Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Change of calibration of diffraction-based particle sizers in dense sprays

A calibration procedure for diffraction-based particle-sizing instruments using multielement detectors is briefly reviewed. The effects of multiple scattering due to dense sprays on the calibration of these instruments are then examined over a range of sprays with Sauter mean diameters from 20 to 55 microns. An empirical scheme to correct for changes in calibration due to dense sprays or other scattering media is presented.

Dodge, L. G.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

50 Years of Spaceflight with Fourier Transform Spectrometers (FTS) Built at NASA GSFC

Over the past 50 years, NASA Goddard Space Flight Center (GSFC) has been developing, building, testing and flying a series of Fourier Transform Spectrometers (FTS). This began with the IRIS instruments on the Earth-orbiting Nimbus satellites and progressed to more sophisticated designs optimized for interplanetary spacecraft sent to Mars and later to the outer solar system. Adaptions have been made over time, including progressively higher spectral resolution, sensitivity, numbers of detectors and complexity. Instrument operating temperatures have decreased to enable remote sensing of the cold giant planet systems. In this paper we describe the historical evolution of this instrument line, comparing and contrasting different aspects such as optical design and materials, detector types and data handling. We conclude by looking towards the future. At present the CIRS-Lite prototype is being tested at NASA GSFC for potential use on a future mission to the ice giants, Uranus and Neptune. Surpassing the previous performance of the Voyager IRIS instruments remains challenging, and new technologies that could enable these measurements are discussed.

Nixon, Conor A.↗

The ISEE 1 and 2 Medium Energy Particles Experiment

The Medium Energy Particles Experiment (MEPE) on board ISEE 1 and 2 consists of the WIM instrument on ISEE 1 and the KED instrument on ISEE 2. Both instruments employ solid-state detectors and magnetic analysis to measure the angular, energy, and intensity distributions of protons (ions) above 24 keV and electrons above 20 keV. The WIM instrument also includes a composition measurement employing Delta E-by-E and time-of-flight techniques. Three-parameter analysis is performed above 250 keV/nucleon, and single parameter analysis is performed above 125 keV/nucleon for helium through oxygen. Three-dimensional angular distributions are obtained through the use of a scan platform in the WIM instrument and multiple detector heads in the KED instrument. A variety of operational modes are used to optimize data collection from both instruments. Resolutions up to 128 channels in energy, 192 samples over the unit sphere in angle, and 0.095 sec in time are available.

Williams, D. J.↗

H Ly-alpha transmittance of thin foils of C, Si/C, and Al/C for keV particle detectors

A class of instruments designed for remote sensing of space plasmas by measuring energetic neutral atoms (ENA) uses a thin foil as both a signal generator and a light shield. An ENA imager must look directly at the ENA source region, which is also usually an intense source of H Ly-alpha (1216 A) photons. It is desirable to minimize the energy threshold for ENA detectors, at the same time maximizing the blocking of H Ly-alpha. Optimizing filter design to meet these two contrary requirements has led us to measure the transmittance of thin C, Si/C, and Al/C foils at H Ly-alpha. Our results indicate that (1) transmittance of less than 0.0007 can be achieved with 7 micro-g/sq cm Si on 1.7 micro-g/sq cm C; (2) an Si/C composite foil with a thin carbon layer is more effective in blocking UV radiation while having the lowest energy threshold of all the foils measured; and (3) transmittance of Si/C foils of known Si and C thicknesses cannot be accurately predicted, but must be measured.

Drake, V. A.↗

Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

Wrbanek, John D.↗

The Energetic Trans-Iron Nuclei Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)" which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.3 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of ~20 m2sr. Measurements made in space for a period of 3 years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized heavy elements (Pu and Cm), what the age of that component is, and test the model of the OB association origin of galactic cosmic rays. Additionally, it will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas.

Binns, W. R.↗

The Energetic Trans-Iron Cosmic-ray Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)", which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.5 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of approx.20 sq m sr. Measurements made in space for a period of three years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized transuranic elements (Pu-94 and Cm-96), to measure the age of that component, and to test the model of the OB association origin of galactic cosmic rays. Additionally, these observations will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas. Keywords: cosmic rays Galaxy:abundances

Binns, W. R.↗

Ultraviolet spectrometer/polarimeter

Improved satellite instrument package consists of telescope, spectrometer with polarimeter, five detectors, and control electronics. Instrument is designed to study solar ultraviolet radiation. Polarimeter will determine four Stokes parameters and possible mechanisms for producing linear and circular polarization. Density measurements of Earth's upper atmosphere constituents are possible.

Source record↗

Feasibility of Passive Cryogenic Cooling for Solar Powered Outer Planetary Missions

Spacescience instruments with cooled detectors require innovative thermal cooling solutions to meet science objectives. Detector sensitivity increases with decreasing temperature and low optics temperatures are often needed to reduce background photon noise. As the detector spectral range coverage increases from the visible to far infrared also requires lower detector temperatures. Increasing demands on detector performance lead to larger format detectors and higher refresh rates resulting in significant increases in power dissipation. Passive coolers rely on emissive power of radiating surfaces to reject heat to space. As the operating temperature requirements of detectors and optics decreases, the ability to reject heat to space becomes increasingly more difficult. Reducing both cooler internal parasitic and external environmental heat loads and maximizing the passive cooler field of view to space will enhance performance. While instrument heat loads and passive cooler parasitic heat loads are controlled by instrument designers, the external environmental heat loads and cooler views to space are governed by spacecraft and mission designers. Solar powered planetary missions require large arrays to generate sufficient power for spacecraft subsystems and payloads. Two or more solar array wings with cell coverage of the order of 40-80 m2 are often needed to generate sufficient power at 3-6 AU. These large arrays are typically symmetrically configured and can extend tens of meters. The arrays along with spacecraft attitude requirements near the target planetary bodies pose significant challenges for passive cooling at large AU. It is very difficult to provide a clear field of view to space for the cooler with large articulating arrays while keeping solar loads from impinging the cooler and meeting the spacecraft attitude science pointing requirements. This is counter intuitive because of the decreasing solar flux and colder planetary body temperatures at large AU. This paper presents the challenges and opportunities of passive cryogenic cooling versus active cooling for solar powered planetary missions.

Rodriguez, Jose I.↗

Conceptual thermal design and analysis of a far-infrared/mid-infrared remote sensing instrument

This paper presents the conceptual thermal design and analysis results for the Spectroscopy of the Atmosphere using Far-Infrared Emission (SAFIRE) instrument. SAFIRE has been proposed for Mission to Planet Earth to study ozone chemistry in the middle atmosphere using remote sensing of the atmosphere in the far-infrared (21-87 microns) and mid-infrared (9-16 microns) spectra. SAFIRE requires that far-IR detectors be cooled to 3-4 K and mid-IR detectors to 80 K for the expected mission lifetime of five years. A superfluid helium dewar and Stirling-cycle cryocoolers provide the cryogenic temperatures required by the infrared detectors. The proposed instrument thermal design uses passive thermal control techniques to reject 465 watts of waste heat from the instrument.

Roettker, William A.↗

The Swift Gamma Ray Burst Mission

Swift is an international mission managed by NASA as part of its MIDEX program. It is a multiwavelength transient observatory for GRB astronomy that will launch in 2004. The goals of the mission are to determine the origin of GRBs and their afterglows and use bursts to probe the early Universe. A wide field gamma-ray camera will detect more than a hundred GRBs per year to 2-5 times fainter than BATSE. Sensitive narrow-field X-ray, and UV/optical telescopes will be pointed at the burst location in 20 to 75 sec by an autonomously controlled 'swift' spacecraft. For each burst, arcsec positions will be determined and optical/UV/x-ray/gamma-ray spectrophotometry performed. Measurements of redshift will be made for many of the bursts. The instrumentation is a combination of superb existing flight-spare hardware and design from XMM and Spectrum-X/JET-X contributed by collaborators in the UK and Italy and development of a coded-aperture camera with a large-area (approx. 0.5 square meter) CdZnTe detector array. The instruments have now completed their fabrication phase and are integrated on the observatory for final testing. Key components of the mission are vigorous follow-up and outreach programs to engage the astronomical community and public in Swift. The talk will describe the mission and its status and give a summary of our plans for GRB operations.

Gehrels, Neil↗

Measurements of K Shell Emission of Highly Charged Ions with the XRS at EBIT

The XRS/EBIT is a 32 channel microcalorimeter spectrometer operating at the electron beam ion trap (EBIT) facility at Lawrence Livermore National Laboratory. The system contains a flight candidate detector array from the XRS instrument for the Astro-E2 mission. The detector array in the XRS/EBIT is functionally identical to the flight array integrated into the XRS instrument and benefits from the enormous amount of calibration data from the XRS program. Since the XRSEBIT was upgraded with the new detector array in October 2003, the system has been used for a number of experiments including a survey of the K shell emission from He-like and H-like O, Ne, Ar, Fe, Ni and Kr as well as for L shell emission to measure the 3C/3D line ratio in Ni. Here we present some basic operational parameters of the instrument as well as direct excitation and simulated maxwellian spectra of He-like and E-like Fe. We show that the XRS instrument can resolve the Lyal and Lya2 lines from each other as well as from the dielectronic recombination satellites in thermal H-like Fe. We also show exactly how well the XRS instrument on Astro-E2 will resolve the thermal He-like triplet in collisionally excited Fe. This work was funded under NASA's Research Opportunities in Space Science program.

Porter, F. Scott↗

NASA's present and future sensor technology developments

NASA's overall sensing, data acquisition, and instrumentation programs are reviewed. The review shows that the trends in advanced sensor technology involve increased use of solid-state sensors, multiapplication sensors, standardized instrumentation, and miniaturized detectors. Examples are given of several new technologies, showing how improvements in sensor operational capability (such as enhanced sensitivity and spectral range) derived from these advances have resulted in relaxed spacecraft stability requirements, mission time savings, and savings in weight, size, and power. The introduction of multiapplication sensors and standardized instrumentation will result in measurement cost reduction and improved compatibility with standardized spacecraft.

Rubin, B.↗

Performance of the HIRS/2 instrument on TIROS-N

The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

Koenig, E. W.↗

Dynamic range considerations for EUV MAMA detectors

The multianode microchannel array (MAMA) has been chosen as the detector for two instruments on the ESA/NASA Solar Heliospheric Observatory. The response of the MAMA to the two extreme types of solar spectra, disk and corona, have been modeled with a view toward evaluating dynamic range effects present. The method of MAMA operation is discussed, with emphasis given to modeling the effect of electron cloud charge spreading to several detector anodes and amplifiers (n-fold events). Representative synthetic EUV spectra have been created. The detector response to these spectra is modeled by dissecting the input photon radiation field across the detector array into contributions to the various amplifier channels. The results of this dissection are shown for spectral regions across the entire wavelength region of interest. These results are used to identify regions in which total array photon counting rate or individual amplifier rate may exceed the design limits. This allows the design or operational modes to be tailored to eliminate the problem areas.

Illing, Rainer M. E.↗

Recent developments and applications with gas cell correlation spectrometer

Gaspec, a gas filter correlation spectrometer, is described. Gaspec is a dual-gas three-channel instrument using two detectors which receive amplitude-shared source signals modulated at the frequency of the chopper. Several units for operation around the 3-5 micron and the 8-15 micron region have been constructed, and gases such as CO2, CO, CH4, HCl, NO, and hydrazines can be detected. Advantages of Gaspec are considered with reference to improvements developed for the basic Cospec (gas cell correlation spectrometer) instrument.

Barringer, A. R.↗