental efforts, however, comprehensively studying protein folding with respect to its global conformational changes in conjunction with the heterogeneity has been elusive. Here we investigate the redox-coupled folding dynamics of equine heart cytochrome c (cyt-c) induced by external electron injection by using time-resolved X-ray solution scattering. A systematic kinetic analysis unveils a kinetic model for its folding with a stretched exponential behavior during the transition toward the folded state. With the aid of the ensemble optimization method combined with molecular dynamics simulations, we found that during the folding the heterogeneously populated ensemble of the unfolded state is converted to a narrowly populated ensemble of folded conformations. These observations obtained from the kinetic and the structural analyses of X-ray scattering data reveal that the folding dynamics of cyt-c accompanies many parallel pathways associated with the heterogeneously populated ensemble of unfolded conformations, resulting in the stretched exponential kinetics at room temperature. This finding provides direct evidence with a view to microscopic protein conformations that the cyt-c folding initiates from a highly heterogeneous unfolded state, passes through still diverse intermediate structures, and reaches structural homogeneity by arriving at the folded state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated reaction kinetics and network exploration (Arkane): A statistical mechanics, thermodynamics, transition state theory, and master equation software

The open-source statistical mechanics software described here, Arkane–Automated Reaction Kinetics and Network Exploration–facilitates computations of thermodynamic properties of chemical species, high-pressure limit reaction rate coefficients, and pressure-dependent rate coefficient over multi-well molecular potential energy surfaces (PES) including the effects of collisional energy transfer on phenomenological kinetics. Arkane can use estimates to fill in information for molecules or reactions where quantum chemistry information is missing. The software solves the internal energy master equation for complex unimolecular reaction systems. Inputs to the software include converged electronic structure computations performed by the user using a variety of supported software packages (Gaussian, Molpro, Orca, TeraChem, Q-Chem, Psi4). The software outputs high-pressure limit rate coefficients and pressure-dependent phenomenological rate coefficients, as well as computed thermodynamic properties (enthalpy, entropy, and constant pressure heat capacity) with added energy corrections. Some of the key features of Arkane include treatment of 1D, 2D or ND hindered internal rotation modes, treatment of free internal rotation modes, quantum tunneling effect consideration, transition state theory (TST) and Rice-Ramsperger-Kassel-Marcus (RRKM) rate coefficient computations, master equation solution with four implemented methods, inverse-Laplace transform of high-pressure limit rate coefficients into the energy domain, energy corrections based on bond-additivity or isodesmic reactions, automated and efficient PES exploration, and PES sensitivity analysis. The present work describes the design of Arkane, how it should be used, and refers to the theory that it employs. Arkane is distributed via the RMG-Py software suite (https://github.com/ReactionMechanismGenerator/RMG-Py).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep space network energy program

If the Deep Space Network is to exist in a cost effective and reliable manner in the next decade, the problems presented by international energy cost increases and energy availability must be addressed. The Deep Space Network Energy Program was established to implement solutions compatible with the ongoing development of the total network.

Friesema, S. E.↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Comparison of loads from HAWC2 and OpenFAST for the IEA Wind 15 MW Reference Wind Turbine

Reference wind turbines (RWTs) that reflect the state-of-the-art of current wind energy technology are necessary in order to properly evaluate innovative methods in wind turbine design and evaluation. The International Energy Agency (IEA) Wind Technology Collaboration Platform (TCP) Task 37 has recently developed a new RWT geared towards offshore floating-foundation applications: the IEA Wind 15 MW. The model has been implemented in two aeroelastic codes, OpenFAST and HAWC2, based on an underlying common ontology. However, these toolchains result in slightly different structural parameters, and the two codes utilise different structural models. Thus, to increase the utility of the model, it is necessary to compare the aeroelastic responses. This paper compares aeroelastic loads calculated using different fidelities of the blade model in OpenFAST (ElastoDyn and BeamDyn) and HAWC2 (prismatic Timoshenko without torsion and Timoshenko with fully populated stiffness matrix), where both codes use the DTU Basic controller and the same turbulence boxes to reduce discrepancies. The aeroelastic responses to steady wind, step wind and turbulent wind (per IEC 61400-1 wind class IB) are considered. The results indicate a generally good agreement between the loads dominated by aerodynamic thrust and force, especially for the no-torsion blade models. Discrepancies were observed in other load channels, partially due to differences in the asymmetric loading of the rotor and partially due to differing closed-loop dynamics, and they will be the subject of future investigations.

17 WIND ENERGY↗

The IEA Wind Task 49 Reference Floating Wind Array Design Basis

International Energy Agency Wind Technology Collaboration Programme (IEA Wind) Task 49 on Integrated Design of Floating Wind Arrays is an international collaboration aiming to advance the development of large-scale floating wind farms by providing open-access resources to the research and development and planning communities. The work of Task 49 focuses on array-level challenges related to the colocation of many floating wind turbines; their layouts, mooring systems, and cabling systems; failure risks; logistical considerations; marine spatial planning needs; and future research needs and innovation directions. This report provides a general design basis for the development of reference floating wind farm designs. These reference array designs will extend the scope of existing reference floating wind turbine designs to facilitate research on array-level floating wind technology challenges and innovations. The design basis promotes coordination and consistency in developing the reference array designs.

17 WIND ENERGY↗

Shock wave properties of anorthosite and gabbro

Hugoniot data on San Gabriel anorthosite and San Marcos gabbro to 11 GPA are presented. Release paths in the stress-density plane and sound velocities are reported as determined from particl velocity data. Electrical interference effects precluded the determination of accurate release paths for the gabbro. Because of the loss of shear strength in the shocked state, the plastic behavior exhibited by anorthosite indicates that calculations of energy partitioning due to impact onto planetary surfaces based on elastic-plastic models may underestimate the amount of internal energy deposited in the impacted surface material.

Boslough, M. B.↗

Shock wave properties of anorthosite and gabbro

Huyoniot data on San Gabriel anorthosite and San Marcos gabbro to 11 GPA are presented. Release paths in the stress-density plane and sound velocities are reported as determined from partial velocity data. Electrical interference effects precluded the determination of accurate release paths for the gabbro. Because of the loss of shear strength in the shocked state, the plastic behavior exhibited by anorthosite indicates that calculations of energy partitioning due to impact onto planetary surfaces based on elastic-plastic models may underestimate the amount of internal energy deposited in the impacted surface material.

Boslough, M. B.↗

Data Base for CFD Validation

The flow behind the shock wave formed around objects which fly at hypervelocity behaves differently from that of a perfect gas. Molecules become vibrationally excited, dissociated, and ionized. The hot gas may emit or absorb radiation. When the atoms produced by dissociation reach the wall surface, chemical reactions, including recombination, may occur. The thermochemical phenomena of vibration, dissociation, ionization, surface chemical reaction, and radiation are referred to commonly as high-temperature real-gas phenomena. The phenomena cause changes in the dynamic behavior of the flow and the surface pressure and heat transfer distribution around the object. The character of a real gas is described by the internal degrees of freedom and state of constituent molecules; nitrogen and oxygen for air. The internal energy states, rotation, vibration and electronic, of the molecules are excited and, in the limit, the molecular bonds are exceeded and the gas dissociated into atomic and, possibly, ionic constituents. The process of energy transfer causing excitation, dissociation and recombination is a rate process controlled by particle collisions. Binary, two-body, collisions are sufficient to cause internal excitation, dissociation and ionization while three-body collisions are required to recombine the particles into molecular constituents. If the rates of energy transfer are fast with respect to the local fluid dynamic time scale the gas is in, or nearly in, equilibrium. If the energy transfer rates are very slow the gas can be described as frozen. In all other instances, wherein any of the energy exchange rates are comparable to the local fluid time scale, the gas will be thermally or chemically reacting and out of equilibrium. Real gas thermochemical nonequilibrium processes are important in the determination of aerodynamic heating; both convective (including wall catalytic effects) and radiative heating. To illustrate this we consider the hypervelocity flow over a bluff body typical of an atmospheric entry vehicle or an aerospace transfer vehicle (ASTV). The qualitative aspects of a hypersonic flow field over a bluff body are discussed in two parts, forebody and afterbody, with attention to which particular physical effects must be included in an analysis. This will indicate what type of numerical modeling will be adequate in each region of the flow. A bluff forebody flow field is dominated by the presence of the strong bow shock wave and the consequent heating, and chemical reaction of the gas. At high altitude hypersonic flight conditions the thermal excitation and chemical reaction of the gas occur slowly enough that a significant portion of the flow field is in a state of thermochemical nonequilibrium. A second important effect is the presence of the thick boundary layer along the forebody surface. In this region there are large thermal and chemical species gradients due to the interaction of the gas with the wall. Also at high altitudes the shock wave and the boundary layer may become so thick that they merge; in this case the entire shock layer is dominated by viscous effects.

Deiwert, George S.↗