Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ducted Fuel Injection and Cooled Spray Technologies for Particulate Control in Heavy-Duty Diesel Engines

Heavy-duty diesel engine manufacturers are continually seeking simple, low-cost technologies to reduce emissions. Ducted Fuel Injection (DFI) and Cooled Spray (CS) technologies have emerged as promising solutions, offering the potential for nearly sootless operation. These innovations could significantly decrease harmful Particulate Matter (PM) emissions while enabling further optimization to reduce Nitrogen Oxides (NOx) and increase efficiency. While initial experiments across various engine types have shown promise, uncertainties remain regarding the ideal geometry, scaling properties, and effectiveness of these technologies across different operating conditions. This project aims to address these knowledge gaps through experiments in both optical and metal single-cylinder engines.

33 ADVANCED PROPULSION SYSTEMS↗

EIC hadron ring longitudinal stability simulations at injection

At the EIC injection energy (23.8 GeV for protons), the hadron beam experiences a relatively strong space charge field. The corresponding wakefield, in conjunction with the wakes from the RF cavities (i.e. the geometrical wakes), may become the cause of single-bunch instabilities, both longitudinal and transverse. In this report, we focus on the longitudinal stability aspect of this picture, using a simplified model for the ring.

43 PARTICLE ACCELERATORS↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

High-Voltage Pulsed Power Generator for Beam Injection Systems

Beam injection systems in hadron colliders require kickers generating ±50 kV peak voltages into a 50 Ω impedance, with peak currents of 1000 A and sub-10 ns rise and fall times. This paper presents a novel high-voltage pulse power generator utilizing a distributed pulser architecture. It combines gallium nitride (GaN) transistors in a Marx topology with an inductive adder, achieving nanosecond-scale switching speeds and high-power efficiency. Compared to other solutions such as based on MOSFETs or fast ionization dynistors, our development offers superior peak and average power performance, reduced system complexity, and enhanced reliability, marking a significant step forward in high-voltage pulse generation for accelerator applications.

Smirnov, Alexander (ORCID:0000000280631691)↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Giant Modulation of Magnetoresistance in a Van Der Waals Magnet by In‐Plane Current Injection

Efficient magnetization control is a central issue in magnetism and spintronics. Particularly, there are increasing demands for manipulation of magnetic states in van der Waals (vdW) magnets with unconventional functionalities. However, the electrically induced phase transition between ferromagnetic-to-antiferromagnetic states without external magnetic field is yet to be demonstrated. Here, the current-induced magnetic phase transition in a vdW ferromagnet Fe 5 GeTe 2 is reported. Based on magneto-transport measurements and theoretical analysis, it is demonstrated that transition in the interlayer magnetic coupling occurs through vertical voltage drop between layers induced by current which is attributed to high anisotropy of the resistivity caused by the vdW gaps. Such magnetic phase transition results in giant modulation of the longitudinal magnetoresistance from 5% to 170%. The electrical tunability of the magnetic phase in Fe 5 GeTe 2 with current-in-plane geometry opens a path for electric control of magnetic properties, expanding the ability to use vdW magnets for spintronic applications.

2D magnet↗

A novel digital lifecycle for Material‐Process‐Microstructure‐Performance relationships of thermoplastic olefins foams manufactured via supercritical fluid assisted foam injection molding

Abstract This research significantly enhances the applicability of thermoplastic olefins (TPOs) in the automotive industry using supercritical N 2 as a physical foaming agent, effectively addressing the limitations of traditional chemical agents. It merges experimental results with simulations to establish detailed material‐process‐microstructure‐performance (MP2) relationships, targeting 5–20% weight reductions. This innovative approach labeled digital lifecycle (DLC) helps accurately predict tensile, flexural, and impact properties based on the foam microstructure, along with experimentally demonstrating improved paintability. The study combines process simulations with finite element models to develop a comprehensive digital model for accurately predicting mechanical properties. Our findings demonstrate a strong correlation between simulated and experimental data, with about a 5% error across various weight reduction targets, marking significant improvements over existing analytical models. This research highlights the efficacy of physical foaming agents in TPO enhancement and emphasizes the importance of integrating experimental and simulation methods to capture the underlying foaming mechanism to establish material‐process‐microstructure‐performance (MP2) relationships. Highlights Establishes a material‐process‐microstructure‐performance (MP2) for TPO foams Sustainably produces TPO foams using supercritical (ScF) N 2 with 20% lightweighting Shows enhanced paintability for TPO foam improved surface aesthetics Digital lifecycle (DLC) that predicts both foam microstructure and properties DLC maps process effects & microstructure onto FEA mesh for precise prediction

Engineering↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗